Wei-Shiang Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei-Shiang Lin has a total of 164 co-authors. Here are the top co-authors by number of shared publications:
- Chin-Sheng Lin
Tri‐Service General Hospital, National Defense Medical University
7 shared publications - Chin Lin
School of Medicine, National Defense Medical Center, Taipei, Taiwan
6 shared publications - Shu-Meng Cheng
Division of Cardiology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical University, Taipei, Taiwan
5 shared publications - Tien-Ping Tsao
Division of Cardiovascular Medicine, Cheng Hsin General Hospital, No. 45, Zhenxing St., Beitou Dist., Taipei City, 112, Taiwan, ROC
5 shared publications - Cheng-Chung Cheng
Division of Cardiology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan
4 shared publications - Chien-Sung Tsai
Division of Cardiovascular surgery, Department of Surgery, Tri-Service General Hospital, National Defense Medical University, Taipei, Taiwan
4 shared publications
Latest Publications
- Open Access
- 7 November 2026
- Published by Wolters Kluwer Health in Circulation
Leveraging AI-ECG Technology for Early Notification and Tracking of AF Development (LATENT): A Randomized Controlled Trial
BACKGROUND: Electrocardiographic analysis aided by artificial intelligence (AI) may identify atrial electrical vulnerability during sinus rhythm. The objective of this study was to determine whether AI–enabled ECG (AI-ECG) is effective for detecting atrial fibrillation (AF), atrial flutter (AFl), or prespecified pre-AF atrial findings in a randomized trial. METHODS: In this single-center, open-label trial, 14 665 adults 40 to 85 years of age without previous AF/AFl were randomized to an AI-ECG–guided strategy or usual care. Participants randomized to AI-ECG who were then identified by AI as having a high-risk sinus-rhythm ECG in the preceding year were offered Holter monitoring for ≤7 days. Each monitored high-risk intervention participant was paired with an age- and sex-matched control selected before control ECGs underwent AI analysis. Matched controls received identical monitoring to reduce ascertainment bias. Reporting cardiologists were blinded to AI results and randomized assignment. The primary outcome was a composite of newly detected AF, AFl, or pre-AF atrial findings within 90 days. Pre-AF atrial findings comprised frequent premature atrial complexes, short runs of premature atrial complexes, or nonsustained AF/AFl. RESULTS: Among 7337 intervention and 7328 control participants, 84 (1.1%) and 78 (1.1%), respectively, were classified as high risk. Of the 84 high-risk intervention participants, 48 (57.1%) underwent monitoring, as did 48 matched controls. The primary outcome occurred in 54 intervention participants (0.74%) versus 35 control participants (0.48%; odds ratio, 1.54 [95% CI, 1.01–2.37]; P =0.046). Hypothetical reclassification of 1 intervention event to a nonevent changed the primary analysis P value to 0.057. The intervention effect on detection of the primary composite outcome differed by baseline AI-ECG risk ( P interaction <0.001): 32.1% versus 2.6% among high-risk participants and 0.4% versus 0.5% among low-risk participants. AF/AFl detection (0.3% versus 0.2%) and antiarrhythmic therapy initiation at 180 days (2.3% versus 2.4%) did not differ significantly between the intervention and control groups. Participant-reported monitoring-related adverse events, including skin reactions and discomfort, occurred in 22.9% of monitored intervention participants versus 18.8% of matched controls. CONCLUSIONS: AI-ECG–guided monitoring resulted in a modest increase in the detection of new AF, AFl, or pre-AF atrial findings. However, these findings were fragile statistically and sensitive to reclassification of 1 event. LATENT (Leveraging AI-ECG Technology for Early Notification and Tracking of AF Development) demonstrates the clinical application of AI-ECG risk stratification to guide targeted rhythm surveillance, providing a foundation for larger trials evaluating its impact on patient outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT06847932.
- 7 November 2026
- Published by Wolters Kluwer Health in Circulation
Open AccessLeveraging AI-ECG Technology for Early Notification and Tracking of AF Development (LATENT): A Randomized Controlled Trial
BACKGROUND: Electrocardiographic analysis aided by artificial intelligence (AI) may identify atrial electrical vulnerability during sinus rhythm. The objective of this study was to determine whether AI–enabled ECG (AI-ECG) is effective for detecting atrial fibrillation (AF), atrial flutter (AFl), or prespecified pre-AF atrial findings in a randomized trial. METHODS: In this single-center, open-label trial, 14 665 adults 40 to 85 years of age without previous AF/AFl were randomized to an AI-ECG–guided strategy or usual care. Participants randomized to AI-ECG who were then identified by AI as having a high-risk sinus-rhythm ECG in the preceding year were offered Holter monitoring for ≤7 days. Each monitored high-risk intervention participant was paired with an age- and sex-matched control selected before control ECGs underwent AI analysis. Matched controls received identical monitoring to reduce ascertainment bias. Reporting cardiologists were blinded to AI results and randomized assignment. The primary outcome was a composite of newly detected AF, AFl, or pre-AF atrial findings within 90 days. Pre-AF atrial findings comprised frequent premature atrial complexes, short runs of premature atrial complexes, or nonsustained AF/AFl. RESULTS: Among 7337 intervention and 7328 control participants, 84 (1.1%) and 78 (1.1%), respectively, were classified as high risk. Of the 84 high-risk intervention participants, 48 (57.1%) underwent monitoring, as did 48 matched controls. The primary outcome occurred in 54 intervention participants (0.74%) versus 35 control participants (0.48%; odds ratio, 1.54 [95% CI, 1.01–2.37]; P =0.046). Hypothetical reclassification of 1 intervention event to a nonevent changed the primary analysis P value to 0.057. The intervention effect on detection of the primary composite outcome differed by baseline AI-ECG risk ( P interaction <0.001): 32.1% versus 2.6% among high-risk participants and 0.4% versus 0.5% among low-risk participants. AF/AFl detection (0.3% versus 0.2%) and antiarrhythmic therapy initiation at 180 days (2.3% versus 2.4%) did not differ significantly between the intervention and control groups. Participant-reported monitoring-related adverse events, including skin reactions and discomfort, occurred in 22.9% of monitored intervention participants versus 18.8% of matched controls. CONCLUSIONS: AI-ECG–guided monitoring resulted in a modest increase in the detection of new AF, AFl, or pre-AF atrial findings. However, these findings were fragile statistically and sensitive to reclassification of 1 event. LATENT (Leveraging AI-ECG Technology for Early Notification and Tracking of AF Development) demonstrates the clinical application of AI-ECG risk stratification to guide targeted rhythm surveillance, providing a foundation for larger trials evaluating its impact on patient outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT06847932.
- 29 April 2025
- Published by Taylor & Francis in Psychology, Health & Medicine
- Vol. 30 (7) , 1353-1372
Eye movement desensitization and reprocessing (EMDR) improves symptoms of anxiety and depression, blood pressure, and heart rate variability in patients with hypertension: a randomized controlled trial
Bidirectional associations have been demonstrated between negative emotions, such as anxiety and depression, and hypertension, which can lower quality of life and increase mortality. Eye movement desensitization and reprocessing (EMDR) has been recognized as a successful intervention for individuals experiencing significant psychological distress. This study aimed to investigate the impact of an eye movement desensitization and reprocessing intervention for patients with hypertension on improving symptoms of anxiety and depression, blood pressure, and heart rate variability (HRV). This longitudinal randomized controlled trial consecutively enrolled patients with hypertension. Patients were randomly divided into two groups: one group received the EMDR intervention (n = 50); the control group received routine care (n = 52). Data were collected at four different time points: pre-intervention (T0), immediately post-intervention (T1), and at one-month and three-month follow-ups (T2 and T3, respectively). Data were analysed using the generalized estimating equation. At T1, when compared with the control group, patients in the intervention group showed substantial improvements in systolic blood pressure and measures of HRV such as low frequency, high frequency, and ratios of low frequency/high frequency (all p < .01). Symptoms of anxiety were also significantly more decreased compared with controls (p < 0.001). Improvements in symptoms of anxiety and hypertension following EMDR suggest this should be considered as a clinical treatment option for this at-risk group of patients.
- 29 April 2025
- Published by Taylor & Francis in Psychology, Health & Medicine
- Vol. 30 (7) , 1353-1372
Eye movement desensitization and reprocessing (EMDR) improves symptoms of anxiety and depression, blood pressure, and heart rate variability in patients with hypertension: a randomized controlled trial
Bidirectional associations have been demonstrated between negative emotions, such as anxiety and depression, and hypertension, which can lower quality of life and increase mortality. Eye movement desensitization and reprocessing (EMDR) has been recognized as a successful intervention for individuals experiencing significant psychological distress. This study aimed to investigate the impact of an eye movement desensitization and reprocessing intervention for patients with hypertension on improving symptoms of anxiety and depression, blood pressure, and heart rate variability (HRV). This longitudinal randomized controlled trial consecutively enrolled patients with hypertension. Patients were randomly divided into two groups: one group received the EMDR intervention (n = 50); the control group received routine care (n = 52). Data were collected at four different time points: pre-intervention (T0), immediately post-intervention (T1), and at one-month and three-month follow-ups (T2 and T3, respectively). Data were analysed using the generalized estimating equation. At T1, when compared with the control group, patients in the intervention group showed substantial improvements in systolic blood pressure and measures of HRV such as low frequency, high frequency, and ratios of low frequency/high frequency (all p < .01). Symptoms of anxiety were also significantly more decreased compared with controls (p < 0.001). Improvements in symptoms of anxiety and hypertension following EMDR suggest this should be considered as a clinical treatment option for this at-risk group of patients.
- Open Access
- 1 July 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (7) , 1574
Klotho Modulates Pro-Fibrotic Activities in Human Atrial Fibroblasts through Inhibition of Phospholipase C Signaling and Suppression of Store-Operated Calcium Entry
Background: Atrial fibroblasts activation causes atrial fibrosis, which is one major pathophysiological contributor to atrial fibrillation (AF) genesis. Klotho is a pleiotropic protein with remarkable cardiovascular effects, including anti-inflammatory, anti-oxidative, and anti-apoptotic effects. This study investigated whether Klotho can modulate the activity of human atrial fibroblasts and provides an anti-fibrotic effect. Methods: Cell migration assay and proliferation assay were used to investigate fibrogenesis activities in single human atrial fibroblasts with or without treatment of Klotho (10 and 100 pM, 48 h). Calcium fluorescence imaging, the whole-cell patch-clamp, and Western blotting were performed in human atrial fibroblasts treated with and without Klotho (100 pM, 48 h) to evaluate the store-operated calcium entry (SOCE), transient receptor potential (TRP) currents, and downstream signaling. Results: High dose of Klotho (100 pM, 48 h) significantly reduced the migration of human atrial fibroblasts without alternating their proliferation; in addition, treatment of Klotho (100 pM, 48 h) also decreased SOCE and TRP currents. In the presence of BI-749327 (a selective canonical TRP 6 channel inhibitor, 1 μM, 48 h), Klotho (100 pM, 48 h) could not inhibit fibroblast migration nor suppress the TRP currents. Klotho-treated fibroblasts (100 pM, 48 h) had lower phosphorylated phospholipase C (PLC) (p-PLCβ3 Ser537) expression than the control. The PLC inhibitor, U73122 (1 μM, 48 h), reduced the migration, decreased SOCE and TRP currents, and lowered p-PLCβ3 in atrial fibroblasts, similar to Klotho. In the presence of the U73122 (1 μM, 48 h), Klotho (100 pM, 48 h) could not further modulate the migration and collagen synthesis nor suppress the TRP currents in human atrial fibroblasts. Conclusions: Klotho inhibited pro-fibrotic activities and SOCE by inhibiting the PLC signaling and suppressing the TRP currents, which may provide a novel insight into atrial fibrosis and arrhythmogenesis.
- 1 July 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (7) , 1574
Open AccessKlotho Modulates Pro-Fibrotic Activities in Human Atrial Fibroblasts through Inhibition of Phospholipase C Signaling and Suppression of Store-Operated Calcium Entry
Background: Atrial fibroblasts activation causes atrial fibrosis, which is one major pathophysiological contributor to atrial fibrillation (AF) genesis. Klotho is a pleiotropic protein with remarkable cardiovascular effects, including anti-inflammatory, anti-oxidative, and anti-apoptotic effects. This study investigated whether Klotho can modulate the activity of human atrial fibroblasts and provides an anti-fibrotic effect. Methods: Cell migration assay and proliferation assay were used to investigate fibrogenesis activities in single human atrial fibroblasts with or without treatment of Klotho (10 and 100 pM, 48 h). Calcium fluorescence imaging, the whole-cell patch-clamp, and Western blotting were performed in human atrial fibroblasts treated with and without Klotho (100 pM, 48 h) to evaluate the store-operated calcium entry (SOCE), transient receptor potential (TRP) currents, and downstream signaling. Results: High dose of Klotho (100 pM, 48 h) significantly reduced the migration of human atrial fibroblasts without alternating their proliferation; in addition, treatment of Klotho (100 pM, 48 h) also decreased SOCE and TRP currents. In the presence of BI-749327 (a selective canonical TRP 6 channel inhibitor, 1 μM, 48 h), Klotho (100 pM, 48 h) could not inhibit fibroblast migration nor suppress the TRP currents. Klotho-treated fibroblasts (100 pM, 48 h) had lower phosphorylated phospholipase C (PLC) (p-PLCβ3 Ser537) expression than the control. The PLC inhibitor, U73122 (1 μM, 48 h), reduced the migration, decreased SOCE and TRP currents, and lowered p-PLCβ3 in atrial fibroblasts, similar to Klotho. In the presence of the U73122 (1 μM, 48 h), Klotho (100 pM, 48 h) could not further modulate the migration and collagen synthesis nor suppress the TRP currents in human atrial fibroblasts. Conclusions: Klotho inhibited pro-fibrotic activities and SOCE by inhibiting the PLC signaling and suppressing the TRP currents, which may provide a novel insight into atrial fibrosis and arrhythmogenesis.
- 15 February 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (4) , 3317-3326
A deep learning-based system capable of detecting pneumothorax via electrocardiogram
Purpose To determine if an electrocardiogram-based artificial intelligence system can identify pneumothorax prior to radiological examination. Methods This is a single-center, retrospective, electrocardiogram-based artificial intelligence (AI) system study that included 107 ECGs from 98 pneumothorax patients. Seven patients received needle decompression due to tension pneumothorax, and the others received thoracostomy due to instability (respiratory rate ≥ 24 breaths/min; heart rate, < 60 beats/min or > 120 beats/min; hypotension; room air O2 saturation, < 90%; and patient could not speak in whole sentences between breaths). Traumatic pneumothorax and bilateral pneumothorax were excluded. The ECGs of 132,127 patients presenting to the emergency department without pneumothorax were used as the control group. The development cohort included approximately 80% of the ECGs for training the deep learning model (DLM), and the other 20% of ECGs were used to validate the performance. A human–machine competition involving three physicians was conducted to assess the model performance. Results The areas under the receiver operating characteristic (ROC) curves (AUCs) of the DLM in the validation cohort and competition set were 0.947 and 0.957, respectively. The sensitivity and specificity of our DLM were 94.7% and 88.1% in the validation cohort, respectively, which were significantly higher than those of all physicians. Our DLM could also recognize the location of pneumothorax with 100% accuracy. Lead-specific analysis showed that lead I ECG made a major contribution, achieving an AUC of 0.930 (94.7% sensitivity, 86.0% specificity). The inclusion of the patient characteristics allowed our AI system to achieve an AUC of 0.994. Conclusion The present AI system may assist the medical system in the early identification of pneumothorax through 12-lead ECG, and it performs as well with lead I ECG alone as with 12-lead ECG.
- 15 February 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (4) , 3317-3326
A deep learning-based system capable of detecting pneumothorax via electrocardiogram
Purpose To determine if an electrocardiogram-based artificial intelligence system can identify pneumothorax prior to radiological examination. Methods This is a single-center, retrospective, electrocardiogram-based artificial intelligence (AI) system study that included 107 ECGs from 98 pneumothorax patients. Seven patients received needle decompression due to tension pneumothorax, and the others received thoracostomy due to instability (respiratory rate ≥ 24 breaths/min; heart rate, < 60 beats/min or > 120 beats/min; hypotension; room air O2 saturation, < 90%; and patient could not speak in whole sentences between breaths). Traumatic pneumothorax and bilateral pneumothorax were excluded. The ECGs of 132,127 patients presenting to the emergency department without pneumothorax were used as the control group. The development cohort included approximately 80% of the ECGs for training the deep learning model (DLM), and the other 20% of ECGs were used to validate the performance. A human–machine competition involving three physicians was conducted to assess the model performance. Results The areas under the receiver operating characteristic (ROC) curves (AUCs) of the DLM in the validation cohort and competition set were 0.947 and 0.957, respectively. The sensitivity and specificity of our DLM were 94.7% and 88.1% in the validation cohort, respectively, which were significantly higher than those of all physicians. Our DLM could also recognize the location of pneumothorax with 100% accuracy. Lead-specific analysis showed that lead I ECG made a major contribution, achieving an AUC of 0.930 (94.7% sensitivity, 86.0% specificity). The inclusion of the patient characteristics allowed our AI system to achieve an AUC of 0.994. Conclusion The present AI system may assist the medical system in the early identification of pneumothorax through 12-lead ECG, and it performs as well with lead I ECG alone as with 12-lead ECG.
- Open Access
- 16 November 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (22) , 5337
Clinical Events with Edoxaban in South Korean and Taiwanese Atrial Fibrillation Patients in Routine Clinical Practice
Edoxaban is approved for stroke prevention in nonvalvular atrial fibrillation (AF) patients in numerous countries. Outcome data are sparse on edoxaban treatment in AF patients from routine clinical practice, especially in Asian patients. Global ETNA (Edoxaban in rouTine cliNical prActice) is a noninterventional study that integrates data from patients from multiple regional registries into one database. Here, we report the 1-year clinical events from AF patients receiving edoxaban in South Korea and Taiwan. Clinical events assessed included bleeding, strokes, systemic embolic events, transient ischemic attacks (TIAs), and all-cause and cardiovascular death. Overall, 2677 patients (mean (range) age 72 (66–78) years, male 59.7%, mean CHA2DS2-VASc score ± standard deviation 3.1 ± 1.4) were treated with 60 or 30 mg edoxaban and had 1-year follow-up data. The annualized event rates for major bleeding and clinically relevant non-major (CRNM) bleeding were 0.78% and 0.47%, respectively. Annualized event rates for ischemic stroke and hemorrhagic stroke were 0.90% and 0.19%, respectively. Event rates for major and CRNM bleeding and rates of ischemic stroke and TIA were higher in Taiwanese patients than in Korean patients. Event rates were low and similar to those found in other studies of edoxaban in Korean and Taiwanese AF patients, thus supporting the safety and effectiveness of edoxaban in this population.
- 16 November 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (22) , 5337
Open AccessClinical Events with Edoxaban in South Korean and Taiwanese Atrial Fibrillation Patients in Routine Clinical Practice
Edoxaban is approved for stroke prevention in nonvalvular atrial fibrillation (AF) patients in numerous countries. Outcome data are sparse on edoxaban treatment in AF patients from routine clinical practice, especially in Asian patients. Global ETNA (Edoxaban in rouTine cliNical prActice) is a noninterventional study that integrates data from patients from multiple regional registries into one database. Here, we report the 1-year clinical events from AF patients receiving edoxaban in South Korea and Taiwan. Clinical events assessed included bleeding, strokes, systemic embolic events, transient ischemic attacks (TIAs), and all-cause and cardiovascular death. Overall, 2677 patients (mean (range) age 72 (66–78) years, male 59.7%, mean CHA2DS2-VASc score ± standard deviation 3.1 ± 1.4) were treated with 60 or 30 mg edoxaban and had 1-year follow-up data. The annualized event rates for major bleeding and clinically relevant non-major (CRNM) bleeding were 0.78% and 0.47%, respectively. Annualized event rates for ischemic stroke and hemorrhagic stroke were 0.90% and 0.19%, respectively. Event rates for major and CRNM bleeding and rates of ischemic stroke and TIA were higher in Taiwanese patients than in Korean patients. Event rates were low and similar to those found in other studies of edoxaban in Korean and Taiwanese AF patients, thus supporting the safety and effectiveness of edoxaban in this population.
- Open Access
- 4 November 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (11) , 1149
An Artificial Intelligence-Based Alarm Strategy Facilitates Management of Acute Myocardial Infarction
(1) Background: While an artificial intelligence (AI)-based, cardiologist-level, deep-learning model for detecting acute myocardial infarction (AMI), based on a 12-lead electrocardiogram (ECG), has been established to have extraordinary capabilities, its real-world performance and clinical applications are currently unknown. (2) Methods and Results: To set up an artificial intelligence-based alarm strategy (AI-S) for detecting AMI, we assembled a strategy development cohort including 25,002 visits from August 2019 to April 2020 and a prospective validation cohort including 14,296 visits from May to August 2020 at an emergency department. The components of AI-S consisted of chest pain symptoms, a 12-lead ECG, and high-sensitivity troponin I. The primary endpoint was to assess the performance of AI-S in the prospective validation cohort by evaluating F-measure, precision, and recall. The secondary endpoint was to evaluate the impact on door-to-balloon (DtoB) time before and after AI-S implementation in STEMI patients treated with primary percutaneous coronary intervention (PPCI). Patients with STEMI were alerted precisely by AI-S (F-measure = 0.932, precision of 93.2%, recall of 93.2%). Strikingly, in comparison with pre-AI-S (N = 57) and post-AI-S (N = 32) implantation in STEMI protocol, the median ECG-to-cardiac catheterization laboratory activation (EtoCCLA) time was significantly reduced from 6.0 (IQR, 5.0–8.0 min) to 4.0 min (IQR, 3.0–5.0 min) (p < 0.01). The median DtoB time was shortened from 69 (IQR, 61.0–82.0 min) to 61 min (IQR, 56.8–73.2 min) (p = 0.037). (3) Conclusions: AI-S offers front-line physicians a timely and reliable diagnostic decision-support system, thereby significantly reducing EtoCCLA and DtoB time, and facilitating the PPCI process. Nevertheless, large-scale, multi-institute, prospective, or randomized control studies are necessary to further confirm its real-world performance.
- 4 November 2021
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 11 (11) , 1149
Open AccessAn Artificial Intelligence-Based Alarm Strategy Facilitates Management of Acute Myocardial Infarction
(1) Background: While an artificial intelligence (AI)-based, cardiologist-level, deep-learning model for detecting acute myocardial infarction (AMI), based on a 12-lead electrocardiogram (ECG), has been established to have extraordinary capabilities, its real-world performance and clinical applications are currently unknown. (2) Methods and Results: To set up an artificial intelligence-based alarm strategy (AI-S) for detecting AMI, we assembled a strategy development cohort including 25,002 visits from August 2019 to April 2020 and a prospective validation cohort including 14,296 visits from May to August 2020 at an emergency department. The components of AI-S consisted of chest pain symptoms, a 12-lead ECG, and high-sensitivity troponin I. The primary endpoint was to assess the performance of AI-S in the prospective validation cohort by evaluating F-measure, precision, and recall. The secondary endpoint was to evaluate the impact on door-to-balloon (DtoB) time before and after AI-S implementation in STEMI patients treated with primary percutaneous coronary intervention (PPCI). Patients with STEMI were alerted precisely by AI-S (F-measure = 0.932, precision of 93.2%, recall of 93.2%). Strikingly, in comparison with pre-AI-S (N = 57) and post-AI-S (N = 32) implantation in STEMI protocol, the median ECG-to-cardiac catheterization laboratory activation (EtoCCLA) time was significantly reduced from 6.0 (IQR, 5.0–8.0 min) to 4.0 min (IQR, 3.0–5.0 min) (p < 0.01). The median DtoB time was shortened from 69 (IQR, 61.0–82.0 min) to 61 min (IQR, 56.8–73.2 min) (p = 0.037). (3) Conclusions: AI-S offers front-line physicians a timely and reliable diagnostic decision-support system, thereby significantly reducing EtoCCLA and DtoB time, and facilitating the PPCI process. Nevertheless, large-scale, multi-institute, prospective, or randomized control studies are necessary to further confirm its real-world performance.
- Open Access
- 29 October 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (21) , 5093
Prognostic Analysis of Patients with Acute Myocardial Infarction Undergoing Implantation of Different Stents for the First Time
For patients with acute myocardial infarction scheduled to undergo percutaneous coronary stent implantation, in most cases a drug-eluting stent is recommended as the first choice for treatment. However, there is a lack of research on the effectiveness of bare-metal stents and drug-eluting stents on patients with different types of myocardial infarction. Our objective was to explore the effects of bare-metal stents and drug-eluting stents on patients with different types of myocardial infarction in terms of major cardiovascular incidents. This retrospective cohort study included 934 patients with myocardial infarction undergoing coronary artery stent implantation for the first time at the cardiac catheter room of the Tri-Service General Hospital in the Neihu District between 2014 and 2018. Patients’ information, including demographic data, laboratory data, cardiac echocardiography results, and angiocardiography results, was collected by reviewing medical records. Cox proportional hazards regression was used to adjust the potential confounding factors, and the adjusted data were then used to compare the correlation between different types of stents and major cardiovascular incidents in patients with ST-elevation myocardial infarction and non-ST-elevation myocardial infarction. After the confounding factors were adjusted, in patients with ST-elevation myocardial infarction receiving a drug-eluting stent compared with those receiving a bare-metal stent, it was found that the mortality risk was lower in terms of all causes of death (Adj-HR = 0.26, 95% CI = 0.14–0.48, p < 0.001) and cardiogenic death (Adj-HR = 0.20, 95% CI = 0.08–0.55, p = 0.002), the risk of non-fatal myocardial infarction was lower (Adj-HR = 0.17, 95% CI = 0.04–0.73, p = 0.017), and there was no difference in the risk of revascularization at the lesion site (Adj-HR = 0.59, 95% CI = 0.24–1.43, p = 0.243). It terms of the findings in patients with non-ST-elevation myocardial infarction, those receiving a drug-eluting stent had a lower risk of revascularization at the lesion site (Adj-HR = 0.48, 95% CI = 0.24–0.97, p = 0.04); however, there was no difference in the mortality risk in terms of all causes of death (Adj-HR = 0.71, 95% CI = 0.37–1.35, p = 0.296) or cardiogenic death (Adj-HR = 0.59, 95% CI = 0.18–1.90, p = 0.379),or in the risk of non-fatal myocardial infarction (Adj-HR = 0.27, 95% CI = 0.06–1.25, p = 0.093). Compared with bare-metal stents, drug-eluting stents provide better protection against death to receivers with ST-elevation myocardial infarction; however, this protection is decreased in receivers with non-ST-elevation myocardial infarction. It is recommended that for patients with non-ST-elevation myocardial infarction who are indicated to receive a drug-eluting stent, the clinical effectiveness of the treatment must be considered.
- 29 October 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (21) , 5093
Open AccessPrognostic Analysis of Patients with Acute Myocardial Infarction Undergoing Implantation of Different Stents for the First Time
For patients with acute myocardial infarction scheduled to undergo percutaneous coronary stent implantation, in most cases a drug-eluting stent is recommended as the first choice for treatment. However, there is a lack of research on the effectiveness of bare-metal stents and drug-eluting stents on patients with different types of myocardial infarction. Our objective was to explore the effects of bare-metal stents and drug-eluting stents on patients with different types of myocardial infarction in terms of major cardiovascular incidents. This retrospective cohort study included 934 patients with myocardial infarction undergoing coronary artery stent implantation for the first time at the cardiac catheter room of the Tri-Service General Hospital in the Neihu District between 2014 and 2018. Patients’ information, including demographic data, laboratory data, cardiac echocardiography results, and angiocardiography results, was collected by reviewing medical records. Cox proportional hazards regression was used to adjust the potential confounding factors, and the adjusted data were then used to compare the correlation between different types of stents and major cardiovascular incidents in patients with ST-elevation myocardial infarction and non-ST-elevation myocardial infarction. After the confounding factors were adjusted, in patients with ST-elevation myocardial infarction receiving a drug-eluting stent compared with those receiving a bare-metal stent, it was found that the mortality risk was lower in terms of all causes of death (Adj-HR = 0.26, 95% CI = 0.14–0.48, p < 0.001) and cardiogenic death (Adj-HR = 0.20, 95% CI = 0.08–0.55, p = 0.002), the risk of non-fatal myocardial infarction was lower (Adj-HR = 0.17, 95% CI = 0.04–0.73, p = 0.017), and there was no difference in the risk of revascularization at the lesion site (Adj-HR = 0.59, 95% CI = 0.24–1.43, p = 0.243). It terms of the findings in patients with non-ST-elevation myocardial infarction, those receiving a drug-eluting stent had a lower risk of revascularization at the lesion site (Adj-HR = 0.48, 95% CI = 0.24–0.97, p = 0.04); however, there was no difference in the mortality risk in terms of all causes of death (Adj-HR = 0.71, 95% CI = 0.37–1.35, p = 0.296) or cardiogenic death (Adj-HR = 0.59, 95% CI = 0.18–1.90, p = 0.379),or in the risk of non-fatal myocardial infarction (Adj-HR = 0.27, 95% CI = 0.06–1.25, p = 0.093). Compared with bare-metal stents, drug-eluting stents provide better protection against death to receivers with ST-elevation myocardial infarction; however, this protection is decreased in receivers with non-ST-elevation myocardial infarction. It is recommended that for patients with non-ST-elevation myocardial infarction who are indicated to receive a drug-eluting stent, the clinical effectiveness of the treatment must be considered.
- 18 October 2021
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 52 (4) , e13690
Ceramide modulates electrophysiological characteristics and oxidative stress of pulmonary vein cardiomyocytes
Background: Ceramide is involved in regulating metabolism and energy expenditure, and its abnormal myocardial accumulation may contribute to heart injury or lipotoxic cardiomyopathy. Whether ceramide can modulate the electrophysiology of pulmonary veins (PVs) remains unknown.Materials and methods: We used conventional microelectrodes to measure the electrical activity of isolated rabbit PV tissue preparations before and after treatment with various concentrations of ceramide with or without H2O2 (2 mM), MitoQ, wortmannin or 740 YP. A whole‐cell patch clamp and fluorescence imaging were used to record the ionic currents, calcium (Ca2+) transients, and intracellular reactive oxygen species (ROS) and sodium (Na+) in isolated single PV cardiomyocytes before and after ceramide (1 μM) treatment.Results: Ceramide (0.1, 0.3, 1 and 3 μM) reduced the beating rate of PV tissues. Furthermore, ceramide (1 μM) suppressed the 2 mM H2O2‐induced faster PV beating rate, triggered activities and burst firings, which were further reduced by MitoQ. In the presence of wortmannin, ceramide did not change the PV beating rate. The H2O2‐induced faster PV beating rate could be counteracted by MitoQ or wortmannin with no additive effect from the ceramide. Ceramide inhibited pPI3K. Ceramide reduced Ca2+ transients, sarcoplasmic reticulum Ca2+ contents, L‐type Ca2+ currents, Na+ currents, late Na+ currents, Na+‐hydrogen exchange currents, and intracellular ROS and Na+ in PV cardiomyocytes, but did not change Na+‐Ca2+ exchange currents.Conclusion: C2 ceramide may exert the distinctive electrophysiological effect of modulating PV activities, which may be affected by PI3K pathway–mediated oxidative stress, and might play a role in the pathogenesis of PV arrhythmogenesis.
- 18 October 2021
- Published by Wiley in European Journal of Clinical Investigation
- Vol. 52 (4) , e13690
Ceramide modulates electrophysiological characteristics and oxidative stress of pulmonary vein cardiomyocytes
Background: Ceramide is involved in regulating metabolism and energy expenditure, and its abnormal myocardial accumulation may contribute to heart injury or lipotoxic cardiomyopathy. Whether ceramide can modulate the electrophysiology of pulmonary veins (PVs) remains unknown.Materials and methods: We used conventional microelectrodes to measure the electrical activity of isolated rabbit PV tissue preparations before and after treatment with various concentrations of ceramide with or without H2O2 (2 mM), MitoQ, wortmannin or 740 YP. A whole‐cell patch clamp and fluorescence imaging were used to record the ionic currents, calcium (Ca2+) transients, and intracellular reactive oxygen species (ROS) and sodium (Na+) in isolated single PV cardiomyocytes before and after ceramide (1 μM) treatment.Results: Ceramide (0.1, 0.3, 1 and 3 μM) reduced the beating rate of PV tissues. Furthermore, ceramide (1 μM) suppressed the 2 mM H2O2‐induced faster PV beating rate, triggered activities and burst firings, which were further reduced by MitoQ. In the presence of wortmannin, ceramide did not change the PV beating rate. The H2O2‐induced faster PV beating rate could be counteracted by MitoQ or wortmannin with no additive effect from the ceramide. Ceramide inhibited pPI3K. Ceramide reduced Ca2+ transients, sarcoplasmic reticulum Ca2+ contents, L‐type Ca2+ currents, Na+ currents, late Na+ currents, Na+‐hydrogen exchange currents, and intracellular ROS and Na+ in PV cardiomyocytes, but did not change Na+‐Ca2+ exchange currents.Conclusion: C2 ceramide may exert the distinctive electrophysiological effect of modulating PV activities, which may be affected by PI3K pathway–mediated oxidative stress, and might play a role in the pathogenesis of PV arrhythmogenesis.
- Open Access
- 6 April 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (7) , 3839
Detecting Digoxin Toxicity by Artificial Intelligence-Assisted Electrocardiography
Although digoxin is important in heart rate control, the utilization of digoxin is declining due to its narrow therapeutic window. Misdiagnosis or delayed diagnosis of digoxin toxicity is common due to the lack of awareness and the time-consuming laboratory work that is involved. Electrocardiography (ECG) may be able to detect potential digoxin toxicity based on characteristic presentations. Our study attempted to develop a deep learning model to detect digoxin toxicity based on ECG manifestations. This study included 61 ECGs from patients with digoxin toxicity and 177,066 ECGs from patients in the emergency room from November 2011 to February 2019. The deep learning algorithm was trained using approximately 80% of ECGs. The other 20% of ECGs were used to validate the performance of the Artificial Intelligence (AI) system and to conduct a human-machine competition. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were used to evaluate the performance of ECG interpretation between humans and our deep learning system. The AUCs of our deep learning system for identifying digoxin toxicity were 0.912 and 0.929 in the validation cohort and the human-machine competition, respectively, which reached 84.6% of sensitivity and 94.6% of specificity. Interestingly, the deep learning system using only lead I (AUC = 0.960) was not worse than using complete 12 leads (0.912). Stratified analysis showed that our deep learning system was more applicable to patients with heart failure (HF) and without atrial fibrillation (AF) than those without HF and with AF. Our ECG-based deep learning system provides a high-accuracy, economical, rapid, and accessible way to detect digoxin toxicity, which can be applied as a promising decision supportive system for diagnosing digoxin toxicity in clinical practice.
- 6 April 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (7) , 3839
Open AccessDetecting Digoxin Toxicity by Artificial Intelligence-Assisted Electrocardiography
Although digoxin is important in heart rate control, the utilization of digoxin is declining due to its narrow therapeutic window. Misdiagnosis or delayed diagnosis of digoxin toxicity is common due to the lack of awareness and the time-consuming laboratory work that is involved. Electrocardiography (ECG) may be able to detect potential digoxin toxicity based on characteristic presentations. Our study attempted to develop a deep learning model to detect digoxin toxicity based on ECG manifestations. This study included 61 ECGs from patients with digoxin toxicity and 177,066 ECGs from patients in the emergency room from November 2011 to February 2019. The deep learning algorithm was trained using approximately 80% of ECGs. The other 20% of ECGs were used to validate the performance of the Artificial Intelligence (AI) system and to conduct a human-machine competition. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were used to evaluate the performance of ECG interpretation between humans and our deep learning system. The AUCs of our deep learning system for identifying digoxin toxicity were 0.912 and 0.929 in the validation cohort and the human-machine competition, respectively, which reached 84.6% of sensitivity and 94.6% of specificity. Interestingly, the deep learning system using only lead I (AUC = 0.960) was not worse than using complete 12 leads (0.912). Stratified analysis showed that our deep learning system was more applicable to patients with heart failure (HF) and without atrial fibrillation (AF) than those without HF and with AF. Our ECG-based deep learning system provides a high-accuracy, economical, rapid, and accessible way to detect digoxin toxicity, which can be applied as a promising decision supportive system for diagnosing digoxin toxicity in clinical practice.