Alexandre Kowalczuck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexandre Kowalczuck has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Ulisses Xavier da Silva Neto
Department of Endodontics, School of Health and Bioscience, Pontifical Catholic University of Paraná, Curitiba, Brazil
5 shared publications Everdan Carneiro
Postgraduate Program in Endodontics, School of Health and Biosciences of PUCPR, Curitiba, Paraná, Brazil
3 shared publications- Everdan Carneiro
Graduate Program in Dentistry Pontifical Catholic University of Paraná School of Medicine and Life Sciences Curitiba Brazil
3 shared publications Vânia Portela Ditzel Westphalen
Postgraduate Program in Endodontics, School of Health and Biosciences of PUCPR, Curitiba, Paraná, Brazil
3 shared publicationsAntonio Batista
2 shared publicationsC. A. H. Laurindo
Department of Mechanical Engineering, Polytechnic School, Pontifical Catholic University of Paraná, Curitiba, Brazil
2 shared publications
Latest Publications
- Open Access
- 19 December 2022
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 17 (04) , 1229-1234
Effect of Different Root Canal Drying Protocols on the Bond Strength of Two Bioceramic Sealers
Summary: Objectives This study evaluated in vitro the effect of two different drying protocols on the dentin bond strength of two different bioceramic sealers (Sealer Plus BC [SP] and Bio C Sealer [BCS]). Bond strength and failure mode were evaluated according to the sealer, drying protocol, and root canal third. Materials and Methods Sixty extracted human mandibular single-rooted premolars were selected after anatomical standardization. The crowns were sectioned and root canals were prepared. Roots were randomly divided into four groups (n = 15 each). Each group was assigned a combination of one of the evaluated sealers (SP or BCS) and one of the drying protocols: canals dried with paper points (PP) or irrigation with saline followed by aspiration with silicon cannulas (IA). Obturations were performed using a single-cone technique. The teeth were temporized and stored for 7 days (100% humidity, 37°C). Roots were cut to obtain 2 mm thick discs for each third (coronal, middle, and apical). Push-out tests were performed on a universal testing machine, and the bond strength (MPa) of each specimen was calculated by dividing the load (N) by the interface area. Failure type was assessed under ×4 magnification. Statistical Analysis Data were statistically analyzed with a significance set at 5%. An analysis of variance test followed by the Games-Howell post-hoc test was used to compare the mean values between the groups and the interaction of the variables. Results The predominant failure type was cohesive, followed by mixed failure and adhesive in all groups. The apical third presented the highest bond strength (p < 0.05) regardless of the group, followed by the middle and coronal thirds. Overall, the SP PP group had the highest mean bond strength (p < 0.01), but the SP sealer was negatively affected by the IA drying protocol in the coronal and middle thirds. The BCS presented similar results within the third stage, regardless of the drying protocol. Conclusions Sealer Plus BC had a higher bond strength than Bio C Sealer, but it was negatively affected by the irrigation-aspiration protocol in the coronal and middle thirds. For the apical third, there was no difference between the groups; thus, a similar bond strength was observed regardless of the drying protocol or sealer.
- 19 December 2022
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 17 (04) , 1229-1234
Open AccessEffect of Different Root Canal Drying Protocols on the Bond Strength of Two Bioceramic Sealers
Summary: Objectives This study evaluated in vitro the effect of two different drying protocols on the dentin bond strength of two different bioceramic sealers (Sealer Plus BC [SP] and Bio C Sealer [BCS]). Bond strength and failure mode were evaluated according to the sealer, drying protocol, and root canal third. Materials and Methods Sixty extracted human mandibular single-rooted premolars were selected after anatomical standardization. The crowns were sectioned and root canals were prepared. Roots were randomly divided into four groups (n = 15 each). Each group was assigned a combination of one of the evaluated sealers (SP or BCS) and one of the drying protocols: canals dried with paper points (PP) or irrigation with saline followed by aspiration with silicon cannulas (IA). Obturations were performed using a single-cone technique. The teeth were temporized and stored for 7 days (100% humidity, 37°C). Roots were cut to obtain 2 mm thick discs for each third (coronal, middle, and apical). Push-out tests were performed on a universal testing machine, and the bond strength (MPa) of each specimen was calculated by dividing the load (N) by the interface area. Failure type was assessed under ×4 magnification. Statistical Analysis Data were statistically analyzed with a significance set at 5%. An analysis of variance test followed by the Games-Howell post-hoc test was used to compare the mean values between the groups and the interaction of the variables. Results The predominant failure type was cohesive, followed by mixed failure and adhesive in all groups. The apical third presented the highest bond strength (p < 0.05) regardless of the group, followed by the middle and coronal thirds. Overall, the SP PP group had the highest mean bond strength (p < 0.01), but the SP sealer was negatively affected by the IA drying protocol in the coronal and middle thirds. The BCS presented similar results within the third stage, regardless of the drying protocol. Conclusions Sealer Plus BC had a higher bond strength than Bio C Sealer, but it was negatively affected by the irrigation-aspiration protocol in the coronal and middle thirds. For the apical third, there was no difference between the groups; thus, a similar bond strength was observed regardless of the drying protocol or sealer.
- 5 November 2019
- Published by Wiley in International Endodontic Journal
- Vol. 53 (4) , 513-518
Evaluation of fluoride and sodium hypochlorite solutions during the electrochemical dissolution of conventional NiTi instruments and Gold thermomechanically treated NiTi instruments
Aim To compare the dissolution time of two solutions, a fluoride solution and a sodium hypochlorite solution, both saturated with sodium chloride, during the electrochemical dissolution of instruments consisting of conventional nickel‐titanium alloy and Gold thermomechanically treated nickel‐titanium alloy. Methodology Two solutions, an NaF solution consisting of 12 g/L NaF with 180 g/L NaCl and an NaOCl solution consisting of 2.5% NaOCl with 180 g/L NaCl, were evaluated in a polarization test of a sample of 48 ProTaper Universal F1 (PTU F1) and WaveOne Gold Small (WOGS) instruments. The electric potentials were 0.5 V and 5 V for the NaF and NaOCl solutions, respectively. The electrochemical cell consisted of three electrodes for the polarization test of the PTU F1 and WOGS instruments, which had 6 mm of the tip immersed in the test solutions. The electric current was recorded for 540 s. If complete dissolution of the immersed tip occurred in less than the expected time, the experiment was considered complete. The time variations (in seconds) of the instruments in the solutions were measured. Data were subjected to statistical analysis using the Mann–Whitney, Kruskal–Wallis, and Dunn tests. The corrosion patterns of the instruments were evaluated by scanning electron microscopy (SEM). Results The NaF and NaOCl solutions were associated with significantly different (p=0.000) dissolution times of the instrument, with mean values of 12.96 s and 83.63 s, respectively. There was no significant difference (p=0.649) in dissolution time between the PTU F1 and WOGS instruments. Conclusions NaF and NaOCl solutions were able to electrochemically dissolve PTU F1 and WOGS instruments. However, the NaF solution achieved dissolution in significantly less time.
- 5 November 2019
- Published by Wiley in International Endodontic Journal
- Vol. 53 (4) , 513-518
Evaluation of fluoride and sodium hypochlorite solutions during the electrochemical dissolution of conventional NiTi instruments and Gold thermomechanically treated NiTi instruments
Aim To compare the dissolution time of two solutions, a fluoride solution and a sodium hypochlorite solution, both saturated with sodium chloride, during the electrochemical dissolution of instruments consisting of conventional nickel‐titanium alloy and Gold thermomechanically treated nickel‐titanium alloy. Methodology Two solutions, an NaF solution consisting of 12 g/L NaF with 180 g/L NaCl and an NaOCl solution consisting of 2.5% NaOCl with 180 g/L NaCl, were evaluated in a polarization test of a sample of 48 ProTaper Universal F1 (PTU F1) and WaveOne Gold Small (WOGS) instruments. The electric potentials were 0.5 V and 5 V for the NaF and NaOCl solutions, respectively. The electrochemical cell consisted of three electrodes for the polarization test of the PTU F1 and WOGS instruments, which had 6 mm of the tip immersed in the test solutions. The electric current was recorded for 540 s. If complete dissolution of the immersed tip occurred in less than the expected time, the experiment was considered complete. The time variations (in seconds) of the instruments in the solutions were measured. Data were subjected to statistical analysis using the Mann–Whitney, Kruskal–Wallis, and Dunn tests. The corrosion patterns of the instruments were evaluated by scanning electron microscopy (SEM). Results The NaF and NaOCl solutions were associated with significantly different (p=0.000) dissolution times of the instrument, with mean values of 12.96 s and 83.63 s, respectively. There was no significant difference (p=0.649) in dissolution time between the PTU F1 and WOGS instruments. Conclusions NaF and NaOCl solutions were able to electrochemically dissolve PTU F1 and WOGS instruments. However, the NaF solution achieved dissolution in significantly less time.
- 11 June 2019
- Published by Wiley in Microscopy Research and Technique
- Vol. 82 (9) , 1529-1534
Microscopic evaluation of the dentinal walls of extracted human teeth following electrochemical dissolution of fragmented nickel–titanium instruments
Electrochemical dissolution is a method in which fluoridated solution in direct contact with the fractured instrument receives an electrical current that speeds up fragment dissolution. The aim of this study was to assess the integrity of dentinal walls during the electrochemical dissolution of fractured rotary endodontic instruments in extracted human teeth. Forty‐five human mandibular incisors subjected to the electrochemical dissolution process using fluoride solution with low NaCl concentration (LC group: NaF 12 g/L + NaCl 1 g/L, pH = 5.0), fluoride solution with saturating NaCl concentration (SC group: NaF 12 g/L + NaCl 180 g/L, pH = 5.0) and distilled water (control group) were evaluated. For each group, 15 incisors were submitted for the scanning electron microscopy (SEM) evaluation. The roots were sectioned longitudinally; each hemisection was analyzed (n = 30), and energy‐dispersive spectroscopy (EDS) was performed. The amount of dentinal tubule openings was analyzed by SEM. Statistical analyses were performed. The test solutions did not alter the amount of dentinal tubule openings when compared with the control group. No Ni or Ti was impregnated into the dentinal tubules after electrochemical techniques. The dentinal structure remained unchanged following the electrochemical dissolution method.
- 11 June 2019
- Published by Wiley in Microscopy Research and Technique
- Vol. 82 (9) , 1529-1534
Microscopic evaluation of the dentinal walls of extracted human teeth following electrochemical dissolution of fragmented nickel–titanium instruments
Electrochemical dissolution is a method in which fluoridated solution in direct contact with the fractured instrument receives an electrical current that speeds up fragment dissolution. The aim of this study was to assess the integrity of dentinal walls during the electrochemical dissolution of fractured rotary endodontic instruments in extracted human teeth. Forty‐five human mandibular incisors subjected to the electrochemical dissolution process using fluoride solution with low NaCl concentration (LC group: NaF 12 g/L + NaCl 1 g/L, pH = 5.0), fluoride solution with saturating NaCl concentration (SC group: NaF 12 g/L + NaCl 180 g/L, pH = 5.0) and distilled water (control group) were evaluated. For each group, 15 incisors were submitted for the scanning electron microscopy (SEM) evaluation. The roots were sectioned longitudinally; each hemisection was analyzed (n = 30), and energy‐dispersive spectroscopy (EDS) was performed. The amount of dentinal tubule openings was analyzed by SEM. Statistical analyses were performed. The test solutions did not alter the amount of dentinal tubule openings when compared with the control group. No Ni or Ti was impregnated into the dentinal tubules after electrochemical techniques. The dentinal structure remained unchanged following the electrochemical dissolution method.
- Open Access
- 31 January 2019
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 22 (1) , 88-93
Fracture strength of teeth with access cavity preparation with operating microscope or on buccal surfaces
Objective: The present study assessed the fracture strength of teeth subjected to endodontic access cavity preparation on buccal surfaces, or with the aid of operating microscopy when compared to the conventional technique. Material and methods: Sixty mandibular incisors were split into four groups (n=15): conventional access cavity preparation (CCP); conservative (C); buccal surface (BS); and control. The canals were prepared and filled and the cavities were restored. A static compressive strength test was conducted until crown fracture. The force data were compiled and assessed statistically. Kolmogorov-Smirnov and Shapiro-Wilk tests were performed to assess normality, Levene’s test to assess variance homogeneity, the one-way ANOVA to compare fracture strength in the assessed groups. Tukey’s HSD test was used to determine whether the differences in the means were significant between the groups.Results: The experimental groups did not show any statistically significant differences in mean fracture strength (CCP = 585.65 N±107.64 N)(BS = 530.52 N±129.35 N) (C = 517.83 N±114.68 N). Conclusion: Therefore, the selection of surface or size of access cavity proposed did not influence the fracture strength of mandibular incisors when compared to conventional cavity preparation. KeywordsDental pulp cavity; Dental stress analysis; Root canal therapy.
- 31 January 2019
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 22 (1) , 88-93
Open AccessFracture strength of teeth with access cavity preparation with operating microscope or on buccal surfaces
Objective: The present study assessed the fracture strength of teeth subjected to endodontic access cavity preparation on buccal surfaces, or with the aid of operating microscopy when compared to the conventional technique. Material and methods: Sixty mandibular incisors were split into four groups (n=15): conventional access cavity preparation (CCP); conservative (C); buccal surface (BS); and control. The canals were prepared and filled and the cavities were restored. A static compressive strength test was conducted until crown fracture. The force data were compiled and assessed statistically. Kolmogorov-Smirnov and Shapiro-Wilk tests were performed to assess normality, Levene’s test to assess variance homogeneity, the one-way ANOVA to compare fracture strength in the assessed groups. Tukey’s HSD test was used to determine whether the differences in the means were significant between the groups.Results: The experimental groups did not show any statistically significant differences in mean fracture strength (CCP = 585.65 N±107.64 N)(BS = 530.52 N±129.35 N) (C = 517.83 N±114.68 N). Conclusion: Therefore, the selection of surface or size of access cavity proposed did not influence the fracture strength of mandibular incisors when compared to conventional cavity preparation. KeywordsDental pulp cavity; Dental stress analysis; Root canal therapy.
- Open Access
- 10 July 2018
- Vol. 13 (3) , 410-412
Management of Multiple Dental Trauma: Case Report with Eight-Year Follow-up
This case report documents the clinical approach adopted for two maxillary incisors with intrusion and horizontal root fracture in the middle third after trauma. The proposed procedures involved maintaining pulp vitality and periodontal stability of the fractured teeth with 8 years of follow-up.
- 10 July 2018
- Vol. 13 (3) , 410-412
Open AccessManagement of Multiple Dental Trauma: Case Report with Eight-Year Follow-up
This case report documents the clinical approach adopted for two maxillary incisors with intrusion and horizontal root fracture in the middle third after trauma. The proposed procedures involved maintaining pulp vitality and periodontal stability of the fractured teeth with 8 years of follow-up.
- Open Access
- 10 October 2017
- Vol. 12 (4) , 508-511
Maintenance of Pulp after Horizontal Root Fractures in Three Maxillary Incisors: A Thirteen-Year Evaluation
This case report documents the clinical approach adopted for three upper incisors with horizontal root fracture in the middle or cervical third. The proposed procedures involved maintaining pulp vitality and periodontal stability of the fractured teeth with 13 years of follow-up.
- 10 October 2017
- Vol. 12 (4) , 508-511
Open AccessMaintenance of Pulp after Horizontal Root Fractures in Three Maxillary Incisors: A Thirteen-Year Evaluation
This case report documents the clinical approach adopted for three upper incisors with horizontal root fracture in the middle or cervical third. The proposed procedures involved maintaining pulp vitality and periodontal stability of the fractured teeth with 13 years of follow-up.
- 1 January 2017
- Published by Dental Press International in Dental Press Endodontics
- Vol. 7 (1) , 92-96
Influência do comprimento das limas na qualidade do preparo do canal radicular
- 1 January 2017
- Published by Dental Press International in Dental Press Endodontics
- Vol. 7 (1) , 92-96
Influência do comprimento das limas na qualidade do preparo do canal radicular
- 14 May 2016
- Published by Wiley in International Endodontic Journal
- Vol. 50 (6) , 578-585
Electrochemical dissolution of fractured nickel–titanium instruments in human extracted teeth
Aim: To assess the effect of sodium chloride concentration in fluoridated solutions during the electrochemical dissolution of fractured rotary endodontic instruments.Methodology: Two solutions were assessed (solution 1: NaF 12 g L−1 + NaCl 1 g L−1, pH = 5.0; and solution 2: NaF 12 g L−1 + NaCl 180 g L−1, pH = 5.0) using two tests: the ProTaper Universal F1 (PTU F1) instrument polarization test and the polarization test for intracanal PTU F1 fragments fractured in mandibular incisors. In the first test, two sets of five instruments were separately and partially immersed in each solution, and the electrical current was evaluated over 30 min. In the second test, 45 PTU F1 instruments were fractured within the root canals of mandibular incisors and subjected to potentiodynamic polarization for 30 min. The electrical current and the variations in the length of PTU F1 fragments were measured. The data were analysed statistically (anova and Wilcoxon and Mann–Whitney tests, respectively).Results: Solution 2 was associated with more corrosive effects in both tests. In the first test, the PTU F1 instruments immersed in solution 2 had a higher electrical current (P < 0.001) and had a total dissolution time of approximately 540 s. In the second test, a larger difference between the baseline and final lengths of the fragments was noted in solution 2 (P = 0.011).Conclusion: Saturation of fluoridated solution with sodium chloride led to an increase in electrical current and microscopic reductions in the length of fractured instrument fragments subjected to electrochemical dissolution.
- 14 May 2016
- Published by Wiley in International Endodontic Journal
- Vol. 50 (6) , 578-585
Electrochemical dissolution of fractured nickel–titanium instruments in human extracted teeth
Aim: To assess the effect of sodium chloride concentration in fluoridated solutions during the electrochemical dissolution of fractured rotary endodontic instruments.Methodology: Two solutions were assessed (solution 1: NaF 12 g L−1 + NaCl 1 g L−1, pH = 5.0; and solution 2: NaF 12 g L−1 + NaCl 180 g L−1, pH = 5.0) using two tests: the ProTaper Universal F1 (PTU F1) instrument polarization test and the polarization test for intracanal PTU F1 fragments fractured in mandibular incisors. In the first test, two sets of five instruments were separately and partially immersed in each solution, and the electrical current was evaluated over 30 min. In the second test, 45 PTU F1 instruments were fractured within the root canals of mandibular incisors and subjected to potentiodynamic polarization for 30 min. The electrical current and the variations in the length of PTU F1 fragments were measured. The data were analysed statistically (anova and Wilcoxon and Mann–Whitney tests, respectively).Results: Solution 2 was associated with more corrosive effects in both tests. In the first test, the PTU F1 instruments immersed in solution 2 had a higher electrical current (P < 0.001) and had a total dissolution time of approximately 540 s. In the second test, a larger difference between the baseline and final lengths of the fragments was noted in solution 2 (P = 0.011).Conclusion: Saturation of fluoridated solution with sodium chloride led to an increase in electrical current and microscopic reductions in the length of fractured instrument fragments subjected to electrochemical dissolution.
- Open Access
- 1 January 2016
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 30 (1)
Evaluation of cutting ability and plastic deformation of reciprocating files
This in vitro study evaluated the cutting ability of reciprocating files and the deformations caused by their multiple use. Five Reciproc® R25 files were divided into five groups for 10 simulated root canal preparations each. The resin blocks were weighed and photographed (12.5X and 20X) before and after preparation. The canals were prepared according to the manufacturer’s instructions. Enlargement of the root canals was evaluated by comparison of pre- and post-preparation images using a computer software. The preoperative and postoperative weight differences determined the cutting ability of repeatedly used instruments. The data were analyzed using Lilliefors and Friedman statistical tests. The cutting ability and enlargement of the canals gradually decreased after each use, with significant differences observed at the 8th and 9th repetitions, respectively. There was no evidence of file deformation. The cutting ability and enlargement of the simulated canals gradually decreased when a reciprocating file was used up to 10 times.
- 1 January 2016
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 30 (1)
Open AccessEvaluation of cutting ability and plastic deformation of reciprocating files
This in vitro study evaluated the cutting ability of reciprocating files and the deformations caused by their multiple use. Five Reciproc® R25 files were divided into five groups for 10 simulated root canal preparations each. The resin blocks were weighed and photographed (12.5X and 20X) before and after preparation. The canals were prepared according to the manufacturer’s instructions. Enlargement of the root canals was evaluated by comparison of pre- and post-preparation images using a computer software. The preoperative and postoperative weight differences determined the cutting ability of repeatedly used instruments. The data were analyzed using Lilliefors and Friedman statistical tests. The cutting ability and enlargement of the canals gradually decreased after each use, with significant differences observed at the 8th and 9th repetitions, respectively. There was no evidence of file deformation. The cutting ability and enlargement of the simulated canals gradually decreased when a reciprocating file was used up to 10 times.
- Open Access
- 1 January 2015
- Published by Medknow in Indian Journal of Dental Research
- Vol. 26 (6) , 588-91
Influence of calcium hydroxide dressing and two irrigants on the filling of artificial lateral canals
Context: This study was carried out on the assumption that calcium hydroxide [Ca(OH) 2 ] dressing and irrigants may influence the obturation of lateral canals. Aims: To evaluate the influence of 2.5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX) gel and Ca(OH) 2 on the filling of artificial lateral canals. Settings and Design: Ex vivo quantitative laboratory study. Materials and Methods: Forty-two human mandibular premolars were selected. After cavity access, six lateral canals were performed, two in each root section, one mesial and one on the distal root surface. After preparation, the specimens were randomly divided into four groups: Group I: Under irrigation with 2% CHX and saline solution and with intracanal dressing Ca(OH) 2 paste; Group II: The same preparation as Group I, but without Ca(OH) 2 ; Group III: Under irrigation with 2.5% NaOCl without Ca(OH) 2 ; and Group IV: The same preparation as Group III, but with Ca(OH) 2 . Two teeth without intracanal dressing were used as negative controls. Lateral condensation technique was performed. Then, digital radiographic images were obtained. Statistical Analysis Used: Data were analyzed using SPSS 17.0, submitted to Kappa (reliability between examiners) and Kruskal-Wallis test. Results: No statistical difference was registered between Groups II and III in all root sections (P > 0.05), but it was observed between Groups I and IV (P < 0.05), except on the apical section (P > 0.05). In all sections, the Group I filled more artificial lateral canals than in Group IV. Conclusions: The irrigants tested had no influence on the filling of artificial lateral canals. Nevertheless, intracanal dressing of Ca(OH) 2 influenced this filling.
- 1 January 2015
- Published by Medknow in Indian Journal of Dental Research
- Vol. 26 (6) , 588-91
Open AccessInfluence of calcium hydroxide dressing and two irrigants on the filling of artificial lateral canals
Context: This study was carried out on the assumption that calcium hydroxide [Ca(OH) 2 ] dressing and irrigants may influence the obturation of lateral canals. Aims: To evaluate the influence of 2.5% sodium hypochlorite (NaOCl), 2% chlorhexidine (CHX) gel and Ca(OH) 2 on the filling of artificial lateral canals. Settings and Design: Ex vivo quantitative laboratory study. Materials and Methods: Forty-two human mandibular premolars were selected. After cavity access, six lateral canals were performed, two in each root section, one mesial and one on the distal root surface. After preparation, the specimens were randomly divided into four groups: Group I: Under irrigation with 2% CHX and saline solution and with intracanal dressing Ca(OH) 2 paste; Group II: The same preparation as Group I, but without Ca(OH) 2 ; Group III: Under irrigation with 2.5% NaOCl without Ca(OH) 2 ; and Group IV: The same preparation as Group III, but with Ca(OH) 2 . Two teeth without intracanal dressing were used as negative controls. Lateral condensation technique was performed. Then, digital radiographic images were obtained. Statistical Analysis Used: Data were analyzed using SPSS 17.0, submitted to Kappa (reliability between examiners) and Kruskal-Wallis test. Results: No statistical difference was registered between Groups II and III in all root sections (P > 0.05), but it was observed between Groups I and IV (P < 0.05), except on the apical section (P > 0.05). In all sections, the Group I filled more artificial lateral canals than in Group IV. Conclusions: The irrigants tested had no influence on the filling of artificial lateral canals. Nevertheless, intracanal dressing of Ca(OH) 2 influenced this filling.