Thomas J. Vogl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas J. Vogl has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Adrian K. Dixon
Addenbrooke´s Hospital
2 shared publications - Achim Hagen
Department of Vascular Surgery and Endovascular Surgery, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072 Koblenz, Germany
1 shared publication - Christian Booz
Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
1 shared publication - Daniel Dillinger
Department of Vascular Surgery and Endovascular Surgery, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072 Koblenz, Germany
1 shared publication - Daniel Overhoff
Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072 Koblenz, Germany
1 shared publication - Hanns Leonhard Kaatsch
Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072 Koblenz, Germany
1 shared publication
Latest Publications
- Open Access
- 1 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (5) , 938
Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels
Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. Results: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. Conclusions: Our data suggest that VMI at 60–70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.
- 1 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (5) , 938
Open AccessImpact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels
Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. Results: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. Conclusions: Our data suggest that VMI at 60–70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.
- 7 April 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (8) , 1528-1531
Recent literature
- 7 April 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (8) , 1528-1531
Recent literature
- 6 January 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (7) , 1316-1317
Intravenous leiomyomatosis
- 6 January 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (7) , 1316-1317
Intravenous leiomyomatosis
- 26 April 2003
- Published by Springer Nature in European Radiology
- Vol. 13 (6) , 1483-1488
Recent Literature
- 26 April 2003
- Published by Springer Nature in European Radiology
- Vol. 13 (6) , 1483-1488
Recent Literature