Paola Alexandra Prada-Tiedemann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paola Alexandra Prada-Tiedemann has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
Allison M. Curran
9 shared publications- Nathaniel J. Hall
Department of Animal & Food Sciences, Texas Tech University, Lubbock, TX 79409, USA
7 shared publications - Kenneth Furton
Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199, USA
6 shared publications - Edgar O. Aviles Rosa
1 Department of Animal and Food Science, Texas Tech University, Lubbock, TX, United States
5 shared publications - Jorge Ulises Rojas-Guevara
Fundacion Universitaria Agraria de Colombia - Uniagraria
4 shared publications Kenneth G. Furton
Department of Chemistry and Biochemistry, International Forensic Research Institute, Florida International University, Miami, FL, United States
4 shared publications
Latest Publications
- Open Access
Improving Explosive Detection Dog Performance in Sealed Parcel Searches Through a Targeted Training Intervention
Explosive detection dogs are routinely deployed for parcel screening, yet realistic sealed-parcel searches may present challenges not captured by conventional odor-recognition training. In 2025, a black box study of ANSI/ASB Standard 092 identified substantially reduced detection of explosives in tape-sealed parcels, suggesting a potential training gap in this search scenario. This follow-on study evaluated whether brief, progressive training could improve dog performance in sealed-parcel searches. Thirteen operational dog teams participated in trials conducted in Lubbock, Texas, and Miami, Florida. Teams completed a baseline assessment using tape-sealed parcels containing 50 g of C4 or TNT, or distractors, followed by an odor recognition test (ORT) using controlled explosive odor presentations. Following the correction of identified odor-recognition deficiencies, teams completed a training intervention manipulating odor availability through variable parcel venting and requiring progression from odor-source recognition to trained final response. Performance was reassessed using the same parcel configuration. All teams detected C4 during the ORT, whereas only two teams detected TNT. Following intervention, overall sealed-parcel detection sensitivity increased by 35 percentage points (p = 0.0078). C4 detection increased from 38% to 69%, while TNT detection increased from 15% to 54%, although neither individual change reached statistical significance. The results demonstrate that odor recognition does not necessarily translate to effective source localization in sealed parcels and support progressive, operationally representative parcel-search training.
Open AccessImproving Explosive Detection Dog Performance in Sealed Parcel Searches Through a Targeted Training Intervention
Explosive detection dogs are routinely deployed for parcel screening, yet realistic sealed-parcel searches may present challenges not captured by conventional odor-recognition training. In 2025, a black box study of ANSI/ASB Standard 092 identified substantially reduced detection of explosives in tape-sealed parcels, suggesting a potential training gap in this search scenario. This follow-on study evaluated whether brief, progressive training could improve dog performance in sealed-parcel searches. Thirteen operational dog teams participated in trials conducted in Lubbock, Texas, and Miami, Florida. Teams completed a baseline assessment using tape-sealed parcels containing 50 g of C4 or TNT, or distractors, followed by an odor recognition test (ORT) using controlled explosive odor presentations. Following the correction of identified odor-recognition deficiencies, teams completed a training intervention manipulating odor availability through variable parcel venting and requiring progression from odor-source recognition to trained final response. Performance was reassessed using the same parcel configuration. All teams detected C4 during the ORT, whereas only two teams detected TNT. Following intervention, overall sealed-parcel detection sensitivity increased by 35 percentage points (p = 0.0078). C4 detection increased from 38% to 69%, while TNT detection increased from 15% to 54%, although neither individual change reached statistical significance. The results demonstrate that odor recognition does not necessarily translate to effective source localization in sealed parcels and support progressive, operationally representative parcel-search training.
- Open Access
- 28 September 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (10) , 220
Olfactory Signatures of Bladed Weapons: Characterization and Implications for Canine Detection
Knife crime has increased globally, yet the effectiveness of current detection methods used by law enforcement is often limited in operational settings. This challenge highlights the need for innovative detection approaches. The use of canines as highly mobile and sensitive biosensors for the detection of bladed objects may provide an effective and novel solution. A critical step toward implementing canine-based detection is the characterization of the odor signatures associated with bladed objects. Therefore, it is hypothesized that box cutter blades possess a distinct volatile organic compound (VOC) profile that can be differentiated from those of other common metal substrates. To test this hypothesis, headspace extraction and chemical analysis were conducted on box cutter blades of varying sizes, and their VOC profiles were compared with those of metal keys. Five compounds were consistently identified across blade samples and may be considered characteristic odorants of box cutter blades: decanal, eicosane, nonadecane, nonanal, and octadecane. The results suggest that box cutter blades possess detectable and distinguishable VOC profiles that are consistent across different blade sizes. These findings provide foundational data for future odor characterization studies and support the development of canine training aids and detection programs targeting bladed objects.
- 28 September 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (10) , 220
Open AccessOlfactory Signatures of Bladed Weapons: Characterization and Implications for Canine Detection
Knife crime has increased globally, yet the effectiveness of current detection methods used by law enforcement is often limited in operational settings. This challenge highlights the need for innovative detection approaches. The use of canines as highly mobile and sensitive biosensors for the detection of bladed objects may provide an effective and novel solution. A critical step toward implementing canine-based detection is the characterization of the odor signatures associated with bladed objects. Therefore, it is hypothesized that box cutter blades possess a distinct volatile organic compound (VOC) profile that can be differentiated from those of other common metal substrates. To test this hypothesis, headspace extraction and chemical analysis were conducted on box cutter blades of varying sizes, and their VOC profiles were compared with those of metal keys. Five compounds were consistently identified across blade samples and may be considered characteristic odorants of box cutter blades: decanal, eicosane, nonadecane, nonanal, and octadecane. The results suggest that box cutter blades possess detectable and distinguishable VOC profiles that are consistent across different blade sizes. These findings provide foundational data for future odor characterization studies and support the development of canine training aids and detection programs targeting bladed objects.
- Open Access
- 3 August 2026
- Published by Elsevier in Forensic Science International: Synergy
- Vol. 13
Insights from the field: Evaluating handler feedback on training practices and standards on canine detection testing
- 3 August 2026
- Published by Elsevier in Forensic Science International: Synergy
- Vol. 13
Open AccessInsights from the field: Evaluating handler feedback on training practices and standards on canine detection testing
- Open Access
- 11 June 2026
- Published by Elsevier in SSRN Electronic Journal
Development of a C4 odor mimic for explosive-detection canines
One limiting factor in the training and testing of explosives detection canines (EDCs) is the difficulty of obtaining and using explosives. Many legal, practical and financial barriers limit the use of explosives across a wide range of situations. Because of these limitations there has long been interest in non-detonable odor mimics (also called odor simulants or pseudo-odors) of explosives that can be used to test EDCs operational performance. To date, commercially available aids have shown little success since EDCs do not readily respond to them and dogs trained with these aids do not readily respond to actual explosives. We sought to develop mimics using Odor Value Units (OVUs), a methodology from food science that combines volatile headspace analysis with olfactory sensitivity to those volatiles. We used OVUs to develop a series of mimics of C4 variants and tested these with 8 dogs across a series of non-reinforced generalization tests. We found one of these mimics resulted in high generalization upon first exposure, although dogs subsequently learned to discriminate it from live C4. We subsequently tested with operational dogs and found that operational dogs responded to this mimic at rates identical to the live C4, suggesting it can be used to assess operational canines. Our study highlights the importance of integrating chemistry and dog behavior for developing effective explosives training aids.
- 11 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of a C4 odor mimic for explosive-detection canines
One limiting factor in the training and testing of explosives detection canines (EDCs) is the difficulty of obtaining and using explosives. Many legal, practical and financial barriers limit the use of explosives across a wide range of situations. Because of these limitations there has long been interest in non-detonable odor mimics (also called odor simulants or pseudo-odors) of explosives that can be used to test EDCs operational performance. To date, commercially available aids have shown little success since EDCs do not readily respond to them and dogs trained with these aids do not readily respond to actual explosives. We sought to develop mimics using Odor Value Units (OVUs), a methodology from food science that combines volatile headspace analysis with olfactory sensitivity to those volatiles. We used OVUs to develop a series of mimics of C4 variants and tested these with 8 dogs across a series of non-reinforced generalization tests. We found one of these mimics resulted in high generalization upon first exposure, although dogs subsequently learned to discriminate it from live C4. We subsequently tested with operational dogs and found that operational dogs responded to this mimic at rates identical to the live C4, suggesting it can be used to assess operational canines. Our study highlights the importance of integrating chemistry and dog behavior for developing effective explosives training aids.
- Open Access
- 25 February 2026
- Published by MDPI AG in Appliedchem
- Vol. 6 (1) , 13
Using Chromatographic Methods to Assess the Stability of Decomposition Training Aids Under Freezing Storage Conditions for Canine Training Applications
Human remains detection (HRD) canines are a class of odor detection canines trained with training aids representative of distinctive stages of putrefaction. This is necessary for canines to detect the whole spectrum of decomposition products, which is encountered in operational deployments. Understanding the definition of the cadaveric profile can help better train canine detection teams and assist with technological developments. This study aimed to (1) monitor chemical odor profiles utilizing two containment vessels, and (2) monitor two preservation methods on chemical odor profile changes as a function of freezing to thawing cycles. Instrumental analysis used solid phase microextraction- gas chromatography/mass spectrometry (SPME-GC/MS) for identification of volatile organic compounds (VOCs) from tissue/bone samples of pig carcasses at various decomposition stages. Samples were analyzed weekly for six (6) weeks to monitor chemical odor profiles as a function of time. Clear vials provided slightly better storage stability for the fresh stage compared to amber vials. However, amber vials were more suitable for the advanced decay and skeletal stages, helping to preserve the chemical odor profile. Regarding the preservation methods, a continuous preservation method portrayed better reproducibility of the original odor profile throughout the 6-week period, as depicted from higher Spearman correlation values. This study is the first to explore simulated training aids under freezing conditions, uncovering the dynamic and complex nature of odor over time. The results highlight that understanding these shifting odor profiles is essential for canine handlers aiming to optimize the realism and effectiveness of maintenance training.
- 25 February 2026
- Published by MDPI AG in Appliedchem
- Vol. 6 (1) , 13
Open AccessUsing Chromatographic Methods to Assess the Stability of Decomposition Training Aids Under Freezing Storage Conditions for Canine Training Applications
Human remains detection (HRD) canines are a class of odor detection canines trained with training aids representative of distinctive stages of putrefaction. This is necessary for canines to detect the whole spectrum of decomposition products, which is encountered in operational deployments. Understanding the definition of the cadaveric profile can help better train canine detection teams and assist with technological developments. This study aimed to (1) monitor chemical odor profiles utilizing two containment vessels, and (2) monitor two preservation methods on chemical odor profile changes as a function of freezing to thawing cycles. Instrumental analysis used solid phase microextraction- gas chromatography/mass spectrometry (SPME-GC/MS) for identification of volatile organic compounds (VOCs) from tissue/bone samples of pig carcasses at various decomposition stages. Samples were analyzed weekly for six (6) weeks to monitor chemical odor profiles as a function of time. Clear vials provided slightly better storage stability for the fresh stage compared to amber vials. However, amber vials were more suitable for the advanced decay and skeletal stages, helping to preserve the chemical odor profile. Regarding the preservation methods, a continuous preservation method portrayed better reproducibility of the original odor profile throughout the 6-week period, as depicted from higher Spearman correlation values. This study is the first to explore simulated training aids under freezing conditions, uncovering the dynamic and complex nature of odor over time. The results highlight that understanding these shifting odor profiles is essential for canine handlers aiming to optimize the realism and effectiveness of maintenance training.
- Open Access
- 11 February 2026
- Published by MDPI AG in Separations
- Vol. 13 (2) , 64
Evaluation of Blood Odor Signatures from Cadaveric Origin
Blood is a key biological specimen in forensic analysis for both living and deceased individuals, playing a crucial role in drug testing, blood typing, DNA analysis, and bloodstain pattern examination. In forensics, the decomposition of blood holds particular importance because it is a major biological fluid in the human body and undergoes early chemical changes that attract insects and microorganisms to cadaveric sources. The odor signatures produced during the putrefactive process have recently gained forensic relevance, prompting studies to investigate volatile organic compounds (VOCs) from blood, tissues, animal proxies, and human cadavers to enhance human remains detection and recovery via technological or biological means. This study focuses on cadaveric blood odor profiling, evaluating VOC signatures from human cadavers in an anatomy laboratory using solid-phase micro-extraction (SPME) and gas chromatography–mass spectrometry (GC/MS) upon body receipt. A second phase entailed a degradation analysis using 7 human cadavers and a total of 28 postmortem samples repeatedly sampled over a 4-week period. The findings revealed an increasingly complex odor profile as decomposition progresses, with a notable rise in both the variety and concentration of VOCs. Room temperature samples exhibited a more diverse and rapid VOC release, while refrigerated samples showed slower degradation. These insights contribute to a deeper understanding of decomposition patterns and ultimately refine human remains detection methodologies.
- 11 February 2026
- Published by MDPI AG in Separations
- Vol. 13 (2) , 64
Open AccessEvaluation of Blood Odor Signatures from Cadaveric Origin
Blood is a key biological specimen in forensic analysis for both living and deceased individuals, playing a crucial role in drug testing, blood typing, DNA analysis, and bloodstain pattern examination. In forensics, the decomposition of blood holds particular importance because it is a major biological fluid in the human body and undergoes early chemical changes that attract insects and microorganisms to cadaveric sources. The odor signatures produced during the putrefactive process have recently gained forensic relevance, prompting studies to investigate volatile organic compounds (VOCs) from blood, tissues, animal proxies, and human cadavers to enhance human remains detection and recovery via technological or biological means. This study focuses on cadaveric blood odor profiling, evaluating VOC signatures from human cadavers in an anatomy laboratory using solid-phase micro-extraction (SPME) and gas chromatography–mass spectrometry (GC/MS) upon body receipt. A second phase entailed a degradation analysis using 7 human cadavers and a total of 28 postmortem samples repeatedly sampled over a 4-week period. The findings revealed an increasingly complex odor profile as decomposition progresses, with a notable rise in both the variety and concentration of VOCs. Room temperature samples exhibited a more diverse and rapid VOC release, while refrigerated samples showed slower degradation. These insights contribute to a deeper understanding of decomposition patterns and ultimately refine human remains detection methodologies.
- Open Access
- 16 October 2025
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 12, 1668317
Explosive detection canines in the field: a multi-site black box validation study
In 2009, the National Research Council called upon the forensic science community to standardize the best practices and guidelines in the collection and analysis of evidence with the goal of ensuring quality and consistency within the field. In response to this need, the Organization of Scientific Area Committees for Forensic Science (OSAC) was established to coordinate the development of best practices and standards in the forensic sciences. The OSAC Dogs and Sensors subcommittee was part of this initiative focusing on standardizing training and certification protocols for canine detection teams. Though efforts to create and promote such standards are ongoing worldwide, the developed assessments for both training and operational contexts have yet to be empirically validated. As a first step toward addressing this gap, a proof-of-concept black box study was carried out to assess the OSAC explosive canine detection standard based on performance of explosive detection canines. The evaluations were held in three separate geographic locations with a total of 56 canine/handler teams, took place over 2 days, and included searches recommended within the ANSI/ASB Standard 092 as well as scenarios designed to more closely mimic what the teams might experience in practice. Overall, the results from the individual canine/handler team responses revealed that no team would have passed the OSAC certification; however, the results indicated comparable performance on both assessment types (standard assessments and operational scenarios). Additionally, canine/handler performance varied significantly across all three trials in both correct alert, false alert rates, and detection success rate across the mandatory six different explosive types presented. These findings suggest that the performance on Standard 092 certification assessments may predict operational effectiveness. The results also suggest that the variation in performance is attributable to the diversity of training aid material routinely available to the participating teams.
- 16 October 2025
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 12, 1668317
Open AccessExplosive detection canines in the field: a multi-site black box validation study
In 2009, the National Research Council called upon the forensic science community to standardize the best practices and guidelines in the collection and analysis of evidence with the goal of ensuring quality and consistency within the field. In response to this need, the Organization of Scientific Area Committees for Forensic Science (OSAC) was established to coordinate the development of best practices and standards in the forensic sciences. The OSAC Dogs and Sensors subcommittee was part of this initiative focusing on standardizing training and certification protocols for canine detection teams. Though efforts to create and promote such standards are ongoing worldwide, the developed assessments for both training and operational contexts have yet to be empirically validated. As a first step toward addressing this gap, a proof-of-concept black box study was carried out to assess the OSAC explosive canine detection standard based on performance of explosive detection canines. The evaluations were held in three separate geographic locations with a total of 56 canine/handler teams, took place over 2 days, and included searches recommended within the ANSI/ASB Standard 092 as well as scenarios designed to more closely mimic what the teams might experience in practice. Overall, the results from the individual canine/handler team responses revealed that no team would have passed the OSAC certification; however, the results indicated comparable performance on both assessment types (standard assessments and operational scenarios). Additionally, canine/handler performance varied significantly across all three trials in both correct alert, false alert rates, and detection success rate across the mandatory six different explosive types presented. These findings suggest that the performance on Standard 092 certification assessments may predict operational effectiveness. The results also suggest that the variation in performance is attributable to the diversity of training aid material routinely available to the participating teams.
- Open Access
The Chemical Fingerprint of Smokeless Powders: Insights from Headspace Odor Volatiles
Smokeless powders are a commonly used low explosive within the ammunition industry. Their ease of purchase has allowed criminals to use these products to build improvised explosive devices. Canines have become a vital tool in locating such improvised devices. With differing fabrication processes, one of the most difficult challenges for canine handlers is the optimal selection of training aids to choose as odor targets to allow for broad generalization. Several studies have been underway to understand the chemical odor characterization of smokeless powders, which can help provide canine teams with essential information to understand odor signatures from powder varieties. In this study, a SPME method optimization was conducted using unburned smokeless powders to provide a chemical odor profile assessment. Concurrently, statistical analysis using PCA and Spearman’s rank correlations was performed to explore whether odor volatile composition depicted associations between and within powder brands. The results showed that a longer extraction time (24 h) was optimal across all powders, as this yielded higher compound abundance and number of extracted odor volatiles. The optimal SPME fiber varied per powder, depicting the complexity of powder composition. There were 66 highly frequent compounds among the 18 powders, including 2-ethyl-1-hexanol, diphenylamine (DPA), and dibutyl phthalate. Principal component analysis (PCA) showed that while powders may be of the same type (single/double base), they can still portray clustering differences across and within brands. The Spearman’s rank correlation within powder type suggested that the double-base powders had a slightly higher similarity index when compared with the single-base powder types. Understanding the volatile odor profiles of various smokeless powders can enhance canine training by informing the selection of effective training aids and supporting odor generalization.
Open AccessThe Chemical Fingerprint of Smokeless Powders: Insights from Headspace Odor Volatiles
Smokeless powders are a commonly used low explosive within the ammunition industry. Their ease of purchase has allowed criminals to use these products to build improvised explosive devices. Canines have become a vital tool in locating such improvised devices. With differing fabrication processes, one of the most difficult challenges for canine handlers is the optimal selection of training aids to choose as odor targets to allow for broad generalization. Several studies have been underway to understand the chemical odor characterization of smokeless powders, which can help provide canine teams with essential information to understand odor signatures from powder varieties. In this study, a SPME method optimization was conducted using unburned smokeless powders to provide a chemical odor profile assessment. Concurrently, statistical analysis using PCA and Spearman’s rank correlations was performed to explore whether odor volatile composition depicted associations between and within powder brands. The results showed that a longer extraction time (24 h) was optimal across all powders, as this yielded higher compound abundance and number of extracted odor volatiles. The optimal SPME fiber varied per powder, depicting the complexity of powder composition. There were 66 highly frequent compounds among the 18 powders, including 2-ethyl-1-hexanol, diphenylamine (DPA), and dibutyl phthalate. Principal component analysis (PCA) showed that while powders may be of the same type (single/double base), they can still portray clustering differences across and within brands. The Spearman’s rank correlation within powder type suggested that the double-base powders had a slightly higher similarity index when compared with the single-base powder types. Understanding the volatile odor profiles of various smokeless powders can enhance canine training by informing the selection of effective training aids and supporting odor generalization.
- Open Access
- 14 May 2025
- Published by MDPI AG in Forensic Sciences
- Vol. 5 (2) , 21
The Impact of Entomological Sample Handling Techniques on a Single Larva Odor Profile
Background: Chemical odor profiling within forensic entomology is an emerging tool given its potential for species identification and larval aging and its ability to identify decomposition stages. A volatile analysis of larval masses across species of distinctive developmental stages was carried out with extraction techniques to identify odor signatures. However, it is unknown how larval sample handling (i.e., live samples in research vs. hot-water-killed samples in casework) affects odor signatures or the possibility of obtaining relevant volatiles from a single larva. Method: This study utilized solid-phase microextraction (SPME) with gas chromatography–mass spectrometry (GC/MS) for the analysis of odor volatiles emanating from single larval samples of Cochliomyia macellaria. Fifty (50) larvae (25 live; 25 boiled) were analyzed. Results: The SPME-GC/MS method allowed for odor volatile detection from a single maggot regardless of the sample handling group. The main compounds identified across both groups included those previously reported as emanating from larvae and decomposition substrates. When comparing treatments, the boiled larval samples had a 6-fold decrease in compound abundance compared to the live samples. The identified odor volatiles observed in the hot-water-killed treatment group included indole, p-cresol, and phenol. Conclusions: These results suggest that the handling technique impacts odor detection. Additionally, the heterocyclic aromatics and alcohols identified in the boiled samples are potentially odor markers of a higher intrinsic nature to the maggot rather than a cross-transfer from the decomposition substrate given their survival post elevated temperature treatment. This work shows the plausibility of carrying out an odor analysis of a single maggot following both common research and casework handling practices.
- 14 May 2025
- Published by MDPI AG in Forensic Sciences
- Vol. 5 (2) , 21
Open AccessThe Impact of Entomological Sample Handling Techniques on a Single Larva Odor Profile
Background: Chemical odor profiling within forensic entomology is an emerging tool given its potential for species identification and larval aging and its ability to identify decomposition stages. A volatile analysis of larval masses across species of distinctive developmental stages was carried out with extraction techniques to identify odor signatures. However, it is unknown how larval sample handling (i.e., live samples in research vs. hot-water-killed samples in casework) affects odor signatures or the possibility of obtaining relevant volatiles from a single larva. Method: This study utilized solid-phase microextraction (SPME) with gas chromatography–mass spectrometry (GC/MS) for the analysis of odor volatiles emanating from single larval samples of Cochliomyia macellaria. Fifty (50) larvae (25 live; 25 boiled) were analyzed. Results: The SPME-GC/MS method allowed for odor volatile detection from a single maggot regardless of the sample handling group. The main compounds identified across both groups included those previously reported as emanating from larvae and decomposition substrates. When comparing treatments, the boiled larval samples had a 6-fold decrease in compound abundance compared to the live samples. The identified odor volatiles observed in the hot-water-killed treatment group included indole, p-cresol, and phenol. Conclusions: These results suggest that the handling technique impacts odor detection. Additionally, the heterocyclic aromatics and alcohols identified in the boiled samples are potentially odor markers of a higher intrinsic nature to the maggot rather than a cross-transfer from the decomposition substrate given their survival post elevated temperature treatment. This work shows the plausibility of carrying out an odor analysis of a single maggot following both common research and casework handling practices.
- Open Access
Evaluation of Volatile Organic Compounds from Spotted Lanternfly (Lycorma delicatula) Eggs Using Headspace Odor Sampling Methods
The spotted lanternfly (SLF) is an invasive species native to China. It was first discovered in the United States in Pennsylvania in 2014. It is known to cause great economic damage by destroying various crops, specifically grape vines, and therefore, several efforts have been made to control and mitigate its spread from the Northeast. Canine detection is a useful detection tool; however, it is crucial to understand the volatile organic compounds emitting by this pest to better direct canine training paradigms to prevent false alerts and to understand potential volatile markers of importance indicative of this species. The purpose of this study is to address the gap in research regarding the volatile organic compound (VOC) profile of SLF to better inform pest control mitigation strategies. Instrumental analysis was performed utilizing SPME-GC/MS on cold-killed SLF eggs, dried crickets, and tree bark. Differences in detected VOCs within each sample set depicted distinctive odor profiles for each matrix tested. Storage of these samples also depicted VOC accumulation variation as a function of time, thereby providing implications for long-term storage and sample handling for these types of training aids in canine applications.
Open AccessEvaluation of Volatile Organic Compounds from Spotted Lanternfly (Lycorma delicatula) Eggs Using Headspace Odor Sampling Methods
The spotted lanternfly (SLF) is an invasive species native to China. It was first discovered in the United States in Pennsylvania in 2014. It is known to cause great economic damage by destroying various crops, specifically grape vines, and therefore, several efforts have been made to control and mitigate its spread from the Northeast. Canine detection is a useful detection tool; however, it is crucial to understand the volatile organic compounds emitting by this pest to better direct canine training paradigms to prevent false alerts and to understand potential volatile markers of importance indicative of this species. The purpose of this study is to address the gap in research regarding the volatile organic compound (VOC) profile of SLF to better inform pest control mitigation strategies. Instrumental analysis was performed utilizing SPME-GC/MS on cold-killed SLF eggs, dried crickets, and tree bark. Differences in detected VOCs within each sample set depicted distinctive odor profiles for each matrix tested. Storage of these samples also depicted VOC accumulation variation as a function of time, thereby providing implications for long-term storage and sample handling for these types of training aids in canine applications.