Alexis Courtois
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexis Courtois has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Frederic Taillade
Performance, Risque Industriel et Surveillance pour la Maintenance et l’Exploitation (PRISME) Department, R&D Division, EDF, 78400 Chatou, France
2 shared publications Shahrokh Ghavamian
Numerical Engineering and Consulting Services (NECS), 196 rue Houdan, 92330 Sceaux, France
2 shared publicationsAbderrazzaq El-Yazidi
EDF SEPTEN, Villeurbanne, France
1 shared publicationAhmad Pouya
École Polytechnique
1 shared publicationB. Masson
Electricité de France, DTG, 12 rue Sainte Sidoine, 69003, Lyon, France
1 shared publicationBenoît Masson
1 shared publication
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contribution à la surveillance des structures épaisses en béton : proposition d'une démarche pour intégrer le suivi de la teneur en eau dans le pronostic
Cette recherche s’inscrit dans le cadre de la surveillance structurale des enceintes de confinement des centrales nucléaires qu’EDF exploite. L’objectif est de déterminer comment la connaissance de la teneur en eau du béton de ces ouvrages pourrait améliorer les prédictions de leur comportement mécanique, qui sont régulièrement réalisées dans le cadre de la démonstration de sûreté des installations.Dans un premier temps, nous avons étudié comment les incertitudes de mesure d’auscultation se propageaient dans les modèles pour quantifier l’information apportée par la mesure de teneur en eau. Nous avons également considéré les effets de ces incertitudes sur les extrapolations en fin de vie de l’ouvrage. Dans un second temps, nous avons proposé un modèle de surveillance des déformations différées comprenant la teneur en eau comme variable explicative et fondé sur une dépendance linéaire avec les déformations. Cette approche a été validée grâce aux données issues de la maquette VeRCoRs.Nous avons voulu ensuite estimer plus précisément l’exigence métrologique pour qualifier les chaines de mesure in situ de teneur en eau des bétons. Pour cela, nous avons utilisé la méthode de Monte Carlo pour simuler la propagation des incertitudes de mesures, en comparant les performances du modèle que nous proposions avec celles d’une approche d’ingénierie plus classique.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Contribution à la surveillance des structures épaisses en béton : proposition d'une démarche pour intégrer le suivi de la teneur en eau dans le pronostic
Cette recherche s’inscrit dans le cadre de la surveillance structurale des enceintes de confinement des centrales nucléaires qu’EDF exploite. L’objectif est de déterminer comment la connaissance de la teneur en eau du béton de ces ouvrages pourrait améliorer les prédictions de leur comportement mécanique, qui sont régulièrement réalisées dans le cadre de la démonstration de sûreté des installations.Dans un premier temps, nous avons étudié comment les incertitudes de mesure d’auscultation se propageaient dans les modèles pour quantifier l’information apportée par la mesure de teneur en eau. Nous avons également considéré les effets de ces incertitudes sur les extrapolations en fin de vie de l’ouvrage. Dans un second temps, nous avons proposé un modèle de surveillance des déformations différées comprenant la teneur en eau comme variable explicative et fondé sur une dépendance linéaire avec les déformations. Cette approche a été validée grâce aux données issues de la maquette VeRCoRs.Nous avons voulu ensuite estimer plus précisément l’exigence métrologique pour qualifier les chaines de mesure in situ de teneur en eau des bétons. Pour cela, nous avons utilisé la méthode de Monte Carlo pour simuler la propagation des incertitudes de mesures, en comparant les performances du modèle que nous proposions avec celles d’une approche d’ingénierie plus classique.
- 1 January 2018
- Published by Elsevier in Cement and Concrete Research
- Vol. 103, 140-159
A 12 year EDF study of concrete creep under uniaxial and biaxial loading
- 1 January 2018
- Published by Elsevier in Cement and Concrete Research
- Vol. 103, 140-159
A 12 year EDF study of concrete creep under uniaxial and biaxial loading
- 2 July 2017
- Published by ASME International
Innovative Methodology of Ranking Cooling Towers Based on Structural Safety Margin
EDF operates 28 natural draft cooling towers in nuclear power plants. The ageing of their atmospheric cooling tower shells is periodically monitored. Proactive maintenance strategies require ranking the towers according to the risk of failure and the observed damage. The ranking includes all sorts of monitoring data acquired at the plant: foundation settlements, material properties, quantified crack patterns, shell deformation and meteorological data... This combined ranking rely on two pillars: a ranking of the towers based on their shell surface faults observed on-site and another ranking based on their safety margin in terms of structural behavior. The aim of this paper is to present the second pillar of the ranking. The objective of the methodology is to calculate for each tower a failure quantitative risk index based on failure analysis of reinforced concrete. It includes three modules: a mechanical module which is the core module, an ageing module considering the carbonation and corrosion and a decisional module allowing ranking towers. Putting all towers on a ranking scale based on their global risk index allowing decision-maker to optimize their cooling tower maintenance program.
- 2 July 2017
- Published by ASME International
Innovative Methodology of Ranking Cooling Towers Based on Structural Safety Margin
EDF operates 28 natural draft cooling towers in nuclear power plants. The ageing of their atmospheric cooling tower shells is periodically monitored. Proactive maintenance strategies require ranking the towers according to the risk of failure and the observed damage. The ranking includes all sorts of monitoring data acquired at the plant: foundation settlements, material properties, quantified crack patterns, shell deformation and meteorological data... This combined ranking rely on two pillars: a ranking of the towers based on their shell surface faults observed on-site and another ranking based on their safety margin in terms of structural behavior. The aim of this paper is to present the second pillar of the ranking. The objective of the methodology is to calculate for each tower a failure quantitative risk index based on failure analysis of reinforced concrete. It includes three modules: a mechanical module which is the core module, an ageing module considering the carbonation and corrosion and a decisional module allowing ranking towers. Putting all towers on a ranking scale based on their global risk index allowing decision-maker to optimize their cooling tower maintenance program.
- 18 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1654-1663
Water Content Monitoring for Nuclear Concrete Buildings: Needs, Feedback and Perspectives
- 18 June 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 1654-1663
Water Content Monitoring for Nuclear Concrete Buildings: Needs, Feedback and Perspectives
- 30 May 2012
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 30 (4) , 1013-1024
Impedance Functions of Slab Foundations with Rigid Piles
- 30 May 2012
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 30 (4) , 1013-1024
Impedance Functions of Slab Foundations with Rigid Piles
- 1 March 2011
- Published by Elsevier in Engineering Structures
- Vol. 33 (3) , 796-812
Pseudo-dynamic tests on low-rise shear walls and simplified model based on the structural frequency drift
- 1 March 2011
- Published by Elsevier in Engineering Structures
- Vol. 33 (3) , 796-812
Pseudo-dynamic tests on low-rise shear walls and simplified model based on the structural frequency drift
- 1 June 2010
- Published by Elsevier in Engineering Structures
- Vol. 32 (6) , 1779-1790
Truss vs solid modeling of tendons in prestressed concrete structures: Consequences on mechanical capacity of a Representative Structural Volume
- 1 June 2010
- Published by Elsevier in Engineering Structures
- Vol. 32 (6) , 1779-1790
Truss vs solid modeling of tendons in prestressed concrete structures: Consequences on mechanical capacity of a Representative Structural Volume
- 1 July 2007
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 237 (12-13) , 1406-1418
Mechanical simulations of SANDIA II tests OECD ISP 48 benchmark
- 1 July 2007
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 237 (12-13) , 1406-1418
Mechanical simulations of SANDIA II tests OECD ISP 48 benchmark
- 1 November 2005
- Published by Elsevier in Engineering Geology
- Vol. 81 (3) , 269-283
Evaluation of a thermal criterion for an engineered barrier system
- 1 November 2005
- Published by Elsevier in Engineering Geology
- Vol. 81 (3) , 269-283
Evaluation of a thermal criterion for an engineered barrier system