Latest Publications

  • Open Access

    Letter to: Corneal collagen cross-linking by sun exposure and high dose oral riboflavin: a multicentric longitudinal observational study

    by Emilio A. Torres, M. Enes Aydemir, Nan-Ji Lu, Sabine Kling, Nikki L. Hafezi, Mark Hillen, Michalina L. Depczyńska, Farhad Hafezi

    STUDY DESIGN LIMITATIONS The authors report a retrospective, uncontrolled, multicenter series of 53 patients, with attrition to 42 patients after only 6 months. The absence of a control group or blinding means that natural variability, regression to the mean, or periods of spontaneous stability cannot be excluded as explanations for their findings. The authors acknowledge that “the absence of a control group and blinding, as well as the relatively small number of individuals followed, can be mentioned”. Furthermore, the inclusion [...] STUDY DESIGN LIMITATIONS The authors report a retrospective, uncontrolled, multicenter series of 53 patients, with attrition to 42 patients after only 6 months. The absence of a control group or blinding means that natural variability, regression to the mean, or periods of spontaneous stability cannot be excluded as explanations for their findings. The authors acknowledge that “the absence of a control group and blinding, as well as the relatively small number of individuals followed, can be mentioned”. Furthermore, the inclusion

  • Open Access

    Roadmap on advances in visual and physiological optics

    by Jesús E Gómez-Correa, Brian Vohnsen, Barbara K Pierścionek, Sabino Chávez-Cerda, Sabine Kling, Jos J Rozema, Raymond A Applegate, Giuliano Scarcelli, J Bradley Randleman, Alexander V Goncharov, et al.

    The field of visual and physiological optics is undergoing continuous significant advancements, driven by a deeper understanding of the human visual system and the development of cutting-edge optical technologies. This Roadmap, authored by leading experts, delves into critical areas such as corneal biomechanical properties, keratoconus, and advancements in corneal imaging and elastography. It explores the intricate structure–function relationship within the eye lens, offering new perspectives through lens models and ray tracing techniques. The document also covers advancements in retinal imaging, highlighting the current state and future directions, and the role of adaptive optics in evaluating retinal structure and function in both healthy and diseased eyes. Furthermore, it addresses the modeling of ocular surfaces using different mathematical functions and examines the factors affecting peripheral image quality in the human eye, emphasizing the importance of these aspects in visual performance. Additional topics include schematic and functional models of the human eye, the impact of optical and chromatic aberrations, and the design of contact, and intraocular lenses. Finally, the Roadmap addresses the intersection of neurosciences with vision health, presenting a comprehensive overview of current research and future trends aimed at improving visual health and optical performance. Ultimately, this Roadmap aims to serve as a valuable resource for ophthalmologists, optometrists, vision scientists, and engineers dedicated to advancing the field of visual and physiological optics.


  • Open Access

    Editorial: Optobiomechanics of the eye

    by Sabine Kling, Anna Pandolfi, Norberto Lopez‐Gil, Jos Rozema

    The relationship between IOP and ocular biomechanics has been investigated at multiple levels, from tissuespecific alterations to whole-eye deformation responses. B. Ma et al. explored how chronic high IOP alters the mechanical properties of the lamina cribrosa (LC) and retinal ganglion cell (RGC) axons. Using atomic force microscopy on a rat glaucoma model, the authors documented a time-dependent reduction in stiffness of both LC glial tissue and RGC axons, with up to 80% loss in modulus over 12 weeks. This weakening likely contributes to axonal vulnerability and progressive glaucomatous damage, emphasizing the need for therapies that preserve or restore LC integrity. Extending the focus from local tissue mechanics to global ocular responses, two other studies applied air-puff tonometry to connect corneal and scleral responses to IOP. E. Redaelli et al. developed a computational model to simulate corneal deformation under air-puff tonometry, addressing the fact that traditional measures are confounded by corneal thickness and the tissue's mechanical properties. By shifting the analysis toward the timing of maximum apex velocity, the authors propose a more reliable IOP estimator less dependent on corneal properties. Using the same air-puff tonometry, A. De La Hoz et al. examined scleral biomechanics in rabbits in combination with computational modeling. Their findings showed scleral stiffness strongly influences deformation responses, suggesting that this non-invasive tool could provide valuable biomechanical markers for myopia and glaucoma risk evaluation.Although crucial to the process of accommodation, the biomechanical behavior of the crystalline lens is not yet entirely understood. A. Dahaghin et al. introduced a biomechanical model of lens "wobbling," the oscillatory motion that occurs after rapid eye movement. By combining Purkinje image analysis with optobiomechanical simulations, the authors reproduced oscillation frequencies and damping factors observed in vivo, while also revealing subject-specific variability. This work sets the stage for personalized lens models that could deepen our understanding of ocular biomechanical mechanisms. V. Tahsini et al. examined how preservation methods alter the mechanical properties of ex vivo porcine lenses. Using optical coherence elastography and inverse finite-element analysis, the authors showed that freezing significantly alters cortical and nuclear strains, while refrigeration preserves the lens' mechanical properites best. Removal of the capsule changed the strain distribution across lens nucleus and cortex. These findings are essential for interpreting ex vivo experiments and designing standardized protocols for lens biomechanics research.Taken together, these eleven contributions provide a rich insight in the evolving field of optobiomechanics. From synchrotron scattering to, air-puff tonometry, OCT elastography, machine learning and numerical simulations, diverse methods are converging to give a more complete picture of ocular biomechanics. Studies on corneal cross-linking, scleral stiffness, and lamina cribrosa degradation deepen our understanding of disease and treatment mechanisms. Computational models and predictive algorithms are directly informing refractive surgery screening and IOP measurement, while non-invasive imaging modalities offer prospects for routine biomechanical monitoring. The continued growth of optobiomechanics will rely on interdisciplinary collaborations across physics, biology, engineering, and clinical sciences, ultimately driving innovations that improve patient care and visual performance.

  • Open Access

    Optical coherence tomography quantifies gradient refractive index and mechanical stiffness gradient across the human lens

    by Sabine Kling, Matteo Frigelli, M. Enes Aydemir, Vahoora Tahsini, Emilio A. Torres-Netto, Leonard Kollros, Farhad Hafezi

    Background: As a key element of ocular accommodation, the inherent mechanical stiffness gradient and the gradient refractive index (GRIN) of the crystalline lens determine its deformability and optical functionality. Quantifying the GRIN profile and deformation characteristics in the lens has the potential to improve the diagnosis and follow-up of lenticular disorders and guide refractive interventions in the future. Methods: Here, we present a type of optical coherence elastography able to examine the mechanical characteristics of the human crystalline lens and the GRIN distribution in vivo. The concept is demonstrated in a case series of 12 persons through lens displacement and strain measurements in an age-mixed group of human subjects in response to an external (ambient pressure modulation) and an intrinsic (micro-fluctuations of accommodation) mechanical deformation stimulus. Results: Here we show an excellent agreement between the high-resolution strain map retrieved during steady-state micro-fluctuations and earlier reports on lens stiffness in the cortex and nucleus suggesting a 2.0 to 2.3 times stiffer cortex than the nucleus in young lenses and a 1.0 to 7.0 times stiffer nucleus than the cortex in the old lenses. Conclusions: Optical coherence tomography is suitable to quantify the internal stiffness and refractive index distribution of the crystalline lens in vivo and thus might contribute to reveal its inner working mechanism. Our methodology provides new routes for ophthalmic pre-surgical examinations and basic research.


  • Open Access

    Optomechanical assessment of photorefractive corneal cross-linking via optical coherence elastography

    by Matteo Frigelli, Philippe Büchler, Sabine Kling

    Purpose: Corneal cross-linking (CXL) has recently been used with promising results to positively affect corneal refractive power in the treatment of hyperopia and mild myopia. However, understanding and predicting the optomechanical changes induced by this procedure are challenging.Methods: We applied ambient pressure modulation based optical coherence elastography (OCE) to quantify the refractive and mechanical effects of patterned CXL and their relationship to energy delivered during the treatment on porcine corneas. Three different patterned treatments were performed, designed according to Zernike polynomial functions (circle, astigmatism, coma). In addition, three different irradiation protocols were analyzed: standard Dresden CXL (fluence of 5.4 J/cm2), accelerated CXL (fluence of 5.4 J/cm2), and high-fluence CXL (fluence of 16.2 J/cm2). The axial strain distribution in the stroma induced by ocular inflation (Δp = 30 mmHg) was quantified, maps of the anterior sagittal curvature were constructed and cylindrical refraction was assessed.Results: Thirty minutes after CXL, there was a statistically significant increase in axial strain amplitude (p < 0.050) and a reduction in sagittal curvature (p < 0.050) in the regions treated with all irradiation patterns compared to the non-irradiated ones. Thirty-6 hours later, the non-irradiated regions showed compressive strains, while the axial strain in the CXL-treated regions was close to zero, and the reduction in sagittal curvature observed 30 minutes after the treatment was maintained. The Dresden CXL and accelerated CXL produced comparable amounts of stiffening and refractive changes (p = 0.856), while high-fluence CXL produced the strongest response in terms of axial strain (6.9‰ ± 1.9‰) and refractive correction (3.4 ± 0.9 D). Tripling the energy administered during CXL resulted in a 2.4-fold increase in the resulting refractive correction.Conclusion: OCE showed that refractive changes and alterations in corneal biomechanics are directly related. A patient-specific selection of both, the administered UV fluence and the irradiation pattern during CXL is promising to allow customized photorefractive corrections in the future.


  • Open Access

    Localized Refractive Changes Induced by Symmetric and Progressive Asymmetric Intracorneal Ring Segments Assessed with a 3D Finite-Element Model

    by Gonzalo García de Oteyza, Juan Álvarez de Toledo, Rafael I. Barraquer, Sabine Kling

    To build a representative 3D finite element model (FEM) for intracorneal ring segment (ICRS) implantation and to investigate localized optical changes induced by different ICRS geometries, a hyperelastic shell FEM was developed to compare the effect of symmetric and progressive asymmetric ICRS designs in a generic healthy and asymmetric keratoconic (KC) cornea. The resulting deformed geometry was assessed in terms of average curvature via a biconic fit, sagittal curvature (K), and optical aberrations via Zernike polynomials. The sagittal curvature map showed a locally restricted flattening interior to the ring (Kmax −11 to −25 dpt) and, in the KC cornea, an additional local steepening on the opposite half of the cornea (Kmax up to +1.9 dpt). Considering the optical aberrations present in the model of the KC cornea, the progressive ICRS corrected vertical coma (−3.42 vs. −3.13 µm); horizontal coma (−0.67 vs. 0.36 µm); and defocus (2.90 vs. 2.75 µm), oblique trefoil (−0.54 vs. −0.08 µm), and oblique secondary astigmatism (0.48 vs. −0.09 µm) aberrations stronger than the symmetric ICRS. Customized ICRS designs inspired by the underlying KC phenotype have the potential to achieve more tailored refractive corrections, particularly in asymmetric keratoconus patterns.


  • Open Access

    A short screening tool identifying systemic barriers to distress screening in cancer care

    by Felice Simnacher, Anna Götz, Sabine Kling, Jan Ben Schulze, Roland von Känel, Sebastian Euler, Moritz Philipp Günther

    Introduction: International guidelines on cancer treatment recommend screening for early detection and treatment of distress. However, screening rates are insufficient. In the present study, a survey was developed to assess perceived systemic barriers to distress screening.Methods: A three‐step approach was used for the study. Based on qualitative content analysis of interviews and an expert panel, an initial survey with 53 questions on barriers to screening was designed. It was completed by 98 nurses in a large comprehensive cancer center in Switzerland. From this, a short version of the survey with 24 questions was derived using exploratory principal component analysis. This survey was completed by 150 nurses in four cancer centers in Switzerland. A confirmatory factor analysis was then performed on the shortened version, yielding a final set of 14 questions.Results: The initial set of 53 questions was reduced to a set of 14 validated questions retaining 53% of the original variance. These 14 questions allow for an assessment within 2–3 min that identifies relevant barriers to distress screening from the perspective of those responsible for implementation of distress screening. Across several hospitals in Switzerland, the timing of the first distress screening, lack of capacity, patient and staff overload, and refusal of distressed patients to be referred to support services emerged as major problems.Conclusion: The validated 14 questions on barriers to screening cancer patients for distress enable clinicians and hospital administrators to quickly identify relevant issues and take action to improve screening programs.


  • Intracorneal Ring Segment Implantation Results in Corneal Mechanical Strengthening Visualized With Optical Coherence Elastography

    by Emilio A. Torres-Netto, Farhad Hafezi, Sabine Kling

    PURPOSE: To quantify the mechanical impact of intracorneal ring segment (ICRS) implantation of different dimensions in an ex vivo eye model. METHODS: A total of 30 enucleated porcine eyes were assigned to ICRS implantation (thickness: 300 mu m, angle: 120 degrees, 210 degrees, or 325 degrees), tunnel creation only, or virgin control groups. For mechanical evaluation, each globe was mounted on a customized holder and intraocular pressure (IOP) was increased in steps of 0.5 mm Hg from 15 to 17 mm Hg, simulating physiologic diurnal IOP fluctuations. At each step, an optical coherence tomography volume scan was recorded. Deformations between subsequent scans and the locally induced axial strains were analyzed using a vector-based phase difference method. The effective E-modulus was derived from the overall induced strain as a measure of global mechanical impact. RESULTS: ICRS implantation increased the effective E-modulus from 146 and 163 kPa in virgin and tunnel-only eyes to 149, 192, and 330 kPa in eyes that received a 5-mm optical zone ICRS with 120 degrees, 210 degrees, and 325 degrees arc length, respectively; and to 209 kPa in a 6-mm optical zone ICRS with 325 degrees arc length. The most consistent effect was a shift toward positive strains in the posterior stroma by 0.1% to 0.46% (factor 1.15 to 2.15) after ICRS surgery. CONCLUSIONS: ICRS implantation reduces the overall tissue strain under the load of the IOP and provokes posterior tissue relaxation. This effect is more prominent the longer the arc length and the smaller the optical zone of the ICRS is. ICRS have not only a geometrical, but also a mechanical impact on corneal tissue. This behavior might have clinical implications when ICRS implantation is performed in biomechanically weakened keratoconic corneas.


  • Corneal Strain Induced by Intracorneal Ring Segment Implantation Visualized With Optical Coherence Elastography

    by Emilio A. Torres-Netto, Sabine Kling

    PURPOSE: To record the axial strain field in the cornea directly after creating a stromal tunnel and implanting an intracorneal ring segment (ICRS). METHODS: Freshly enucleated porcine eyes were obtained and assigned to either ICRS implantation, tunnel creation only, or virgin control groups. Immediately after manual tunnel creation and ICRS positioning, the entire eye globe was mounted on a customized holder and intraocular pressure (IOP) was adjusted to 15 mm Hg. Then, IOP was inreased to 20 mm Hg, in steps of 1 mm Hg. At each step, an optical coherence tomography volume scan was recorded. Displacements between subsequent scans were retrieved using a vector-based phase difference method. The induced corneal strain direction was determined by taking the axial gradient. In addition, corneal surface was detected and sagittal curvature maps computed. RESULTS: Corneal tissue presented a localized compressive strain in the direct vicinity of the stromal tunnel, which was independent of IOP change. The central and peripheral (exterior to the ICRS) cornea demonstrated compressive strains on IOP increase, and tensile strains on IOP decrease. ICRS implantation induced an annular-shaped tensile strain at its inner border, particularly during IOP increase. The compressive strains close to the tunnel remained after ICRS implantation. Corneal curvature changes were concentrated on regions where strain was induced. CONCLUSIONS: ICRS implantation induces localized strains in the regions subjected to refractive changes, suggesting that corneal strain and curvature are directly related. Studying corneal strain in response to surgical intervention may provide new insights on underlying working principles. [ J Refract Surg . 2022;38(3):210–216.]