CTChieh Tsou

Chieh Tsou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chieh Tsou has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intelligent Wireless EEG Measurement System With Electrical and Optogenetic Stimulation for Epileptic Seizure Detection and Suppression

    by Wei-En Lee, Chieh Tsou, Zhan-Xian Liao, Po-Yen Lu, Tsung-Hsien Lin, Shuenn-Yuh Lee, Chou-Ching K. Lin, Gia-Shing Shieh

    A two-channel real-time intelligent electroencephalography (EEG) measurement system with electrical and optical stimulations is presented for seizure detection and suppression. Based on software control through a wireless interface, this system provides closed- and open-loop feedback control with programmable waveform for electrical and optical stimulations. Matlab graphical user interface is used to monitor the intracranial EEG, perform the algorithm for seizure detection, and adjust the required intensity, frequency, duty cycle, and duration of electrical and optical stimulations. The whole hardware device is embedded on a printed circuit board with the size of 27.3 mm ×23.6 mm. C57BL/6 mice with Thy1-ChR2-YFP gene transfer and drug-induced seizure are used to demonstrate epileptic seizure suppression according to electrical and optogenetic stimulation in the proposed wireless EEG measurement system.


  • Monitoring System With Cross-Type Capacitive Plantar Pressure Sensor

    by Tzung-Min Tsai, Chieh Tsou, Peng-Wei Huang, Shuenn-Yuh Lee, Soon-Jyh Chang

    This study presents a monitoring system with a 4 × 4 handmade cross-type capacitive plantar pressure (CCPP) sensor. This system includes a prototype detection module and a display interface, and it is implemented as a wearable device. The prototype detection module consists of a low dropout regulator (commercial IC) utilized to regulate a stable DC voltage with 3.7 V Li-ion battery for a whole wearable device and a customized capacitance-to-digital converter (CDC) chip is employed to convert capacitances into the digital data. The CDC includes a capacitance-to-voltage converter (CVC) and 10-bit successive approximation register analog-to-digital converter are fabricated via the TSMC 0.18 μm 1P6M 3.3 V process. CVC is characterized by its selectability of detection points from 1 to 64 (8 × 8 cross-type capacitive array). This type of converter is controlled by digital codes of a field-programmable gate array (FPGA) and has embedded functions of a self-separated input signal, which is applied to scan each detection point of the cross-type capacitive sensors, and a crosstalk attenuation (CA) is used to reduce parasitic capacitances and the effects of relative humidity and temperature of the environment for cross-type capacitive sensors. To demonstrate improvements of the CA, a multi-physics simulation software, COMSOL Multiphysics, was utilized to verify the performance of the CA. The handmade 4 × 4 CCPP sensor is modeled in COMSOL Multiphysics and simulated with/without CA. Finally, the simulated results reveal that the function of CA can reduce parasitic capacitances and the effects of the relative humidity and temperature caused by the environment effectively at the femtofarad level. The cross-type structure of a capacitive array has an advantage due to an M × N array, which only requires M + N tracks of input/output (I/O) ports to reduce the complexity of I/O connections. The measured results of the prototype detection module shown on the display interfaces reveal the positions and strengths of the corresponding capacitances of the CCPP sensor. The range of sensing capacitance is from 0 pF to 5.406 pF, the minimum sensing step is 15 fF, the accuracies of the handmade CCPP sensor and prototype detection module are -11.6/9.96 % and -8.65/5.54 %, respectively, and the sensitivity is 8 fF/N. The conversion time for one capacitance is 0.28 ms, and the maximum conversion time for 64 capacitances is 18.29 ms.


  • Single-Bin DFT-Based Digital Calibration Technique for CDAC in SAR ADCs

    by Shuenn-Yuh Lee, Chieh Tsou, Yu-Cheng Li

    A 1024-point single-bin discrete Fourier transform (SBDFT)-based digital calibration technique is presented for high-performance, full-code successive approximation (SAR) analog-to-digital converters (ADCs). This proposed method can evaluate the radix error in capacitor-DAC (CDAC), which deviates from the designed value. Thus, the corrected digital output codes are generated to compensate the error, thereby reducing the harmonic distortion caused by capacitor mismatch. Moreover, the proposed algorithm adopts a recursive SBDFT computation rather than a conventional fast Fourier transform (FFT) computation methods because the simple hardware, which reduces hardware complexity and power consumption, can be achieved to calculate a certain bin in this work. The effective number of bits (ENOB) and signal-to-noise ratio (SNDR) can be enhanced by approximately 2 bits and 14.52 dB, respectively, on the basis of the simulation result of a 12-bit SAR ADC behavior model with 0.3% capacitor mismatch. The proposed SAR ADC is fabricated in TSMC 0.18 μ m 1P6M technology. Measurement results explain that the SNDR, spurious free dynamic range, and ENOB are 46.49/67.28 dB, 49.66/80.73 dB, and 7.43/10.88 bits before/after calibration, respectively, wherein the power supply is 3.3 V and the input signal frequency is 2 kHz with a sampling rate of 100 kS/s.


  • Open Access

    Wireless energy‐harvesting circuit and system with error‐correction ASK demodulator for body sensor network with ultra‐high‐frequency RFID healthcare system

    by Shuenn‐Yuh Lee, Tsung‐Yen Chen, Chieh Tsou, Yuan‐Sun Chu

    This study presents a low‐power energy‐harvesting circuit with error‐correction demodulation for body sensor networks with radio‐frequency identification (RFID) systems. The proposed circuit adopts a new structure that facilitates the demodulation of amplitude‐shift‐keying (ASK) signals, and it includes a power unit consisting of a wake‐up circuit and a power‐on‐reset control circuit. The wireless bio‐signal acquisition system and the digital processor are implemented on a field‐programmable gate array to demonstrate the proposed RFID tag. The proposed energy‐harvesting circuit can substantially decrease the capacitance used by the demodulator circuit and the wake‐up circuit to as low as 14 pF. Moreover, a detection circuit and a correcting circuit are utilised to reduce the bit error rate of decoding. The wireless bio‐signal acquisition scenario is also set up and the communication signal between reader and tag is measured to demonstrate the system that can be employed in body sensor network with the healthcare system. The chip was implemented in complementary metal–oxide–semiconductor 0.18 μm technology. The sensitivity of this work is − 13 dBm. The pulse width error can be reduced to <1% by the error‐correction demodulator to fit the EPC Gen‐2 standard.