Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ali Iskandar has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Cross-Pile Calibration Approach for Deriving Local Skin Friction Correlations of Bored Piles

    by Ali Iskandar, Agustinus Purna Irawan, Aksan Kawanda

    The design of bored piles in Jakarta is often conservative due to reliance on general empirical methods that fail to capture the high shaft friction characteristic of prevalent cemented soils in the area. This study introduces a Cross-Pile Calibration (CPC) strategy that develops site-specific correlations between Standard Penetration Test (SPT) N-values and maximum skin friction. This method uses a combination of load test data from multiple projects and fully mobilized piles to calibrate predictions for those with partial mobilization data in similar soil strata. The study proposes new linear correlations for key soil groups, including skin friction equal to 3.33 times the N-value for cemented sand, capped at 300 kPa, and skin friction equal to 4.0 times the N-value for clay-silt, capped at 160 kPa. Validation against 27 independent piles shows that, on average, applying the CPC-derived correlations within a rational framework yields shaft capacity projections that are 29% higher than those predicted by the classical Reese and Wright method, quantifying a significant reduction in design conservatism. This work provides a practical, data-driven framework for optimizing bored pile design in Jakarta's complex geology.

  • Machine Learning Prediction of Pile Capacity Based on EMX Value from Dynamic Test

    by Ali Iskandar, Agustinus Purna Irawan, Aksan Kawanda, Daniel Christianto, Sherlin Angelina

  • Open Access

    SPT-EFFECTIVE SHEAR PARAMETER CORRELATION FOR SOFT CLAY IN JAKARTA USING BIG DATA

    by Ali Iskandar, Gregorius Sandjaja Sentosa, Aksan Kawanda, Felicia Yohana, Felicia Refalina Tantobudiono

    This study aims to develop a practical model to estimate the shear strength parameters of clay soils, such as effective cohesion (c¢), angle of internal friction (f¢), and elasticity modulus in a more efficient and economical, by using Standard Penetration Test (SPT) and index properties data (including grain size analysis and Atterberg test). This study focuses on fine-grained soils (especially in Jakarta) in two consistency groups, namely very soft clay (C01, SPT 0-2 blows/ft) and soft clay (C02, SPT 2-4 blows/ft). The analysis was conducted by establishing a linear relationship between mean effective stress (p¢) and deviatoric stress (q), with an additional ±10% envelope to account for data variability. The results show that the linear regression of p¢-q adequately represents soil behavior for both consistency groups. The ±10% envelope successfully accommodates variations including the effect of plasticity index (PI), indicating that this model can serve as a practical alternative in geotechnical design when triaxial test data and undistrurbed sampling test are not available.

  • Open Access

    STATISTICAL CORRECTION OF A DYNAMIC PILE BEARING CAPACITY FORMULA BASED ON PDA DATA

    by Sherlin Angelina, Hendy Wijaya, Ali Iskandar, Agus Johan, Aksan Kawanda, Daniel Tri Purnomo

    The calculation of pile bearing capacity using a dynamic formula is considered a practical approach for evaluating the capacity of foundation piles. However, its results are often questioned when compared to the CAPWAP analysis outcomes derived from PDA testing. This study aims to assess the accuracy of the dynamic formula, develop a correction model using a statistical approach in the form MLR, and evaluate the effectiveness of the resulting correction model in predicting pile bearing capacity. A total of 84 pile datasets were utilized in this research, comprising various pile dimensions and PDA-derived parameters, including the maximum energy transferred to the pile (EMX), permanent pile settlement (S = DFN), and elastic settlement (C = DMX – DFN). The analysis results indicated that the dynamic formula could be corrected using the MLR approach. The correction model produced multiplier coefficients of 1.09 for parameter S and 0.67 for parameter C, with a coefficient of determination of 0.96 and a MAPE value of 19.21%, which represents the average deviation of the predicted results from the actual values and falls into the accurate category based on Lewis’ classification. The model is deemed sufficiently reliable for use as an alternative method in the preliminary evaluation of pile bearing capacity. Abstrak Perhitungan daya dukung tiang menggunakan formula dinamik merupakan pendekatan praktis dalam mengevaluasi kapasitas tiang fondasi. Namun, hasil perhitungannya kerap diragukan jika dibandingkan dengan hasil analisis CAPWAP dari uji PDA. Penelitian ini bertujuan untuk mengevaluasi akurasi formula dinamik, mengembangkan model koreksi dengan pendekatan statistik berupa MLR, serta menilai efektivitas model koreksi yang dihasilkan dalam memprediksi daya dukung tiang. Pada penelitian ini digunakan 84 data tiang dengan variasi dimensi tiang dan parameter dari uji PDA yang berupa energi maksimum yang tertransfer ke tiang (EMX), penurunan permanen tiang (S = DFN), dan penurunan elastis tiang (C = DMX – DFN). Hasil analisis menunjukkan bahwa formula dinamik dapat dikoreksi melalui pendekatan MLR. Model koreksi menghasilkan koefisien pengali untuk parameter S sebesar 1,09 dan C sebesar 0,67, serta memiliki koefisien determinasi sebesar 0,96 dan nilai MAPE yang menunjukkan rata-rata deviasi hasil prediksi terhadap aktual sebesar 19,21%, yang termasuk dalam kategori akurat menurut klasifikasi Lewis. Model ini dinilai cukup andal untuk digunakan sebagai pendekatan alternatif dalam tahap evaluasi awal daya dukung tiang.

  • Open Access

    PREDIKSI PENURUNAN BANGUNAN TINGGI YANG BERLOKASI DI JAKARTA UTARA

    by Meli Susiyanti, Hendy Wijaya, Ali Iskandar

    Buildings can experience land subsidence caused by immediate settlement due to loading and consolidation. Land subsidence is a natural phenomenon and requires attention in areas around the coast or alluvial plains because the soil is very soft. Pile foundations are part of the construction that functions to transfer the load from the construction above to the hard soil layer that is very deep. This study discusses the settlement of the high-rise building studied located in the North Jakarta area. Data collection of soil, buildings and foundations was carried out and then analyzed using a 3D analysis program (finite difference method). The analysis was carried out to determine the amount of settlement that will occur and how long the settlement will continue. The settlement of the pile group foundation in this study was caused by elastic compression of the piles and consolidation settlement. The time required to reach 90% consolidation was 110961 days or 308 years from the beginning of the project period. The settlement that occurred when the building was completed was 1231.54 mm, during the 100-year project period was 2214.65 mm, and the largest settlement was when the soil was 90% consolidated at 2676.11 mm. Abstrak Bangunan dapat mengalami penurunan tanah yang disebabkan oleh penurunan segera akibat pembebanan dan konsolidasi. Penurunan tanah merupakan suatu fenomena alam dan perlu perhatian di daerah sekitar pantai atau dataran alluvial karena tanahnya sangat lunak. Fondasi tiang pancang merupakan bagian konstruksi yang berfungsi untuk mentransfer beban dari konstruksi di atasnya ke lapisan tanah keras yang letaknya sangat dalam. Penelitian ini membahas mengenai penurunan bangunan tinggi yang diteliti terletak di kawasan Jakarta Utara. Pengumpulan data tanah, bangunan dan fondasi dilakukan untuk kemudian dianalisis dengan bantuan program analisis 3D (metode beda hingga). Analisis dilakukan untuk mencari besarnya penurunan yang akan terjadi dan sampai kapan penurunan terus terjadi. Penurunan fondasi kelompok tiang dalam penelitian ini diakibatkan oleh kompresi elastis tiang dan penurunan konsolidasi. Waktu yang dibutuhkan untuk mencapai konsolidasi 90% adalah 110961 hari atau 308 tahun sejak awal masa proyek. Penurunan yang terjadi pada saat bangunan selesai adalah sebesar 1231,54 mm, pada saat masa proyek 100 tahun sebesar 2214,65 mm, dan penurunan terbesar yaitu pada saat tanah terkonsolidasi 90% sebesar 2676,11 mm.

  • Open Access

    ANALYSIS OF LOAD TRANSFER PLATFORM THICKNESS ON LOAD TRANSFER EFFECTIVENESS AND ROAD STABILITY IN SOFT SOIL

    by Andrawan Andrawan, Hendy Wijaya, Ali Iskandar, Albert Johan

    Reinforcement of road embankments on soft soils is a common challenge in infrastructure projects, especially in conditions of low bearing capacity and large settlement potential. One widely used solution is the pile embankment system with the addition of granular Load Transfer Platform. This study aims to numerically evaluate the effect of variations in LTP quality and thickness on system performance. Modeling was conducted using the two-dimensional finite element method, with variations in CBR values of 40% and 45%, and LTP thicknesses of 1 m, 1.5 m, and 2 m. The parameters analyzed include the amount of embankment settlement, slope safety factor, axial force on piles, and visualization of arching effect. The results showed that increasing the quality and thickness of the LTP was able to reduce embankment settlement and increase the factor of safety, especially under short-term conditions. The axial force on the piles also increased as the stiffness of the LTP increased, although at a certain thickness it was thought that there was more optimal force attenuation. These findings indicate the importance of appropriate LTP configuration in the design of soft soil reinforcement systems. Abstrak Perkuatan timbunan jalan di atas tanah lunak merupakan tantangan umum dalam proyek infrastruktur, khususnya pada kondisi daya dukung rendah dan potensi penurunan yang besar. Salah satu solusi yang banyak digunakan adalah sistem pile embankment dengan penambahan load transfer platform (LTP) berbahan granular. Penelitian ini bertujuan untuk mengevaluasi pengaruh variasi kualitas dan ketebalan LTP terhadap kinerja sistem secara numerik. Pemodelan dilakukan menggunakan metode elemen hingga dua dimensi, dengan variasi nilai CBR sebesar 40% dan 45%, serta ketebalan LTP 1 m, 1,5 m, dan 2 m. Parameter yang dianalisis meliputi besarnya penurunan timbunan, faktor keamanan lereng, gaya aksial pada tiang pancang, serta visualisasi arching effect. Hasil penelitian menunjukkan bahwa peningkatan kualitas dan ketebalan LTP mampu menurunkan penurunan timbunan dan meningkatkan faktor keamanan, khususnya pada kondisi jangka pendek. Gaya aksial pada tiang juga meningkat seiring peningkatan kekakuan LTP, meskipun pada ketebalan tertentu diduga terjadi peredaman gaya yang lebih optimal. Temuan ini menunjukkan pentingnya konfigurasi LTP yang tepat dalam desain sistem perkuatan tanah lunak.

  • Open Access

    STUDI KASUS PENURUNAN MUKA TANAH DAN MUKA AIR TANAH DI JAKARTA PUSAT TAHUN 2010-2022

    by Ali Iskandar, Chaidir Anwar Makarim, Tiara Kumala Chandra

    DKI Jakarta, as the center of Indonesia's economic and governmental activities, faces serious challenges related to significant land subsidence. High population density, rapid industrial growth, and increasing groundwater demand have triggered overexploitation of groundwater. This phenomenon, known as groundwater extraction, is a major factor causing alarming land subsidence in Central Jakarta. This study analyzes land subsidence and groundwater level data in Central Jakarta over the period 2010-2022, focusing on the impact of groundwater exploitation. The analysis methods include spatial analysis, statistical analysis, and literature review to identify the relationship between groundwater exploitation and land subsidence. The results show that land subsidence in Central Jakarta ranges from 2-15 cm per year, with an increasing trend. Areas with the highest groundwater exploitation showed the most significant subsidence rates. The study also identified other factors that contribute to land subsidence, such as natural consolidation of alluvium and construction loads. The implications of these findings highlight the need for sustainable groundwater management and strict groundwater exploitation control policies to prevent more severe impacts in the future. Abstrak DKI Jakarta, sebagai pusat kegiatan ekonomi dan pemerintahan Indonesia, menghadapi tantangan serius terkait penurunan muka tanah yang signifikan. Kepadatan penduduk yang tinggi, pertumbuhan industri yang pesat, dan kebutuhan air tanah yang meningkat telah memicu eksploitasi air tanah secara berlebihan. Fenomena ini, yang dikenal sebagai groundwater extraction, menjadi faktor utama penyebab penurunan muka tanah yang mengkhawatirkan di Jakarta Pusat. Studi ini menganalisis data penurunan muka tanah dan muka air tanah di Jakarta Pusat selama periode 2010-2022, dengan fokus pada dampak eksploitasi air tanah. Metode analisis meliputi analisis spasial, analisis statistik, dan tinjauan literatur untuk mengidentifikasi hubungan antara eksploitasi air tanah dan penurunan muka tanah. Hasil penelitian menunjukkan bahwa penurunan muka tanah di Jakarta Pusat berkisar antara 2-15 cm per tahun, dengan tren yang terus meningkat. Wilayah dengan eksploitasi air tanah tertinggi menunjukkan tingkat penurunan muka tanah yang paling signifikan. Studi ini juga mengidentifikasi faktor-faktor lain yang berkontribusi terhadap penurunan muka tanah, seperti konsolidasi alami tanah aluvium dan beban konstruksi. Implikasi dari temuan ini menyoroti perlunya pengelolaan air tanah yang berkelanjutan dan kebijakan pengendalian eksploitasi air tanah yang ketat untuk mencegah dampak yang lebih parah di masa depan.


  • Open Access

    PERBANDINGAN STABILITAS BERBAGAI TIPE DINDING PENAHAN TANAH PADA PROYEK TOWER TURYAPADA DI BALI

    by Johny Five, Hendy Wijaya, Ali Iskandar

    This study compares the stability of cantilever retaining walls (DPT) with the combined method of MSE (Mechanically Stabilized Earth) retaining walls and soil nailing retaining walls under the same soil conditions. The stability analysis is conducted by considering shear, overturning, and bearing capacity factors. The results show that MSE retaining walls have the highest overturning safety factor value of 10.83, which exceeds the minimum SNI standard. MSE retaining walls also show the highest shear safety factor value of 7.54, while the highest bearing capacity safety factor value is found in cantilever retaining walls, amounting to 28.73. The pullout safety factor values in soil nailing are also analyzed, indicating the need for adjustments in nail length or excavation sequence to achieve the required minimum values. This study suggests the use of various types of retaining walls and more diverse soil conditions for a more comprehensive analysis in the future, as well as the application of 3D computer programs to model the interaction between retaining structures and the surrounding soil in greater detail. Abstrak Penelitian ini membandingkan stabilitas dinding penahan tanah (DPT) tipe kantilever dengan metode gabungan DPT MSE (mechanically stabilized earth) dan DPT soil nailing dalam kondisi tanah yang sama. Analisis stabilitas dilakukan dengan mempertimbangkan faktor geser, guling, dan daya dukung. Hasil penelitian menunjukkan bahwa DPT MSE memiliki nilai faktor keamanan guling terbesar sebesar 10,83, yang melebihi standar minimum SNI. DPT MSE menunjukkan nilai faktor keamanan geser terbesar sebesar 7,54, dan nilai faktor keamanan daya dukung terbesar adalah DPT kantilever sebesar 28,73. Nilai faktor keamanan akibat cabut (pullout) pada soil nailing juga dianalisis, dengan hasil menunjukkan perlunya penyesuaian panjang nail atau urutan penggalian untuk mencapai nilai minimum yang disyaratkan. Penelitian ini menyarankan penggunaan berbagai jenis DPT dan kondisi tanah yang lebih beragam untuk analisis yang lebih komprehensif di masa mendatang, serta penerapan program komputer 3D untuk memodelkan interaksi antara struktur penahan tanah dan tanah di sekitarnya dengan lebih detail.


  • Open Access

    HUBUNGAN EFISIENSI KAPASITAS DUKUNG TERHADAP JARAK ANTAR TIANG PADA KELOMPOK TIANG

    by Shaq Qorull'Ali Mahmud, Ali Iskandar

    This study aims to determine the most effective bored pile spacing to support the load of a structure. This study used a group pile configuration with dimensions 10x10, 30 m long, and 1 m diameter The distance between the piles plays a role in the bearing capacity of the bored pile group foundation. Therefore, research was conducted with a distance between poles of 1.5D, 2D, 2.5D, and 3D. To determine the efficiency value of each pile spacing, the pile group efficiency was calculated using 6 different methods. This study aims to compare 6 methods of calculating the efficiency of group piles with varying distances between piles. So that it can be known the distance between piles and the most effective method of calculating the efficiency of the pile group based on the 3D finite element method in clay soil. For an economical design, it is necessary to consider the distance between piles in a group of piles. Abstrak Penelitian ini memiliki maksud untuk memahami jarak tiang bor yang tepat dan efektif untuk mendukung beban suatu struktur. Penelitian ini menggunakan konfigurasi tiang kelompok dengan dimensi 10x10, panjang tiang 30 m, dan diameter tiang sebesar 1 m. Jarak antara tiang pada suatu kelompok tiang mempengaruhi daya dukung dari suatu fondasi kelompok tiang. Oleh karena itu, dilakukan penelitian dengan jarak antar tiang digunakan 1,5D, 2D, 2,5D, dan 3D. Untuk mengetahui nilai efisiensi dari setiap jarak antar tiang, dilakukan perhitungan efisensi kelompok tiang menggunakan 6 metode yang berbeda dimana salah satunya menggunakan metode elemen hingga 3D. Hal ini bertujuan untuk membandingkan 6 metode perhitungan efisiensi tiang kelompok dengan jarak antar tiang yang bervariasi. Sehingga dapat diketahui jarak antar tiang dan metode perhitungan efisiensi kelompok tiang yang paling efektif berdasarkan metode elemen hingga 3D pada tanah lempung. Untuk desain yang ekonomis, perlu dipertimbangkan jarak antar tiang pada suatu kelompok tiang.