Christopher Thomas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christopher Thomas has a total of 166 co-authors. Here are the top co-authors by number of shared publications:
- Teresa Guerrero Urbano
Guy’s and St Thomas’ NHS Foundation Trust
9 shared publications M. Lei
5 shared publicationsT. Guerrero Urbano
From the Departments of Oncology (D.A., I.P., M.R.F., A.K., M.L., T.G.U.)
5 shared publicationsL. Pike
King's College London and Guy's and St Thomas' PET Centre, School of Biomedical Engineering and Imaging Sciences, King's College London, King's Health Partners, London, UK
4 shared publicationsS. Barrington
King's College London and Guy's and St Thomas' PET Centre, School of Biomedical Engineering and Imaging Sciences, King's College London, King's Health Partners, London, UK
4 shared publications- Sally Fiona Barrington
King’s College London and Guy’s and St Thomas’ PET Centre, School of Biomedical Engineering and Imaging Sciences, King’s College London, King’s Health Partners, London, UK
4 shared publications
Latest Publications
- Open Access
- 31 October 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 202, 110609
Knowledge-based planning for fully automated radiation therapy treatment planning of 10 different cancer sites
- 31 October 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 202, 110609
Open AccessKnowledge-based planning for fully automated radiation therapy treatment planning of 10 different cancer sites
- Open Access
- 12 December 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 6 (1) , tzae014
Effect of synthetic CT on dose-derived toxicity predictors for MR-only prostate radiotherapy
Objectives: Toxicity-driven adaptive radiotherapy (RT) is enhanced by the superior soft tissue contrast of magnetic resonance (MR) imaging compared with conventional computed tomography (CT). However, in an MR-only RT pathway synthetic CTs (sCT) are required for dose calculation. This study evaluates 3 sCT approaches for accurate rectal toxicity prediction in prostate RT. Methods: Thirty-six patients had MR (T2-weighted acquisition optimized for anatomical delineation, and T1-Dixon) with same day standard-of-care planning CT for prostate RT. Multiple sCT were created per patient using bulk density (BD), tissue stratification (TS, from T1-Dixon) and deep-learning (DL) artificial intelligence (AI) (from T2-weighted) approaches for dose distribution calculation and creation of rectal dose volume histograms (DVH) and dose surface maps (DSM) to assess grade-2 (G2) rectal bleeding risk. Results: Maximum absolute errors using sCT for DVH-based G2 rectal bleeding risk (risk range 1.6% to 6.1%) were 0.6% (BD), 0.3% (TS) and 0.1% (DL). DSM-derived risk prediction errors followed a similar pattern. DL sCT has voxel-wise density generated from T2-weighted MR and improved accuracy for both risk-prediction methods. Conclusions: DL improves dosimetric and predicted risk calculation accuracy. Both TS and DL methods are clinically suitable for sCT generation in toxicity-guided RT, however, DL offers increased accuracy and offers efficiencies by removing the need for T1-Dixon MR. Advances in knowledge: This study demonstrates novel insights regarding the effect of sCT on predictive toxicity metrics, demonstrating clear accuracy improvement with increased sCT resolution. Accuracy of toxicity calculation in MR-only RT should be assessed for all treatment sites where dose to critical structures will guide adaptive-RT strategies. Clinical trial registration number: Patient data were taken from an ethically approved (UK Health Research Authority) clinical trial run at Guy’s and St Thomas’ NHS Foundation Trust. Study Name: MR-simulation in Radiotherapy for Prostate Cancer. ClinicalTrials.gov Identifier: NCT03238170.
- 12 December 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 6 (1) , tzae014
Open AccessEffect of synthetic CT on dose-derived toxicity predictors for MR-only prostate radiotherapy
Objectives: Toxicity-driven adaptive radiotherapy (RT) is enhanced by the superior soft tissue contrast of magnetic resonance (MR) imaging compared with conventional computed tomography (CT). However, in an MR-only RT pathway synthetic CTs (sCT) are required for dose calculation. This study evaluates 3 sCT approaches for accurate rectal toxicity prediction in prostate RT. Methods: Thirty-six patients had MR (T2-weighted acquisition optimized for anatomical delineation, and T1-Dixon) with same day standard-of-care planning CT for prostate RT. Multiple sCT were created per patient using bulk density (BD), tissue stratification (TS, from T1-Dixon) and deep-learning (DL) artificial intelligence (AI) (from T2-weighted) approaches for dose distribution calculation and creation of rectal dose volume histograms (DVH) and dose surface maps (DSM) to assess grade-2 (G2) rectal bleeding risk. Results: Maximum absolute errors using sCT for DVH-based G2 rectal bleeding risk (risk range 1.6% to 6.1%) were 0.6% (BD), 0.3% (TS) and 0.1% (DL). DSM-derived risk prediction errors followed a similar pattern. DL sCT has voxel-wise density generated from T2-weighted MR and improved accuracy for both risk-prediction methods. Conclusions: DL improves dosimetric and predicted risk calculation accuracy. Both TS and DL methods are clinically suitable for sCT generation in toxicity-guided RT, however, DL offers increased accuracy and offers efficiencies by removing the need for T1-Dixon MR. Advances in knowledge: This study demonstrates novel insights regarding the effect of sCT on predictive toxicity metrics, demonstrating clear accuracy improvement with increased sCT resolution. Accuracy of toxicity calculation in MR-only RT should be assessed for all treatment sites where dose to critical structures will guide adaptive-RT strategies. Clinical trial registration number: Patient data were taken from an ethically approved (UK Health Research Authority) clinical trial run at Guy’s and St Thomas’ NHS Foundation Trust. Study Name: MR-simulation in Radiotherapy for Prostate Cancer. ClinicalTrials.gov Identifier: NCT03238170.
- Open Access
- 26 January 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (2) , 192-198
The Impact of Interactive MRI-Based Radiologist Review on Radiotherapy Target Volume Delineation in Head and Neck Cancer
BACKGROUND AND PURPOSE: Peer review of head and neck cancer radiation therapy target volumes by radiologists was introduced in our center to optimize target volume delineation. Our aim was to assess the impact of MR imaging-based radiologist peer review of head and neck radiation therapy gross tumor and nodal volumes, through qualitative and quantitative analysis. MATERIALS AND METHODS: Cases undergoing radical radiation therapy with a coregistered MR imaging, between April 2019 and March 2020, were reviewed. The frequency and nature of volume changes were documented, with major changes classified as per the guidance of The Royal College of Radiologists. Volumetric alignment was assessed using the Dice similarity coefficient, Jaccard index, and Hausdorff distance. RESULTS: Fifty cases were reviewed between April 2019 and March 2020. The median age was 59 years (range, 29–83 years), and 72% were men. Seventy-six percent of gross tumor volumes and 41.5% of gross nodal volumes were altered, with 54.8% of gross tumor volume and 66.6% of gross nodal volume alterations classified as “major.” Undercontouring of soft-tissue involvement and unidentified lymph nodes were predominant reasons for change. Radiologist review significantly altered the size of both the gross tumor volume (P = .034) and clinical target tumor volume (P = .003), but not gross nodal volume or clinical target nodal volume. The median conformity and surface distance metrics were the following: gross tumor volume Dice similarity coefficient = 0.93 (range, 0.82–0.96), Jaccard index = 0.87 (range, 0.7–0.94), Hausdorff distance = 7.45 mm (range, 5.6–11.7 mm); and gross nodular tumor volume Dice similarity coefficient = 0.95 (0.91–0.97), Jaccard index = 0.91 (0.83–0.95), and Hausdorff distance = 20.7 mm (range, 12.6–41.6). Conformity improved on gross tumor volume-to-clinical target tumor volume expansion (Dice similarity coefficient = 0.93 versus 0.95, P = .003). CONCLUSIONS: MR imaging–based radiologist review resulted in major changes to most radiotherapy target volumes and significant changes in volume size of both gross tumor volume and clinical target tumor volume, suggesting that this is a fundamental step in the radiotherapy workflow of patients with head and neck cancer.
- 26 January 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (2) , 192-198
Open AccessThe Impact of Interactive MRI-Based Radiologist Review on Radiotherapy Target Volume Delineation in Head and Neck Cancer
BACKGROUND AND PURPOSE: Peer review of head and neck cancer radiation therapy target volumes by radiologists was introduced in our center to optimize target volume delineation. Our aim was to assess the impact of MR imaging-based radiologist peer review of head and neck radiation therapy gross tumor and nodal volumes, through qualitative and quantitative analysis. MATERIALS AND METHODS: Cases undergoing radical radiation therapy with a coregistered MR imaging, between April 2019 and March 2020, were reviewed. The frequency and nature of volume changes were documented, with major changes classified as per the guidance of The Royal College of Radiologists. Volumetric alignment was assessed using the Dice similarity coefficient, Jaccard index, and Hausdorff distance. RESULTS: Fifty cases were reviewed between April 2019 and March 2020. The median age was 59 years (range, 29–83 years), and 72% were men. Seventy-six percent of gross tumor volumes and 41.5% of gross nodal volumes were altered, with 54.8% of gross tumor volume and 66.6% of gross nodal volume alterations classified as “major.” Undercontouring of soft-tissue involvement and unidentified lymph nodes were predominant reasons for change. Radiologist review significantly altered the size of both the gross tumor volume (P = .034) and clinical target tumor volume (P = .003), but not gross nodal volume or clinical target nodal volume. The median conformity and surface distance metrics were the following: gross tumor volume Dice similarity coefficient = 0.93 (range, 0.82–0.96), Jaccard index = 0.87 (range, 0.7–0.94), Hausdorff distance = 7.45 mm (range, 5.6–11.7 mm); and gross nodular tumor volume Dice similarity coefficient = 0.95 (0.91–0.97), Jaccard index = 0.91 (0.83–0.95), and Hausdorff distance = 20.7 mm (range, 12.6–41.6). Conformity improved on gross tumor volume-to-clinical target tumor volume expansion (Dice similarity coefficient = 0.93 versus 0.95, P = .003). CONCLUSIONS: MR imaging–based radiologist review resulted in major changes to most radiotherapy target volumes and significant changes in volume size of both gross tumor volume and clinical target tumor volume, suggesting that this is a fundamental step in the radiotherapy workflow of patients with head and neck cancer.
- Open Access
- 11 March 2022
- Published by Wiley in Medical Physics
- Vol. 49 (4) , 2172-2182
Neural network dose prediction for rectal spacer stratification in dose‐escalated prostate radiotherapy
Purpose To develop a knowledge-based decision-support system capable of stratifying patients for rectal spacer (RS) insertion based on neural network predicted rectal dose, reducing the need for time- and resource-intensive radiotherapy (RT) planning. Methods Forty-four patients treated for prostate cancer were enrolled into a clinical trial (NCT03238170). Dose-escalated prostate RT plans were manually created for 30 patients with simulated boost volumes using a conventional treatment planning system (TPS) and used to train a hierarchically dense 3D convolutional neural network to rapidly predict RT dose distributions. The network was used to predict rectal doses for 14 unseen test patients, with associated toxicity risks calculated according to published data. All metrics obtained using the network were compared to conventionally planned values. Results The neural network stratified patients with an accuracy of 100% based on optimal rectal dose-volume histogram constraints and 78.6% based on mandatory constraints. The network predicted dose-derived grade 2 rectal bleeding risk within 95% confidence limits of -1.9% to +1.7% of conventional risk estimates (risk range 3.5%-9.9%) and late grade 2 fecal incontinence risk within -0.8% to +1.5% (risk range 2.3%-5.7%). Prediction of high-resolution 3D dose distributions took 0.7 s. Conclusions The feasibility of using a neural network to provide rapid decision support for RS insertion prior to RT has been demonstrated, and the potential for time and resource savings highlighted. Directly after target and healthy tissue delineation, the network is able to (i) risk stratify most patients with a high degree of accuracy to prioritize which patients would likely derive greatest benefit from RS insertion and (ii) identify patients close to the stratification threshold who would require conventional planning.
- 11 March 2022
- Published by Wiley in Medical Physics
- Vol. 49 (4) , 2172-2182
Open AccessNeural network dose prediction for rectal spacer stratification in dose‐escalated prostate radiotherapy
Purpose To develop a knowledge-based decision-support system capable of stratifying patients for rectal spacer (RS) insertion based on neural network predicted rectal dose, reducing the need for time- and resource-intensive radiotherapy (RT) planning. Methods Forty-four patients treated for prostate cancer were enrolled into a clinical trial (NCT03238170). Dose-escalated prostate RT plans were manually created for 30 patients with simulated boost volumes using a conventional treatment planning system (TPS) and used to train a hierarchically dense 3D convolutional neural network to rapidly predict RT dose distributions. The network was used to predict rectal doses for 14 unseen test patients, with associated toxicity risks calculated according to published data. All metrics obtained using the network were compared to conventionally planned values. Results The neural network stratified patients with an accuracy of 100% based on optimal rectal dose-volume histogram constraints and 78.6% based on mandatory constraints. The network predicted dose-derived grade 2 rectal bleeding risk within 95% confidence limits of -1.9% to +1.7% of conventional risk estimates (risk range 3.5%-9.9%) and late grade 2 fecal incontinence risk within -0.8% to +1.5% (risk range 2.3%-5.7%). Prediction of high-resolution 3D dose distributions took 0.7 s. Conclusions The feasibility of using a neural network to provide rapid decision support for RS insertion prior to RT has been demonstrated, and the potential for time and resource savings highlighted. Directly after target and healthy tissue delineation, the network is able to (i) risk stratify most patients with a high degree of accuracy to prioritize which patients would likely derive greatest benefit from RS insertion and (ii) identify patients close to the stratification threshold who would require conventional planning.
- 1 February 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 155, 261-268
18F-FDG-PET in guided dose-painting with intensity modulated radiotherapy in oropharyngeal tumours: A phase I study (FiGaRO)
- 1 February 2021
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 155, 261-268
18F-FDG-PET in guided dose-painting with intensity modulated radiotherapy in oropharyngeal tumours: A phase I study (FiGaRO)
- 5 December 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1105) , 20190161
Guidance on the use of MRI for treatment planning in radiotherapy clinical trials
The aim of this article is to propose meaningful guidance covering the technical and safety issues involved when designing or conducting radiotherapy clinical trials that use MRI for treatment planning. The complexity of imaging requirements will depend on the trial aims, design and MRI methods used. The use of MRI within the RT pathway is becoming more prevalent and clinically appropriate as access to MRI increases, treatment planning systems become more versatile and potential indications for MRI-planning in RT are documented. Novel MRI-planning opportunities are often initiated and validated within clinical trials. The guidance in this document is intended to assist researchers designing RT clinical trials involving MRI, so that they may provide sufficient information about the appropriate methods to be used for image acquisition, post-processing and quality assurance such that participating sites complete MRI to consistent standards. It has been produced in collaboration with the National Radiotherapy Trials Quality Assurance Group (RTTQA). As the use of MRI in RT is developed, it is highly recommended for researchers writing clinical trial protocols to include imaging guidance as part of their clinical trial documentation covering the trial-specific requirements for MRI procedures. Many of the considerations and recommendations in this guidance may well apply to MR-guided treatment machines, where clinical trials will be crucial. Similarly, many of these recommendations will apply to the general use of MRI in RT, outside of clinical trials. This document contains a large number of recommendations, not all of which will be relevant to any particular trial. Designers of RT clinical trials must therefore take this into account. They must also use their own judgement as to the appropriate compromise between accessibility of the trial and its technical rigour.
- 5 December 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1105) , 20190161
Guidance on the use of MRI for treatment planning in radiotherapy clinical trials
The aim of this article is to propose meaningful guidance covering the technical and safety issues involved when designing or conducting radiotherapy clinical trials that use MRI for treatment planning. The complexity of imaging requirements will depend on the trial aims, design and MRI methods used. The use of MRI within the RT pathway is becoming more prevalent and clinically appropriate as access to MRI increases, treatment planning systems become more versatile and potential indications for MRI-planning in RT are documented. Novel MRI-planning opportunities are often initiated and validated within clinical trials. The guidance in this document is intended to assist researchers designing RT clinical trials involving MRI, so that they may provide sufficient information about the appropriate methods to be used for image acquisition, post-processing and quality assurance such that participating sites complete MRI to consistent standards. It has been produced in collaboration with the National Radiotherapy Trials Quality Assurance Group (RTTQA). As the use of MRI in RT is developed, it is highly recommended for researchers writing clinical trial protocols to include imaging guidance as part of their clinical trial documentation covering the trial-specific requirements for MRI procedures. Many of the considerations and recommendations in this guidance may well apply to MR-guided treatment machines, where clinical trials will be crucial. Similarly, many of these recommendations will apply to the general use of MRI in RT, outside of clinical trials. This document contains a large number of recommendations, not all of which will be relevant to any particular trial. Designers of RT clinical trials must therefore take this into account. They must also use their own judgement as to the appropriate compromise between accessibility of the trial and its technical rigour.
- 1 September 2019
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 77 (9) , e32-e33
A Digitally Generated 3D Dental Model for Assessment of Radiotherapy Doses to the Dentition in Oropharyngeal Cancer Patients for Pre-IMRT Dental Treatment Planning
- 1 September 2019
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 77 (9) , e32-e33
A Digitally Generated 3D Dental Model for Assessment of Radiotherapy Doses to the Dentition in Oropharyngeal Cancer Patients for Pre-IMRT Dental Treatment Planning
- 23 August 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1103) , 20190180
Guidance on the use of PET for treatment planning in radiotherapy clinical trials
The aim of this article is to propose meaningful guidance covering the practical and technical issues involved when planning or conducting clinical trials involving positron emission tomography (PET)-guided radiotherapy. The complexity of imaging requirements will depend on the study aims, design and PET methods used. Where PET is used to adapt radiotherapy, a high level of accuracy and reproducibility is required to ensure effective and safe treatment delivery. The guidance in this document is intended to assist researchers designing clinical trials involving PET-guided radiotherapy to provide sufficient information about the appropriate methods to complete PET-CT imaging to a consistent standard at participating centres. The guidance is divided into six categories: application of PET in radiotherapy, resource requirements, quality assurance, imaging protocol design, data management and image processing. Each section provides an overview of the recent literature to support the specific recommendations. This guidance builds on previous recommendations from the National Cancer Research Institute PET Research Network and has been produced in collaboration with the National Radiotherapy Trials Quality Assurance Group.
- 23 August 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 92 (1103) , 20190180
Guidance on the use of PET for treatment planning in radiotherapy clinical trials
The aim of this article is to propose meaningful guidance covering the practical and technical issues involved when planning or conducting clinical trials involving positron emission tomography (PET)-guided radiotherapy. The complexity of imaging requirements will depend on the study aims, design and PET methods used. Where PET is used to adapt radiotherapy, a high level of accuracy and reproducibility is required to ensure effective and safe treatment delivery. The guidance in this document is intended to assist researchers designing clinical trials involving PET-guided radiotherapy to provide sufficient information about the appropriate methods to complete PET-CT imaging to a consistent standard at participating centres. The guidance is divided into six categories: application of PET in radiotherapy, resource requirements, quality assurance, imaging protocol design, data management and image processing. Each section provides an overview of the recent literature to support the specific recommendations. This guidance builds on previous recommendations from the National Cancer Research Institute PET Research Network and has been produced in collaboration with the National Radiotherapy Trials Quality Assurance Group.
- Open Access
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S645
EP-1149: Clinical Evaluation of attenuation correction in FDG-PET/MRI in a head and neck radiotherapy setup
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S645
Open AccessEP-1149: Clinical Evaluation of attenuation correction in FDG-PET/MRI in a head and neck radiotherapy setup
- Open Access
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S361
PO-0706: Sensorineural hearing loss and radiotherapy for head and neck cancer
- 1 April 2018
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 127, S361
Open AccessPO-0706: Sensorineural hearing loss and radiotherapy for head and neck cancer