SASalil Apte

Salil Apte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Salil Apte has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Kamiar Aminian

    Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland

    6 shared publications
  • Vincent Gremeaux

    Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland

    5 shared publications
  • Cyril Besson

    Sport Medicine Unit, Division of Physical Medicine and Rehabilitation, Swiss Olympic Medical Center, Lausanne University Hospital

    2 shared publications
  • Heike Vallery

    Institute of Automatic Control, RWTH Aachen University, Aachen, Germany

    2 shared publications
  • Michiel Plooij

    Department of Biomechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD Delft, Netherlands

    2 shared publications
  • Aaron Martínez

    Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland

    1 shared publication

Latest Publications

  • Open Access

    Estimation of horizontal running power using foot-worn inertial measurement units

    by Salil Apte, Mathieu Falbriard, Frédéric Meyer, Grégoire P. Millet, Vincent Gremeaux, Kamiar Aminian

    Feedback of power during running is a promising tool for training and determining pacing strategies. However, current power estimation methods show low validity and are not customized for running on different slopes. To address this issue, we developed three machine-learning models to estimate peak horizontal power for level, uphill, and downhill running using gait spatiotemporal parameters, accelerometer, and gyroscope signals extracted from foot-worn IMUs. The prediction was compared to reference horizontal power obtained during running on a treadmill with an embedded force plate. For each model, we trained an elastic net and a neural network and validated it with a dataset of 34 active adults across a range of speeds and slopes. For the uphill and level running, the concentric phase of the gait cycle was considered, and the neural network model led to the lowest error (median ± interquartile range) of 1.7% ± 12.5% and 3.2% ± 13.4%, respectively. The eccentric phase was considered relevant for downhill running, wherein the elastic net model provided the lowest error of 1.8% ± 14.1%. Results showed a similar performance across a range of different speed/slope running conditions. The findings highlighted the potential of using interpretable biomechanical features in machine learning models for the estimating horizontal power. The simplicity of the models makes them suitable for implementation on embedded systems with limited processing and energy storage capacity. The proposed method meets the requirements for applications needing accurate near real-time feedback and complements existing gait analysis algorithms based on foot-worn IMUs.


  • Open Access

    In-field assessment of change-of-direction ability with a single wearable sensor

    by Salil Apte, Hojjat Karami, Célestin Vallat, Vincent Gremeaux, Kamiar Aminian

    The Agility T-test is a standardized method to measure the change-of-direction (COD) ability of athletes in the field. It is traditionally scored based on the total completion time, which does not provide information on the different CODs. Augmenting the T-test with wearable sensors provides the opportunity to explore new metrics. Towards this, data of 23 professional soccer players were recorded with a trunk-worn GNSS-IMU (Global Navigation Satellite System-Inertial Measurement Unit) device. A method for detecting the four CODs based on the wavelet-denoised antero-posterior acceleration signal was developed and validated using video data (60 Hz). Following this, completion time was estimated using GNSS ground speed and validated with the photocell data. The proposed method yields an error (mean ± standard deviation) of 0 ± 66 ms for the COD detection, − 0.16 ± 0.22 s for completion time, and a relative error for each COD duration and each sequential movement durations of less than 3.5 ± 16% and 7 ± 7%, respectively. The presented algorithm can highlight the asymmetric performance between the phases and CODs in the right and left direction. By providing a more comprehensive analysis in the field, this work can enable coaches to develop more personalized training and rehabilitation programs.


  • Open Access

    Augmented Cooper test: Biomechanical contributions to endurance performance

    by Salil Apte, Simone Troxler, Cyril Besson, Vincent Gremeaux, Kamiar Aminian

    Running mechanics are modifiable with training and adopting an economical running technique can improve running economy and hence performance. While field measurement of running economy is cumbersome, running mechanics can be assessed accurately and conveniently using wearable inertial measurement units (IMUs). In this work, we extended this wearables-based approach to the Cooper test, by assessing the relative contribution of running biomechanics to the endurance performance. Furthermore, we explored different methods of estimating the distance covered in the Cooper test using a wearable global navigation satellite system (GNSS) receiver. Thirty-three runners (18 highly trained and 15 recreational) performed an incremental laboratory treadmill test to measure their maximum aerobic speed (MAS) and speed at the second ventilatory threshold (sVT2). They completed a 12-minute Cooper running test with foot-worm IMUs and a chest-worn GNSS-IMU on a running track 1–2 weeks later. Using the GNSS receiver, an accurate estimation of the 12-minute distance was obtained (accuracy of 16.5 m and precision of 1.1%). Using this distance, we showed a reliable estimation [R2 > 0.9, RMSE ϵ (0.07, 0.25) km/h] of the MAS and sVT2. Biomechanical metrics were extracted using validated algorithm and their association with endurance performance was estimated. Additionally, the high-/low-performance runners were compared using pairwise statistical testing. All performance variables, MAS, sVT2, and average speed during Cooper test, were predicted with an acceptable error (R2 ≥ 0.65, RMSE ≤ 1.80 kmh−1) using only the biomechanical metrics. The most relevant metrics were used to develop a biomechanical profile representing the running technique and its temporal evolution with acute fatigue, identifying different profiles for runners with highest and lowest endurance performance. This profile could potentially be used in standardized functional capacity measurements to improve personalization of training and rehabilitation programs.


  • Open Access

    Concurrent Evolution of Biomechanical and Physiological Parameters With Running-Induced Acute Fatigue

    by Gäelle Prigent, Salil Apte, Anisoara Paraschiv-Ionescu, Cyril Besson, Vincent Gremeaux, Kamiar Aminian

    Understanding the influence of running-induced acute fatigue on the homeostasis of the body is essential to mitigate the adverse effects and optimize positive adaptations to training. Fatigue is a multifactorial phenomenon, which influences biomechanical, physiological, and psychological facets. This work aimed to assess the evolution of these three facets with acute fatigue during a half-marathon. 13 recreational runners were equipped with one inertial measurement unit (IMU) on each foot, one combined global navigation satellite system-IMU-electrocardiogram sensor on the chest, and an Android smartphone equipped with an audio recording application. Spatio-temporal parameters for the running gait, along with the heart rate, its variability and complexity were computed using validated algorithms. Perceived fatigability was assessed using the rating-of-fatigue (ROF) scale at every 10 min of the race. The data was split into eight equal segments, corresponding to at least one ROF value per segment, and only level running parts were retained for analysis. During the race, contact time, duty factor, and trunk anteroposterior acceleration increased, and the foot strike angle and vertical stiffness decreased significantly. Heart rate showed a progressive increase, while the metrics for heart rate variability and complexity decreased during the race. The biomechanical parameters showed a significant alteration even with a small change in perceived fatigue, whereas the heart rate dynamics altered at higher changes. When divided into two groups, the slower runners presented a higher change in heart rate dynamics throughout the race than the faster runners; they both showed similar trends for the gait parameters. When tested for linear and non-linear correlations, heart rate had the highest association with biomechanical parameters, while the trunk anteroposterior acceleration had the lowest association with heart rate dynamics. These results indicate the ability of faster runners to better judge their physiological limits and hint toward a higher sensitivity of perceived fatigue to neuromuscular changes in the running gait. This study highlights measurable influences of acute fatigue, which can be studied only through concurrent measurement of biomechanical, physiological, and psychological facets of running in real-world conditions.


  • Neglected physical human-robot interaction may explain variable outcomes in gait neurorehabilitation research

    by M. Plooij, S. Apte, U. Keller, P. Baines, B. Sterke, L. Asboth, G. Courtine, J. von Zitzewitz, H. Vallery

    Device transparency, support force, and attachment are important for optimal body-weight support in gait neurorehabilitation.


  • Open Access

    Biomechanical Response of the Lower Extremity to Running-Induced Acute Fatigue: A Systematic Review

    by Salil Apte, Gäelle Prigent, Thomas Stöggl, Aaron Martínez, Cory Snyder, Vincent Gremeaux-Bader, Kamiar Aminian

    Objective: To investigate (i) typical protocols used in research on biomechanical response to running-induced fatigue, (ii) the effect of sport-induced acute fatigue on the biomechanics of running and functional tests, and (iii) the consistency of analyzed parameter trends across different protocols.Methods: Scopus, Web of Science, Pubmed, and IEEE databases were searched using terms identified with the Population, Interest and Context (PiCo) framework. Studies were screened following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and appraised using the methodological index for non-randomized studies MINORS scale. Only experimental studies with at least 10 participants, which evaluated fatigue during and immediately after the fatiguing run were included. Each study was summarized to record information about the protocol and parameter trends. Summary trends were computed for each parameter based on the results found in individual studies.Results: Of the 68 included studies, most were based on in-lab (77.9%) protocols, endpoint measurements (75%), stationary measurement systems (76.5%), and treadmill environment (54.4%) for running. From the 42 parameters identified in response to acute fatigue, flight time, contact time, knee flexion angle at initial contact, trunk flexion angle, peak tibial acceleration, CoP velocity during balance test showed an increasing behavior and cadence, vertical stiffness, knee extension force during MVC, maximum vertical ground reaction forces, and CMJ height showed a decreasing trend across different fatigue protocols.Conclusion: This review presents evidence that running-induced acute fatigue influences almost all the included biomechanical parameters, with crucial influence from the exercise intensity and the testing environment. Results indicate an important gap in literature caused by the lack of field studies with continuous measurement during outdoor running activities. To address this gap, we propose recommendations for the use of wearable inertial sensors.


  • Open Access

    A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint

    by Salil Apte, Frederic Meyer, Vincent Gremeaux, Farzin Dadashi, Kamiar Aminian

    Power-Force-Velocity profile obtained during a sprint test is crucial for designing personalized training and evaluating injury risks. Estimation of instantaneous velocity is requisite for developing these profiles and the predominant method for this estimation assumes it to have a first order exponential behavior. While this method remains appropriate for maximal sprints, the sprint velocity profile may not always show a first-order exponential behavior. Alternately, velocity profile has been estimated using inertial sensors, with a speed radar, or a smartphone application. Existing methods either relied on the exponential behavior or timing gates for drift removal, or estimated only the mean velocity. Thus, there is a need for a more flexible and appropriate approach, allowing for instantaneous velocity estimation during sprint tests. The proposed method aims to solve this problem using a sensor fusion approach, by combining the signals from wearable Global Navigation Satellite System (GNSS) and inertial measurement unit (IMU) sensors. We collected data from nine elite sprinters, equipped with a wearable GNSS-IMU sensor, who ran two trials each of 60 and 30/40 m sprints. We developed an algorithm using a gradient descent-based orientation filter, which simplified our model to a linear one-dimensional model, thus allowing us to use a simple Kalman filter (KF) for velocity estimation. We used two cascaded KFs, to segment the sprint data precisely, and to estimate the velocity and the sprint duration, respectively. We validated the estimated velocity and duration with speed radar and photocell data as reference. The median RMS error for the estimated velocity ranged from 6 to 8%, while that for the estimated sprint duration lied between 0.1 and −6.0%. The Bland–Altman plot showed close agreement between the estimated and the reference values of maximum velocity. Examination of fitting errors indicated a second order exponential behavior for the sprint velocity profile, unlike the first order behavior previously suggested in literature. The proposed sensor-fusion algorithm is valid to compute an accurate velocity profile with respect to the radar; it can compensate for and improve upon the accuracy of the individual IMU and GNSS velocities. This method thus enables the use of wearable sensors in the analysis of sprint test.


  • Open Access

    Simulation of human gait with body weight support: benchmarking models and unloading strategies

    by Salil Apte, Michiel Plooij, Heike Vallery

    Background: Gait training with partial body weight support (BWS) has become an established rehabilitation technique. Besides passive unloading mechanisms such as springs or counterweights, also active systems that allow rendering constant or modulated vertical forces have been proposed. However, only pilot studies have been conducted to compare different unloading or modulation strategies, and conducting experimental studies is costly and time-consuming. Simulation models that predict the influence of unloading force on human walking may help select the most promising candidates for further evaluation. However, the reliability of simulation results depends on the chosen gait model. The purpose of this paper is two-fold: First, using human experimental data, we evaluate the accuracy of some of the most prevalent walking models in replicating human walking under the influence of Constant-Force BWS: The Simplest Walking model (SW), the Spring-Loaded Inverted Pendulum model (SLIP) and the Muscle-Reflex (MR) gait model. Second, three realizations of BWS, based on Constant-Force (CF), Counterweight (CW) and Tuned-Spring (TS) approaches, are compared to each other in terms of their influence on gait parameters. Methods: We conducted simulations in Matlab/Simulink to model the behaviour of each gait model under all three BWS conditions. Nine simulations were undertaken in total and gait parameter response was analysed in each case. Root mean square error (mrmse) w.r.t human data was used to compare the accuracy of gait models. The metrics of interest were spatiotemporal parameters and the vertical ground reaction forces. To scrutinize the BWS strategies, loss of dynamic similarity was calculated in terms of root mean square difference in gait dynamics (Δgd) with respect to the reference gait under zero unloading. The gait dynamics were characterized by a dimensionless number Modela-w. Results: SLIP model showed the lowest mrmse for 6 out of 8 gait parameters and for 1 other, the mrmse value were comparable to the MR model; SW model had the highest mrmse. Out of three BWS strategies, Tuned-Spring strategies led to the lowest Δgd values. Conclusions: The results of this work demonstrate the usefulness of gait models for BWS simulation and suggest the SLIP model to be more suitable for BWS simulations than the Simplest Walker and the Muscle-reflex models. Further, the Tuned-Spring approach appears to cause less distortions to the gait pattern than the more established Counterweight and Constant-Force approaches and merits experimental verification.


  • Variable Stiffness Spring Actuators for Low-Energy-Cost Human Augmentation

    by David J. Braun, Vincent Chalvet, Tze-Hao Chong, Salil S. Apte, Neville Hogan

    Theoretical studies suggest and experimental evidence confirms that maintaining and changing human joint stiffness by coactivated antagonistic muscles are metabolically expensive, even if muscles do not perform net mechanical work. Based on this observation, we posit that effective human augmentation can be achieved by actuators operated in parallel to human joints, even if these actuators only supplement joint stiffness without doing net mechanical work. In this article, we present a prototype variable-length leaf-spring actuator capable of large-range stiffness modulation. The key feature of the actuator is that it provides intrinsically low-energy-cost stiffness modulation even for large output deflection, by keeping the force on the driving motor low. Variable stiffness actuators use two motors to provide both stiffness and equilibrium position modulation as they are designed to do net mechanical work. The proposed actuator conceptually differs from variable stiffness actuators because first, it uses a single motor to only provide stiffness modulation, second, it does not provide equilibrium position modulation, and third, unless externally loaded, it cannot do net mechanical work. Using this actuator, we demonstrate stiffness augmentation during human–machine collaboration in challenging postural stabilization and weight-bearing tasks. Our results indicate that the proposed actuator can be used to complement a biological system by restoring or extending its functionality with low energy cost, and that variable stiffness spring actuators could effectively augment humans by doing no or a limited amount of mechanical work.