Taeyong Kim

Taeyong Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Taeyong Kim has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Passivating Contact Properties based on SiOX/poly-Si Thin Film Deposition Process for High-efficiency TOPCon Solar Cells

    by Sungheon Kim, Taeyong Kim, Sungjin Jeong, Yewon Cha, Hongrae Kim, Somin Park, Minkyu Ju, Junsin Yi


  • Open Access

    Replacement Strategy of Insulators Established by Probability of Failure

    by Simpy Sanyal, Taeyong Kim, Chang-Sung Seok, Junsin Yi, Ja-Bin Koo, Ju-Am Son, In-Hyuk Choi

    Insulators comprise only 5% of the capital cost of transmission lines; they are accountable for 70% of line interruptions and 50% of maintenance costs of transmission lines. Major transmission lines situated in different parts of the world were mostly all constructed 30 years ago. These lines have either completed or are approaching the active life at 30 years. It is not possible to replace all insulators at a time in any utility. From a standpoint of consistency, it is quite important to locate insulators that require replacement prior to the occurrence of failure. Recalling these issues, a replacement strategy was modeled on insulator samples, operated at 154 kV, mechanical and electrical rating (M+E) 25,000 lbs and within the 10–50 years (Y) age group, collected in bulk for laboratory evaluation, based on the probability of mechanical failure (P(F)) of insulators. For conducting these studies, tensile load test such as combined electrical and mechanical failing load test was performed on selected 30 new and aged porcelain insulator samples from bulk to access recent condition. It was observed that insulators under service for 50 years manifested a decrease of 89.3% in quality factor (K), as compared to insulators within 10 years of service. A micro-structural study was carried out by using an optical microscope (OM) and a scanning electron microscope (SEM) for the further confirmation of previous evaluations. P(F) was derived by implementing Weibull distribution on the experimental observations. It was observed that insulators with an age of 50 years depicted a 2.7% increase in P(F), as compared to insulators with an age of 10 years. This article discussed a strategy for accessing the recent condition of new, aged bulk samples and the criteria of the replacement of the insulator string based on P(F).


  • Open Access

    Analysis of Thermal Sensitivity by High Voltage Insulator Materials

    by Taeyong Kim, Simpy Sanyal, Ja-Bin Koo, Ju-Am Son, In-Hyuk Choi, Junsin Yi

    Insulators serve bi-fold objectives of holding the conductor and electrical segregation from the grounded structure. For reliable operation of utility, electrical and mechanical strength of insulators are equally significant. The mechanical load is governed by weight of conductor, tension and environmental conditions like wind, snow, rain and typhoons etc. However, electrical strength is determined by survival of insulators against system voltage and transient over-voltages. A simulated power arc test was conducted on porcelain insulator samples by passing 72 kA/cycle surge current to evaluate for sudden lightning conditions after conducting insulation measurement of insulator samples. All cristobalite samples broke during power arc test. Power arc test revealed the thermal expansion coefficient of cristobalite samples were1.6 times higher as compared to alumina samples. Followed to arc test, X-Ray Diffraction (XRD), and Scanning Electron Microscope (SEM) were performed on insulator samples to evaluate consequences of power arc test on both cristobalite and alumina insulators. XRD reveals doubling of peak of cristobalite phase of fractured cristobalite insulators due to flow of high surge current through insulator body. X-Ray Fluorescence (XRF) was performed to investigate the elemental composition of Alumina and cristobalite porcelain insulators. Results of XRF show 5% increased Al2O3 in alumina samples as compared to cristobalite samples. Finally SEM was carried to study microstructure of samples before and after power arc test. SEM analysis depicts the maximum pore size in cristobalite porcelain insulators were increased to 200 lm unlike alumina insulators. This article outline layout of research strategy to study behavior of alumina and cristobalite porcelain insulators.


  • Open Access

    Failure Trends of High-Voltage Porcelain Insulators Depending on the Constituents of the Porcelain

    by Simpy Sanyal, Taeyong Kim, Junsin Yi, Ja-Bin Koo, Ju-Am Son, In-Hyuk Choi

    The aging of porcelain insulators is responsible for the failure of power utilities. Porcelain insulators from different places in South Korea, possessing various aging times and years of installation, have been investigated to carry out lifetime statistics. These samples have a mass of 36,000 lbs and are operated at 154 kV. X-ray fluorescence (XRF) and scanning electron microscopy (SEM) were performed on the porcelain bodies of the samples collected. XRF and SEM revealed trends in the weight percentage of SiO2, Al2O3, and Fe2O3 in the porcelain bodies of the collected samples. The SiO2 and Fe2O3 weight percentage reduced to 8.93% and 73.17%, respectively, in sample C compared to A. However, the Al2O3 weight percentage increased to 16.23% in sample C compared to sample A. This change in weight percentage of SiO2, Fe2O3, and Al2O3 contributed toward enhancing the mechanical and electrical properties of the insulators. Mechanical load tests with electrical voltage (M&E), thermal and mechanical load tests (T&M), and hardness tests (HRB) were performed to evaluate these characteristics. Experiments revealed an increase of 90.9% in the inequality factor (K) in sample C compared to A. The impact of constituents of porcelain on the lifetime expectancy of a porcelain insulator was reported by implementing statistical strategies, such as the Weibull distribution.


  • Open Access

    Mechanism of Corrosion in Porcelain Insulators and Its Effect on the Lifetime

    by Taeyong Kim, Youn-Jung Lee, Simpy Sanyal, Jung-Wook Woo, In-Hyuk Choi, Junsin Yi

    Porcelain insulators should be exchanged periodically, but their lifetime is not clearly defined. One factor that affects service life is corrosion occurring at the pin and cap—each of which is made of iron with a zinc coating. A number of porcelain insulators used for different lengths of time in different locations are gathered, and the corrosion mechanisms of the cap and pin are investigated. The corrosion mechanism of the cap is mainly galvanic corrosion while that of the pin is primarily electrolytic and crevice corrosion as well as galvanic corrosion. Although time is an important factor in corrosion, it is found that corrosion is more influenced by geographical factors. Since the amount of acid rain and sea salt—each of which causes rapid rusting—is dependent on geographical factors, the location of where porcelain insulators are installed should be considered when predicting their lifetime. Theoretically, if there is only galvanic corrosion occurring, the expected lifetime is 56 years in an industrial area when the zinc coating has a thickness of 75 µm. Previous articles dealing with aging have predicted the maximum lifetime of porcelain insulators used in Korea to be approximately 30 years. To prolong the lifetime of porcelain insulators, further study is required in which the use of zinc alternatives, or waterproof coatings (in addition to the zinc coating), could be examined.


  • Open Access

    Analysis of Long-Term Deterioration Characteristics of High Voltage Insulators

    by Taeyong Kim, Simpy Sanyal, Ja-Bin Koo, Ju-Am Son, In-Hyuk Choi, Junsin Yi

    The deterioration of the cement that bonds the cap, pin, and porcelain shell of the porcelain insulators can be observed by three-dimensional computed tomography (3D-CT), a non-destructive test. When porcelain insulators are used for a long duration, the size of the pores existing in the cement increase as the cement expands due to the alkali-silica reaction (ASR). It is possible to visually confirm the corrosion of caps and pins. The degree of corrosion is divided into four noticeable stages (I–IV), and deterioration of cement includes one of the four stages of corrosion. The standard time of replacement of insulator vs. continued use is presented. As a result of X-ray diffraction (XRD) analysis, Fe is oxidized to Fe2O3 at 36, 43, 54, and 70 degrees. The corrosion in cement is caused by factors including the value of pH, oxygen content, and temperature. For the caps and pins, although a zinc coating is applied to prevent the corrosion of iron, corrosion of zinc is caused by substances present in the external environment. When the zinc coating begins to corrode, the corrosion of the Fe component of the cap and pin accelerates, causing mechanical/electrical problems.


  • Open Access

    Analysis of Cement Deterioration in Outdoor High-Voltage Insulator

    by Taeyong Kim, Simpy Sanyal, Ja-Bin Koo, Ju-Am Son, In-Hyuk Choi, Junsin Yi

    Suspension type porcelain insulators used in overhead transmission lines comprise metal, ceramic, and cement. The deterioration of cement can lead to mechanical separation. For the degradation analysis, varied sizes of pores ranging from a few µm (capillary pores) to tens to hundreds of mm (detectable by naked eyes) were considered. Cracks that were hard to view with naked eyes were identified by staining with a fuchsine solution. The hydrogen ion concentration and pH value indicate the extent to which the cement is deteriorated. The longer the cement is used, the lower its pH value. High mechanical strength is considered an important advantage of porcelain insulators, and it may decline, if the cement is used for a longer period of time. Water ingress may also occur, resulting in expansion, due to the rehydration of the cement. The process and mechanism of expansion of cement, due to infiltration of water were described. As a method of analysis, a universal indicator was employed to evaluate the pH changes in cement. It was observed that the pH value was 12–13 for new products. However, for products that were used for 52 years, the pH value was under 7, which indicated an acidic tendency, due to deterioration.