SNSharayu Nimonkar

Sharayu Nimonkar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sharayu Nimonkar has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Pranali Nimonkar

    Govt Med Coll & Hosp, Trauma Care Ctr, Nagpur, India

    12 shared publications
  • Surekha Godbole

    Department of Prosthodontics and Crown and Bridge, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Deemed to be University, Wardha, Maharashtra, India

    12 shared publications
  • Vikram Belkhode

    Sharad Pawar Dent Coll & Hosp, Datta Meghe Inst Higher Educ & Res, Prosthodont, Wardha, India

    10 shared publications
  • Sweta Pisulkar

    Sharad Pawar Dent Coll & Hosp, Datta Meghe Inst Higher Educ & Res, Prosthodont, Wardha, India

    8 shared publications
  • Seema Sathe

    Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Medical Sciences, Wardha, Maharashtra, India

    6 shared publications
  • Vikram Belkhode

    Department of Prosthodontics and Crown & Bridge, Sharad Pawar Dental College, Datta Meghe Institute of Higher Education and Research, 202, SPDC building, DMIHER, Sawangi (Meghe), Wardha, Maharashtra, 442001, India, 91 7057088288

    5 shared publications

Latest Publications

  • Open Access

    Assessment of the knowledge and awareness among general medical practitioners toward dental intervention in diagnosing and treating obstructive sleep apnea: a cross-sectional study

    by Arti Agrawal, Sharayu Nimonkar, Vikram Belkhode, Surekha Godbole, Namita Zilpilwar, Raghav Munje, Pranali Nimonkar

    Obstructive Sleep Apnea (OSA), one of the most common sleep disorders, is associated with a large amount of morbidity to both the heart and metabolic function. Continuous Positive Airway Pressure (CPAP) remains the gold standard treatment for patients with OSA. In contrast, Dental treatments such as Mandibular Advancement Devices (MADs) are considered well-established alternatives for certain patients. Since General Practitioners (GPs) often initiate the diagnostic and therapeutic management of these patients, the extent of their understanding of dental and craniofacial management options remains unclear. An electronic cross-sectional survey was conducted among licensed Medical Practitioners from both the Allopathic and AYUSH (Ayurveda, Yoga & Naturopathy, Unani, Siddha, Sowa-Rigpa, and Homeopathy) streams. A 15-question questionnaire was used to assess four domains: (1) Aetiology, (2) Diagnosis, (3) Treatment, and (4) Referral Practices. Responses ("Agree," "Disagree," "Not aware") were recorded and converted to a binary system for analysis, where Agree equals 1 and Disagree/Not aware equals 0. Descriptive statistics and Chi-square tests will help analyse the variation between domains at a statistically significant level (p < 0.05). Diagnostic awareness was moderate, with 57.6% identifying polysomnography (PSG) as the gold standard test. There was a deficiency in knowledge on the available treatment options: only half of them recognized MADs as efficient. The composite scoring provided a moderate knowledge score (6.72 ± 3.08) and significantly lower mean awareness score (1.79 ± 0.73). There was great heterogeneity between domains (χ2 = 127.31, df = 36, p = 0.0001) as familiarity with dental and craniofacial and referral-related aspects of OSA care was inconsistent. GPs showed a greater level of awareness of general diagnostic concepts compared to craniofacial risk factors, oral appliance therapy, or interdisciplinary referral pathways. Specific educational programs and organized medical-dental partnership models should be established in order to enhance integrated management of OSA.


  • Open Access

    Correlation between insertion torque value and bone density in D3 and D4 bone following photobiomodulation: a randomised interventional study

    by Ashika Singhania, Anjali Bhoyar Borle, Surekha Godbole, Sharayu Nimonkar, Sheetal Khubchandani

    This study aimed to assess the correlation between insertion torque values and bone density measured via CBCT in D3 and D4 bone types after photobiomodulat

  • Open Access

    In Vitro Comparison of the Dimensional Accuracy of Implant Impressions Using Custom Acrylic Trays and Prefabricated Self-Perforating Trays: Protocol for a Comparative Evaluation Study

    by Arti Agrawal, Sharayu Nimonkar, Surekha Godbole, Rushabh Parakh, Vikram Belkhode, Namita Zilpilwar

    Background: The accurate transfer of implant positions from the patient’s mouth to the laboratory is crucial for the successful fabrication of prostheses in implant-based prosthodontics. Making an implant impression is a crucial part of this procedure as it replicates the intraoral implant position and transfers it to the cast to be used in the laboratory for fabricating a passive fit prosthesis. The purpose of this study is to compare and assess the accuracy of implant impressions made with prefabricated self-perforating trays and custom acrylic trays. Objective: The primary objective is to compare the dimensional accuracy of implant impressions made using custom acrylic trays versus prefabricated self-perforating trays in an in vitro setting. The secondary objective is to determine whether the impressions made with prefabricated self-perforating trays achieve clinically acceptable accuracy. Methods: A partially edentulous mandibular model with implants placed at the second premolar and first molar region will function as a master model. Impressions will be made using the custom acrylic tray and prefabricated self-perforating implant impression tray. The cast obtained will be scanned, and an STL file will be generated to evaluate the accuracy of implant positions using HyperMesh software. Statistical analysis will be done with IBM SPSS Statistics at a 95% CI and 80% power. Results: The study aims to evaluate whether there is a statistically significant difference in the accuracy of implant casts obtained using prefabricated self-perforating trays versus custom acrylic trays. As of July 2025, the models have been prepared for further analysis. It is projected that data collection will be completed in May 2026, with results to be published in early 2027. Conclusions: For the success of implant dentistry, the precise fit of the final prosthesis has become a necessity. A mismatched framework may overload the implant, endangering its durability. To achieve a precise fit of the implant framework, a precise definitive cast is necessary, which depends on several factors, one of them being the implant impression tray selection. Traditionally, custom acrylic trays have been used. However, they are impractical to use in routine clinical practice due to certain disadvantages. A newer range of trays for the open tray impression technique is being marketed, and one would be able to reduce the additional expense and laboratory time associated with using custom acrylic trays by using this newer variety of self-perforating implant impression tray.

  • Open Access

    Efficacy of Artificial Intelligence–Assisted Appliances in the Selection of Tooth Shade: Protocol for an Observational Study

    by Namita Zilpilwar, Sharayu Nimonkar, Surekha Godbole, Vikram Belkhode

    Background: Accurate shade matching in dentistry is crucial for achieving aesthetic outcomes, with increasing patient expectations driving advancements in shade selection technologies. Color perception is influenced by multiple factors such as incident light, reflection, absorption, observer variability, and environmental conditions. The evolution of shade-matching tools now includes digital and artificial intelligence (Al)-assisted appliances aimed at improving accuracy and ease of use. Objective: This study aims to compare and evaluate the efficacy of AI-assisted appliances, namely, smartphone cameras, digital single-lens reflex (DSLR) cameras, and intraoral scanners in selecting tooth shades in clinical practice. Methods: This observational study conducted at the Department of Prosthodontics and Crown & Bridge aims to evaluate shade selection methods in 221 participants recruited from the outpatient department based on specific inclusion and exclusion criteria, including age, oral health status, and informed consent. Three devices will be used for shade selection: a smartphone camera (iPhone 12, iOS 12.5.2) for quick, noninvasive, and accessible image capture; a DSLR camera (Canon EOS 200D) to obtain high-resolution images under standardized lighting for enhanced color accuracy; and an intraoral scanner (CEREC Primescan, Dentsply Sirona) offering precise 3D mapping and digital shade analysis. This multidevice approach allows for a comparative evaluation of conventional and advanced digital tools in clinical shade matching. The primary objective is to assess the effectiveness of commonly available digital teeth in accurately selecting tooth shades. Our study anticipates the following outcomes: validation of smartphone cameras as simple, economical, and efficient tools for basic shade matching; demonstration of DSLR cameras’ superiority in resolution and lighting control for improved accuracy; and confirmation of intraoral scanners as precise, customizable devices that offer a high level of digital integration. Statistical analyses will include sensitivity, specificity, and subgroup evaluations to compare the performance of each device. The findings are expected to show that both DSLR and smartphone cameras can match the effectiveness of intraoral scanners, offering viable alternatives for clinical use. Results: This study was intramurally funded in December 2024. Data collection is scheduled to commence following the publication of this study protocol. As of submission, no participants have been recruited, and data analysis is yet to begin. Results are expected to be completed and published in early January 2026. Conclusions: This study aims to establish a standard protocol for the use of Al-assisted, easily accessible tools such as smartphones and DSLRs for dental shade selection. These devices, being user-friendly and nontechnical, could democratize the process of shade matching, benefiting both clinicians and patients by improving restoration outcomes while reducing costs and complexity. Our results will contribute to the growing body of digital dentistry literature and support the integration of practical Al tools in everyday clinical practice. Trial Registration: Clinical Trials Registry-India CTRI/2024/07/070002; https://tinyurl.com/4pt5eutb International Registered Report Identifier (IRRID): PRR1-10.2196/68160


  • Open Access

    Efficacy of Artificial Intelligence–Assisted Appliances in the Selection of Tooth Shade: Protocol for an Observational Study (Preprint)

    by Namita Zilpilwar, Sharayu Nimonkar, Surekha Godbole, Vikram Belkhode

    BACKGROUND Accurate shade matching in dentistry is crucial for achieving aesthetic outcomes, with increasing patient expectations driving advancements in shade selection technologies. Color perception is influenced by multiple factors such as incident light, reflection, absorption, observer variability, and environmental conditions. The evolution of shade-matching tools now includes digital and artificial intelligence (Al)-assisted appliances aimed at improving accuracy and ease of use. OBJECTIVE This study aims to compare and evaluate the efficacy of AI-assisted appliances, namely, smartphone cameras, digital single-lens reflex (DSLR) cameras, and intraoral scanners in selecting tooth shades in clinical practice. METHODS This observational study conducted at the Department of Prosthodontics and Crown & Bridge aims to evaluate shade selection methods in 221 participants recruited from the outpatient department based on specific inclusion and exclusion criteria, including age, oral health status, and informed consent. Three devices will be used for shade selection: a smartphone camera (iPhone 12, iOS 12.5.2) for quick, noninvasive, and accessible image capture; a DSLR camera (Canon EOS 200D) to obtain high-resolution images under standardized lighting for enhanced color accuracy; and an intraoral scanner (CEREC Primescan, Dentsply Sirona) offering precise 3D mapping and digital shade analysis. This multidevice approach allows for a comparative evaluation of conventional and advanced digital tools in clinical shade matching. The primary objective is to assess the effectiveness of commonly available digital teeth in accurately selecting tooth shades. Our study anticipates the following outcomes: validation of smartphone cameras as simple, economical, and efficient tools for basic shade matching; demonstration of DSLR cameras’ superiority in resolution and lighting control for improved accuracy; and confirmation of intraoral scanners as precise, customizable devices that offer a high level of digital integration. Statistical analyses will include sensitivity, specificity, and subgroup evaluations to compare the performance of each device. The findings are expected to show that both DSLR and smartphone cameras can match the effectiveness of intraoral scanners, offering viable alternatives for clinical use. RESULTS This study was intramurally funded in December 2024. Data collection is scheduled to commence following the publication of this study protocol. As of submission, no participants have been recruited, and data analysis is yet to begin. Results are expected to be completed and published in early January 2026. CONCLUSIONS This study aims to establish a standard protocol for the use of Al-assisted, easily accessible tools such as smartphones and DSLRs for dental shade selection. These devices, being user-friendly and nontechnical, could democratize the process of shade matching, benefiting both clinicians and patients by improving restoration outcomes while reducing costs and complexity. Our results will contribute to the growing body of digital dentistry literature and support the integration of practical Al tools in everyday clinical practice. CLINICALTRIAL Clinical Trials Registry-India CTRI/2024/07/070002; https://tinyurl.com/4pt5eutb INTERNATIONAL REGISTERED REPORT PRR1-10.2196/68160


  • Open Access

    Assessing the Prevalence and Characteristics of Dental Anxiety among Patients Reporting to Dental Operatory

    by Pooja Raut, Surekha Godbole, Sharayu Vinod Nimonkar, Vikram Murlidhar Belkhode, Akansha Vilas Bansod, Sweta Kale Pisulkar

    Background: Approximately 36% of the population is stated to be affected by dental anxiety or dental fear, with a further 12% suffering from extreme dental fear. In a dental context, worry, anxiety, or tension are referred to as dental anxiety. According to reports, it is a prevalent issue that affects many societies. Aim: This cross-sectional study assessed the incidence and characteristics of dental anxiety in patients reporting to the dental operatory. Methodology: A questionnaire-based survey was carried out with 100 participants (50 males and 50 females), reporting to the Sharad Pawar Dental College and Hospital for dental treatment. The Modified Dental Anxiety Scale (MDAS), a systematic and validated tool, was used to measure the participants’ dental anxiety levels. Results: Descriptive statistical analysis was performed. Of the participating patients, 48% were female, 42% were male, and 90% of the population belonged to the high fear group. Merely 10% of the group had little fear (P < 0.001). A significant difference (P < 0.05) in the mean overall anxiety score among the age groups was seen, which decreased with age. The patient with dental anxiety was 35.84 ± 13.5 years old on average. Conclusion: The most popular dental procedures are significantly correlated with dental fear. The results of this study will assist a practicing dentist in identifying patients who suffer from dental anxiety so that they can receive primary treatment at a specialty clinic, along with comprehensive psychological evaluation, support, and therapy.

  • Open Access

    A Mixed-Method Analytical Cross-Sectional Research of Person-Centered Learning Behaviors Among Adolescent and Adult Learners

    by Nirupama Bhise, Vedprakash Mishra, Sweta Pisulkar, Sharayu Nimonkar, Vikram Belkhode, Chinmayee Dahihandekar

    Background In their academic lives, students progress from the stage of primary learning to the stage of adolescent learning and then to the stage of adult learning. At every step of learning, learners display particular learning habits, which must be mapped out to maximize learning. Objectives The objective of the present study is to evaluate the person-centered behaviors that influence learning among learners in adolescent and adult age groups by employing a learning behavior questionnaire that has been previously validated. Material and methods A cross-sectional study in which 944 participants were enrolled, including 456 adolescents from English-medium schools (aged 11 to 16 years) and 488 adults from a health professional institute (aged 18 to 23 years). The validated learning behavior questionnaire, which study participants rated on a scale of 0, 1, and 2, served as the study's quantitative component. The focus group discussion that was held for a group of adult and teenage students comprised the study's qualitative component. Using STATA-14 software (StataCorp LLC, College Station, USA), all of the responses were tallied and statistically examined. Results The mean scores of person-centered learning behaviors were significantly higher for learners in the adult age group than for learners in the adolescent age group. The findings of the component, which was qualitative in nature, were consistent with the findings of the learning behavior questionnaire analysis. For both adults and adolescents, the difference in mean person-centered learning scores was statistically negligible at a 5% level of significance (p=0.415 and p=0.368, respectively). Conclusion The study's checklist, which is self-monitoring in nature, may aid in the evaluation of learning behaviors and make it simpler for adult and adolescent learners to establish excellent learning habits.


  • Open Access

    A Ring for a Ring Finger: A Case Report on Finger Prosthesis

    by Sharayu Nimonkar, Vikram Belkhode, Pranali Nimonkar, Shreyas Gotoorkar

    The primary use of the hand is to grasp, hold, and manipulate objects. Perhaps the most obvious kind of non-verbal communication is the hand gesture. The most common types of partial hand loss are finger and partial finger amputations. Traumatic injuries, congenital absences, or abnormalities are frequent causes, and they create significant treatment issues. In addition to the acute loss of grab power, the disappearance of fingers may result in significant psychological harm. People who want their fingers replaced frequently have high expectations for how a prosthesis will look. This clinical report illustrates an easy way to keep an acrylic finger prosthetic in place.


  • Open Access

    Comparative evaluation of the efficacy of customized maxillary oral appliance with mandibular advancement appliance as a treatment modality for moderate obstructive sleep apnea patients—a randomized controlled trial

    by Vikram Belkhode, Surekha Godbole, Sharayu Nimonkar, Sweta Pisulkar, Pranali Nimonkar

    Background: Obstructive sleep apnea (OSA) is quite common among the adult population, according to recent epidemiological studies. The most frequently suggested alternate treatment for mild to moderate OSA is oral appliances (OA). The purpose of the present study was to assess as well as compare the effectiveness of custom-made maxillary oral appliances against mandibular advancement appliances in the care of individuals suffering from moderate obstructive sleep apnea. Methods: A prospective interventional research was carried out with 40 participants. Polysomnography (PSG) was done and the participants with an apnea-hypopnea index (AHI) >15–30 were involved in the research. Study participants were randomly split up into two test groups: group I was the “Control Group” (group treated with a mandibular advancement device (MAD), n=20), while group II was exposed to a “customized maxillary oral appliance” (CMOA, n=20). Both groups had reference measures for AHI, blood oxygen saturation (SpO2), oro-nasal airflow via respiratory disturbance index (RDI), and the Epworth Sleepiness Scale (ESS). Appliances were fabricated and delivered to the respective study group participants. PSG was again conducted after a period of 1 and 3 months of appliance delivery and re-evaluation was done for all the parameters and was compared with reference measurements. The facts were analyzed using descriptive and analytical statistical methods. The statistical program utilized in the study was “SPSS (Statistical Package for Social Sciences) Version 20.1.” After 1 and 3 months, the statistical significance between the two study groups was assessed at PP<0.001). The study results revealed a statistically significant depletion in mean AHI scores, improvement in mean SPO2 scores, and reduction in mean RDI scores and ESS scores when compared with reference measurements to 1 month, 1 to 3 months, and between reference measurements and 3 months. Conclusion: The CMOA was effective in managing moderate OSA and has great therapeutic potential. It can be an option for the MAD for treating patients suffering from moderate obstructive sleep apnea. Trial registration: The study was registered under Clinical Trials Registry-India and the registration number is CTRI/2020/07/026936. Registered on 31 July 2020


  • Open Access

    A narrative review on techniques of iris replication in an ocular prosthesis

    by SharayuVinod Nimonkar, VikramMurlidhar Belkhode, Chinmayee Dahihandekar, PranaliVinod Nimonkar, Sweta Pisulkar

    Task for a prosthodontist. The custom-made ocular prostheses are preferred over the prefabricated stock eye shells as it provides intimate contact with the tissue bed, enabling an ideal fit. For an esthetic ocular prosthesis, the precise positioning of an iris is a primary requirement to avoid the squint eye appearance. Various case reports are documented in the literature for centralizing the iris in the prosthetic eye. This review article explores the established methods and techniques for positioning the iris in a custom-made ocular prosthesis....