LFLouis Flynn

Louis Flynn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Louis Flynn has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Human-in-the-Loop Optimization of Wearable Robotic Devices to Improve Human–Robot Interaction: A Systematic Review

    by María Alejandra Díaz, Matthias Voß, Arnau Dillen, Bruno Tassignon, Louis Flynn, Joost Geeroms, Romain Meeusen, Tom Verstraten, Jan Babič, Philipp Beckerle, et al.

    This article presents a systematic review on wearable robotic devices that use human-in-the-loop optimization (HILO) strategies to improve human–robot interaction. A total of 46 HILO studies were identified and divided into upper and lower limb robotic devices. The main aspects from HILO were identified, reviewed, and classified in four areas: 1) human–machine systems; 2) optimization methods; 3) control strategies; and 4) experimental protocols. A variety of objective functions (physiological, biomechanical, and subjective), optimization strategies, and optimized control parameters configurations used in different control strategies are presented and analyzed. An overview of experimental protocols is provided, including metrics, tasks, and conditions tested. Moreover, the relevance given to training or adaptation periods was explored. We outline an HILO framework that includes current wearable robots, optimization strategies, objective functions, control strategies, and experimental protocols. We conclude by highlighting current research gaps and defining future directions to improve the development of advanced HILO strategies in upper and lower limb wearable robots.


  • Design and Evaluation of a Passive Cable-Driven Occupational Shoulder Exoskeleton

    by Marco Rossini, Sander De Bock, Arthur van der Have, Louis Flynn, David Rodriguez-Cianca, Kevin De Pauw, Dirk Lefeber, Joost Geeroms, Carlos Rodriguez-Guerrero

    Exoskeleton technologies have the potential to reduce the prevalence of work-related musculoskeletal disorders. Despite the fast-growing industrial exoskeleton market, several bottlenecks have prevented their wide application, namely the lack of wearability, the amount of assistance they deliver and their usefulness in various working scenarios, outside of those they were specifically designed to perform. In this work we present the design, realization and evaluation of a new wearable shoulder exoskeleton that is kinematically compatible with the glenohumeral joint and features a new passive remote actuation system (pRAS). The latter has a twofold function: it delivers assistance only when needed and allows for a more convenient repositioning of the exoskeleton components, reducing the exoskeleton’s footprint and limiting the weight on the user’s arm. A test bench has been designed to validate the mechanical performance of the shoulder exoskeleton and experiments have been conducted to investigate its effect on users while executing overhead working tasks. Based on the muscle activity monitored in six subjects, we conclude that our exoskeleton reduces anterior deltoid activity by 22% during the execution of overhead work. This preliminary study suggests that our device can successfully provide relief at the level of the shoulder without hindering the subject.


  • Guidelines and Recommendations to Investigate the Efficacy of a Lower-Limb Prosthetic Device: A Systematic Review

    by Jo Ghillebert, Sander De Bock, Louis Flynn, Joost Geeroms, Bruno Tassignon, Bart Roelands, Dirk Lefeber, Bram Vanderborght, Romain Meeusen, Kevin De Pauw

    INTRODUCTION Evaluating the efficacy of a lower-limb prosthetic device (LLPD) is a crucial step in the iterative process of redesigning and product development of new generation prostheses. To date, no standardized experimental methodology for the evaluation of LLPDs is available which complicates the comparison of results. OBJECTIVE This systematic review provides an overview of study designs, tests and outcome measures to evaluate a LLPD. Ultimately, guidelines and recommendations are formulated. METHODS Two databases were screened on studies evaluating a LLPD, published between 2009 and 2019. RESULTS 109 articles were eventually included. We identified 43 outcome measures in four main categories: 53% were biomechanical, 26% physiological, 14% physical performance and 7% psychological. Mainly walking tests were included (78%), of which 31% were performed on a slope, followed by stair climbing (15%) and other functional tasks (15%). CONCLUSION An overview of currently used study designs and experimental protocols is presented, which led to guidelines and recommendations for the evaluation of a LLPD. The main recommendation is to include daily activities in a case-report and in a later stage in a randomized controlled study design. Biomechanical, physiological, physical performance and psychological outcome measures are key for the evaluation of a LLPD.


  • Open Access

    The Challenges and Achievements of Experimental Implementation of an Active Transfemoral Prosthesis Based on Biological Quasi-Stiffness: The CYBERLEGs Beta-Prosthesis

    by Louis Flynn, Joost Geeroms, Rene Jimenez-Fabian, Sophie Heins, Bram Vanderborght, Marko Munih, Raffaele Molino Lova, Nicola Vitiello, Dirk Lefeber

    The CYBERLEGs Beta-Prosthesis is an active transfemoral prosthesis that can provide the full torque required for reproducing average level ground walking at both the knee and ankle in the sagittal plane. The prosthesis attempts to produce a natural level ground walking gait that approximates the joint torques and kinematics of a non-amputee while maintaining passively compliant joints, the stiffnesses of which were derived from biological quasi-stiffness measurements. The ankle of the prosthesis consists of a series elastic actuator with a parallel spring and the knee is composed of three different systems that must compliment each other to generate the correct joint behavior: a series elastic actuator, a lockable parallel spring and an energy transfer mechanism. Bench testing of this new prosthesis was completed and demonstrated that the device was able to create the expected torque-angle characteristics for a normal walker under ideal conditions. The experimental trials with four amputees walking on a treadmill to validate the behavior of the prosthesis proved that although the prosthesis could be controlled in a way that allowed all subjects to walk, the accurate timing and kinematic requirements of the output of the device limited the efficacy of using springs with quasi-static stiffnesses. Modification of the control and stiffness of the series springs could provide better performance in future work.


  • Torque control of an active elastic transfemoral prosthesis via quasi-static modelling

    by Sophie Heins, Louis Flynn, Joost Geeroms, Dirk Lefeber, Renaud Ronsse


  • Quasi-Static Modelling of a Redundant Knee Prosthesis

    by Sophie Heins, Louis Flynn, Joost Geeroms, Dirk Lefeber, Renaud Ronsse

    Developing mechanical devices to restore natural locomotion for transfemoral amputees still raises many challenges. One of them is the development of an efficient control strategy for the prosthesis active joints, with the objective of making it flexible and intuitive to use. This paper reports the modelling of the knee joint of the transfemoral CYBERLEGs Beta-Prosthesis, an actuated elastic ankle-knee prosthesis designed with the objective to minimize its total power consumption. More precisely, we report the static model of the prosthetic knee that was used to build its low-level controller, converting the desired torque into a reference position for the joint actuator. Bench testing of the prosthetic knee was performed to show that this static model is able to accurately predict the actual behaviour of the device.

  • On the Electrical Energy Consumption of Active Ankle Prostheses with Series and Parallel Elastic Elements

    by Tom Verstraten, Louis Flynn, Joost Geeroms, Bram Vanderborght, Dirk Lefeber

    With series and parallel elastic elements, considerable reductions in the mechanical peak power and energy consumption of active ankle prostheses can be obtained. Very few works, however, evaluate the electrical energy consumption of these devices. In this work, we analyze and discuss the differences between the mechanical and electrical energy consumption of these actuators. Design optimizations based on mechanical and electrical energy consumption are compared for a series elastic actuator, parallel elastic actuator and series elastic actuator with unidirectional spring. The results are then analyzed by means of torque-angle plots, power flow graphs and motor efficiency maps. The analysis highlights the impact of drivetrain inertia on the peak power and energy efficiency of the system. Moreover, interaction between the series spring and unidirectional parallel spring is identified as a potential cause of reduced actuator bandwidth. A parallel elastic actuator is found to be the most compact and energy-efficient solution overall as it makes the most efficient use of the electric motor.


  • Open Access

    VUB-CYBERLEGs CYBATHLON 2016 Beta-Prosthesis: case study in control of an active two degree of freedom transfemoral prosthesis

    by Louis L. Flynn, Joost Geeroms, Tom van der Hoeven, Bram Vanderborght, Dirk Lefeber

    Here we present how the CYBERLEGs Beta-Prosthesis was modified with a new control system to participate in the Powered Leg Prosthesis event, and to report on our experience at the CYBATHLON 2016 which was held in Zurich, Switzerland in October 2016. The prosthesis has two active degrees of freedom which assist the user with extra joint power at the knee and ankle to complete tasks. The CYBATHLON is a championship for people with disabilities competing in six disciplines, using advanced assistive devices. Tasks for CYBATHLON 2016 were chosen to reflect everyday normal task such as sitting and standing from a chair, obstacle avoidance, stepping stones, slope walking and descent, and stair climbing and descent. The control schemata were presented along with the description of each of the six tasks. The participant of the competition, the pilot, ran through each of the trials under lab conditions and representative behaviors were recorded. The VUB CYBERLEGs prosthesis was able to accomplish, to some degree, five of the six tasks and here the torque and angle behaviors of the device while accomplishing these tasks are presented. The relatively simple control methods were able to provide assistive torque during many of the events, particularly sit to stand and stair climbing. For example, the prosthesis was able to consistently provide over 30 Nm in arresting knee torque in the sitting task, and over 20 Nm while standing. Peak torque of the device was not sufficient for unassisted stair climbing, but was able to provide around 60 Nm of assistance in both ascent and descent. Use of the passive behaviors of the device were shown to be able to trigger state machine events reliably for certain tasks. Although the performance of the CYBERLEGs prosthesis during CYBATHLON 2016 did not compare to the other top of the market designs with regards to speed, the device performed all of the tasks that were deemed possible by the start of the competition. Moreover, the Pilot was able to accomplish tasks in ways the Pilot’s personal microcontrolled prosthesis could not, with limited powered prosthesis training. Future studies will focus on decreasing weight, increasing reliability, incorporating better control, and increasing the velocity of the device. This is only a case study and actual benefits to clinical outcomes are not yet understood and need to be further investigated. This competition was a unique experience to illuminate problems that future versions of the device will be able to solve.


  • Energetic analysis and optimization of a MACCEPA actuator in an ankle prosthesis

    by Joost Geeroms, Louis Flynn, Rene Jimenez-Fabian, Bram Vanderborght, Dirk Lefeber