Yaliang Yang
Yaliang Yang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Shen Chen
National Laboratory on Adaptive Optics, Chengdu, China
6 shared publicationsXian Yue
National Laboratory on Adaptive Optics, Chengdu, China
6 shared publicationsFan Yang
National Laboratory on Adaptive Optics, Chengdu, China
3 shared publicationsHao Dai
Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu, China
3 shared publicationsQixiang Huang
National Laboratory on Adaptive Optics, Chengdu, China
3 shared publicationsYudong Zhang
Key Laboratory of Adaptive Optics, Chinese Academy of Sciences, Chengdu, China
3 shared publications
Latest Publications
- Open Access
- 13 February 2026
- Published by Springer Nature in European Journal of Medical Research
- Vol. 31 (1)
Preliminary diagnosis of eye health via wavefront parameters based on statistical frequency distributions
Eye disease is a global health issue, and current diagnostic methods are complex, costly and more suitable for final diagnosis. In order to detect abnormal
- 13 February 2026
- Published by Springer Nature in European Journal of Medical Research
- Vol. 31 (1)
Open AccessPreliminary diagnosis of eye health via wavefront parameters based on statistical frequency distributions
Eye disease is a global health issue, and current diagnostic methods are complex, costly and more suitable for final diagnosis. In order to detect abnormal
- 21 July 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Tip-tilt phase measurement of probe using an optimized extended ptychographic iterative engine
- 21 July 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Tip-tilt phase measurement of probe using an optimized extended ptychographic iterative engine
- 12 August 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 183
Chromatic dispersion measurement of optical fiber using spectroscopic optical coherence tomography
- 12 August 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 183
Chromatic dispersion measurement of optical fiber using spectroscopic optical coherence tomography
- 28 June 2024
- Published by Springer Nature in International Ophthalmology
- Vol. 44 (1) , 1-13
Statistical optimal parameters obtained by using clinical human ocular aberrations for high-precision aberration measurement
Purpose Compared to Shack-Hartmann wavefront sensor (SHWS), the parameters of virtual SHWS (vSHWS) can be easily adjusted to obtain the optimal performance of aberration measurement. Its current optimal parameters are obtained with only a set of statistical aberrations and not statistically significant. Whether the above parameters are consistent with the statistical results of the optimal parameters corresponding to each set of aberrations, and which performance is better if not? The purpose of this study was to answer these questions. Methods The optimal parameters to reconstruct 624 sets of clinical ocular aberrations in the highest accuracy, including the numbers of sub-apertures (NSAs) and the expansion ratios (ERs) of electric field zero-padding, were determined sequentially in this work. By using wavefront-reconstruction accuracy as an evaluation index, the statistical optimal parameter configuration was selected from some possible configurations determined by the optimal NSAs and ERs. Results The statistical optimal parameters are consistent for normal and abnormal eyes. They are different from the optimal parameters obtained with a set of statistical aberrations from the same 624 sets of aberrations, and the performance using the former is better than that using the latter. The performance using a fixed set of statistical optimal parameters is even close to that using the respective optimal parameters corresponding to each set of aberrations. Conclusion The vSHWS configured with a fixed set of statistical optimal parameters can be used for high-precision aberration measurement of both normal and abnormal eyes. The statistical optimal parameters are more suitable for vSHWS than the parameters obtained with a set of statistical aberrations. These conclusions are significant for the designs of vSHWS and also SHWS.
- 28 June 2024
- Published by Springer Nature in International Ophthalmology
- Vol. 44 (1) , 1-13
Statistical optimal parameters obtained by using clinical human ocular aberrations for high-precision aberration measurement
Purpose Compared to Shack-Hartmann wavefront sensor (SHWS), the parameters of virtual SHWS (vSHWS) can be easily adjusted to obtain the optimal performance of aberration measurement. Its current optimal parameters are obtained with only a set of statistical aberrations and not statistically significant. Whether the above parameters are consistent with the statistical results of the optimal parameters corresponding to each set of aberrations, and which performance is better if not? The purpose of this study was to answer these questions. Methods The optimal parameters to reconstruct 624 sets of clinical ocular aberrations in the highest accuracy, including the numbers of sub-apertures (NSAs) and the expansion ratios (ERs) of electric field zero-padding, were determined sequentially in this work. By using wavefront-reconstruction accuracy as an evaluation index, the statistical optimal parameter configuration was selected from some possible configurations determined by the optimal NSAs and ERs. Results The statistical optimal parameters are consistent for normal and abnormal eyes. They are different from the optimal parameters obtained with a set of statistical aberrations from the same 624 sets of aberrations, and the performance using the former is better than that using the latter. The performance using a fixed set of statistical optimal parameters is even close to that using the respective optimal parameters corresponding to each set of aberrations. Conclusion The vSHWS configured with a fixed set of statistical optimal parameters can be used for high-precision aberration measurement of both normal and abnormal eyes. The statistical optimal parameters are more suitable for vSHWS than the parameters obtained with a set of statistical aberrations. These conclusions are significant for the designs of vSHWS and also SHWS.
- 3 February 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 91
Improving retinal OCT image classification accuracy using medical pre-training and sample replication methods
- 3 February 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 91
Improving retinal OCT image classification accuracy using medical pre-training and sample replication methods
- Open Access
- 11 March 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 16 (05)
Comparison of uniform resampling and nonuniform sampling direct-reconstruction methods in k-space for FD-OCT
The nonuniform distribution of interference spectrum in wavenumber k-space is a key issue to limit the imaging quality of Fourier-domain optical coherence tomography (FD-OCT). At present, the reconstruction quality at different depths among a variety of processing methods in k-space is still uncertain. Using simulated and experimental interference spectra at different depths, the effects of common six processing methods including uniform resampling (linear interpolation (LI), cubic spline interpolation (CSI), time-domain interpolation (TDI), and K-B window convolution) and nonuniform sampling direct-reconstruction (Lomb periodogram (LP) and nonuniform discrete Fourier transform (NDFT)) on the reconstruction quality of FD-OCT were quantitatively analyzed and compared in this work. The results obtained by using simulated and experimental data were coincident. From the experimental results, the averaged peak intensity, axial resolution, and signal-to-noise ratio (SNR) of NDFT at depth from 0.5 to 3.0[ ]mm were improved by about 1.9[ ]dB, 1.4 times, and 11.8[ ]dB, respectively, compared to the averaged indices of all the uniform resampling methods at all depths. Similarly, the improvements of the above three indices of LP were 2.0[ ]dB, 1.4 times, and 11.7[ ]dB, respectively. The analysis method and the results obtained in this work are helpful to select an appropriate processing method in k-space, so as to improve the imaging quality of FD-OCT.
- 11 March 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 16 (05)
Open AccessComparison of uniform resampling and nonuniform sampling direct-reconstruction methods in k-space for FD-OCT
The nonuniform distribution of interference spectrum in wavenumber k-space is a key issue to limit the imaging quality of Fourier-domain optical coherence tomography (FD-OCT). At present, the reconstruction quality at different depths among a variety of processing methods in k-space is still uncertain. Using simulated and experimental interference spectra at different depths, the effects of common six processing methods including uniform resampling (linear interpolation (LI), cubic spline interpolation (CSI), time-domain interpolation (TDI), and K-B window convolution) and nonuniform sampling direct-reconstruction (Lomb periodogram (LP) and nonuniform discrete Fourier transform (NDFT)) on the reconstruction quality of FD-OCT were quantitatively analyzed and compared in this work. The results obtained by using simulated and experimental data were coincident. From the experimental results, the averaged peak intensity, axial resolution, and signal-to-noise ratio (SNR) of NDFT at depth from 0.5 to 3.0[ ]mm were improved by about 1.9[ ]dB, 1.4 times, and 11.8[ ]dB, respectively, compared to the averaged indices of all the uniform resampling methods at all depths. Similarly, the improvements of the above three indices of LP were 2.0[ ]dB, 1.4 times, and 11.7[ ]dB, respectively. The analysis method and the results obtained in this work are helpful to select an appropriate processing method in k-space, so as to improve the imaging quality of FD-OCT.
- Open Access
- 1 March 2023
- Published by Tsinghua University Press in Photonic Sensors
- Vol. 13 (3) , 1-15
Accounting for Polychromatic Light in Virtual Shack-Hartmann Wavefront Sensing
Virtual Shack-Hartmann wavefront sensing (vSHWS) has some significant advantages and is promising for aberration measurement in the field of biomedical optical imaging. The illumination sources used in vSHWS are almost broadband, but are treated as monochromatic sources (only using center wavelength) in current data processing, which may cause errors. This work proposed a data processing method to take into account the multiple wavelengths of the broadband spectrum, named multiple-wavelength centroid-weighting method. Its feasibility was demonstrated through a series of simulations. A wavefront generated with a set of statistical human ocular aberrations was used as the target wavefront to evaluate the performance of the proposed and current methods. The results showed that their performance was very close when used for the symmetrical, but the wavefront error of the proposed method was much smaller than that of the current method when used for the asymmetrical spectrum, especially for the broader spectrum. These results were also validated by using 20 sets of clinical human ocular aberrations including normal and diseased eyes. The proposed method and the obtained conclusions have important implications for the application of vSHWS.
- 1 March 2023
- Published by Tsinghua University Press in Photonic Sensors
- Vol. 13 (3) , 1-15
Open AccessAccounting for Polychromatic Light in Virtual Shack-Hartmann Wavefront Sensing
Virtual Shack-Hartmann wavefront sensing (vSHWS) has some significant advantages and is promising for aberration measurement in the field of biomedical optical imaging. The illumination sources used in vSHWS are almost broadband, but are treated as monochromatic sources (only using center wavelength) in current data processing, which may cause errors. This work proposed a data processing method to take into account the multiple wavelengths of the broadband spectrum, named multiple-wavelength centroid-weighting method. Its feasibility was demonstrated through a series of simulations. A wavefront generated with a set of statistical human ocular aberrations was used as the target wavefront to evaluate the performance of the proposed and current methods. The results showed that their performance was very close when used for the symmetrical, but the wavefront error of the proposed method was much smaller than that of the current method when used for the asymmetrical spectrum, especially for the broader spectrum. These results were also validated by using 20 sets of clinical human ocular aberrations including normal and diseased eyes. The proposed method and the obtained conclusions have important implications for the application of vSHWS.
- Open Access
Optimization of Virtual Shack-Hartmann Wavefront Sensing
Virtual Shack–Hartmann wavefront sensing (vSHWS) can flexibly adjust parameters to meet different requirements without changing the system, and it is a promising means for aberration measurement. However, how to optimize its parameters to achieve the best performance is rarely discussed. In this work, the data processing procedure and methods of vSHWS were demonstrated by using a set of normal human ocular aberrations as an example. The shapes (round and square) of a virtual lenslet, the zero-padding of the sub-aperture electric field, sub-aperture number, as well as the sequences (before and after diffraction calculation), algorithms, and interval of data interpolation, were analyzed to find the optimal configuration. The effect of the above optimizations on its anti-noise performance was also studied. The Zernike coefficient errors and the root mean square of the wavefront error between the reconstructed and preset wavefronts were used for performance evaluation. The performance of the optimized vSHWS could be significantly improved compared to that of a non-optimized one, which was also verified with 20 sets of clinical human ocular aberrations. This work makes the vSHWS’s implementation clearer, and the optimization methods and the obtained results are of great significance for its applications.
Open AccessOptimization of Virtual Shack-Hartmann Wavefront Sensing
Virtual Shack–Hartmann wavefront sensing (vSHWS) can flexibly adjust parameters to meet different requirements without changing the system, and it is a promising means for aberration measurement. However, how to optimize its parameters to achieve the best performance is rarely discussed. In this work, the data processing procedure and methods of vSHWS were demonstrated by using a set of normal human ocular aberrations as an example. The shapes (round and square) of a virtual lenslet, the zero-padding of the sub-aperture electric field, sub-aperture number, as well as the sequences (before and after diffraction calculation), algorithms, and interval of data interpolation, were analyzed to find the optimal configuration. The effect of the above optimizations on its anti-noise performance was also studied. The Zernike coefficient errors and the root mean square of the wavefront error between the reconstructed and preset wavefronts were used for performance evaluation. The performance of the optimized vSHWS could be significantly improved compared to that of a non-optimized one, which was also verified with 20 sets of clinical human ocular aberrations. This work makes the vSHWS’s implementation clearer, and the optimization methods and the obtained results are of great significance for its applications.
- 27 December 2019
- Published by IOP Publishing in Journal of Optics
- Vol. 22 (2) , 025301
A method to correct longitudinal chromatic aberration between imaging and beacon beams of ocular adaptive optics imaging system
A method to correct the longitudinal chromatic aberration (LCA) between the imaging beam (IB) and beacon beam of ocular adaptive optics (AO) imaging system is presented, by inserting trial spherical lens, i.e. chromatic aberration corrector (CAC), on the imaging light path. The LCA of the optical system, and the quantitative relation between the CAC diopter and the IB focus shift, are determined experimentally. Then the CAC diopter required for human eye imaging can be determined by using above results combined the existing ocular LCA data. The feasibility of this method was proved by imaging results of different samples with a model eye. Finally, the method was demonstrated to significantly improve the imaging effect in in vivo retinal AO optical coherence tomography imaging of volunteers. It does not require additional burdens, is easy-to-use and suitable for various ocular AO imaging systems.
- 27 December 2019
- Published by IOP Publishing in Journal of Optics
- Vol. 22 (2) , 025301
A method to correct longitudinal chromatic aberration between imaging and beacon beams of ocular adaptive optics imaging system
A method to correct the longitudinal chromatic aberration (LCA) between the imaging beam (IB) and beacon beam of ocular adaptive optics (AO) imaging system is presented, by inserting trial spherical lens, i.e. chromatic aberration corrector (CAC), on the imaging light path. The LCA of the optical system, and the quantitative relation between the CAC diopter and the IB focus shift, are determined experimentally. Then the CAC diopter required for human eye imaging can be determined by using above results combined the existing ocular LCA data. The feasibility of this method was proved by imaging results of different samples with a model eye. Finally, the method was demonstrated to significantly improve the imaging effect in in vivo retinal AO optical coherence tomography imaging of volunteers. It does not require additional burdens, is easy-to-use and suitable for various ocular AO imaging systems.