Yuxin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuxin Li has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Ashley Elizabeth Ross
Department of Chemistry, University of Cincinnati, 312 College Dr. 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
7 shared publications - Michael Thomas Cryan
Department of Chemistry, University of Cincinnati, 404 Crosley Tower, 312 College Drive, Cincinnati, Ohio 45221-0172, United States
2 shared publications - Moriah E. Weese-Myers
Department of Chemistry, University of Cincinnati, 312 College Dr. 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
2 shared publications Ashley Ross
1 shared publicationAyah J. Syeed
University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
1 shared publicationBlaise J Ostertag
1 shared publication
Latest Publications
- 13 January 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (1) , 553-562
Employing Triphenylene-Based, Layered, Conductive Metal–Organic Framework Materials as Electrochemical Sensors for Nitric Oxide in Aqueous Media
This paper describes the first use of conductive metal-organic frameworks as the active material in the electrochemical detection of nitric oxide in aqueous solution. Four hexahydroxytriphenylene (HHTP)-based MOFs linked with first-row transition metal nodes (M = Co, Ni, Cu, Zn) were compared as thin-film working electrodes for promoting oxidation of NO using voltammetric and amperometric techniques. Cu- and Ni-linked MOF analogs provided signal enhancement of 5- to 7-fold over a control glassy carbon electrode (SANO = 6.7 ± 1.2 and 5.7 ± 1.1 for Ni3(HHTP)2 and Cu3(HHTP)2, respectively) for detecting micromolar concentrations of NO. Zinc-based MOF electrodes offered more limited enhancement (SANO = 3.1 ± 0.5), while the cobalt-based MOF analog had intrinsic redox activity at potentials close to NO oxidation, which interfered with sensing. Combining MOFs with a conductive polymer improved electrode stability under repeated electrochemical scanning (14 ± 3% decrease in signal over 10 scans). The stabilized Ni3(HHTP)2@polymer-coated electrodes were able to detect NO at physiologically relevant concentrations (LOD = 9.0 ± 4.8 nM) in amperometric sensing experiments, and exhibited moderate selectivity against ascorbic acid and nitrite (log kj,NO = -1.3 ± 0.3 and -0.83 ± 0.68 for ascorbic acid and nitrite, respectively). This study demonstrates that layered, conductive 2D MOFs have promising applicability for NO detection in aqueous environments.
- 13 January 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (1) , 553-562
Employing Triphenylene-Based, Layered, Conductive Metal–Organic Framework Materials as Electrochemical Sensors for Nitric Oxide in Aqueous Media
This paper describes the first use of conductive metal-organic frameworks as the active material in the electrochemical detection of nitric oxide in aqueous solution. Four hexahydroxytriphenylene (HHTP)-based MOFs linked with first-row transition metal nodes (M = Co, Ni, Cu, Zn) were compared as thin-film working electrodes for promoting oxidation of NO using voltammetric and amperometric techniques. Cu- and Ni-linked MOF analogs provided signal enhancement of 5- to 7-fold over a control glassy carbon electrode (SANO = 6.7 ± 1.2 and 5.7 ± 1.1 for Ni3(HHTP)2 and Cu3(HHTP)2, respectively) for detecting micromolar concentrations of NO. Zinc-based MOF electrodes offered more limited enhancement (SANO = 3.1 ± 0.5), while the cobalt-based MOF analog had intrinsic redox activity at potentials close to NO oxidation, which interfered with sensing. Combining MOFs with a conductive polymer improved electrode stability under repeated electrochemical scanning (14 ± 3% decrease in signal over 10 scans). The stabilized Ni3(HHTP)2@polymer-coated electrodes were able to detect NO at physiologically relevant concentrations (LOD = 9.0 ± 4.8 nM) in amperometric sensing experiments, and exhibited moderate selectivity against ascorbic acid and nitrite (log kj,NO = -1.3 ± 0.3 and -0.83 ± 0.68 for ascorbic acid and nitrite, respectively). This study demonstrates that layered, conductive 2D MOFs have promising applicability for NO detection in aqueous environments.
- 31 May 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (11) , 2173-2184
Sustained delivery of focal ischemia coupled to real-time neurochemical sensing in brain slices
A device capable of sustained local stimulation in tissue coupled to real-time electrochemical sensing was developed to study the impact of focal ischemia on local neurotransmission in the brain.
- 31 May 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (11) , 2173-2184
Sustained delivery of focal ischemia coupled to real-time neurochemical sensing in brain slices
A device capable of sustained local stimulation in tissue coupled to real-time electrochemical sensing was developed to study the impact of focal ischemia on local neurotransmission in the brain.
- Open Access
- 5 April 2022
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 233, 336-353
Nanostructured carbon-fiber surfaces for improved neurochemical detection
Fundamental insight into the extent to which the nanostructured surface and geometry impacts neurochemical interactions at electrode surfaces could provide significant advances in our ability to design and fabricate ultrasensitive neurochemical detection probes. Here, we investigate the extent to which the nanostructure of the carbon-fiber surface impacts detection of catecholamines and purines with fast-scan cyclic voltammetry (FSCV). Carbon-fibers were treated with argon (Ar) plasma to induce variations in the nano- and micro-structure without changing the functionalization of the surface. We tested variations in topology by measuring the extent to which the flow rate, RF power, and treatment time affect the surface roughness. Flow rates from 50–100 sccm, plasma power from 20–100 W, and treatment times from 30 s to 5 min were compared. Two Ar-treatments were chosen from the optimization studies for comparison, and the surface roughness was evaluated using atomic force microscopy (AFM). To ensure no changes in chemical composition, fibers were analyzed with X-ray photoelectron spectroscopy (XPS). On average, at the optimized Ar-plasma treatment procedure, oxidative current for adenosine and ATP increased by 3.5 ± 1.4-fold and 3.2 ± 0.6-fold, and guanosine and GTP by 1.7 ± 0.3-fold and 1.8 ± 0.3-fold, respectively (n = 9). Dopamine increased by 1.7 ± 0.3-fold. The extent to which changes in the electrode structure impact adsorption, sensitivity, and electron transfer rates were measured. A COMSOL Multiphysics simulation was developed to enable the modeling of mass transport of electroactive species at varying electrode geometries. Overall, this study provides critical insight into the extent to which the nanostructure of the surface impacts the electrochemical detection of neurochemicals.
- 5 April 2022
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 233, 336-353
Open AccessNanostructured carbon-fiber surfaces for improved neurochemical detection
Fundamental insight into the extent to which the nanostructured surface and geometry impacts neurochemical interactions at electrode surfaces could provide significant advances in our ability to design and fabricate ultrasensitive neurochemical detection probes. Here, we investigate the extent to which the nanostructure of the carbon-fiber surface impacts detection of catecholamines and purines with fast-scan cyclic voltammetry (FSCV). Carbon-fibers were treated with argon (Ar) plasma to induce variations in the nano- and micro-structure without changing the functionalization of the surface. We tested variations in topology by measuring the extent to which the flow rate, RF power, and treatment time affect the surface roughness. Flow rates from 50–100 sccm, plasma power from 20–100 W, and treatment times from 30 s to 5 min were compared. Two Ar-treatments were chosen from the optimization studies for comparison, and the surface roughness was evaluated using atomic force microscopy (AFM). To ensure no changes in chemical composition, fibers were analyzed with X-ray photoelectron spectroscopy (XPS). On average, at the optimized Ar-plasma treatment procedure, oxidative current for adenosine and ATP increased by 3.5 ± 1.4-fold and 3.2 ± 0.6-fold, and guanosine and GTP by 1.7 ± 0.3-fold and 1.8 ± 0.3-fold, respectively (n = 9). Dopamine increased by 1.7 ± 0.3-fold. The extent to which changes in the electrode structure impact adsorption, sensitivity, and electron transfer rates were measured. A COMSOL Multiphysics simulation was developed to enable the modeling of mass transport of electroactive species at varying electrode geometries. Overall, this study provides critical insight into the extent to which the nanostructure of the surface impacts the electrochemical detection of neurochemicals.
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (42) , 1717
Investigations of the Purine-Electrode Interface with Fast-Scan Cyclic Voltammetry
Understanding how the brain functions in both spatial and temporal domains is still unknown but vital for advancing knowledge of fundamental brain processes. One important class of brain biomolecules, purines, are involved in signal transduction, development, neuroinflammation, and neuromodulation. Despite their importance, purines remain difficult to detect with high specificity, sensitivity, and with adequate temporal resolution to capture signaling dynamics. Fast-scan cyclic voltammetry (FSCV) at carbon-fiber microelectrodes is a popular electrochemical technique most often used to study dopamine signaling in the brain due to its subsecond temporal resolution and excellent spatial resolution. Recent advances from our lab and others have demonstrated utility of using FSCV at carbon-based electrodes for adenosine and guanosine detection: two important purine signaling molecules in the brain. Despite these advances, a fundamental understanding of purine electrochemical detection at carbon-based electrodes is poorly understood, especially for anionic purinergic compounds like adenosine triphosphate (ATP) and guanosine triphosphate (GTP). Here, we will discuss our recent work which helps describe the extent to which the electrode surface chemistry, topographical structure, and geometry impact purine detection with FSCV. This work will ultimately lead to more sensitive and selective detection of purinergic signaling in the brain. Carbon-fibers have been a prominent electrode material for neurochemical detection with fast-scan cyclic voltammetry (FSCV) for the last several decades. Recently, the field has expanded to novel carbon nanomaterials due to their improved detection sensitivities and electron transfer kinetics. Despite, exploration to novel carbon materials, the majority of FSCV labs still use carbon-fiber microelectrodes on a routine basis for neurochemical analysis. Because of this, our lab has focused on tuning analyte-electrode interactions at carbon-fiber microelectrodes using a combination of surface modification strategies and novel carbon-fiber materials. We will discuss our latest efforts to improve purine detection with novel carbon surfaces. Plasma-treated carbon surfaces can dramatically change the functionality and topology of the surface. We have used O2, N2, and Ar gas to change the surface topology and functionality of carbon-fiber microelectrodes for improved purine detection. Overall, we show that the effects induced by plasma-treatment improve purine detection significantly more than catecholamine detection due to significantly roughened electrode surfaces with increased oxide and amine functionalization. In addition to plasma-treated surfaces, the chemical composition of the carbon-fiber surface can be modified by chemically reacting specific functionalities onto the surface. Traditionally, anionic detection with FSCV is limited due to minimal interactions of anions on the anionic carbon-fiber surface. We have used a chemical modification strategy involving both ethylenediamine (EDA) and N-ethyl-N’-(3-dimethylaminopropyl) carbodiimide (EDC) to functionalize the carbon-fiber surface with positively charged amines. In addition to chemical functionalization strategies for improved anionic purine detection, we have also investigated Au and Pt nanoparticle modified carbon-fibers for improved electrocatalysis of purines at the surface. Lastly, we have synthesized and developed new carbon-fiber geometries with improved edge-plane character on the surface which facilitate enhanced purine-electrode interactions. Overall, we provide new insights into the electrode-analyte interface for purine detection which has significantly improved our understanding of purine electrochemistry.
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2021-01 (42) , 1717
Investigations of the Purine-Electrode Interface with Fast-Scan Cyclic Voltammetry
Understanding how the brain functions in both spatial and temporal domains is still unknown but vital for advancing knowledge of fundamental brain processes. One important class of brain biomolecules, purines, are involved in signal transduction, development, neuroinflammation, and neuromodulation. Despite their importance, purines remain difficult to detect with high specificity, sensitivity, and with adequate temporal resolution to capture signaling dynamics. Fast-scan cyclic voltammetry (FSCV) at carbon-fiber microelectrodes is a popular electrochemical technique most often used to study dopamine signaling in the brain due to its subsecond temporal resolution and excellent spatial resolution. Recent advances from our lab and others have demonstrated utility of using FSCV at carbon-based electrodes for adenosine and guanosine detection: two important purine signaling molecules in the brain. Despite these advances, a fundamental understanding of purine electrochemical detection at carbon-based electrodes is poorly understood, especially for anionic purinergic compounds like adenosine triphosphate (ATP) and guanosine triphosphate (GTP). Here, we will discuss our recent work which helps describe the extent to which the electrode surface chemistry, topographical structure, and geometry impact purine detection with FSCV. This work will ultimately lead to more sensitive and selective detection of purinergic signaling in the brain. Carbon-fibers have been a prominent electrode material for neurochemical detection with fast-scan cyclic voltammetry (FSCV) for the last several decades. Recently, the field has expanded to novel carbon nanomaterials due to their improved detection sensitivities and electron transfer kinetics. Despite, exploration to novel carbon materials, the majority of FSCV labs still use carbon-fiber microelectrodes on a routine basis for neurochemical analysis. Because of this, our lab has focused on tuning analyte-electrode interactions at carbon-fiber microelectrodes using a combination of surface modification strategies and novel carbon-fiber materials. We will discuss our latest efforts to improve purine detection with novel carbon surfaces. Plasma-treated carbon surfaces can dramatically change the functionality and topology of the surface. We have used O2, N2, and Ar gas to change the surface topology and functionality of carbon-fiber microelectrodes for improved purine detection. Overall, we show that the effects induced by plasma-treatment improve purine detection significantly more than catecholamine detection due to significantly roughened electrode surfaces with increased oxide and amine functionalization. In addition to plasma-treated surfaces, the chemical composition of the carbon-fiber surface can be modified by chemically reacting specific functionalities onto the surface. Traditionally, anionic detection with FSCV is limited due to minimal interactions of anions on the anionic carbon-fiber surface. We have used a chemical modification strategy involving both ethylenediamine (EDA) and N-ethyl-N’-(3-dimethylaminopropyl) carbodiimide (EDC) to functionalize the carbon-fiber surface with positively charged amines. In addition to chemical functionalization strategies for improved anionic purine detection, we have also investigated Au and Pt nanoparticle modified carbon-fibers for improved electrocatalysis of purines at the surface. Lastly, we have synthesized and developed new carbon-fiber geometries with improved edge-plane character on the surface which facilitate enhanced purine-electrode interactions. Overall, we provide new insights into the electrode-analyte interface for purine detection which has significantly improved our understanding of purine electrochemistry.
- 3 May 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (20) , 2320-2330
Amine-functionalized carbon-fiber microelectrodes for enhanced ATP detection with fast-scan cyclic voltammetry
Here, we provide evidence that functionalizing the carbon-fiber surface with amines significantly improves direct electrochemical adenosine triphosphate (ATP) detection with fast-scan cyclic voltammetry (FSCV). ATP is an important extracellular signaling molecule throughout the body and can function as a neurotransmitter in the brain. Several methods have been developed over the years to monitor and quantitate ATP signaling in cells and tissues; however, many of them are limited in temporal resolution or are not capable of measuring ATP directly. FSCV at carbon-fiber microelectrodes is a widely used technique to measure neurotransmitters in real-time. Many electrode treatments have been developed to study the interaction of cationic compounds like dopamine at the carbon surface yet studies investigating how to improve anionic compounds, like ATP, at the carbon fiber surface are lacking. In this work, carbon-fibers were treated with N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide (EDC) which reacts with carboxylic acid groups on the carbon surface followed by reaction with ethylenediamine (EDA) to produce NH2-functionalized carbon surfaces. Overall, we a 5.2 ± 2.5-fold increase in ATP current with an approximately 9-fold increase in amine functionality, as analyzed by X-ray Photoelectron Spectroscopy, on the carbon surface was observed after modification with EDC-EDA. This provides evidence that amine-rich surfaces improve interactions with ATP on the surface. This study provides a detailed analysis of ATP interaction at carbon surfaces and ultimately a method to improve direct and rapid neurological ATP detection in the future.
- 3 May 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (20) , 2320-2330
Amine-functionalized carbon-fiber microelectrodes for enhanced ATP detection with fast-scan cyclic voltammetry
Here, we provide evidence that functionalizing the carbon-fiber surface with amines significantly improves direct electrochemical adenosine triphosphate (ATP) detection with fast-scan cyclic voltammetry (FSCV). ATP is an important extracellular signaling molecule throughout the body and can function as a neurotransmitter in the brain. Several methods have been developed over the years to monitor and quantitate ATP signaling in cells and tissues; however, many of them are limited in temporal resolution or are not capable of measuring ATP directly. FSCV at carbon-fiber microelectrodes is a widely used technique to measure neurotransmitters in real-time. Many electrode treatments have been developed to study the interaction of cationic compounds like dopamine at the carbon surface yet studies investigating how to improve anionic compounds, like ATP, at the carbon fiber surface are lacking. In this work, carbon-fibers were treated with N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide (EDC) which reacts with carboxylic acid groups on the carbon surface followed by reaction with ethylenediamine (EDA) to produce NH2-functionalized carbon surfaces. Overall, we a 5.2 ± 2.5-fold increase in ATP current with an approximately 9-fold increase in amine functionality, as analyzed by X-ray Photoelectron Spectroscopy, on the carbon surface was observed after modification with EDC-EDA. This provides evidence that amine-rich surfaces improve interactions with ATP on the surface. This study provides a detailed analysis of ATP interaction at carbon surfaces and ultimately a method to improve direct and rapid neurological ATP detection in the future.
- 19 May 2020
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 56 (58) , 8023-8026
High Young's modulus carbon fibers are fouling resistant with fast-scan cyclic voltammetry
High modulus carbon-fibers exhibit similar resistance to chemical fouling as carbon nanotube based materials with fast-scan cyclic voltammetry.
- 19 May 2020
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 56 (58) , 8023-8026
High Young's modulus carbon fibers are fouling resistant with fast-scan cyclic voltammetry
High modulus carbon-fibers exhibit similar resistance to chemical fouling as carbon nanotube based materials with fast-scan cyclic voltammetry.
- Open Access
- 17 April 2020
- Published by American Chemical Society (ACS)
Fast-scan cyclic voltammetry flow cell on-chip
- 17 April 2020
- Published by American Chemical Society (ACS)
Open AccessFast-scan cyclic voltammetry flow cell on-chip
- 2 December 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (3) , 805-815
Plasma-treated carbon-fiber microelectrodes for improved purine detection with fast-scan cyclic voltammetry
Here, we developed N2 and O2 plasma-treated carbon-fiber microelectrodes (CFME) for improved purine detection with fast-scan cyclic voltammetry (FSCV). Plasma treatment affects the topology and functionality of carbon which impacts the electrode–analyte interaction. CFME's are less sensitive to purines compared to catecholamines. Knowledge of how the electrode surface drives purine–electrode interaction would provide insight into methods to improve purine detection. Here, plasma-treated CFME's with N2 and O2 plasma was used to investigate the extent to which the surface functionality and topology affects purine detection and to improve purine sensing with FSCV. On average, O2 plasma increased the oxidative current for adenosine and ATP by 6.0 ± 1.2-fold and 6.4 ± 1.6-fold, and guanosine and GTP by 2.8 ± 0.47-fold and 5.8 ± 1.4-fold, respectively (n = 9). The O2 plasma increased the surface roughness and oxygen functionality. N2 plasma increased the oxidative current for adenosine and ATP by 1.5 ± 0.15-fold and 1.9 ± 0.23-fold, and guanosine and GTP by 1.4 ± 0.20-fold and 1.5 ± 0.20-fold, respectively (n = 11). N2 plasma increased the nitrogen functionality with minimal increases in roughness. Both plasma treatments impacted purines more than dopamine. Langmuir isotherms revealed that both plasma gases impact the theoretical surface coverage and adsorption strength of purines at the electrode. Overall, we show that purine detection is improved at surfaces with increased surface roughness, and oxygen and amine functionality. Plasma-treated CFMEs could be used in the future to study the analyte–electrode interaction of other neurochemicals.
- 2 December 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (3) , 805-815
Plasma-treated carbon-fiber microelectrodes for improved purine detection with fast-scan cyclic voltammetry
Here, we developed N2 and O2 plasma-treated carbon-fiber microelectrodes (CFME) for improved purine detection with fast-scan cyclic voltammetry (FSCV). Plasma treatment affects the topology and functionality of carbon which impacts the electrode–analyte interaction. CFME's are less sensitive to purines compared to catecholamines. Knowledge of how the electrode surface drives purine–electrode interaction would provide insight into methods to improve purine detection. Here, plasma-treated CFME's with N2 and O2 plasma was used to investigate the extent to which the surface functionality and topology affects purine detection and to improve purine sensing with FSCV. On average, O2 plasma increased the oxidative current for adenosine and ATP by 6.0 ± 1.2-fold and 6.4 ± 1.6-fold, and guanosine and GTP by 2.8 ± 0.47-fold and 5.8 ± 1.4-fold, respectively (n = 9). The O2 plasma increased the surface roughness and oxygen functionality. N2 plasma increased the oxidative current for adenosine and ATP by 1.5 ± 0.15-fold and 1.9 ± 0.23-fold, and guanosine and GTP by 1.4 ± 0.20-fold and 1.5 ± 0.20-fold, respectively (n = 11). N2 plasma increased the nitrogen functionality with minimal increases in roughness. Both plasma treatments impacted purines more than dopamine. Langmuir isotherms revealed that both plasma gases impact the theoretical surface coverage and adsorption strength of purines at the electrode. Overall, we show that purine detection is improved at surfaces with increased surface roughness, and oxygen and amine functionality. Plasma-treated CFMEs could be used in the future to study the analyte–electrode interaction of other neurochemicals.
- 28 March 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (4) , 1001-1007
Defect Sites Modulate Fouling Resistance on Carbon-Nanotube Fiber Electrodes
Carbon nanotube (CNT) fiber electrodes have become increasingly popular electrode materials for neurotransmitter detection with fast-scan cyclic voltammetry (FSCV). The unique properties of CNT fiber electrodes like increased electron transfer, sensitivity, waveform application frequency independence, and resistance to fouling make them ideal biological sensors for FSCV. In particular, their resistance to fouling has been observed for several years but the specific physical properties which aid in fouling resistance has been debated. Here, we investigate the extent to which the presence of defect sites on the surface attenuate both chemical and biological fouling with FSCV. We compared traditional carbon-fiber microelectrodes (CFME) to pristine-CNTs and functionalized-CNTs. CFME and functionalized CNTs are highly disordered with a great deal of defect sites on the surface. The pristine-CNTs have less defects compared to the purposefully functionalized CNTs and CFME’s. All electrode surfaces were characterized by a combination of scanning electron microscopy (SEM), Raman spectroscopy, and energy dispersive spectroscopy (EDS). Chemical fouling was studied using serotonin, a popular neurotransmitter notoriously known for electrode fouling. To assess biological fouling, electrodes were implanted in brain tissue for 2 hours. Defect sites on the carbon were shown to resist biofouling compared to pristine CNTs but were detrimental for serotonin detection. Overall, we provide insight into the extent to which the electrode surface dictates fouling resistance with FSCV. This work provides evidence that careful considerations of the surface of the CNT material is needed when designing sensors for fouling resistance.
- 28 March 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (4) , 1001-1007
Defect Sites Modulate Fouling Resistance on Carbon-Nanotube Fiber Electrodes
Carbon nanotube (CNT) fiber electrodes have become increasingly popular electrode materials for neurotransmitter detection with fast-scan cyclic voltammetry (FSCV). The unique properties of CNT fiber electrodes like increased electron transfer, sensitivity, waveform application frequency independence, and resistance to fouling make them ideal biological sensors for FSCV. In particular, their resistance to fouling has been observed for several years but the specific physical properties which aid in fouling resistance has been debated. Here, we investigate the extent to which the presence of defect sites on the surface attenuate both chemical and biological fouling with FSCV. We compared traditional carbon-fiber microelectrodes (CFME) to pristine-CNTs and functionalized-CNTs. CFME and functionalized CNTs are highly disordered with a great deal of defect sites on the surface. The pristine-CNTs have less defects compared to the purposefully functionalized CNTs and CFME’s. All electrode surfaces were characterized by a combination of scanning electron microscopy (SEM), Raman spectroscopy, and energy dispersive spectroscopy (EDS). Chemical fouling was studied using serotonin, a popular neurotransmitter notoriously known for electrode fouling. To assess biological fouling, electrodes were implanted in brain tissue for 2 hours. Defect sites on the carbon were shown to resist biofouling compared to pristine CNTs but were detrimental for serotonin detection. Overall, we provide insight into the extent to which the electrode surface dictates fouling resistance with FSCV. This work provides evidence that careful considerations of the surface of the CNT material is needed when designing sensors for fouling resistance.