Yuxin Xing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuxin Xing has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Julian William Gardner
Microsensors and Bioelectronics Laboratory, School of Engineering, University of Warwick, Coventry CV4 7AL, UK
5 shared publications - Timothy A. Vincent
School of Engineering, University of Warwick, Coventry CV4 7AL, UK
4 shared publications - Marina Cole
Microsensors and Bioelectronics Laboratory, School of Engineering, University of Warwick, Coventry CV4 7AL, UK
3 shared publications - Sailing He
Zhejiang University
3 shared publications A. Gabriel
University of California, San Francisco, Department of Anesthesia, Box 0464, Room S-455, 513 Parnassus Avenue, San Francisco, CA 94143, USA, Fax: ++ 415 502 5375,
1 shared publication- Achim J. Lilienthal
Örebro University
1 shared publication
Latest Publications
- 13 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (11) , 111105
Wavelength-modulated photoacoustic spectroscopy sensor for multi-gas measurement of acetone, methane, and water vapor based on a differential acoustic resonator
Precise assessment of breath acetone and methane is significant to the medical diagnosis process. A multi-gas sensing system based on wavelength-modulated differential photoacoustic spectroscopy was developed for simultaneous measurement of acetone and methane. A distributed feedback diode laser emitting in the range from 3363 to 3371 nm was employed to scan the absorption lines of acetone and methane. The cross sensitivities in terms of spectral interference among acetone, methane, and water vapor are effectively eliminated by using a linear combination method of reference spectra for accurately determining the concentration of acetone and methane. The positive effect of water vapor on photoacoustic signal resulting from the light absorption of acetone and methane was precisely evaluated. To improve the instrument performance, a differential PA cell companying with a differential amplifier circuit is experimentally demonstrated in providing a better performance of noise suppression compared with a single acoustic resonator. With a low detection limit down to 0.43 ppm and 12 ppb (integration time of 10 s) for acetone and methane, the sensor shows a great potential for medical diagnosis in simultaneous measurement of acetone and methane.
- 13 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (11) , 111105
Wavelength-modulated photoacoustic spectroscopy sensor for multi-gas measurement of acetone, methane, and water vapor based on a differential acoustic resonator
Precise assessment of breath acetone and methane is significant to the medical diagnosis process. A multi-gas sensing system based on wavelength-modulated differential photoacoustic spectroscopy was developed for simultaneous measurement of acetone and methane. A distributed feedback diode laser emitting in the range from 3363 to 3371 nm was employed to scan the absorption lines of acetone and methane. The cross sensitivities in terms of spectral interference among acetone, methane, and water vapor are effectively eliminated by using a linear combination method of reference spectra for accurately determining the concentration of acetone and methane. The positive effect of water vapor on photoacoustic signal resulting from the light absorption of acetone and methane was precisely evaluated. To improve the instrument performance, a differential PA cell companying with a differential amplifier circuit is experimentally demonstrated in providing a better performance of noise suppression compared with a single acoustic resonator. With a low detection limit down to 0.43 ppm and 12 ppb (integration time of 10 s) for acetone and methane, the sensor shows a great potential for medical diagnosis in simultaneous measurement of acetone and methane.
- 24 June 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (14) , 24804-24821
4D dual-mode staring hyperspectral-depth imager for simultaneous spectral sensing and surface shape measurement
A 4D dual-mode staring hyperspectral-depth imager (DSHI), which acquire reflectance spectra, fluorescence spectra, and 3D structural information by combining a staring hyperspectral scanner and a binocular line laser stereo vision system, is introduced. A 405 nm laser line generated by a focal laser line generation module is used for both fluorescence excitation and binocular stereo matching of the irradiated line region. Under the configuration, the two kinds of hyperspectral data collected by the hyperspectral scanner can be merged into the corresponding points in the 3D model, forming a dual-mode 4D model. The DSHI shows excellent performance with spectral resolution of 3 nm, depth accuracy of 26.2 µm. Sample experiments on a fluorescent figurine, real and plastic sunflowers and a clam are presented to demonstrate system’s with potential within a broad range of applications such as, e.g., digital documentation, plant phenotyping, and biological analysis.
- 24 June 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (14) , 24804-24821
4D dual-mode staring hyperspectral-depth imager for simultaneous spectral sensing and surface shape measurement
A 4D dual-mode staring hyperspectral-depth imager (DSHI), which acquire reflectance spectra, fluorescence spectra, and 3D structural information by combining a staring hyperspectral scanner and a binocular line laser stereo vision system, is introduced. A 405 nm laser line generated by a focal laser line generation module is used for both fluorescence excitation and binocular stereo matching of the irradiated line region. Under the configuration, the two kinds of hyperspectral data collected by the hyperspectral scanner can be merged into the corresponding points in the 3D model, forming a dual-mode 4D model. The DSHI shows excellent performance with spectral resolution of 3 nm, depth accuracy of 26.2 µm. Sample experiments on a fluorescent figurine, real and plastic sunflowers and a clam are presented to demonstrate system’s with potential within a broad range of applications such as, e.g., digital documentation, plant phenotyping, and biological analysis.
- Open Access
- 23 April 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (9) , 1440
Strong Coupling between a Single Quantum Emitter and a Plasmonic Nanoantenna on a Metallic Film
The strong coupling between single quantum emitters and resonant optical micro/nanocavities is beneficial for understanding light and matter interactions. Here, we propose a plasmonic nanoantenna placed on a metal film to achieve an ultra-high electric field enhancement in the nanogap and an ultra-small optical mode volume. The strong coupling between a single quantum dot (QD) and the designed structure is investigated in detail by both numerical simulations and theoretical calculations. When a single QD is inserted into the nanogap of the silver nanoantenna, the scattering spectra show a remarkably large splitting and anticrossing behavior of the vacuum Rabi splitting, which can be achieved in the scattering spectra by optimizing the nanoantenna thickness. Our work shows another way to enhance the light/matter interaction at a single quantum emitter limit, which can be useful for many nanophotonic and quantum applications.
- 23 April 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (9) , 1440
Open AccessStrong Coupling between a Single Quantum Emitter and a Plasmonic Nanoantenna on a Metallic Film
The strong coupling between single quantum emitters and resonant optical micro/nanocavities is beneficial for understanding light and matter interactions. Here, we propose a plasmonic nanoantenna placed on a metal film to achieve an ultra-high electric field enhancement in the nanogap and an ultra-small optical mode volume. The strong coupling between a single quantum dot (QD) and the designed structure is investigated in detail by both numerical simulations and theoretical calculations. When a single QD is inserted into the nanogap of the silver nanoantenna, the scattering spectra show a remarkably large splitting and anticrossing behavior of the vacuum Rabi splitting, which can be achieved in the scattering spectra by optimizing the nanoantenna thickness. Our work shows another way to enhance the light/matter interaction at a single quantum emitter limit, which can be useful for many nanophotonic and quantum applications.
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
Thermally Modulated CMOS-Compatible Particle Sensor for Air Quality Monitoring
Combating the health effects of particulate matter (PM) pollution requires affordable and reliable real-time air quality monitoring. The potential for large-scale manufacturing of acoustic-wave-based sensors makes them an interesting option for low-cost, low-power particle sensing applications. This article demonstrates a solidly mounted resonator (SMR) PM sensor with improved sensitivity through thermal modulation of the device. A novel, complementary metal oxide semiconductor (CMOS)-compatible SMR with an integrated microheater was designed, manufactured, and tested. In simulations, it was found that particle deposition increases both the heat loss and the thermal time constant of SMR. The effect of this on the resonant frequency shift of the device caused by particle deposition is investigated closely in this work. The sensitivity of the devices to particle deposition was tested experimentally with and without temperature modulation by placing the device in a test chamber and allowing the randomized settling of aerosolized particles on its surface. The unmodulated sensor demonstrated a particle mass sensitivity of ~40 Hz/ng while the mass sensitivity of the temperature-modulated device was shown to improve by a factor of nearly $\times 5$ to 190 Hz/ng. Temperature modulation also improved the detection limit from 100 to 50 ng. Further experiments were conducted by adding an impactor mechanism to have a more controlled measurement setup. To this effect, a thermophoretic particle deposition mechanism was added to the device to enhance its performance. It was demonstrated that the repeatability of measurements was significantly improved, making the device a promising low-cost technology for air quality monitoring.
- 7 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-13
Thermally Modulated CMOS-Compatible Particle Sensor for Air Quality Monitoring
Combating the health effects of particulate matter (PM) pollution requires affordable and reliable real-time air quality monitoring. The potential for large-scale manufacturing of acoustic-wave-based sensors makes them an interesting option for low-cost, low-power particle sensing applications. This article demonstrates a solidly mounted resonator (SMR) PM sensor with improved sensitivity through thermal modulation of the device. A novel, complementary metal oxide semiconductor (CMOS)-compatible SMR with an integrated microheater was designed, manufactured, and tested. In simulations, it was found that particle deposition increases both the heat loss and the thermal time constant of SMR. The effect of this on the resonant frequency shift of the device caused by particle deposition is investigated closely in this work. The sensitivity of the devices to particle deposition was tested experimentally with and without temperature modulation by placing the device in a test chamber and allowing the randomized settling of aerosolized particles on its surface. The unmodulated sensor demonstrated a particle mass sensitivity of ~40 Hz/ng while the mass sensitivity of the temperature-modulated device was shown to improve by a factor of nearly $\times 5$ to 190 Hz/ng. Temperature modulation also improved the detection limit from 100 to 50 ng. Further experiments were conducted by adding an impactor mechanism to have a more controlled measurement setup. To this effect, a thermophoretic particle deposition mechanism was added to the device to enhance its performance. It was demonstrated that the repeatability of measurements was significantly improved, making the device a promising low-cost technology for air quality monitoring.
- 2 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (24) , 12418-12431
FireNose on Mobile Robot in Harsh Environments
In this work we present a novel multi-sensor unit, a.k.a. FireNose, to detect and discriminate both known and unknown gases in uncontrolled conditions to aid firefighters under harsh conditions. The unit includes three metal oxide (MOX) gas sensors with CMOS micro heaters, a plasmonic enhanced non-dispersive infrared (NDIR) sensor optimized for the detection of CO2, a commercial temperature humidity sensor, and a flow sensor. We developed custom film coatings for the MOX sensors (SnO2, WO3 and NiO) which greatly improved the gas sensitivity, response time and lifetime of the miniature devices. Our proposed system exhibits promising performance for gas sensing in harsh environments, in terms of power consumption (∼ 35 mW at 350°C per MOX sensor), response time (<10 s), robustness and physical size. The sensing unit was evaluated with plumes of gases in both, a laboratory setup on a gas testing rig and on-board a mobile robot operating indoors. These high sensitivity, high-bandwidth sensors, together with online unsupervised gas discrimination algorithms, are able to detect and generate their spatial distribution maps accordingly. In the robotic experiments, the resulting gas distribution maps corresponded well to the actual location of the sources. Therefore, we verified its ability to differentiate gases and generate gas maps in real-world experiments.
- 2 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (24) , 12418-12431
FireNose on Mobile Robot in Harsh Environments
In this work we present a novel multi-sensor unit, a.k.a. FireNose, to detect and discriminate both known and unknown gases in uncontrolled conditions to aid firefighters under harsh conditions. The unit includes three metal oxide (MOX) gas sensors with CMOS micro heaters, a plasmonic enhanced non-dispersive infrared (NDIR) sensor optimized for the detection of CO2, a commercial temperature humidity sensor, and a flow sensor. We developed custom film coatings for the MOX sensors (SnO2, WO3 and NiO) which greatly improved the gas sensitivity, response time and lifetime of the miniature devices. Our proposed system exhibits promising performance for gas sensing in harsh environments, in terms of power consumption (∼ 35 mW at 350°C per MOX sensor), response time (<10 s), robustness and physical size. The sensing unit was evaluated with plumes of gases in both, a laboratory setup on a gas testing rig and on-board a mobile robot operating indoors. These high sensitivity, high-bandwidth sensors, together with online unsupervised gas discrimination algorithms, are able to detect and generate their spatial distribution maps accordingly. In the robotic experiments, the resulting gas distribution maps corresponded well to the actual location of the sources. Therefore, we verified its ability to differentiate gases and generate gas maps in real-world experiments.
- Open Access
Real-Time Thermal Modulation of High Bandwidth MOX Gas Sensors for Mobile Robot Applications
A new signal processing technique has been developed for resistive metal oxide (MOX) gas sensors to enable high-bandwidth measurements and enhanced selectivity at PPM levels (2, WO3 and NiO respectively, were operated and processed at the same time. This approach enables the removal of long-term baseline drift and is more resilient to changes in ambient temperature. It also greatly reduced the measurement time from ~10 s to 2 s or less. Bench-top experimental results are presented for 0 to 200 ppm of acetone, and 0 ppm to 500 ppm of ethanol. Our results demonstrate our sensor system can be used on a mobile robot for real-time gas sensing.
Open AccessReal-Time Thermal Modulation of High Bandwidth MOX Gas Sensors for Mobile Robot Applications
A new signal processing technique has been developed for resistive metal oxide (MOX) gas sensors to enable high-bandwidth measurements and enhanced selectivity at PPM levels (2, WO3 and NiO respectively, were operated and processed at the same time. This approach enables the removal of long-term baseline drift and is more resilient to changes in ambient temperature. It also greatly reduced the measurement time from ~10 s to 2 s or less. Bench-top experimental results are presented for 0 to 200 ppm of acetone, and 0 ppm to 500 ppm of ethanol. Our results demonstrate our sensor system can be used on a mobile robot for real-time gas sensing.
- Open Access
- 20 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 858
Thermal Modulation of a High-Bandwidth Gas Sensor Array in Real-Time for Application on a Mobile Robot
A new signal processing technique has been developed for resistive metal oxide (MOX) gas sensors to enable high-bandwidth measurements and enhanced selectivity at PPM levels (2, WO3, NiO) to be extracted using a fast Fourier transform. Signal processing is performed in real-time using a low-cost microcontroller integrated into a sensor module. The approach enables the remove of baseline drift and is resilient to environmental temperature changes. Bench-top experimental results are presented for 50 to 200 ppm of ethanol and CO, which demonstrate our sensor system can be used within a mobile robot.
- 20 November 2018
- Published by MDPI AG in Proceedings
- Vol. 2 (13) , 858
Open AccessThermal Modulation of a High-Bandwidth Gas Sensor Array in Real-Time for Application on a Mobile Robot
A new signal processing technique has been developed for resistive metal oxide (MOX) gas sensors to enable high-bandwidth measurements and enhanced selectivity at PPM levels (2, WO3, NiO) to be extracted using a fast Fourier transform. Signal processing is performed in real-time using a low-cost microcontroller integrated into a sensor module. The approach enables the remove of baseline drift and is resilient to environmental temperature changes. Bench-top experimental results are presented for 50 to 200 ppm of ethanol and CO, which demonstrate our sensor system can be used within a mobile robot.
- Open Access
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 421
High Bandwidth Sensor Module for Mobile Robot Applications-Wind Tunnel Characterization
We have developed a sensor module containing high-bandwidth VOC and gas sensors (including novel acoustic, custom MOX and low-cost NDIR) to evaluate the concentration of gases in a hazardous environment. We report upon the initial characterization of two MOX gas sensors (1 mm × 1 mm) with coatings of Pd/Pt doped SnO2 and pure WO3 inside a wind tunnel to plumes of acetone and ethanol (<10 ppm). The orientation and position of the sensor module in the tunnel was investigated. The unit was tested in a real-world environment with a VOC (propanol); fluctuating sensor responses demonstrated the formation of gas plumes.
- 25 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 421
Open AccessHigh Bandwidth Sensor Module for Mobile Robot Applications-Wind Tunnel Characterization
We have developed a sensor module containing high-bandwidth VOC and gas sensors (including novel acoustic, custom MOX and low-cost NDIR) to evaluate the concentration of gases in a hazardous environment. We report upon the initial characterization of two MOX gas sensors (1 mm × 1 mm) with coatings of Pd/Pt doped SnO2 and pure WO3 inside a wind tunnel to plumes of acetone and ethanol (<10 ppm). The orientation and position of the sensor module in the tunnel was investigated. The unit was tested in a real-world environment with a VOC (propanol); fluctuating sensor responses demonstrated the formation of gas plumes.
- 1 January 2003
- Published by Springer Nature in Inflammation Research
- Vol. 52 (1) , 32-38
5-Hydroxytryptamine-induced plasma extravasation in the rat knee joint is mediated by multiple prostaglandins
Objective and design: This study investigated whether prostaglandins (PGs) are involved in 5-hydroxytryptamine (5-HT)-induced synovial plasma extravasation.¶Materials and methods: Male Sprague-Dawley rat knee joints were perfused with 5-HT and synovial capillary Evans Blue dye leakage was measured using spectrophotometry. Cyclooxygenase (COX) inhibitors and PG receptor subtype-selective antagonists were tested for the ability to reduce 5-HT-induced synovial plasma extravasation.¶Results: 5-HT-induced plasma extravasation was inhibited by indomethacin. The COX-1 selective inhibitor SC-560 and the COX-2 selective inhibitor NS-398 were equally effective, indicating that both isoforms are involved. Antagonists selective for EP1, EP2 and DP receptor subtypes significantly attenuated the 5-HT-induced plasma extravasation. However, antagonists selective for FP, IP and TP subtypes failed to reduce 5-HT-induced plasma extravasation.¶Conclusions: These results demonstrate that multiple, but selective, subtypes of PGs mediate synovial plasma extravasation produced by 5-HT, and suggest that PGs act downstream of 5-HT in the inflammatory cascade.
- 1 January 2003
- Published by Springer Nature in Inflammation Research
- Vol. 52 (1) , 32-38
5-Hydroxytryptamine-induced plasma extravasation in the rat knee joint is mediated by multiple prostaglandins
Objective and design: This study investigated whether prostaglandins (PGs) are involved in 5-hydroxytryptamine (5-HT)-induced synovial plasma extravasation.¶Materials and methods: Male Sprague-Dawley rat knee joints were perfused with 5-HT and synovial capillary Evans Blue dye leakage was measured using spectrophotometry. Cyclooxygenase (COX) inhibitors and PG receptor subtype-selective antagonists were tested for the ability to reduce 5-HT-induced synovial plasma extravasation.¶Results: 5-HT-induced plasma extravasation was inhibited by indomethacin. The COX-1 selective inhibitor SC-560 and the COX-2 selective inhibitor NS-398 were equally effective, indicating that both isoforms are involved. Antagonists selective for EP1, EP2 and DP receptor subtypes significantly attenuated the 5-HT-induced plasma extravasation. However, antagonists selective for FP, IP and TP subtypes failed to reduce 5-HT-induced plasma extravasation.¶Conclusions: These results demonstrate that multiple, but selective, subtypes of PGs mediate synovial plasma extravasation produced by 5-HT, and suggest that PGs act downstream of 5-HT in the inflammatory cascade.