KSKyubo Shin

Kyubo Shin

*This is an algorithmically generated author record based on publicly available information.

Kyubo Shin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Harnessing AI for Hypothyroidism Monitoring Using Wearable-Derived Heart Rate Data: Retrospective Cohort Study

    by Kyubo Shin, Yewon Jung, Won Sang Yoo, Min Joo Kim, Tae Jung Oh, Joon Ho Moon, Sung Hye Kong, Won Woo Lee, Jae Hoon Moon

    Background: Hypothyroidism is a prevalent endocrine disorder characterized by an insidious onset and nonspecific symptoms, often leading to significant diagnostic delays. While biochemical thyroid function tests (TFTs) are the gold standard, their invasive nature and cost make them impractical for continuous, proactive screening of at-risk populations. Thyroid hormones exert direct chronotropic effects on the cardiovascular system, and their levels are closely correlated with heart rate (HR). Wearable devices capable of continuous HR monitoring offer a novel opportunity for noninvasive, digital phenotype–based detection. Objective: This study aimed to develop and validate an AI-assisted system that uses wearable-derived sleep HR data as a digital monitoring tool for individuals at risk of hypothyroidism, helping identify those who warrant further confirmatory thyroid testing. Methods: This retrospective cohort study used 1677 paired observations consisting of sleep HR data and serum TFT results, including free thyroxine (T4) and thyroid-stimulating hormone levels, from 413 participants (mean age 43.1, SD 9.7 y; women: n=314, 76%). Participants wore consumer-grade wearables (Fitbit) that recorded HR and sleep data. Each TFT result was paired with sleep HR data extracted from the 15 consecutive nights preceding the blood test. An AI system was developed using a gradient boosting algorithm (LightGBM) to classify thyroid status by integrating baseline TFT results with statistical and temporal HR features. The model’s performance was evaluated using patient-level leave-one-out cross-validation. To examine the benefit of longitudinal data, performance was compared using 1, 2, or 3 prior paired observations as reference points. Results: To ensure clinical relevance and avoid performance inflation from hyperthyroid cases, we prioritized the analysis of a subset containing only euthyroid and hypothyroid data (n=744 paired observations). In this clinically challenging subset, the system achieved an accuracy of 74.6%, with a sensitivity of 82% and a specificity of 73.5% using a single-reference data pair. Incorporating longitudinal HR patterns further enhanced performance; using 3 reference pairs improved accuracy to 78.1% (sensitivity 81.8% and specificity 77.7%). In the overall dataset (n=1677 paired observations), the system demonstrated an accuracy of 80.8%, with a sensitivity of 82% and a specificity of 80.8% using a single-reference pair. Notably, the system achieved high clinical safety by detecting 96.3% of severe overt hypothyroidism cases (free T4 <0.5 ng/dL). Conclusions: This AI-assisted system demonstrates the feasibility of a sensitive, noninvasive longitudinal monitoring tool for hypothyroidism, robustly identifying a high proportion of hypothyroid cases—particularly severe ones—to prioritize at-risk individuals for confirmatory blood tests. Given the predominantly female iatrogenic-withdrawal cohort, prospective sex-balanced validation in primary hypothyroidism is warranted.

  • Generalisation of a deep learning-based exophthalmometry system using facial photographs for non-thyroidal orbital disease

    by Joonhyeon Park, Hyeong Ju Byeon, Kyubo Shin, HyunJo Jang, Jongchan Kim, Jaemin Park, Jin Sook Yoon, Jae Hoon Moon, JaeSang Ko

    Aims: To evaluate agreement between photo-based automated exophthalmometry and manual Hertel exophthalmometry in healthy individuals and patients with non-thyroidal orbital disease, with a deep learning system trained exclusively in thyroid eye disease (TED) cohorts applied without retraining or fine-tuning. Methods: This was a retrospective observational study. A total of 269 individuals were included in the study, including 95 healthy controls and 174 patients with unilateral non-TED orbital pathology. Automated measurements obtained using Glandy EXO from same-day frontal facial photographs were compared with corresponding manual Hertel exophthalmometry measurements. Agreement was assessed using Pearson correlation coefficient (PCC), mean absolute error (MAE), intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performance for clinically significant intereye asymmetry (>2.0 mm) was also evaluated. Results: The system showed good agreement with Hertel exophthalmometry in the eyes of healthy controls (PCC 0.80; MAE 0.86 mm; ICC 0.80) as well as the affected (PCC 0.81; MAE 1.41 mm; ICC 0.75) and fellow (PCC 0.76; MAE 1.03 mm; ICC 0.75) eyes of patients. Overall, 84.8% of measurements were within 2.0 mm of the manual Hertel values. The sensitivity, specificity and accuracy of the system for detecting clinically significant intereye asymmetry were 59.6%, 95.0% and 83.3%, respectively. Conclusions: The TED-trained photoexophthalmometry system showed good agreement with Hertel measurements in healthy individuals and patients with non-TED orbital disease. These findings support its use as an adjunct to clinical examination for objective quantification and documentation of globe position.

  • Open Access

    Deep Learning−Driven Exophthalmometry through Facial Photographs in Thyroid Eye Disease

    by Joonhyeon Park, Jin Sook Yoon, Namju Kim, Kyubo Shin, Hyun Young Park, Jongchan Kim, Jaemin Park, Jae Hoon Moon, JaeSang Ko


  • TAOD-Net: Automated detection and analysis of thyroid-associated orbitopathy in facial imagery

    by YongKyung Oh, Giheon Koh, Jiin Kwak, Kyubo Shin, Gi-Soo Kim, Min Joung Lee, Hokyung Choung, Namju Kim, Jae Hoon Moon, Sungil Kim


  • Open Access

    End-to-End Latency Prediction for General-Topology Cut-Through Switching Networks

    by Seokwoo Choi, Kyubo Shin, Hyoil Kim

    Low latency networking is gaining attention to support futuristic network applications like the Tactile Internet with stringent end-to-end latency requirements. In realizing the vision, cut-through (CT) switching is believed to be a promising solution to significantly reduce the latency of today's store-and-forward switching, by splitting a packet into smaller chunks called flits and forwarding them concurrently through input and output ports of a switch. Nevertheless, the end-to-end latency performance of CT switching has not been well studied in heterogeneous networks, which hinders its adoption to general-topology networks with heterogeneous links. To fill the gap, this paper proposes an end-to-end latency prediction model in a heterogeneous CT switching network, where the major challenge comes from the fact that a packet's end-to-end latency relies on how and when its flits are forwarded at each switch while each flit is forwarded individually. As a result, traditional packet-based queueing models are not instantly applicable, and thus we construct a method to estimate per-hop queueing delay via M/G/c queueing approximation, based on which we predict end-to-end latency of a packet. Our extensive simulation results show that the proposed model achieves 3.98-6.05% 90th-percentile error in end-to-end latency prediction.


  • TVWS assisted performance anomaly mitigation exploiting spectrum heterogeneity

    by Kyubo Shin, Hyoil Kim, Se Young Chun, Donghoon Shin