ASAlison Su

Alison Su

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alison Su has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single‐Cell Nucleus Extraction with Cellular Indexing

    by Trinh Lam, Ana Esmeralda Gomez Martinez, Alison Su, Anna Fomitcheva‐Khartchenko, Xin Wang, Nazibul Islam, Paul Lum, Amy Elizabeth Herr

    Bulk organelle‑fractionation masks cell‑to‑cell heterogeneity, and existing microfluidic methods cannot reliably reconnect each isolated organelle to its parent cell, an essential capability for multiomics readouts. VacTrap, a high‐throughput microfluidic device that isolates and spatially indexes single nuclei from mammalian cells is developed. The VacTrap device consisted of three aligned layers: 1) a Bis‐gel microwells layer with a “trapdoor” (BAC‐gel) base, fabricated atop a through‐hole glass slide; 2) a polydimethylsiloxane (PDMS) microwell layer to receive transferred nuclei; and 3) a vacuum manifold. VacTrap operation begins with cell cytoplasmic lysis using differential detergent fractionation (DDF) to release intact nuclei into the Bis‐gel microwells, while cytoplasmic proteins are electrophoresed into the Bis‐gel layer. Subsequent addition of dithiothreitol (DTT) and vacuum dissolves the trapdoors within 3–5 min, synchronously transferring nuclei into the PDMS microwells, achieving 98% efficiency across 80% of trapdoors. To verify fractionation of the cytoplasmic proteins from each cell nucleus, select protein targets are successfully detected by in situ immunoprobing in the archival Bis‐gel layer. To verify the fractionation and collection of individual intact nuclei, the morphology analysis confirms preservation of the nuclear features. By introducing spatial indexing of nuclei back to the originating cell, VacTrap provides a robust, automated cell‐preparation platform for single‐cell multiomics applications.


  • Optical Attenuators Extend Dynamic Range but Alter Angular Response of Planar Ultraviolet‐C Dosimeters

    by Alison Su, Alisha Geldert, Samantha M. Grist, Amy E. Herr

    Effective ultraviolet‐C (UV‐C) decontamination protocols of N95 respirators require validation that the entire N95 surface receives sufficient dose. Photochromic indicators (PCIs) can accurately measure UV‐C dose on nonplanar surfaces, but often saturate below doses required to decontaminate porous, multilayered textiles like N95s. Here, we investigate the use of optical attenuators to extend PCI dynamic range while maintaining a near‐ideal angular response—critical for accurate measurements of uncollimated UV‐C. We show analytically that tuning attenuator refractive index, attenuation coefficient, and thickness can extend dynamic range, but compromises angular response unless the attenuator is an ideal diffuser. To investigate this tradeoff empirically, we stack PCIs behind model specular (floated borosilicate) and diffuse (polytetrafluoroethylene) attenuators, characterize the angular response, and evaluate on‐N95 UV‐C measurement accuracy within a decontamination system. Both attenuators increase PCI dynamic range >4×, but simultaneously introduce angle‐dependent transmittance, which causes location‐dependent underestimation of UV‐C dose. PCI‐borosilicate and PCI‐polytetrafluoroethylene stacks underreport true on‐N95 dose by (1) 14.7% and 3.6%, respectively, when near‐normal to the source lamp array, and (2) 40.8% and 19.8%, respectively, in a steeply sloped location. Overall, we demonstrate that while planar attenuators can increase PCI dynamic range, verifying near‐ideal angular response is critical for accurate UV‐C measurements.


  • Open Access

    Nonuniform UV-C dose across N95 facepieces can cause 2.9-log variation in SARS-CoV-2 inactivation

    by Alisha Geldert, Alison Su, Allison W. Roberts, Guillaume Golovkine, Samantha M. Grist, Sarah A. Stanley, Amy E. Herr

    During public health crises like the COVID-19 pandemic, ultraviolet-C (UV-C) decontamination of N95 respirators for emergency reuse has been implemented to mitigate shortages. However, decontamination efficacy across N95s is poorly understood, due to the dependence on received UV-C dose, which varies across the complex three-dimensional N95 shape. Robust quantification of UV-C dose across N95 facepieces presents challenges, as few UV-C measurement tools have sufficient 1) small, flexible form factor, and 2) angular response. To address this gap, we combine optical modeling and quantitative photochromic indicator (PCI) dosimetry with viral inactivation assays to generate high-resolution maps of “on-N95” UV-C dose and concomitant SARS-CoV-2 viral inactivation across N95 facepieces within a commercial decontamination chamber. Using modeling to rapidly identify on-N95 locations of interest, in-situ measurements report a 17.4 ± 5.0-fold dose difference across N95 facepieces in the chamber, yielding 2.9 ± 0.2-log variation in SARS-CoV-2 inactivation. UV-C dose at several on-N95 locations was lower than the lowest-dose locations on the chamber floor, highlighting the importance of on-N95 dose validation. Overall, we couple optical simulation with in-situ PCI dosimetry to relate UV-C dose and viral inactivation at specific on-N95 locations, informing the design of safe and effective decontamination protocols.


  • Open Access

    Best Practices for Germicidal Ultraviolet-C Dose Measurement for N95 Respirator Decontamination

    by Alisha Geldert, Halleh B. Balch, Anjali Gopal, Alison Su, Samantha M. Grist, Amy E. Herr

    Ultraviolet-C (UV-C) decontamination holds promise in combating the coronavirus disease 2019 pandemic, particularly with its potential to mitigate the N95 respirator shortage. Safe, effective, and reproducible decontamination depends critically on UV-C dose, yet dose is frequently measured and reported incorrectly, which results in misleading and potentially harmful protocols. Understanding best practices in UV-C dose measurement for N95 respirator decontamination is essential to the safety of medical professionals, researchers, and the public. Here, we outline the fundamental optical principles governing UV-C irradiation and detection, as well as the key metrics of UV-C wavelength and dose. In particular, we discuss the technical and regulatory distinctions between UV-C N95 respirator decontamination and other applications of germicidal UV-C, and we highlight the unique considerations required for UV-C N95 respirator decontamination. Together, this discussion will inform best practices for UV-C dose measurement for N95 respirator decontamination during crisis-capacity conditions.


  • Open Access

    UV-C decontamination for N95 emergency reuse: Quantitative dose validation with photochromic indicators

    by Alison Su, Samantha M. Grist, Alisha Geldert, Anjali Gopal, Amy E. Herr

    With COVID-19 N95 respirator shortages, frontline medical personnel are forced to reuse this disposable – but sophisticated – multilayer textile respirator. Widely used for decontamination of nonporous surfaces, UV-C light has germicidal efficacy on porous, non-planar N95 respirators when ≥1.0 J/cm 2 dose is applied across all surfaces. Here, we address outstanding limitations of photochromic indicators (qualitative readout and insufficient dynamic range) and introduce a photochromic UV-C dose quantification technique for: (1) design of UV-C treatments and (2) in-process UV-C dose validation. Our methodology establishes that color-changing dosimetry can achieve the necessary accuracy (>90%), uncertainty (95%). Furthermore, we adapt consumer electronics for accessible quantitative readout and extend the dynamic range >10× using optical attenuators. In a measurement infeasible with radiometers, we observe striking 20× dose variation over 3D N95 facepieces. By transforming photochromic indicators into quantitative dosimeters, we illuminate critical design considerations for both photochromic indicators and UV-C decontamination.


  • Laterally Aggregated Polyacrylamide Gels for Immunoprobed Isoelectric Focusing

    by Shaheen Jeeawoody, Kevin A. Yamauchi, Alison Su, Amy E. Herr

    Immunoprobed isoelectric focusing (IEF) resolves proteins based on differences in isoelectric point (pI) and then identifies protein targets through immunoprobing of IEF-separated proteins that have been immobilized onto a gel scaffold. During the IEF stage, the gel functions as an anti-convective medium and not as a molecular sieving matrix. During the immunoprobing stage, the gel acts as an immobilization scaffold for IEF-focused proteins via photoactive moieties. Here, we characterized the effect of gel pore size on IEF separation and in-gel immunoassay performance. We modulated polyacrylamide (PA) gel pore size via lateral chain aggregation initiated by PEG monomers. During IEF, the 2% PEG highly porous PA gel formulation offered higher resolution (minimum pI difference ∼0.07 ± 0.02) than unmodified 6%T, 3.3%C (benchmark) and 6%T, 8%C (negative control) PA gels. The highly porous gels supported a pH gradient with slope and linearity comparable to benchmark gels. The partition coefficient for antibodies into the highly porous gels (K = 0.35 ± 0.02) was greater than the benchmark (3×) and negative control (1.75×) gels. The highly porous gels also had lower immunoassay background signal than the benchmark (2×) and negative control (3×) gels. Taken together, lateral aggregation creates PA gels that are suitable for both IEF and subsequent in-gel immunoprobing by mitigating immunoprobe exclusion from the gels while facilitating removal of unbound immunoprobe.


  • In Situ Measurement of Thermodynamic Partitioning in Open Hydrogels

    by Alison Su, Benjamin E. Smith, Amy E. Herr

    Thermodynamic partitioning dictates solute loading and release from a hydrogel. Design of drug delivery vehicles, cell and tissue matrices, and immunoassay scaffolds that utilize hydrogel materials is informed by an understanding of the thermodynamic partitioning properties of those hydrogels. We develop aberration-compensated laser scanning confocal microscopy (AC-LSCM), a technique that can be applied to all fluorescence microscopy-based equilibrium partition coefficient measurements where the fluorescence is uniformly distributed in the reference material (e.g., many solutes in thermodynamic equilibrium). In this paper, we use AC-LSCM to measure spatially resolved in situ equilibrium partition coefficients of various fluorescently labeled solutes in single-layer and multilayer open hydrogels. In considering a dynamic material, we scrutinize solute interactions with a UV photoactive polyacrylamide gel that incorporates a benzophenone methacrylamide backbone. We observed strong agreement with an adjusted version of Ogston’s ideal size-exclusion model for spatially resolved in situ equilibrium partition coefficients across a wide range of polyacrylamide hydrogel densities (R2 = 0.98). Partition coefficients of solutes differing in hydrodynamic radius were consistent with size-based theory in the photoactive hydrogels, but exceed those in unmodified polyacrylamide gels. This observation suggests a deviation from the size-exclusion model and a shift in the thermodynamic equilibrium state of the solutes toward the gel phase. AC-LSCM also resolves differential partitioning behavior of the model solute in two-layer gels, providing insight into the transport phenomena governing the partitioning in multilaminate gel structures. Furthermore, AC-LSCM identifies and quantifies depth-dependent axial aberrations that could confound quantitation, highlighting the need for the “aberration compensated” aspect of AC-LSCM.