Shuangyuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuangyuan Wang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Fujia Sun
School of Mechanical Engineering, University of Shanghai for Science and Technology
3 shared publications- Hongchao Wang
Zhengzhou University of Light Industry
3 shared publications - Wenliao Du
School of Mechanical Engineering, Zhengzhou University of Light Industry, Zhengzhou, China
3 shared publications Ao Wang
2 shared publications- Fujia Sun
University of Shanghai for Science and Technology
2 shared publications Furong Li
Department of Electronic and Electrical Engineering, University of Bath, Bath, U.K.
2 shared publications
Latest Publications
- 7 July 2026
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 50 (18) , 7732-7751
Evolution of Facial Assessment in Aesthetic Medicine: 3D Imaging, Digital Analysis, and Patient-Reported Outcomes
Facial assessment is central to treatment planning and outcome evaluation. Traditional approaches, including visual inspection, manual anthropometry, and classical esthetic proportions, are limited by inter-observer variability and challenges in accounting for cultural and demographic diversity. Recent advances in digital imaging and computational analysis now enable more objective, reproducible, and clinically standardized evaluation. This structured review employed a transparent literature search across Web of Science, PubMed, and Google Scholar to identify peer-reviewed publications published between 2020 and 2025. The aim was to provide a comprehensive overview of contemporary facial assessment technologies. The retrieved evidence was synthesized narratively and qualitatively with emphasis on clinical accuracy, reproducibility, workflow integration, and patient-reported outcome measures (PROMs). A large body of contemporary literature was reviewed and synthesized. The synthesized literature demonstrates a clear progression from qualitative visual assessment toward quantitative and technology-supported evaluation. Modern three-dimensional (3D) imaging systems achieve submillimeter precision, enabling reliable volumetric measurement for surgical planning and longitudinal monitoring. Automated approaches assist in grading wrinkles, pigmentation, and other aging-related features. However, important limitations remain, including inconsistent acquisition protocols, restricted demographic representation in reference datasets, and the need for clearer standards for prospective validation and workflow integration. Facial assessment in esthetic medicine is evolving toward multimodal integration of 3D volumetry, AI-driven diagnostics, and PROMs. Future clinical practice will benefit from the integration of objective morphological data with patient-reported outcomes, although developing unified platforms requires further prospective validation and real-world clinical studies. Not applicable (Review Article). This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- 7 July 2026
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 50 (18) , 7732-7751
Evolution of Facial Assessment in Aesthetic Medicine: 3D Imaging, Digital Analysis, and Patient-Reported Outcomes
Facial assessment is central to treatment planning and outcome evaluation. Traditional approaches, including visual inspection, manual anthropometry, and classical esthetic proportions, are limited by inter-observer variability and challenges in accounting for cultural and demographic diversity. Recent advances in digital imaging and computational analysis now enable more objective, reproducible, and clinically standardized evaluation. This structured review employed a transparent literature search across Web of Science, PubMed, and Google Scholar to identify peer-reviewed publications published between 2020 and 2025. The aim was to provide a comprehensive overview of contemporary facial assessment technologies. The retrieved evidence was synthesized narratively and qualitatively with emphasis on clinical accuracy, reproducibility, workflow integration, and patient-reported outcome measures (PROMs). A large body of contemporary literature was reviewed and synthesized. The synthesized literature demonstrates a clear progression from qualitative visual assessment toward quantitative and technology-supported evaluation. Modern three-dimensional (3D) imaging systems achieve submillimeter precision, enabling reliable volumetric measurement for surgical planning and longitudinal monitoring. Automated approaches assist in grading wrinkles, pigmentation, and other aging-related features. However, important limitations remain, including inconsistent acquisition protocols, restricted demographic representation in reference datasets, and the need for clearer standards for prospective validation and workflow integration. Facial assessment in esthetic medicine is evolving toward multimodal integration of 3D volumetry, AI-driven diagnostics, and PROMs. Future clinical practice will benefit from the integration of objective morphological data with patient-reported outcomes, although developing unified platforms requires further prospective validation and real-world clinical studies. Not applicable (Review Article). This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
- Open Access
- 6 April 2026
- Published by MDPI AG in Electronics
- Vol. 15 (7) , 1526
Design and Implementation of a High-Resolution Real-Time Ultrasonic Endoscopy Imaging System Based on FPGA and Coded Excitation
High-frequency endoscopic ultrasound is crucial for the early diagnosis of gastrointestinal tumors. However, achieving high axial resolution, deep tissue signal-to-noise ratio, and real-time data processing simultaneously remains a significant challenge in hardware implementation. This paper proposes a miniaturized real-time high-frequency imaging system based on the Xilinx Artix-7 FPGA. To overcome attenuation limitations of high-frequency signals, we employ a 4-bit Barker code-encoded excitation scheme coupled with a programmable ±100 V high-voltage transmission circuit. This effectively enhances echo energy without exceeding peak voltage safety thresholds. At the receiver end, the system utilizes a multi-channel analog front end integrated with mixed-signal time-gain compensation technology. Furthermore, to address transmission bottlenecks for massive echo data, we designed a Low-Voltage Differential Signaling (LVDS) interface logic based on dynamic phase calibration, ensuring stable, high-speed data transfer to the host computer via USB 3.0. Experimental results with a 20 MHz transducer demonstrate that the system achieves real-time B-mode imaging at 30 frames per second. Phantom testing revealed an axial resolution of 0.13 mm, enabling clear differentiation of 0.1 mm microstructures. Compared to conventional single-pulse excitation, coded excitation technology improved signal-to-noise ratio (SNR) by approximately 4.5 dB at a depth of 40 mm. These results validate the system’s capability for high-precision deep imaging suitable for clinical endoscopy applications, delivered in a compact, low-power form factor.
- 6 April 2026
- Published by MDPI AG in Electronics
- Vol. 15 (7) , 1526
Open AccessDesign and Implementation of a High-Resolution Real-Time Ultrasonic Endoscopy Imaging System Based on FPGA and Coded Excitation
High-frequency endoscopic ultrasound is crucial for the early diagnosis of gastrointestinal tumors. However, achieving high axial resolution, deep tissue signal-to-noise ratio, and real-time data processing simultaneously remains a significant challenge in hardware implementation. This paper proposes a miniaturized real-time high-frequency imaging system based on the Xilinx Artix-7 FPGA. To overcome attenuation limitations of high-frequency signals, we employ a 4-bit Barker code-encoded excitation scheme coupled with a programmable ±100 V high-voltage transmission circuit. This effectively enhances echo energy without exceeding peak voltage safety thresholds. At the receiver end, the system utilizes a multi-channel analog front end integrated with mixed-signal time-gain compensation technology. Furthermore, to address transmission bottlenecks for massive echo data, we designed a Low-Voltage Differential Signaling (LVDS) interface logic based on dynamic phase calibration, ensuring stable, high-speed data transfer to the host computer via USB 3.0. Experimental results with a 20 MHz transducer demonstrate that the system achieves real-time B-mode imaging at 30 frames per second. Phantom testing revealed an axial resolution of 0.13 mm, enabling clear differentiation of 0.1 mm microstructures. Compared to conventional single-pulse excitation, coded excitation technology improved signal-to-noise ratio (SNR) by approximately 4.5 dB at a depth of 40 mm. These results validate the system’s capability for high-precision deep imaging suitable for clinical endoscopy applications, delivered in a compact, low-power form factor.
- 1 April 2026
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- p. 1-10
Finite element optimization of a magnetic anchor traction system for colonic ESD
1. Endoscopic submucosal dissection (ESD) is an established minimally invasive technique for the treatment of early-stage gastrointestinal neoplasms, enabling en bloc resection while preserving org...
- 1 April 2026
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- p. 1-10
Finite element optimization of a magnetic anchor traction system for colonic ESD
1. Endoscopic submucosal dissection (ESD) is an established minimally invasive technique for the treatment of early-stage gastrointestinal neoplasms, enabling en bloc resection while preserving org...
- 27 February 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (4) , 045002
Parameter optimization and finite element simulation analysis of skin graft harvesting using an electric dermatome
Column skin transplantation is an innovative technique for repairing extensive burns and complex wounds, offering advantages such as theoretically unlimited donor areas and minimal donor site damage. Currently, manual trephination is the primary clinical method for skin harvesting, which suffers from low efficiency and inconsistent quality of the obtained skin cores. To improve efficiency and skin core quality, some researchers have attempted to introduce powered trephination. However, due to the inability to conduct direct human experiments with powered trephines, there is a lack of systematic quantitative data supporting the relationship between its key operational parameters and the response mechanisms of skin tissue, which hinders its practical application. This study combines finite element simulation and animal experiments. Using the ABAQUS/EXPLICIT platform, a three-dimensional multilayer finite element model of the skin was established to analyze the mechanical response and column-forming quality during the puncture process under different relative humidity levels (RH = 98%, 76%, 43%) and drill rotational speeds (V = 10, 30, 50, 70, 90 rad/s). Subsequently, pig skin, which closely resembles human skin in structure, was used for experimental validation. The results showed that smooth, regular, and nearly cylindrical skin columns could be obtained under optimal humidity and rotational speed conditions, facilitating the preservation of skin appendages and functional recovery after transplantation. This study provides a solid theoretical foundation and methodological support for the mechanical modeling and process parameter optimization of skin column extraction, contributing to the design of novel electric skin grafting devices, preoperative individualized assessments, and clinical application promotion. It holds significant clinical value and engineering implications.
- 27 February 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (4) , 045002
Parameter optimization and finite element simulation analysis of skin graft harvesting using an electric dermatome
Column skin transplantation is an innovative technique for repairing extensive burns and complex wounds, offering advantages such as theoretically unlimited donor areas and minimal donor site damage. Currently, manual trephination is the primary clinical method for skin harvesting, which suffers from low efficiency and inconsistent quality of the obtained skin cores. To improve efficiency and skin core quality, some researchers have attempted to introduce powered trephination. However, due to the inability to conduct direct human experiments with powered trephines, there is a lack of systematic quantitative data supporting the relationship between its key operational parameters and the response mechanisms of skin tissue, which hinders its practical application. This study combines finite element simulation and animal experiments. Using the ABAQUS/EXPLICIT platform, a three-dimensional multilayer finite element model of the skin was established to analyze the mechanical response and column-forming quality during the puncture process under different relative humidity levels (RH = 98%, 76%, 43%) and drill rotational speeds (V = 10, 30, 50, 70, 90 rad/s). Subsequently, pig skin, which closely resembles human skin in structure, was used for experimental validation. The results showed that smooth, regular, and nearly cylindrical skin columns could be obtained under optimal humidity and rotational speed conditions, facilitating the preservation of skin appendages and functional recovery after transplantation. This study provides a solid theoretical foundation and methodological support for the mechanical modeling and process parameter optimization of skin column extraction, contributing to the design of novel electric skin grafting devices, preoperative individualized assessments, and clinical application promotion. It holds significant clinical value and engineering implications.
- 2 January 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
A cement plant load disaggregation method based on an improved UNet model for fine-grained energy monitoring
- 2 January 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 254
A cement plant load disaggregation method based on an improved UNet model for fine-grained energy monitoring
- 11 September 2025
- Published by Springer Nature in Energy Efficiency
- Vol. 18 (7) , 1-17
ChronoFuse-TCN: A progressive temporal convolutional network for multi-scale and spatiotemporal load disaggregation
- 11 September 2025
- Published by Springer Nature in Energy Efficiency
- Vol. 18 (7) , 1-17
ChronoFuse-TCN: A progressive temporal convolutional network for multi-scale and spatiotemporal load disaggregation
- 6 April 2025
- Published by Elsevier in Expert Systems with Applications
- Vol. 280
Multi-feature fusion for accurate polyp segmentation using pyramid visual transformers
- 6 April 2025
- Published by Elsevier in Expert Systems with Applications
- Vol. 280
Multi-feature fusion for accurate polyp segmentation using pyramid visual transformers
- 1 October 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 100
Enhanced YOLOv8 with attention mechanisms for accurate detection of colorectal polyps
- 1 October 2024
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 100
Enhanced YOLOv8 with attention mechanisms for accurate detection of colorectal polyps