Rafael Casas has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Peter Stanley Lum
Department of Biomedical Engineering, The Catholic University of America, Washington, DC 20064, USA
4 shared publications - Dima A. Hammoud
Center for Infectious Disease Imaging, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, USA
3 shared publications William C. Reid
Center for Infectious Disease Imaging (CIDI), Radiology and Imaging Sciences, Clinical Center, National Institutes of Health (NIH), Bethesda, MD, United States
3 shared publicationsDianne E. Lee
Center for Infectious Disease Imaging (CIDI), Radiology and Imaging Sciences, National Institutes of Health, Bethesda, Maryland, United States of America
2 shared publicationsDragan Maric
Division of Intermural Research (DIR), National Institute of Neurological Disorders and Stroke (NINDS), National Institutes of Health, Bethesda, Maryland, United States of America
2 shared publicationsShawn J. DiRocco
Department of Biomedical Engineering, The Catholic University of America, Washington, DC, USA
2 shared publications
Latest Publications
- Open Access
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1509-1518
Flexor Synergy Assessment and Therapy for Persons With Stroke Using the ULIX Low Impedance Robot
The flexor synergy after stroke results in involuntary activation of distal muscles when lifting the shoulder against gravity. This contributes to impaired ability to perform activities of daily living. Robotic exoskeletons can be useful in assessing the strength of the synergy and applying therapy modes that promote improved movement patterns. In this study, we evaluated 16 chronic stroke patients using the Ultra Low Impedance eXoskelton (ULIX). The subjects performed two synergy assessment tasks, elbow extension and hand opening while holding shoulder flexion at greater than 70 degrees with various gravity support levels. Joints not part of the tasks were locked in place. During the assessment tasks, increasing gravity support resulted in more elbow extension and reduced grip force; however, EMG contraction ratios of distal muscles compared to deltoids increased when gravity support was increased. A free cup reaching task was performed using several proposed therapy modes. During the cup reaching task, the therapy modes increased range of motion and improved the shoulder-elbow kinematic coordination compared with gravity support alone. There was a strong correlation between synergy expression in the elbow extension task and performance of the cup reaching task. Isolating movement to shoulder flexion and elbow extension during the assessment task resulted in better elbow extension than in the cup reaching task where all joints were free to rotate.
- 18 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 1509-1518
Open AccessFlexor Synergy Assessment and Therapy for Persons With Stroke Using the ULIX Low Impedance Robot
The flexor synergy after stroke results in involuntary activation of distal muscles when lifting the shoulder against gravity. This contributes to impaired ability to perform activities of daily living. Robotic exoskeletons can be useful in assessing the strength of the synergy and applying therapy modes that promote improved movement patterns. In this study, we evaluated 16 chronic stroke patients using the Ultra Low Impedance eXoskelton (ULIX). The subjects performed two synergy assessment tasks, elbow extension and hand opening while holding shoulder flexion at greater than 70 degrees with various gravity support levels. Joints not part of the tasks were locked in place. During the assessment tasks, increasing gravity support resulted in more elbow extension and reduced grip force; however, EMG contraction ratios of distal muscles compared to deltoids increased when gravity support was increased. A free cup reaching task was performed using several proposed therapy modes. During the cup reaching task, the therapy modes increased range of motion and improved the shoulder-elbow kinematic coordination compared with gravity support alone. There was a strong correlation between synergy expression in the elbow extension task and performance of the cup reaching task. Isolating movement to shoulder flexion and elbow extension during the assessment task resulted in better elbow extension than in the cup reaching task where all joints were free to rotate.
- 1 December 2024
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 132 (6) , 1693-1703
Gravity support from a robotic exoskeleton increases spontaneous use of the nondominant upper extremity during a choice reaching task
We have shown that gravity support from a robotic exoskeleton increases use of the left arm of right-handed healthy participants. Prior work has shown similar results when movements of one arm are amplified in a virtual environment. The advantage of this approach is the potential to apply the intervention during functional task practice outside of the VR environment or during performance of actual activities of daily living (ADL).
- 1 December 2024
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 132 (6) , 1693-1703
Gravity support from a robotic exoskeleton increases spontaneous use of the nondominant upper extremity during a choice reaching task
We have shown that gravity support from a robotic exoskeleton increases use of the left arm of right-handed healthy participants. Prior work has shown similar results when movements of one arm are amplified in a virtual environment. The advantage of this approach is the potential to apply the intervention during functional task practice outside of the VR environment or during performance of actual activities of daily living (ADL).
- Open Access
- 16 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1877-1885
Clinical Test of a Wearable, High DOF, Spring Powered Hand Exoskeleton (HandSOME II)
In previous work, we developed an exoskeleton, Hand Spring Operated Movement Enhancer (HandSOME II), that allows movement at 15 hand degrees of freedom (DOF). Eleven separate elastic elements can be added to customize the extension assistance for individuals with impaired hand function. In this pilot study of twelve individuals with stroke, we measured the immediate improvements in range of motion (ROM) and upper extremity function when wearing the device. Index finger ROM was significantly improved at the PIP (p=.01) and DIP joints (p=.026), and the max extension was significantly increased at the MCP (p<; .001), PIP (p=.013) and DIP joints (p=.016). The thumb CMC abduction max (p=.017) and CMC flexion/extension ROM also increased (p=.04). In a grip and release task involving various objects, six subjects were unable to complete the tasks without assistance. Across these 6 subjects, 13 of 42 tasks were completed without assistance, while 36 of 42 tasks were completed when wearing HandSOME II. Despite the extension assistance provided by the device, flexion grip force was not statistically decreased. HandSOME II can potentially increase the effectiveness of repetitive task practice in patients with moderate-severe hand impairment by allowing completion of grasp and release tasks that are impossible to complete unassisted.
- 16 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1877-1885
Open AccessClinical Test of a Wearable, High DOF, Spring Powered Hand Exoskeleton (HandSOME II)
In previous work, we developed an exoskeleton, Hand Spring Operated Movement Enhancer (HandSOME II), that allows movement at 15 hand degrees of freedom (DOF). Eleven separate elastic elements can be added to customize the extension assistance for individuals with impaired hand function. In this pilot study of twelve individuals with stroke, we measured the immediate improvements in range of motion (ROM) and upper extremity function when wearing the device. Index finger ROM was significantly improved at the PIP (p=.01) and DIP joints (p=.026), and the max extension was significantly increased at the MCP (p<; .001), PIP (p=.013) and DIP joints (p=.016). The thumb CMC abduction max (p=.017) and CMC flexion/extension ROM also increased (p=.04). In a grip and release task involving various objects, six subjects were unable to complete the tasks without assistance. Across these 6 subjects, 13 of 42 tasks were completed without assistance, while 36 of 42 tasks were completed when wearing HandSOME II. Despite the extension assistance provided by the device, flexion grip force was not statistically decreased. HandSOME II can potentially increase the effectiveness of repetitive task practice in patients with moderate-severe hand impairment by allowing completion of grasp and release tasks that are impossible to complete unassisted.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (6) , 1464-1474
An Elbow Exoskeleton for Upper Limb Rehabilitation With Series Elastic Actuator and Cable-Driven Differential
Movement impairments resulting from neurologic injuries, such as stroke, can be treated with robotic exoskeletons that assist with movement retraining. Exoskeleton designs benefit from low impedance and accurate torque control. We designed a two-degrees-of-freedom tethered exoskeleton that can provide independent torque control on elbow flexion/extension and forearm supination/pronation. Two identical series elastic actuators (SEAs) are used to actuate the exoskeleton. The two SEAs are coupled through a novel cable-driven differential. The exoskeleton is compact and lightweight, with a mass of 0.9 kg. Applied rms torque errors were less than 0.19 Nm. Benchtop tests demonstrated a torque rise time of approximately 0.1 s, a torque control bandwidth of 3.7 Hz, and an impedance of less than 0.03 Nm/° at 1 Hz. The controller can simulate a stable maximum wall stiffness of 0.45 Nm/°. The overall performance is adequate for robotic therapy applications and the novelty of the design is discussed.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 35 (6) , 1464-1474
An Elbow Exoskeleton for Upper Limb Rehabilitation With Series Elastic Actuator and Cable-Driven Differential
Movement impairments resulting from neurologic injuries, such as stroke, can be treated with robotic exoskeletons that assist with movement retraining. Exoskeleton designs benefit from low impedance and accurate torque control. We designed a two-degrees-of-freedom tethered exoskeleton that can provide independent torque control on elbow flexion/extension and forearm supination/pronation. Two identical series elastic actuators (SEAs) are used to actuate the exoskeleton. The two SEAs are coupled through a novel cable-driven differential. The exoskeleton is compact and lightweight, with a mass of 0.9 kg. Applied rms torque errors were less than 0.19 Nm. Benchtop tests demonstrated a torque rise time of approximately 0.1 s, a torque control bandwidth of 3.7 Hz, and an impedance of less than 0.03 Nm/° at 1 Hz. The controller can simulate a stable maximum wall stiffness of 0.45 Nm/°. The overall performance is adequate for robotic therapy applications and the novelty of the design is discussed.
- Open Access
- 1 January 2018
- Published by Elsevier in NeuroImage: Clinical
- Vol. 17, 659-666
MR brain volumetric measurements are predictive of neurobehavioral impairment in the HIV-1 transgenic rat
- 1 January 2018
- Published by Elsevier in NeuroImage: Clinical
- Vol. 17, 659-666
Open AccessMR brain volumetric measurements are predictive of neurobehavioral impairment in the HIV-1 transgenic rat
- Open Access
- 24 March 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (3) , e0152265
Neurobehavioral Abnormalities in the HIV-1 Transgenic Rat Do Not Correspond to Neuronal Hypometabolism on 18F-FDG-PET
Motor and behavioral abnormalities are common presentations among individuals with HIV-1 associated neurocognitive disorders (HAND). We investigated whether longitudinal motor and behavioral performance in the HIV-1 transgenic rat (Tg), a commonly used neuro-HIV model, corresponded to in vivo neuronal death/dysfunction, by using rotarod and open field testing in parallel to [18F] 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET). We demonstrated that age-matched non-Tg wild type (WT) rats outperformed the HIV-1 Tg rats at most time points on rotarod testing. Habituation to rotarod occurred at 8 weeks of age (fifth weekly testing session) in the WT rats but it never occurred in the Tg rats, suggesting deficits in motor learning. Similarly, in open field testing, WT rats outperformed the Tg rats at most time points, suggesting defective exploratory/motor behavior and increased emotionality in the Tg rat. Despite the neurobehavioral abnormalities, there were no concomitant deficits in 18F-FDG uptake in Tg rats on PET compared to age-matched WT rats and no significant longitudinal loss of FDG uptake in either group. The negative PET findings were confirmed using 14C- Deoxy-D-glucose autoradiography in 32 week-old Tg and WT rats. We believe that the neuropathology in the HIV-1 Tg rat is more likely a consequence of neuronal dysfunction rather than overt neurodegeneration/neuronal cell death, similar to what is seen in HIV-positive patients in the post-ART era.
- 24 March 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (3) , e0152265
Open AccessNeurobehavioral Abnormalities in the HIV-1 Transgenic Rat Do Not Correspond to Neuronal Hypometabolism on 18F-FDG-PET
Motor and behavioral abnormalities are common presentations among individuals with HIV-1 associated neurocognitive disorders (HAND). We investigated whether longitudinal motor and behavioral performance in the HIV-1 transgenic rat (Tg), a commonly used neuro-HIV model, corresponded to in vivo neuronal death/dysfunction, by using rotarod and open field testing in parallel to [18F] 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET). We demonstrated that age-matched non-Tg wild type (WT) rats outperformed the HIV-1 Tg rats at most time points on rotarod testing. Habituation to rotarod occurred at 8 weeks of age (fifth weekly testing session) in the WT rats but it never occurred in the Tg rats, suggesting deficits in motor learning. Similarly, in open field testing, WT rats outperformed the Tg rats at most time points, suggesting defective exploratory/motor behavior and increased emotionality in the Tg rat. Despite the neurobehavioral abnormalities, there were no concomitant deficits in 18F-FDG uptake in Tg rats on PET compared to age-matched WT rats and no significant longitudinal loss of FDG uptake in either group. The negative PET findings were confirmed using 14C- Deoxy-D-glucose autoradiography in 32 week-old Tg and WT rats. We believe that the neuropathology in the HIV-1 Tg rat is more likely a consequence of neuronal dysfunction rather than overt neurodegeneration/neuronal cell death, similar to what is seen in HIV-positive patients in the post-ART era.
- 24 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9785, 978514-978514-6
Spatial context learning approach to automatic segmentation of pleural effusion in chest computed tomography images
- 24 March 2016
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9785, 978514-978514-6
Spatial context learning approach to automatic segmentation of pleural effusion in chest computed tomography images
- 1 March 2016
- Published by Elsevier in Journal of Neuroimmunology
- Vol. 292, 116-125
Characterization of neuropathology in the HIV-1 transgenic rat at different ages
- 1 March 2016
- Published by Elsevier in Journal of Neuroimmunology
- Vol. 292, 116-125
Characterization of neuropathology in the HIV-1 transgenic rat at different ages
- 1 January 2013
- Published by Elsevier in International Journal of Engineering Science
- Vol. 62, 106-112
Electrical resistivity of cortical bone: Micromechanical modeling and experimental verification
- 1 January 2013
- Published by Elsevier in International Journal of Engineering Science
- Vol. 62, 106-112
Electrical resistivity of cortical bone: Micromechanical modeling and experimental verification