Elke Boone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elke Boone has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Aline Antoniou
Quality of Laboratories, Sciensano, 1050 Brussels, Belgium
1 shared publication - Aline Hébrant
Cancer Centre, Sciensano, 1050 Brussels, Belgium
1 shared publication - Cleo Keppens
Department of Public Health and Primary Care, Biomedical Quality Assurance Research Unit, University of Leuven, Leuven, Belgium
1 shared publication - Dido Lenze
Institut für Pathologie, Molekularpathologie, Charité –Universitätsmedizin Berlin, Berlin, Germany
1 shared publication - Elisabeth Marie C Dequeker
Biomedical Quality Assurance Research Unit, Department of Public Health and Primary Care, University of Leuven, Leuven, Belgium
1 shared publication - Elisabeth Moreau
AZ Delta vzw - Laboratorium Moleculaire Diagnostiek, Roeselare, Belgium
1 shared publication
Latest Publications
- Open Access
- 8 March 2021
- Published by Springer Nature in Virchows Archiv
- Vol. 479 (2) , 365-376
Evaluation of a worldwide EQA scheme for complex clonality analysis of clinical lymphoproliferative cases demonstrates a learning effect
Clonality analysis of immunoglobulin (IG) or T-cell receptor (TR) gene rearrangements is routine practice to assist diagnosis of lymphoid malignancies. Participation in external quality assessment (EQA) aids laboratories in identifying systematic shortcomings. The aim of this study was to evaluate laboratories’ improvement in IG/TR analysis and interpretation during five EQA rounds between 2014 and 2018. Each year, participants received a total of five cases for IG and five cases for TR testing. Paper-based cases were included for analysis of the final molecular conclusion that should be interpreted based on the integration of the individual PCR results. Wet cases were distributed for analysis of their routine protocol as well as evaluation of the final molecular conclusion. In total, 94.9% (506/533) of wet tests and 97.9% (829/847) of paper tests were correctly analyzed for IG, and 96.8% (507/524) wet tests and 93.2% (765/821) paper tests were correctly analyzed for TR. Analysis scores significantly improved when laboratories participated to more EQA rounds (p=0.001). Overall performance was significantly lower (p=0.008) for non-EuroClonality laboratories (95% for IG and 93% for TR) compared to EuroClonality laboratories (99% for IG and 97% for TR). The difference was not related to the EQA scheme year, anatomic origin of the sample, or final clinical diagnosis. This evaluation showed that repeated EQA participation helps to reduce performance differences between laboratories (EuroClonality versus non-EuroClonality) and between sample types (paper versus wet). The difficulties in interpreting oligoclonal cases highlighted the need for continued education by meetings and EQA schemes.
- 8 March 2021
- Published by Springer Nature in Virchows Archiv
- Vol. 479 (2) , 365-376
Open AccessEvaluation of a worldwide EQA scheme for complex clonality analysis of clinical lymphoproliferative cases demonstrates a learning effect
Clonality analysis of immunoglobulin (IG) or T-cell receptor (TR) gene rearrangements is routine practice to assist diagnosis of lymphoid malignancies. Participation in external quality assessment (EQA) aids laboratories in identifying systematic shortcomings. The aim of this study was to evaluate laboratories’ improvement in IG/TR analysis and interpretation during five EQA rounds between 2014 and 2018. Each year, participants received a total of five cases for IG and five cases for TR testing. Paper-based cases were included for analysis of the final molecular conclusion that should be interpreted based on the integration of the individual PCR results. Wet cases were distributed for analysis of their routine protocol as well as evaluation of the final molecular conclusion. In total, 94.9% (506/533) of wet tests and 97.9% (829/847) of paper tests were correctly analyzed for IG, and 96.8% (507/524) wet tests and 93.2% (765/821) paper tests were correctly analyzed for TR. Analysis scores significantly improved when laboratories participated to more EQA rounds (p=0.001). Overall performance was significantly lower (p=0.008) for non-EuroClonality laboratories (95% for IG and 93% for TR) compared to EuroClonality laboratories (99% for IG and 97% for TR). The difference was not related to the EQA scheme year, anatomic origin of the sample, or final clinical diagnosis. This evaluation showed that repeated EQA participation helps to reduce performance differences between laboratories (EuroClonality versus non-EuroClonality) and between sample types (paper versus wet). The difficulties in interpreting oligoclonal cases highlighted the need for continued education by meetings and EQA schemes.
- Open Access
Standardization of Somatic Variant Classifications in Solid and Haematological Tumours by a Two-Level Approach of Biological and Clinical Classes: An Initiative of the Belgian ComPerMed Expert Panel
In most diagnostic laboratories, targeted next-generation sequencing (NGS) is currently the default assay for the detection of somatic variants in solid as well as haematological tumours. Independent of the method, the final outcome is a list of variants that differ from the human genome reference sequence of which some may relate to the establishment of the tumour in the patient. A critical point towards a uniform patient management is the assignment of the biological contribution of each variant to the malignancy and its subsequent clinical impact in a specific malignancy. These so-called biological and clinical classifications of somatic variants are currently not standardized and are vastly dependent on the subjective analysis of each laboratory. This subjectivity can thus result in a different classification and subsequent clinical interpretation of the same variant. Therefore, the ComPerMed panel of Belgian experts in cancer diagnostics set up a working group with the goal to harmonize the biological classification and clinical interpretation of somatic variants detected by NGS. This effort resulted in the establishment of a uniform, two-level classification workflow system that should enable high consistency in diagnosis, prognosis, treatment and follow-up of cancer patients. Variants are first classified into a tumour-independent biological five class system and subsequently in a four tier ACMG clinical classification. Here, we describe the ComPerMed workflow in detail including examples for each step of the pipeline. Moreover, this workflow can be implemented in variant classification software tools enabling automatic reporting of NGS data, independent of panel, method or analysis software.
Open AccessStandardization of Somatic Variant Classifications in Solid and Haematological Tumours by a Two-Level Approach of Biological and Clinical Classes: An Initiative of the Belgian ComPerMed Expert Panel
In most diagnostic laboratories, targeted next-generation sequencing (NGS) is currently the default assay for the detection of somatic variants in solid as well as haematological tumours. Independent of the method, the final outcome is a list of variants that differ from the human genome reference sequence of which some may relate to the establishment of the tumour in the patient. A critical point towards a uniform patient management is the assignment of the biological contribution of each variant to the malignancy and its subsequent clinical impact in a specific malignancy. These so-called biological and clinical classifications of somatic variants are currently not standardized and are vastly dependent on the subjective analysis of each laboratory. This subjectivity can thus result in a different classification and subsequent clinical interpretation of the same variant. Therefore, the ComPerMed panel of Belgian experts in cancer diagnostics set up a working group with the goal to harmonize the biological classification and clinical interpretation of somatic variants detected by NGS. This effort resulted in the establishment of a uniform, two-level classification workflow system that should enable high consistency in diagnosis, prognosis, treatment and follow-up of cancer patients. Variants are first classified into a tumour-independent biological five class system and subsequently in a four tier ACMG clinical classification. Here, we describe the ComPerMed workflow in detail including examples for each step of the pipeline. Moreover, this workflow can be implemented in variant classification software tools enabling automatic reporting of NGS data, independent of panel, method or analysis software.