Hemin Ali Qadir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hemin Ali Qadir has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Ilangko Balasingham
The Intervention Centre, Oslo University Hospital, Oslo, 0372, Norway; Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications- Ilangko Balasingham
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications Jacob Bergsland
The Intervention Centre, Oslo University Hospital, Oslo, 0372, Norway
2 shared publications- Jacob Bergsland
Intervention Centre, Oslo University Hospital, Oslo, Norway
2 shared publications - Lars Aabakken
Univ. of Oslo
2 shared publications - Younghak Shin
Department of Electronic Systems, Norwegian University of Science and Technology, Trondheim, Norway
2 shared publications
Latest Publications
- Open Access
- 14 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107978
Multimodal deep learning for personalized renal cell carcinoma prognosis: Integrating CT imaging and clinical data
- 14 December 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 244, 107978
Open AccessMultimodal deep learning for personalized renal cell carcinoma prognosis: Integrating CT imaging and clinical data
- Open Access
Non-invasive Waveform Analysis for Emergency Triage via Simulated Hemorrhage: An Experimental Study using Novel Dynamic Lower Body Negative Pressure Model
The extent to which advanced waveform analysis of non-invasive physiological signals can diagnose levels of hypovolemia remains insufficiently explored. The present study explores the discriminative ability of a deep learning (DL) framework to classify levels of ongoing hypovolemia, simulated via novel dynamic lower body negative pressure (LBNP) model among healthy volunteers. We used a dynamic LBNP protocol as opposed to the traditional model, where LBNP is applied in a predictable step-wise, progressively descending manner. This dynamic LBNP version assists in circumventing the problem posed in terms of time dependency, as in real-life pre-hospital settings, intravascular blood volume may fluctuate due to volume resuscitation. A supervised DL-based framework for ternary classification was realized by segmenting the underlying noninvasive signal and labeling segments with corresponding LBNP target levels. The proposed DL model with two inputs was trained with respective time-frequency representations extracted on waveform segments to classify each of them into blood volume loss: Class 1 (mild); Class 2 (moderate); or Class 3 (severe). At the outset, the latent space derived at the end of the DL model via late fusion among both inputs assists in enhanced classification performance. When evaluated in a 3-fold cross-validation setup with stratified subjects, the experimental findings demonstrated PPG to be a potential surrogate for variations in blood volume with average classification performance, AUROC: 0.8861, AUPRC: 0.8141, $F1$-score:72.16%, Sensitivity:79.06 %, and Specificity:89.21 %. Our proposed DL algorithm on PPG signal demonstrates the possibility of capturing the complex interplay in physiological responses related to both bleeding and fluid resuscitation using this challenging LBNP setup.
Open AccessNon-invasive Waveform Analysis for Emergency Triage via Simulated Hemorrhage: An Experimental Study using Novel Dynamic Lower Body Negative Pressure Model
The extent to which advanced waveform analysis of non-invasive physiological signals can diagnose levels of hypovolemia remains insufficiently explored. The present study explores the discriminative ability of a deep learning (DL) framework to classify levels of ongoing hypovolemia, simulated via novel dynamic lower body negative pressure (LBNP) model among healthy volunteers. We used a dynamic LBNP protocol as opposed to the traditional model, where LBNP is applied in a predictable step-wise, progressively descending manner. This dynamic LBNP version assists in circumventing the problem posed in terms of time dependency, as in real-life pre-hospital settings, intravascular blood volume may fluctuate due to volume resuscitation. A supervised DL-based framework for ternary classification was realized by segmenting the underlying noninvasive signal and labeling segments with corresponding LBNP target levels. The proposed DL model with two inputs was trained with respective time-frequency representations extracted on waveform segments to classify each of them into blood volume loss: Class 1 (mild); Class 2 (moderate); or Class 3 (severe). At the outset, the latent space derived at the end of the DL model via late fusion among both inputs assists in enhanced classification performance. When evaluated in a 3-fold cross-validation setup with stratified subjects, the experimental findings demonstrated PPG to be a potential surrogate for variations in blood volume with average classification performance, AUROC: 0.8861, AUPRC: 0.8141, $F1$-score:72.16%, Sensitivity:79.06 %, and Specificity:89.21 %. Our proposed DL algorithm on PPG signal demonstrates the possibility of capturing the complex interplay in physiological responses related to both bleeding and fluid resuscitation using this challenging LBNP setup.
- Open Access
- 1 February 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 68, 101897
Toward real-time polyp detection using fully CNNs for 2D Gaussian shapes prediction
- 1 February 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 68, 101897
Open AccessToward real-time polyp detection using fully CNNs for 2D Gaussian shapes prediction
- Open Access
- 20 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 169537-169547
A Framework With a Fully Convolutional Neural Network for Semi-Automatic Colon Polyp Annotation
Deep learning has delivered promising results for automatic polyp detection and segmentation. However, deep learning is known for being data-hungry, and its performance is correlated with the amount of available training data. The lack of large labeled polyp training images is one of the major obstacles in performance improvement of automatic polyp detection and segmentation. Labeling is typically performed by an endoscopist, who performs pixel-level annotation of polyps. Manual polyp labeling of a video sequence is difficult and time-consuming. We propose a semi-automatic annotation framework powered by a convolutional neural network (CNN) to speed up polyp annotation in video-based datasets. Our CNN network requires only ground-truth (manually annotated masks) of a few frames in a video for training and annotating the rest of the frames in a semi-supervised manner. To generate masks similar to the ground-truth masks, we use some pre and post-processing steps such as different data augmentation strategies, morphological operations, Fourier descriptors, and a second stage fine-tuning. We use Fourier coefficients of the ground-truth masks to select similar generated output masks. The results show that it is possible to 1) produce ∼96% of Dice similarity score between the polyp masks provided by clinicians and the masks generated by our framework, and 2) save clinicians time as they need to manually annotate only a few frames instead of annotating the entire video, frame-by-frame.
- 20 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 169537-169547
Open AccessA Framework With a Fully Convolutional Neural Network for Semi-Automatic Colon Polyp Annotation
Deep learning has delivered promising results for automatic polyp detection and segmentation. However, deep learning is known for being data-hungry, and its performance is correlated with the amount of available training data. The lack of large labeled polyp training images is one of the major obstacles in performance improvement of automatic polyp detection and segmentation. Labeling is typically performed by an endoscopist, who performs pixel-level annotation of polyps. Manual polyp labeling of a video sequence is difficult and time-consuming. We propose a semi-automatic annotation framework powered by a convolutional neural network (CNN) to speed up polyp annotation in video-based datasets. Our CNN network requires only ground-truth (manually annotated masks) of a few frames in a video for training and annotating the rest of the frames in a semi-supervised manner. To generate masks similar to the ground-truth masks, we use some pre and post-processing steps such as different data augmentation strategies, morphological operations, Fourier descriptors, and a second stage fine-tuning. We use Fourier coefficients of the ground-truth masks to select similar generated output masks. The results show that it is possible to 1) produce ∼96% of Dice similarity score between the polyp masks provided by clinicians and the masks generated by our framework, and 2) save clinicians time as they need to manually annotate only a few frames instead of annotating the entire video, frame-by-frame.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 180-193
Improving Automatic Polyp Detection Using CNN by Exploiting Temporal Dependency in Colonoscopy Video
Automatic polyp detection has been shown to be difficult due to various polyp-like structures in the colon and high interclass variations in polyp size, color, shape and texture. An efficient method should not only have a high correct detection rate (high sensitivity) but also a low false detection rate (high precision and specificity). The state-of-the-art detection methods include convolutional neural networks (CNN). However, CNNs have shown to be vulnerable to small perturbations and noise; they sometimes miss the same polyp appearing in neighboring frames and produce a high number of false positives. We aim to tackle this problem and improve the overall performance of the CNN-based object detectors for polyp detection in colonoscopy videos. Our method consists of two stages: a region of interest (RoI) proposal by CNNbased object detector networks and a false positive (FP) reduction unit. The FP reduction unit exploits the temporal dependencies among image frames in video by integrating the bidirectional temporal information obtained by RoIs in a set of consecutive frames. This information is used to make the final decision. The experimental results show that the bidirectional temporal information has been helpful in estimating polyp positions and accurately predict the FPs. This provides an overall performance improvement in terms of sensitivity, precision and specificity compared to conventional false positive learning method, and thus achieves the state of the art results on the CVC-ClinicVideoDB video dataset.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 24 (1) , 180-193
Improving Automatic Polyp Detection Using CNN by Exploiting Temporal Dependency in Colonoscopy Video
Automatic polyp detection has been shown to be difficult due to various polyp-like structures in the colon and high interclass variations in polyp size, color, shape and texture. An efficient method should not only have a high correct detection rate (high sensitivity) but also a low false detection rate (high precision and specificity). The state-of-the-art detection methods include convolutional neural networks (CNN). However, CNNs have shown to be vulnerable to small perturbations and noise; they sometimes miss the same polyp appearing in neighboring frames and produce a high number of false positives. We aim to tackle this problem and improve the overall performance of the CNN-based object detectors for polyp detection in colonoscopy videos. Our method consists of two stages: a region of interest (RoI) proposal by CNNbased object detector networks and a false positive (FP) reduction unit. The FP reduction unit exploits the temporal dependencies among image frames in video by integrating the bidirectional temporal information obtained by RoIs in a set of consecutive frames. This information is used to make the final decision. The experimental results show that the bidirectional temporal information has been helpful in estimating polyp positions and accurately predict the FPs. This provides an overall performance improvement in terms of sensitivity, precision and specificity compared to conventional false positive learning method, and thus achieves the state of the art results on the CVC-ClinicVideoDB video dataset.