RMRenata Marques de Melo

Renata Marques de Melo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Renata Marques de Melo has a total of 360 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fatigue lifetime and microbial inhibition at the implant–abutment interface of 5Y-PSZ zirconia abutments coated with experimental glass

    by Ana Carolina da Silva, Larissa Márcia Martins Alves, Ernesto Byron Benalcázar Jalkh, Juliana Campos Junqueira, Tiago Moreira Bastos Campos, Marco Antonio Bottino, Jason Alan Griggs, Estevam Augusto Bonfante, Renata Marques de Melo Marinho

  • Open Access

    3D Printing of Highly Dense and Translucent Zirconia Parts for Dental Applications: Effect of Filament Overlapping

    by Juliana de Freitas Gouveia Silva, Manuel Fellipe Rodrigues Pais Alves, Ana Carolina da Silva, Tiago Moreira Bastos Campos, Renata Marques De Melo, Susana Maria Henriques Olhero

    A 5Y‐PSZ zirconia paste was formulated for extrusion‐based additive manufacturing via Direct Ink Writing (DIW) to produce dense ceramic components for dental applications. A colloidal approach was adopted using nanometric zirconia powder (47 vol%) with tailored dispersant, thickener, and flocculant agents. Rheological behavior was evaluated by shear viscosity, viscoelastic moduli, and three‐step thixotropy tests to ensure printability and shape stability. Specimens were printed with different filament overlap percentages (20%, 25%, and 30%) and compared with a control group obtained by uniaxial pressing. After sintering, all groups were characterized in terms of relative density, microstructure (SEM), phase composition (XRD), translucency, and biaxial flexural strength. The 30% overlap printed group achieved average densification above 99%, optical translucency comparable to the pressed controls, and flexural strength of 432 ± 37 MPa. Weibull analysis of 30% filament overlap group indicated σ 0 = 420 MPa and m = 7.0, comparable to the pressed group (σ 0 = 658 MPa; m = 7.3). Overall, this study establishes a robust formulation and processing route for DIW of 5Y‐PSZ with high densification, translucency, and mechanical reliability, fulfilling ISO 6872 and offering a viable alternative for dental applications. This is the first study demonstrating filament overlaps as a densification‐enhancing parameter for DIW zirconia.


  • Ultra-translucent zirconia crowns with antimicrobial glass coatings: fatigue life and antagonist wear analysis

    by Ana Carolina da Silva, Juliana de Freitas Gouveia Silva, Tiago Moreira Bastos Campos, Gilmar Patrocínio Thim, Kartikeya Singh Jodha, Susana Maria Salazar Marocho, Renata Marques de Melo Marinho, Jason Alan Griggs


  • Open Access

    Pesticide drift: comparing spraying systems under variable field climatic conditions

    by Camila Rebelatto Muniz, Guilherme Braga Pereira Braz, Matheus De Freitas Souza, Indiamara Marasca, Camila Jorge Bernabé Ferreira, Renata Pereira Marques, Alaerson Maia Geraldine, Lais Regina Tereza Torquato Reginaldo

    Safe pesticide application must ensure efficacy in pest control while minimizing environmental and human health risks. This study investigated pesticide potential drift by comparing ground and aerial spraying systems under different climatic conditions. The research was conducted in Rio Verde, Goiás, Brazil, using a randomized block experimental design with 10 repetitions and a 2 x 2 split-plot scheme, considering spraying systems and climatic conditions as factors. Favorable and Unfavorable conditions were determined by relative air humidity, temperature, and wind speed. Aerial spraying was performed using a Cessna aircraft, while terrestrial spraying was done using a self-propelled Montana Parruda sprayer. Variables assessed included Volumetric Median Diameter (VMD), droplet density (DEN), and target coverage. Results revealed that aerial spraying has a higher drift potential, exceeding 180 m, compared to terrestrial spraying, limited to 90 m under unfavorable conditions. Although terrestrial spraying produces larger droplets, its shorter distance to the target and reduced speed minimize lateral movement, limiting drift potential. Droplet density and non-target area coverage were low for both systems, (0.1%). Under ideal conditions, aerial spraying is more efficient, but both methods require rigorous safety measures to prevent contamination risks. This study underlines the importance of considering droplet size and specific environmental conditions when choosing a spraying system, contributing to safer and more efficient agricultural practices. Highlights: Terrestrial spraying produces larger droplets which results in limited drift potential. Aerial spraying has a higher drift potential compared to terrestrial spraying. Aerial spraying is more efficient under favorable environmental conditions. For safer and more efficient agricultural practices it is important considering droplet size and specific environmental conditions.


  • Open Access

    Stress Distribution and Fatigue Behavior of Simplified Glass Ceramic Restorations: Effects of Curvature Ratio of Composite Resin Substrate and Restoration Assembly

    by Laura Viviana Calvache Arcila, Renan Vaz Machry, Amanda de Oliveira Pinto Ribeiro, Isabela Vitelli Tanaka, Guilherme Schmitt de Andrade, Alexandre Luiz Souto Borges, Luiz Felipe Valandro, Renata Marques de Melo

    This study investigated the effect of preparation curvature and leucite-reinforced glass-ceramic restorations on the fatigue behavior and stress distribution of the bonded ceramic restorations. Finite element analysis (FEA) was performed for the three experimental groups: flat preparation (Flat), preparation with a 2 mm radius of curvature (Curv1), and preparation with a 10 mm radius of curvature (Curv2). The Maximum Principal Stress (MPS) criterion was used to assess stress distribution. Then, resin composite discs were prepared to simulate the different curvatures (Flat, Curv1, and Curv2; n = 10), and leucite-reinforced glass-ceramic restorations with matching curvatures were bonded to them. Fatigue behavior was assessed using an accelerated fatigue test (10,000 cycles/step; 25 N increments; 20 Hz; initial load = 200 N). Fatigue failure load (FFL) and number of cycles for failure (CFF) were analyzed using Kaplan Meier analysis with post-hoc Mantel-Cox (log-rank) test (α = 0.05). The Flat group exhibited the lowest stress concentration (MPS = 4.5 MPa) on FEA, followed by Curv1 (MPS = 17.6 MPa) and Curv2 (MPS = 24 MPa). The Flat group also demonstrated the highest fatigue results (FFL = 632.50 MPa; CFF = 180,666 cycles). No statistically significant difference was found between Curv1 and Curv2 for fatigue values (FFL and CFF; Curv1 = 370.00 MPa and 72,510 cycles/Curv2 = 340.00 MPa and 61,000 cycles). Flat preparations improve the mechanical performance of bonded leucite-reinforced glass-ceramic restorations compared to curved preparations, which exhibit higher stress concentrations and reduced fatigue resistance.

  • Unraveling the antimicrobial mechanisms and multifunctional performance of boron-doped glass coatings on dental zirconias

    by Ana Carolina da Silva, Juliana de Freitas Gouveia Silva, Camila da Silva Rodrigues, Evelyn Luzia de Sousa Santos, Juliana Campos Junqueira, Tiago Moreira Bastos Campos, Gilmar Patrocínio Thim, Kartikeya Singh Jodha, Susana Maria Salazar Marocho, Jason Alan Griggs, et al.


  • Characterization of 3D printed composite for final dental restorations

    by Lucas Eigi Borges Tanaka, Camila da Silva Rodrigues, Manassés Tércio Vieira Grangeiro, Tiago Moreira Bastos Campos, Renata Marques de Melo

    Objectives This study evaluated the mechanical, optical, microstructural, surface, and adhesive behavior of a 3D printing resin comparing it with a machinable resin composite. Materials and methods Specimens of different sizes and shapes were either printed (Vitality, Smart Dent) or machinable (Grandio Blocs, Voco GmbH) resin composites with similar composition were prepared. Surface and mechanical characterization were performed with Knoop hardness, flexural strength (three-point-bending), and elastic modulus tests. The wear of the tested materials was evaluated against steatite antagonists. The optical properties stability (color change, ΔE00, and translucency, TP00) were observed after staining in red wine. In addition, the bond strength of the resin composites to two resin cement protocols were investigated with microshear bond strength tests at baseline and after thermocycling. Scanning electron microscope (SEM) coupled with Energy-Dispersive X-ray Spectroscopy (EDS) was used for microstructural and chemical characterization. Statistical analyses were performed with t- and ANOVA tests. Results Hardness values (132.76 (16.32) KH- Machinable and 35.87 (2.78) KH - Printed), flexural strength (172.17 (26.99) MPa - Machinable and 88.69 (8.39) MPa - Printed), color and translucency change (1.86 (0.31)/0.06 - Machinable and 3.73 (0.36)/9,16- Printed), and wear depth (24.97 mm (3.60)- Machinable and 7.16 mm (2.84) - Printed) were statistically different. Average Regarding bond strength, mean values (MPa) for non-aged and aged groups were respectively 21.76 (6.64) / 31.9 (12.66) for Bifix cement (Voco GmbH, Cuxhaven, Germany) and 26.75 (5.14) / 24.36 (6.85) for Variolink cement (Ivoclar Vivadent, Schaan, Liechtenstein) in Printed and 17.79 (3.89) / 9.01 (3.36) ) for Bifix cement and 22.09 (6.55) / 11.01 (3.77) for Variolink cement in Machinable materials. The material and aging factors did affect bond strength but the cement factor did not (p = 0.202). No statistical differences were observed for mean roughness (Ra) between materials. The better dispersion and larger size of the inorganic particles in the Machinable resin were contrasted with the clustered smaller particles of printed resin, under SEM. Conclusions The mechanical properties and color stability of the machinable resin were superior to those of the printed resin, probably due to the greater amount and dispersion of inorganic particles in the Mach resin, but bond strength after aging was stronger and more stable in the printed resin. Clinical relevance 3D-printed resin composites with similar compositions to machinable resin composites do not necessarily exhibit the same properties, which can impact clinical performance. Understanding these differences can assist manufacturers in improving their materials and help clinicians distinguish between materials appropriate for provisional and final restorations.


  • Open Access

    Fatigue behavior of sintered, glazed and glass-infiltrated surfaces of 5Y-PSZ bonded plates

    by Ana Carolina da Silva, Laura Patrícia Nadal Ortiz, Larissa Márcia Martins Alves, Kiara Serafini Dapieve, Tiago Moreira Bastos Campos, Marco Antonio Bottino, Gilmar Patrocínio Thim, Luiz Felipe Valandro, Renata Marques de Melo Marinho

    This study evaluated the effect of different occlusal surface finishes (glaze and silica glass infiltration) on surface characteristics and fatigue behavior of partially stabilized zirconia (PSZ) plates adhesively bonded onto epoxy resin discs. PSZ disc specimens (n = 15; Katana blocks STML, Kuraray Noritake Dental) were produced (Ø = 10 mm; thickness = 1.2 mm) and allocated into 3 groups: As sintered (S), silica glass infiltration (SGI), and glaze application (G). The PSZ intaglio surface was air-abraded with 50-µm alumina powder followed by bonding agent application. All produced PSZ were adhesively cemented onto dentin analogue discs made of epoxy resin material (Ø = 10 mm; thickness = 2 mm). Step stress fatigue test was performed (load ranging from 200 to 1800 N; step size 100 N and 10,000 cycles; 20 Hz). The topographic, microstructural, and fractographic analyses were performed by scanning electron microscopy. Results: No statistically significant difference in fatigue behavior was detected among the groups. All failures started at the bonding surface. Silica glass-infiltration and glaze layer application provided a smoothing effect, while the sintered group had a surface with grooves. The occlusal surface finishing method (silica glass infiltration or glazing) had no deleterious effect on fatigue behavior of adhesively bonded PSZ plates.


  • Open Access

    Effect of cementation protocols on the fracture load of bilayer ceramic crowns manufactured by the Rapid Layer Technology

    by Sarah Emille Gomes da Silva, Júlia M. Costa Lima, Elen G. Lima, Renata M. Melo, Marco A. Bottino, Rodrigo O. Assunção e Souza

    To evaluate the fracture load of bilayer ceramic crowns manufactured by Rapid Layer Technology (RLT) after different cementation protocols of the veneering ceramic to the zirconia infrastructures. Sixty epoxy resin preparations simulating a molar tooth were obtained and 60 zirconia infrastructures and feldspathic crowns were manufactured by RLT and divided into 6 groups according to the cementation protocol at the interface to veneering ceramic (n=10): Ctr- control: conventional resin cement; Al- Al2O3 sandblasting 50µm + conventional resin cement; Al/MDP- Al2O3 sandblasting (50µm) + resin cement with MDP; Sil- silicatization 30µm + conventional resin cement; Gl/HF- glaze + hydrofluoridric acid (5%,60s) + silane + conventional resin cement; Gl- glazing as bonding agent. The feldspathic ceramic internal surface was etched with fluoridric acid (5%) + silane followed by cementation according to respective protocols. All samples were mechanically cycled (200N and 4.5x105 Pa, 37°C, 2x106 cycles, 3.4Hz) and submitted to axial compressing fracture load test (10kN, 0.5mm/min). The results(N) were submitted to descriptive and analytical statistical analysis with 1-way ANOVA, Weibull, and the Tukey test (α=0.05). ANOVA revealed that there was a significant difference among the tested groups (p<0.0001). The group Al/MDP presented the higher resistance to fracture (1972.46A N), followed by the Ctr group (1584.41B N). The characteristic strength(σ0) was significantly different (p=0.000). The crack and chipping were the predominant failures. The air-abrasion at the external surface of zirconia with Al2O3 followed by cementation with MDP resin cement, should be selected to Rapid Layer Technique when felspathic ceramic is used as veneer ceramic.


  • Open Access

    Mechanical and optical properties of a borosilicate glass used to improve the finishing of 3Y-TZP restorations

    by Ana Carolina da Silva, Camila da Silva Rodrigues, Juliana de Freitas Gouveia Silva, Clarice Ferreira Sabino, Gilmar Patrocínio Thim, Renata Marques de Melo Marinho, Tiago Moreira Bastos Campos

    Borosilicate glass was developed to enhance the mechanical behavior and smoothness of dental zirconia as an alternative to conventional glaze. This study assessed the mechanical and optical properties of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) coated with borosilicate glass or a commercial glaze fired for an extended period of time. Disc-shaped 3Y-TZP zirconia specimens (Zpex, Tosoh) were sintered at 1550°C for 2 hours. The specimens were divided into three groups: as-sintered (control, C); commercial glaze (G); and borosilicate glass (SL). The glaze and borosilicate glass were applied over the zirconia and fired for 20 minutes at 950°C and 1200°C, respectively. Biaxial flexural strength, fractography, X-ray diffraction (XRD), roughness (Ra and Rz), fracture toughness (Vickers indentation method), color difference (∆E00), and translucency (TP00) analyses were conducted. The t-test or the one-way ANOVA and Tukey’s tests were used to analyze the data (α = 0.05). Flexural strength data were subjected to the Weibull analysis. The SL group exhibited the highest flexural strength (1025.8 MPa), whereas the C (859.41 MPa) and G (816.0 MPa) groups exhibited similar values. The SL group also had the highest characteristic strength. The fracture origin in all groups was on the zirconia surface. XRD analysis revealed that the specimens from the SL group contained tetragonal, cubic, and monoclinic phases. The SL group presented the lowest surface roughness. Fracture toughness in the SL group was lower than in the C group, but similar to that observed in the G group. The translucency and color differences observed in the G and SL groups were similar. Borosilicate glass enhanced the flexural strength of 3Y-TZP, promoted the smoothest surface, and exhibited optical properties similar to those of the glaze.