JFJerry W. Froelich

Jerry W. Froelich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jerry W. Froelich has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The active papillary muscle sign in 18F-FDG PET/CT cardiac sarcoidosis exams and its relationship with myocardial suppression

    by Can Özütemiz, Yasemin Koksel, Jerry W. Froelich, Nathan Rubin, Maneesh Bhargava, Henri Roukoz, Rebecca Cogswell, Jeremy Markowitz, David M. Perlman, Daniel Steinberger

    Objective Papillary muscle (PM) activity may demonstrate true active cardiac sarcoidosis (CS) or mimic CS in 18FDG-PET/CT if adequate myocardial suppression (MS) is not achieved. We aim to examine whether PM uptake can be used as a marker of failed MS and measure the rate of PM activity presence in active CS with different dietary preparations. Materials and methods We retrospectively reviewed PET/CTs obtained with three different dietary preparations. Diet-A: 24-h ketogenic diet with overnight fasting (n = 94); Diet-B: 18-h fasting (n = 44); and Diet-C: 72-h daytime ketogenic diet with 3-day overnight fasting (n = 98). Each case was evaluated regarding CS diagnosis (negative, positive, and indeterminant) and presence of PM activity. MaxSUV was measured from bloodpool, liver, and the most suppressed normal myocardium. Linear mixed-effects models were used to compare these factors between those with PM activity and those without. Results PM activity was markedly lower in the Diet-C group compared with others: Diet-C: 6 (6.1%), Diet-A: 36 (38.3%), and Diet-B: 26 (59.1%) (p < 0.001). MyocardiumMaxSUV was higher, and MyocardiummaxSUV/BloodpoolmaxSUV, MyocardiummaxSUV/LivermaxSUV ratios were significantly higher in the cases with PM activity (p < 0.001). Among cases that used Diet-C and had PM activity, 66.7% were positive and 16.7% were indeterminate. If Diet-A or Diet-B was used, those with PM activity had a higher proportion of indeterminate cases (Diet-A: 61.1%, Diet-B: 61.5%) than positive cases (Diet-A: 36.1%, Diet-B: 38.5%). Conclusion Lack of PM activity can be a sign of appropriate MS. PM activity is less common with a specific dietary preparation (72-h daytime ketogenic diet with 3-day overnight fasting), and if it is present with this particular preparation, the likelihood that the case being true active CS might be higher than the other traditional dietary preparations.


  • Open Access

    Supplementary Materials from Safe and Effective Sarcoma Therapy through Bispecific Targeting of EGFR and uPAR

    by Antonella Borgatti, Joseph S. Koopmeiners, Aaron L. Sarver, Amber L. Winter, Kathleen Stuebner, Deborah Todhunter, Anthony E. Rizzardi, Jonathan C. Henriksen, Stephen Schmechel, Colleen L. Forster, et al.

  • Open Access

    Supplementary Materials from Safe and Effective Sarcoma Therapy through Bispecific Targeting of EGFR and uPAR

    by Antonella Borgatti, Joseph S. Koopmeiners, Aaron L. Sarver, Amber L. Winter, Kathleen Stuebner, Deborah Todhunter, Anthony E. Rizzardi, Jonathan C. Henriksen, Stephen Schmechel, Colleen L. Forster, et al.

  • A bicentric retrospective analysis of clinical utility of 18F-fluciclovine PET in biochemically recurrent prostate cancer following primary radiation therapy: is it helpful in patients with a PSA rise less than the Phoenix criteria?

    by Ali Salavati, Mehmet Gencturk, Yasemin Koksel, Allyssa N. Schik, Peter R. Carroll, Felix Y. Feng, Steven P. Rowe, Courtney Lawhn-Heath, Thomas A. Hope, Jerry W. Froelich

    Purpose 18F-Fluciclovine PET imaging has been increasingly used in the restaging of prostate cancer patients with biochemical recurrence (BCR); however, its clinical utility in patients with low prostate-specific antigen (PSA) levels following primary radiation therapy has not been well-studied. This study aims to determine the detection rate and diagnostic accuracy of 18F-fluciclovine PET and the patterns of prostate cancer recurrence in patients with rising PSA after initial radiation therapy, particularly in patients with PSA levels below the accepted Phoenix definition of BCR (PSA nadir +2 ng/mL). Methods This retrospective study included patients from two tertiary institutions who underwent 18F-fluciclovine PET scans for elevated PSA level following initial external beam radiation therapy, brachytherapy, and/or proton therapy. Logistic regression and receiver operating characteristic (ROC) curve analyses were performed to determine the diagnostic accuracy of 18F-fluciclovine PET and associations of PSA kinetic parameters with 18F-fluciclovine PET outcome. Results One hundred patients were included in this study. The overall detection rate on a patient-level was 79% (79/100). 18F-Fluciclovine PET was positive in 62% (23/37) of cases with PSA below the Phoenix criteria. The positive predictive value of 18F-fluciclovine PET was 89% (95% CI: 80–94%). In patients with PSA below the Phoenix criteria, the PSA velocity had the highest predictive value of 18F-fluciclovine PET outcome. PSA doubling time (PSADT) and PSA velocity were associated with the presence of extra-pelvic metastatic disease. Conclusion 18F-Fluciclovine PET can identify recurrent disease at low PSA level and PSA rise below accepted Phoenix criteria in patients with suspected BCR after primary radiation therapy, particularly in patients with low PSADT or high PSA velocity. In patients with low PSADT or high PSA velocity, there is an increased probability of extra-pelvic metastases. Therefore, these patients are more likely to benefit from PET/CT or PET/MRI than pelvic MRI alone.


  • Open Access

    ROC study and SUV threshold using quantitative multi-modal SPECT for bone imaging

    by A. H. Vija, P. A. Bartenstein, J. W. Froelich, T. Kuwert, H. Macapinlac, C. P. Daignault, N. Gowda, O. Hadjiev, J. Hephzibah, P. Huang, et al.

    We investigated the clinical performance of a quantitative multi-modal SPECT/CT reconstruction platform for yielding radioactivity concentrations of bone imaging with 99mTc-methylene diphosphonate (MDP) or 99mTc-dicarboxypropane diphosphonate (DPD). The novel reconstruction incorporates CT-derived tissue information while preserving the delineation of tissue boundaries. We assessed image-based reader concordance and confidence, and determined lesion classification and SUV thresholds from ROC analysis. Seventy-two cancer patients were scanned at three US and two German clinical sites, each contributing two experienced board-certified nuclear medicine physicians as readers. We compared four variants of the reconstructed data resulting from the Flash3D (F3D) and the xSPECT Bone™ (xB) iterative reconstruction methods and presented images to the readers with and without a fused CT, resulting in four combinations. We used an all-or-none approach for inclusion, compiling results only when a reader completed all reads in a subset. After the final read, we conducted a “surrogate truth” reading, presenting all data to each reader. For any remaining discordant lesions, we conducted a consensus read. We next undertook ROC analysis to determine SUV thresholds for differentiating benign and lesional uptake. On a five-point rating scale of image quality, xB was deemed better by almost two points in resolution and one point better in overall acceptance compared to F3D. The absolute agreement of the rendered decision between the nine readers was significantly higher with CT information either inside the reconstruction (xB, xBCT) or simply through image fusion (F3DCT): 0.70 (xBCT), 0.67 (F3DCT), 0.64 (xB), and 0.46 (F3D). The confidence level to characterize the lesion was significantly higher (3.03x w/o CT, 1.32x w/CT) for xB than for F3D. There was high correlation between xB and F3D scores for lesion detection and classification, but lesion detection confidence was 41% higher w/o CT, and 21% higher w/CT for xB compared to F3D. Without CT, xB had 6.6% higher sensitivity, 7.1% higher specificity, and 6.9% greater AUC compared to F3D, and similarly with CT-fusion. The overall SUV-criterion (SUVc) of xB (12) exceeded that for xSPECT Quant™ (xQ; 9), an approach not using the tissue delineation of xB. SUV critical numbers depended on lesion volume and location. For non-joint lesions > 6 ml, the AUC for xQ and xB was 94%, with SUVc > 9.28 (xQ) or > 9.68 (xB); for non-joint lesions ≤ 6 ml, AUCs were 81% (xQ) and 88% (xB), and SUVc > 8.2 (xQ) or > 9.1 (xB). For joint lesions, the AUC was 80% (xQ) and 83% (xB), with SUVc > 8.61 (xQ) or > 13.4 (xB). The incorporation of high-resolution CT-based tissue delineation in SPECT reconstruction (xSPECT Bone) provides better resolution and detects smaller lesions (6 ml), and the CT component facilitates lesion characterization. Our approach increases confidence, concordance, and accuracy for readers with a wide range of experience. The xB method retained high reading accuracy, despite the unfamiliar image presentation, having greatest impact for smaller lesions, and better localization of foci relative to bone anatomy. The quantitative assessment yielded an SUV-threshold for sensitively distinguishing benign and malignant lesions. Ongoing efforts shall establish clinically usable protocols and SUV thresholds for decision-making based on quantitative SPECT.


  • Standardized MR Terminology and Reporting of Implants and Devices as Recommended by the American College of Radiology Subcommittee on MR Safety

    by Emanuel Kanal, Jerry Froelich, A. James Barkovich, James Borgstede, William Bradley, J. Rod Gimbel, John Gosbee, Todd Greenberg, Edward Jackson, Paul Larson, et al.

    The American College of Radiology, through its Subcommittee on MR Safety, has proposed standardized terminology that will contribute to greater safety and understanding for screening metal implants and/or devices prior to MR imaging. Considerable confusion exists among the magnetic resonance (MR) imaging user community as to how to determine whether a patient with a metal implanted device can be safely imaged in an MR imaging unit. Although there has been progress by the device manufacturers in specifying device behavior in a magnetic field, and some MR imaging manufacturers provide maps of the “spatial gradients,” there remains significant confusion because of the lack of standardized terminology and reporting guidelines. The American College of Radiology, through its Subcommittee on MR Safety, has proposed standardized terminology that will contribute to greater safety and understanding for screening metal implants and/or devices prior to MR imaging.© RSNA, 2014