Yi Chen
Research Subjects
Yi Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- David Juny Yoon
Institute for Aerospace Studies, University of Toronto, Toronto, ON, Canada
1 shared publication - Gaoming Li
Univ. of Michigan (United States)
1 shared publication Haijun Li
University of Michigan, Ann Arbor, USA
1 shared publication- Heethesh Vhavle
Aeva Inc., Mountain View, CA, USA
1 shared publication James Reuther
Aeva Inc., Mountain View, CA, USA
1 shared publicationJeff Sterniak
Robert Bosch LLC, Farmington Hills, MI 48331
1 shared publication
Latest Publications
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (9) , 9088-9095
Towards Fast Correspondence-Free Odometry Using Multiple FMCW Lidars
3D FMCW lidars return relative velocity measurements via the Doppler effect, which provides a new form of information for motion estimation. In our prior work, we proposed an odometry method that avoids the conventional ICP-based approach and uses the Doppler velocity measurements in a correspondence-free way. The caveat is that the angular velocity is not observable from the Doppler measurements of a single lidar, for which we compensate by using a gyroscope. This paper is an extension of our prior work that furthers our experiments using multiple FMCW lidars. We first present better odometry performance using an improved calibration for the Doppler measurement bias and noise, and additionally show how the Expectation-Maximization algorithm can be applied to calibrate without the groundtruth trajectory. We then show improved results on our correspondence-free odometry when given access to multiple lidars and gyroscopes. We also present preliminary results without gyroscope sensors to validate our prior algebraic study that the 6-degrees-of-freedom motion is still observable with multiple lidars. While we show that odometry performance without gyroscopes is not yet as accurate, we compare against simulated measurements to motivate the potential of Doppler-only lidar odometry as a future research direction.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (9) , 9088-9095
Towards Fast Correspondence-Free Odometry Using Multiple FMCW Lidars
3D FMCW lidars return relative velocity measurements via the Doppler effect, which provides a new form of information for motion estimation. In our prior work, we proposed an odometry method that avoids the conventional ICP-based approach and uses the Doppler velocity measurements in a correspondence-free way. The caveat is that the angular velocity is not observable from the Doppler measurements of a single lidar, for which we compensate by using a gyroscope. This paper is an extension of our prior work that furthers our experiments using multiple FMCW lidars. We first present better odometry performance using an improved calibration for the Doppler measurement bias and noise, and additionally show how the Expectation-Maximization algorithm can be applied to calibrate without the groundtruth trajectory. We then show improved results on our correspondence-free odometry when given access to multiple lidars and gyroscopes. We also present preliminary results without gyroscope sensors to validate our prior algebraic study that the 6-degrees-of-freedom motion is still observable with multiple lidars. While we show that odometry performance without gyroscopes is not yet as accurate, we compare against simulated measurements to motivate the potential of Doppler-only lidar odometry as a future research direction.
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (2) , 661-672
Motion Estimation for a Compact Electrostatic Microscanner via Shared Driving and Sensing Electrodes in Endomicroscopy
In this article, we present a method to estimate high-frequency rotary motion of a highly compact electrostatic microscanner using the same electrodes for both actuation and sensing. The accuracy of estimated rotary motion is critical for reducing blur and distortion in image reconstruction applications with the microscanner given its changing dynamics due to perturbations such as temperature. To overcome the limitation that no dedicated sensing electrodes are available in the proposed applications due to size constraints, the method adopts electromechanical amplitude modulation to separate motion signal from parasitic capacitance feedthrough, and a novel nonlinear measurement model is derived to characterize the relationship between large out-of-plane angular motion and circuit output. To estimate motion, an extended Kalman filter and an unscented Kalman filter are implemented, incorporating a process model based on the microscanner's parametric resonant dynamics and the measurement model. Experimental results show that compared to estimation without using the measurement model, our method can improve the rotary motion estimation accuracy of the microscanner significantly, with a reduction of root-mean-square error (RMSE) in phase shift of 86.1%, and a reduction of RMSE in angular position error of 78.5%.
- 12 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 25 (2) , 661-672
Motion Estimation for a Compact Electrostatic Microscanner via Shared Driving and Sensing Electrodes in Endomicroscopy
In this article, we present a method to estimate high-frequency rotary motion of a highly compact electrostatic microscanner using the same electrodes for both actuation and sensing. The accuracy of estimated rotary motion is critical for reducing blur and distortion in image reconstruction applications with the microscanner given its changing dynamics due to perturbations such as temperature. To overcome the limitation that no dedicated sensing electrodes are available in the proposed applications due to size constraints, the method adopts electromechanical amplitude modulation to separate motion signal from parasitic capacitance feedthrough, and a novel nonlinear measurement model is derived to characterize the relationship between large out-of-plane angular motion and circuit output. To estimate motion, an extended Kalman filter and an unscented Kalman filter are implemented, incorporating a process model based on the microscanner's parametric resonant dynamics and the measurement model. Experimental results show that compared to estimation without using the measurement model, our method can improve the rotary motion estimation accuracy of the microscanner significantly, with a reduction of root-mean-square error (RMSE) in phase shift of 86.1%, and a reduction of RMSE in angular position error of 78.5%.
- 21 July 2015
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 137 (12) , 121508
Lean HCCI/Rich SACI Gasoline Combustion Cycling and Three-Way Catalyst for Fuel Efficiency and NOx Reduction
Multimode combustion (MMC) concepts using homogeneous charge compression ignition (HCCI) gasoline combustion at low loads and spark assisted compression ignition (SACI) gasoline combustion at medium loads have the potential for improved fuel efficiency relative to spark ignition (SI) gasoline combustion. Two MMC concepts are compared in this paper with respect to fuel efficiency and tailpipe NOx emissions. The first concept uses stoichiometric HCCI and SACI to allow standard three-way catalyst (TWC) operation. The second concept also uses HCCI and SACI, but cycles between lean and rich combustion and uses a TWC with increased oxygen storage capacity (OSC) for potentially even greater fuel efficiency improvement. This paper performs a preliminary comparison of the two MMC concepts by analyzing two scenarios: (1) cycling between stoichiometric HCCI at 2 bar BMEP (brake mean effective pressure) and stoichiometric SACI at 3 bar BMEP, and (2) cycling between lean HCCI at 2 bar BMEP and rich SACI at 3 bar BMEP. The effects of excess oxygen ratio during HCCI operation and the frequency of oxygen depletion events on TWC performance and fuel efficiency are investigated. Results show that MMC lean/rich cycling can achieve better fuel efficiency than stoichiometric HCCI/SACI cycling. NOx emissions are moderately higher, but may still be low enough to meet current and future emission regulations.
- 21 July 2015
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 137 (12) , 121508
Lean HCCI/Rich SACI Gasoline Combustion Cycling and Three-Way Catalyst for Fuel Efficiency and NOx Reduction
Multimode combustion (MMC) concepts using homogeneous charge compression ignition (HCCI) gasoline combustion at low loads and spark assisted compression ignition (SACI) gasoline combustion at medium loads have the potential for improved fuel efficiency relative to spark ignition (SI) gasoline combustion. Two MMC concepts are compared in this paper with respect to fuel efficiency and tailpipe NOx emissions. The first concept uses stoichiometric HCCI and SACI to allow standard three-way catalyst (TWC) operation. The second concept also uses HCCI and SACI, but cycles between lean and rich combustion and uses a TWC with increased oxygen storage capacity (OSC) for potentially even greater fuel efficiency improvement. This paper performs a preliminary comparison of the two MMC concepts by analyzing two scenarios: (1) cycling between stoichiometric HCCI at 2 bar BMEP (brake mean effective pressure) and stoichiometric SACI at 3 bar BMEP, and (2) cycling between lean HCCI at 2 bar BMEP and rich SACI at 3 bar BMEP. The effects of excess oxygen ratio during HCCI operation and the frequency of oxygen depletion events on TWC performance and fuel efficiency are investigated. Results show that MMC lean/rich cycling can achieve better fuel efficiency than stoichiometric HCCI/SACI cycling. NOx emissions are moderately higher, but may still be low enough to meet current and future emission regulations.