Marie-Valérie Moreno
Research Subjects
Research Interests
Marie-Valérie Moreno has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Michel Y. Jaffrin
Technological University of Compiegne, BP 20529
3 shared publications - Djamal Djeddi
Department of Pediatrics and Adolescent Medicine, Amiens University Hospital, 80000 Amiens, France
2 shared publications Eva Ribbe
BioparHom, Sport Research Department, Savoie Technolac, BP238, 73370 Le Bourget du Lac, France
2 shared publications- Roland Kieffer
Department of Bionanoscience, Kavli Institute of Nanoscience, Delft University of Technology, Delft, The Netherlands
2 shared publications - Anne-Sophie Belmont
Plateforme Transversale de Recherche Clinique de l’Institut de Cancérologie, Hospices Civils de Lyon, 69495 Pierre-Bénite, France
1 shared publication Arnaud Vannicatte
University of Techonology of Compiègne, Elite Sport Department, 60203 Compiègne, France
1 shared publication
Latest Publications
- Open Access
Assessing the Diagnostic Performance of a Smart Bra Using Temperature and Bioimpedance for Breast Cancer Detection: A First-in-Human Study
(1) Background: Breast cancer screening remains limited by mammography, particularly in younger women, in dense breast tissue, and in the detection of interval cancers. The PHI-BRA Smart Bra was developed as a wearable, non-invasive device combining thermography and bioimpedance for frequent breast monitoring. This first-in-human study aimed to assess the feasibility and in vivo diagnostic performance of the PHI-BRA system in discriminating between women with and without breast lesions. (2) Methods: A prospective feasibility study was conducted between March 2023 and February 2024. A calibration cohort (n = 15) was used to define the discrimination model, followed by an analysis cohort (n = 26; 13 with breast lesions and 13 without). Thermal and bioimpedance signals were acquired using the PHI-BRA device. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis, with mammography as the reference standard. (3) Results: In the analysis cohort, the temperature-based model achieved an area under the ROC curve (AUC) of 80.8% (95% CI [63.2–98.3]). At the optimal threshold, sensitivity was 84.6% (95% CI [61.5–100]) and specificity was 76.9% (95% CI [53.8–100]). Exploratory bioimpedance analyses showed lower sensitivity but high specificity, mainly limited by sensor contact stability. No adverse events were reported. (4) Conclusions: This first-in-human study demonstrates an initial exploration of the feasibility and safety of a wearable thermography-based approach for breast lesion discrimination. The results support further clinical validation of a multimodal wearable system as a complementary tool to existing breast cancer screening strategies.
Open AccessAssessing the Diagnostic Performance of a Smart Bra Using Temperature and Bioimpedance for Breast Cancer Detection: A First-in-Human Study
(1) Background: Breast cancer screening remains limited by mammography, particularly in younger women, in dense breast tissue, and in the detection of interval cancers. The PHI-BRA Smart Bra was developed as a wearable, non-invasive device combining thermography and bioimpedance for frequent breast monitoring. This first-in-human study aimed to assess the feasibility and in vivo diagnostic performance of the PHI-BRA system in discriminating between women with and without breast lesions. (2) Methods: A prospective feasibility study was conducted between March 2023 and February 2024. A calibration cohort (n = 15) was used to define the discrimination model, followed by an analysis cohort (n = 26; 13 with breast lesions and 13 without). Thermal and bioimpedance signals were acquired using the PHI-BRA device. Diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis, with mammography as the reference standard. (3) Results: In the analysis cohort, the temperature-based model achieved an area under the ROC curve (AUC) of 80.8% (95% CI [63.2–98.3]). At the optimal threshold, sensitivity was 84.6% (95% CI [61.5–100]) and specificity was 76.9% (95% CI [53.8–100]). Exploratory bioimpedance analyses showed lower sensitivity but high specificity, mainly limited by sensor contact stability. No adverse events were reported. (4) Conclusions: This first-in-human study demonstrates an initial exploration of the feasibility and safety of a wearable thermography-based approach for breast lesion discrimination. The results support further clinical validation of a multimodal wearable system as a complementary tool to existing breast cancer screening strategies.
- Open Access
- 21 July 2025
- Published by MDPI AG in Biophysica
- Vol. 5 (3) , 29
How to Improve the Repeatability, Reproducibility and Accuracy in the Dynamic Structuration of Water by Electromagnetic Waves?
This study represents a first step toward improving the repeatability, reproducibility, and accuracy of a process designed to enhance dynamic water structuring. We aim is to investigate the optical reflectivity of a watery magnesium chloride solution treated with electromagnetic waves, we employ a novel methodology derived from human plethysmography (PPG) with three wavelengths spanning the visible and infrared spectra. We measured the reflectance of 17 flasks at 536 nm, 660 nm, and 940 nm before and after treatment, first using the succussion method (control) and second using a 50 Hz signal. The observed variability was acceptable, with repeatability errors below 0.15% and reproducibility errors below 3.5% across all wavelengths before and after treatment. Out of 51 samples dynamically structured using the succussion method, we obtained two false negatives, while one false negative was recorded out of 51 samples dynamically structured using the electromagnetic (EM) method. PPG appears to be a relevant sensor, as it correctly detected dynamically structured water in 99 out of 102 cases, using either the succussion or electromagnetic method. Our results show significant differences in reflectance (supposedly correlated with water’s structured status) at 536 nm between dynamically structured and dynamic non-structured samples (p < 0.001). Future improvements will include a validation protocol against gold-standard spectrophotometry with a larger sample size.
- 21 July 2025
- Published by MDPI AG in Biophysica
- Vol. 5 (3) , 29
Open AccessHow to Improve the Repeatability, Reproducibility and Accuracy in the Dynamic Structuration of Water by Electromagnetic Waves?
This study represents a first step toward improving the repeatability, reproducibility, and accuracy of a process designed to enhance dynamic water structuring. We aim is to investigate the optical reflectivity of a watery magnesium chloride solution treated with electromagnetic waves, we employ a novel methodology derived from human plethysmography (PPG) with three wavelengths spanning the visible and infrared spectra. We measured the reflectance of 17 flasks at 536 nm, 660 nm, and 940 nm before and after treatment, first using the succussion method (control) and second using a 50 Hz signal. The observed variability was acceptable, with repeatability errors below 0.15% and reproducibility errors below 3.5% across all wavelengths before and after treatment. Out of 51 samples dynamically structured using the succussion method, we obtained two false negatives, while one false negative was recorded out of 51 samples dynamically structured using the electromagnetic (EM) method. PPG appears to be a relevant sensor, as it correctly detected dynamically structured water in 99 out of 102 cases, using either the succussion or electromagnetic method. Our results show significant differences in reflectance (supposedly correlated with water’s structured status) at 536 nm between dynamically structured and dynamic non-structured samples (p < 0.001). Future improvements will include a validation protocol against gold-standard spectrophotometry with a larger sample size.
- Open Access
Conception of a Phantom in Agar-Agar Gel with the Same Bio-Impedance Properties as Human Quadriceps
The physiology of the patient can be reflected by various data. Serious games, using an intelligent combination, could be based on this data to adjust to the specificities of the patient. Rehabilitation would therefore be personalized to the patient. This smart suit would use dry electrodes in order to be easily usable. Before performing dry electrode validation tests on a population, it is necessary to perform preliminary tests on a phantom. Agar-Agar (AA) gel, combined with NaCl and graphite which directly impact the resistivity and reactance values of the phantom, are generally used. Depending on the part of the body simulated by the phantom, it is necessary to adapt the concentrations of NaCl and graphite in order to obtain values of physiological reactance and resistance. The anisotropy of a muscle must also be considered. Different concentrations of NaCl and graphite have been tested in order to present charts linking the concentrations to the resistance and reactance values of the AA phantom. Electrical properties similar to those of human quadriceps are achieved at a concentration of 7 g/L of NaCl and 60 g/L of graphite. These values can be used as a conversion table to develop an AA phantom with electrical properties similar to different muscles. Furthermore, an AA phantom has an anisotropy of 0° and 90°. This anisotropy corresponds to a human quadriceps, where 0° is the direction of the muscle fiber. This will allow us to study and characterize the behavior of the electrodes on an anisotropic model. Thus it can be used as a first test phase for dry electrodes in order to propose the most suitable conditions for a connected garment application.
Open AccessConception of a Phantom in Agar-Agar Gel with the Same Bio-Impedance Properties as Human Quadriceps
The physiology of the patient can be reflected by various data. Serious games, using an intelligent combination, could be based on this data to adjust to the specificities of the patient. Rehabilitation would therefore be personalized to the patient. This smart suit would use dry electrodes in order to be easily usable. Before performing dry electrode validation tests on a population, it is necessary to perform preliminary tests on a phantom. Agar-Agar (AA) gel, combined with NaCl and graphite which directly impact the resistivity and reactance values of the phantom, are generally used. Depending on the part of the body simulated by the phantom, it is necessary to adapt the concentrations of NaCl and graphite in order to obtain values of physiological reactance and resistance. The anisotropy of a muscle must also be considered. Different concentrations of NaCl and graphite have been tested in order to present charts linking the concentrations to the resistance and reactance values of the AA phantom. Electrical properties similar to those of human quadriceps are achieved at a concentration of 7 g/L of NaCl and 60 g/L of graphite. These values can be used as a conversion table to develop an AA phantom with electrical properties similar to different muscles. Furthermore, an AA phantom has an anisotropy of 0° and 90°. This anisotropy corresponds to a human quadriceps, where 0° is the direction of the muscle fiber. This will allow us to study and characterize the behavior of the electrodes on an anisotropic model. Thus it can be used as a first test phase for dry electrodes in order to propose the most suitable conditions for a connected garment application.
- Open Access
Ocular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
Glaucoma causes total or partial loss of vision in 10% of people over the age of 70, increasing their fragility and isolation. It is characterised by the destruction of the optic nerve fibres, which may result from excessively high intraocular pressure as well as other phenomena. Diagnosis is currently reached through a combination of several checks, mainly of the eyes’ fundus, tonometry and gonioscopy. Prior to validation for human subjects, the objective of this study is to validate whether ocular phantom-based models could be used to diagnose glaucoma using an onboard system, which could, even at home, prevent the early-stage development of the pathology. Eight phantoms modelling healthy eyes and eight phantoms modelling eyes with glaucoma due to excessive intraocular pressure were measured using an onboard system, including lens and electrophysiology electronics. We measured the actual average Zr (real part of impedance) impedance of 160.9 ± 24.3 ohms (glaucoma ocular phantom models) versus 211.9 ± 36.9 ohms (healthy ocular phantom models), and an average total water volume (Vt) of 3.02 ± 0.35 mL (glaucoma ocular phantom models) versus 2.45 ± 0.28 mL (healthy ocular Phantoms). On average, we obtained 51 ohms (−24.1%) less and 0.57 mL (22.9%) of total water volume more, respectively. Normality tests (Shapiro–Wilk) for Vt and Zr indicate p < 0.001 and p < 0.01, respectively. Since these variables do not respect normal laws, unmatched Mann–Whitney tests were performed indicating a significant difference between Vt and Zr in the healthy ocular phantom models and those modelling glaucoma. To conclude, this preliminary study indicates the possibility of discriminating between healthy eyes with those with glaucoma. However, further large-scale studies involving healthy eyes and those suffering from glaucoma are necessary to generate viable models.
Open AccessOcular Phantom-Based Feasibility Study of an Early Diagnosis Device for Glaucoma
Glaucoma causes total or partial loss of vision in 10% of people over the age of 70, increasing their fragility and isolation. It is characterised by the destruction of the optic nerve fibres, which may result from excessively high intraocular pressure as well as other phenomena. Diagnosis is currently reached through a combination of several checks, mainly of the eyes’ fundus, tonometry and gonioscopy. Prior to validation for human subjects, the objective of this study is to validate whether ocular phantom-based models could be used to diagnose glaucoma using an onboard system, which could, even at home, prevent the early-stage development of the pathology. Eight phantoms modelling healthy eyes and eight phantoms modelling eyes with glaucoma due to excessive intraocular pressure were measured using an onboard system, including lens and electrophysiology electronics. We measured the actual average Zr (real part of impedance) impedance of 160.9 ± 24.3 ohms (glaucoma ocular phantom models) versus 211.9 ± 36.9 ohms (healthy ocular phantom models), and an average total water volume (Vt) of 3.02 ± 0.35 mL (glaucoma ocular phantom models) versus 2.45 ± 0.28 mL (healthy ocular Phantoms). On average, we obtained 51 ohms (−24.1%) less and 0.57 mL (22.9%) of total water volume more, respectively. Normality tests (Shapiro–Wilk) for Vt and Zr indicate p < 0.001 and p < 0.01, respectively. Since these variables do not respect normal laws, unmatched Mann–Whitney tests were performed indicating a significant difference between Vt and Zr in the healthy ocular phantom models and those modelling glaucoma. To conclude, this preliminary study indicates the possibility of discriminating between healthy eyes with those with glaucoma. However, further large-scale studies involving healthy eyes and those suffering from glaucoma are necessary to generate viable models.
- Open Access
Evaluation on Phantoms of the Feasibility of a Smart Bra to Detect Breast Cancer in Young Adults
Breast cancer is the most common cancer observed in women. Although mammography is a recognized method, it remains ionizing and cannot be used routinely or in young adults, leaving up to two years between two diagnoses. Prior to validation on human subjects, this study aims to validate on phantoms the feasibility of quantifying breast density and detecting breast cancer tumors using a smart bra in young women. Six phantoms with various densities and seven phantoms with various volumes of modelized tumor were prepared and measured with a smart bra, including an electrophysiological module. There was a significant difference between the “healthy phantoms” and the “tumor phantoms” with P(Student) = 0.008 (Shapiro–Wilk p = 0.846, samples follow a normal distribution; Fisher variance test, p = 0.287). In addition, this study seems to indicate the possibility of discriminating various types of tumorous and healthy breast tissue using a smart bra, in high density breast. However, a new study on a large sample of human subjects will be required to generate new models, including resistive, capacitive, and other sensor parameters versus reference data collected from imaging.
Open AccessEvaluation on Phantoms of the Feasibility of a Smart Bra to Detect Breast Cancer in Young Adults
Breast cancer is the most common cancer observed in women. Although mammography is a recognized method, it remains ionizing and cannot be used routinely or in young adults, leaving up to two years between two diagnoses. Prior to validation on human subjects, this study aims to validate on phantoms the feasibility of quantifying breast density and detecting breast cancer tumors using a smart bra in young women. Six phantoms with various densities and seven phantoms with various volumes of modelized tumor were prepared and measured with a smart bra, including an electrophysiological module. There was a significant difference between the “healthy phantoms” and the “tumor phantoms” with P(Student) = 0.008 (Shapiro–Wilk p = 0.846, samples follow a normal distribution; Fisher variance test, p = 0.287). In addition, this study seems to indicate the possibility of discriminating various types of tumorous and healthy breast tissue using a smart bra, in high density breast. However, a new study on a large sample of human subjects will be required to generate new models, including resistive, capacitive, and other sensor parameters versus reference data collected from imaging.
- 18 April 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 434
New reusable elastomer electrodes for assessing body composition
- 18 April 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 434
New reusable elastomer electrodes for assessing body composition
- Open Access
- 30 June 2010
- Published by Elsevier in Procedia Engineering
- Vol. 2 (2) , 3059-3064
Case study: using monitoring of body composition data obtained by bioimpedance, in training of an elite male runner
- 30 June 2010
- Published by Elsevier in Procedia Engineering
- Vol. 2 (2) , 3059-3064
Open AccessCase study: using monitoring of body composition data obtained by bioimpedance, in training of an elite male runner
- Open Access
- 1 June 2010
- Published by Elsevier in Procedia Engineering
- Vol. 2 (2) , 2881-2887
Bioimpedance data monitoring in physical preparation: A real interest for performance of elite skiers for Winter Olympic Games 2010
- 1 June 2010
- Published by Elsevier in Procedia Engineering
- Vol. 2 (2) , 2881-2887
Open AccessBioimpedance data monitoring in physical preparation: A real interest for performance of elite skiers for Winter Olympic Games 2010
- 1 April 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 224
Differentiation of fast and slow muscle fibers by bioimpedance
- 1 April 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 224
Differentiation of fast and slow muscle fibers by bioimpedance
- 1 January 2009
- Published by Springer Nature
- p. 517-524
Monitoring of Bioimpedance Data during Exercise in Cyclists (P247)
- 1 January 2009
- Published by Springer Nature
- p. 517-524
Monitoring of Bioimpedance Data during Exercise in Cyclists (P247)