Zuhal Yıldırım-Bilmez
Research Subjects
Zuhal Yıldırım-Bilmez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Soner Sismanoglu
Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University-Cerrahpasa, Istanbul, Turkey
3 shared publications - Aliye Tuğçe Gürcan
Department of Pediatric Dentistry, Faculty of Dentistry, Dokuz Eylul University, 35340 Izmir, Türkiye
2 shared publications Aysegul Erten-Taysi
Assistant Professor, Department of Oral and Maxillofacial Surgery, School of Dentistry, University of Altinbas, Istanbul, Turkey
1 shared publication- Başak Gözüyeşil Aslan
Hatay Mustafa Kemal University, Faculty of Dentistry, Department of, Restorative Dentistry Hatay, Turkey
1 shared publication Burak Gümüştaş
Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Medipol University, Istanbul, Turkey
1 shared publication- Burak Gümüştaş
Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Medipol University, Istanbul, Turkey
1 shared publication
Latest Publications
- Open Access
- 30 September 2021
- Published by Zeus Publishing in International Dental Research
- Vol. 11 (Suppl. 1) , 228-233
Evaluation of liquid sorption and color stability of dental composites after exposure to common lactation teas
Aim: To assess the effects of common lactation teas on liquid sorption and color stability of three different dental composites. Methodology: A total of 60 samples (n = 5) were examined from three composite materials: Omnichroma (Tokuyama Dental Co., Tokyo, Japan), Estelite Posterior, (Tokuyama Dental Co., Tokyo, Japan), and Mosaic Universal (Ultradent production Inc., South Jordan, UT, USA). Samples measuring 2x6 mm were taken and immersed in three different teas—Humana (Humana, Bremen, Germany), Hipp, (Hipp, Pfaffenhofen, Germany), and Lactamil (Nutricia, Friedrichsdorf, Germany) —as well as artificial saliva. The measurements were recorded at baseline and on the 7th day. A sensitive analytical balance was used to measure liquid sorption, and a VITA Easy Shade device was used for color measurements. Absorption and Delta E values were calculated. The data were analyzed using MANOVA at a significance level of (pResults: Composite materials, solutions, and their interactions had a statistically significant effect on the sorption and Delta E values (pMosaic>Omnichroma. Humana had the highest and Hipp had the lowest mean value among the solutions (pConclusion: Lactation teas cause discoloration in dental composites. In vitro and in vivo studies on color changes in dental composites are needed due to the sorption of these fluids. How to cite this article: Özüdoğru S, Tosun G. Survival and clinical evaluation of various space maintainers used for early primary tooth loss. Int Dent Res 2021;11(Suppl.1):222-7. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.32 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
- 30 September 2021
- Published by Zeus Publishing in International Dental Research
- Vol. 11 (Suppl. 1) , 228-233
Open AccessEvaluation of liquid sorption and color stability of dental composites after exposure to common lactation teas
Aim: To assess the effects of common lactation teas on liquid sorption and color stability of three different dental composites. Methodology: A total of 60 samples (n = 5) were examined from three composite materials: Omnichroma (Tokuyama Dental Co., Tokyo, Japan), Estelite Posterior, (Tokuyama Dental Co., Tokyo, Japan), and Mosaic Universal (Ultradent production Inc., South Jordan, UT, USA). Samples measuring 2x6 mm were taken and immersed in three different teas—Humana (Humana, Bremen, Germany), Hipp, (Hipp, Pfaffenhofen, Germany), and Lactamil (Nutricia, Friedrichsdorf, Germany) —as well as artificial saliva. The measurements were recorded at baseline and on the 7th day. A sensitive analytical balance was used to measure liquid sorption, and a VITA Easy Shade device was used for color measurements. Absorption and Delta E values were calculated. The data were analyzed using MANOVA at a significance level of (pResults: Composite materials, solutions, and their interactions had a statistically significant effect on the sorption and Delta E values (pMosaic>Omnichroma. Humana had the highest and Hipp had the lowest mean value among the solutions (pConclusion: Lactation teas cause discoloration in dental composites. In vitro and in vivo studies on color changes in dental composites are needed due to the sorption of these fluids. How to cite this article: Özüdoğru S, Tosun G. Survival and clinical evaluation of various space maintainers used for early primary tooth loss. Int Dent Res 2021;11(Suppl.1):222-7. https://doi.org/10.5577/intdentres.2021.vol11.suppl1.32 Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
- 1 August 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 124 (2) , 238.e1-238.e9
Influence of different surface treatments and universal adhesives on the repair of CAD-CAM composite resins: An in vitro study
- 1 August 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 124 (2) , 238.e1-238.e9
Influence of different surface treatments and universal adhesives on the repair of CAD-CAM composite resins: An in vitro study
- Open Access
- 1 January 2020
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 12 (1) , 22-32
Effect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials
Şişmanoğlu S, et al. J Adv Prosthodont. 2020 Feb;12(1):22-32. https://doi.org/10.4047/jap.2020.12.1.22
- 1 January 2020
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 12 (1) , 22-32
Open AccessEffect of surface treatments and universal adhesive application on the microshear bond strength of CAD/CAM materials
Şişmanoğlu S, et al. J Adv Prosthodont. 2020 Feb;12(1):22-32. https://doi.org/10.4047/jap.2020.12.1.22
- 9 December 2019
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 34 (10) , 1-13
Efficacy of different surface treatments and universal adhesives on the microtensile bond strength of bulk-fill composite repair
The purpose of this in vitro study was to evaluate the influence of different surface treatments and aging on the microtensile bond strength (μTBS) of bulk-fill composite resins. Bulk-fill composites (Filtek One; 3M ESPE) randomly received five different surface treatments: (1) no treatment, control, (2) 37% phosphoric acid etching (PA), (3) 9% hydrofluoric acid etching (HF), (4) air-borne particle abrasion with 50-μm alumina particles (Al2O3), (5) tribochemical silica coating (CoJet). Following, the specimens were divided into three subgroups according to universal adhesive applied: Clearfil Universal Bond (CU; Kuraray), Prime&Bond Universal (PBU; Dentsply Sirona), or Single Bond Universal (SBU; 3M ESPE). A nanofill composite (Filtek Ultimate; 3M ESPE) was employed as a repair. Bonded specimens were stored in water for 24 h at 37 °C or thermal aged, then subjected to the μTBS test. Additionally, specimens were analyzed with a contact profilometer and were evaluated with scanning electron microscopy. Control and PA treatments were showed the lowest µTBS (p < 0.05), and there was no significant difference between these two groups (p > 0.05). Al2O3 and CoJet treatments generally exhibited a similar influence on µTBS values. In addition, a correlation was found between surface roughness and bond strength (r = 0.831). CoJet resulted in significantly higher repair µTBS values when compared to the other surface treatments. In addition, the use of silane-containing universal adhesive was increased the cohesive failure rate and maintained the repair µTBS values after thermocycling.
- 9 December 2019
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 34 (10) , 1-13
Efficacy of different surface treatments and universal adhesives on the microtensile bond strength of bulk-fill composite repair
The purpose of this in vitro study was to evaluate the influence of different surface treatments and aging on the microtensile bond strength (μTBS) of bulk-fill composite resins. Bulk-fill composites (Filtek One; 3M ESPE) randomly received five different surface treatments: (1) no treatment, control, (2) 37% phosphoric acid etching (PA), (3) 9% hydrofluoric acid etching (HF), (4) air-borne particle abrasion with 50-μm alumina particles (Al2O3), (5) tribochemical silica coating (CoJet). Following, the specimens were divided into three subgroups according to universal adhesive applied: Clearfil Universal Bond (CU; Kuraray), Prime&Bond Universal (PBU; Dentsply Sirona), or Single Bond Universal (SBU; 3M ESPE). A nanofill composite (Filtek Ultimate; 3M ESPE) was employed as a repair. Bonded specimens were stored in water for 24 h at 37 °C or thermal aged, then subjected to the μTBS test. Additionally, specimens were analyzed with a contact profilometer and were evaluated with scanning electron microscopy. Control and PA treatments were showed the lowest µTBS (p < 0.05), and there was no significant difference between these two groups (p > 0.05). Al2O3 and CoJet treatments generally exhibited a similar influence on µTBS values. In addition, a correlation was found between surface roughness and bond strength (r = 0.831). CoJet resulted in significantly higher repair µTBS values when compared to the other surface treatments. In addition, the use of silane-containing universal adhesive was increased the cohesive failure rate and maintained the repair µTBS values after thermocycling.