Naoki Nagasawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Naoki Nagasawa has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Satoshi Nakamura
Department of Advanced Diagnostic Imaging, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu 514-8507, Mie, Japan
4 shared publications - Hajime Sakuma
Department of Radiology, Mie University Graduate School of Medicine, Tsu, Japan
3 shared publications - Kakuya Kitagawa
Department of Radiology, Mie University Hospital, Tsu 514-8507, Japan
3 shared publications Akio Yamazaki
Department of Radiology, Mie University Hospital, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan
2 shared publications- Masafumi Takafuji
Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds LS2 9JT, UK
2 shared publications - Masaki Ishida
Department of Radiology, Mie University Hospital, Tsu, Mie, Japan
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (4) , 354-364
Biventricular and biatrial assessment using low-dose cine computed tomography during recirculation phase of contrast agent: Comparison to cine cardiac magnetic resonance
- 1 May 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (4) , 354-364
Open AccessBiventricular and biatrial assessment using low-dose cine computed tomography during recirculation phase of contrast agent: Comparison to cine cardiac magnetic resonance
- 16 January 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (2) , 185-189
A novel pendulum-based impulse method to measure CT temporal resolution
- 16 January 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (2) , 185-189
A novel pendulum-based impulse method to measure CT temporal resolution
- 21 March 2023
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (4) , 1578-1587
Application of Deep Learning-Based Denoising Technique for Radiation Dose Reduction in Dynamic Abdominal CT: Comparison with Standard-Dose CT Using Hybrid Iterative Reconstruction Method
The purpose is to evaluate whether deep learning-based denoising (DLD) algorithm provides sufficient image quality for abdominal computed tomography (CT) with a 30% reduction in radiation dose, compared to standard-dose CT reconstructed with conventional hybrid iterative reconstruction (IR). The subjects consisted of 50 patients who underwent abdominal CT with standard dose and reconstructed with hybrid IR (ASiR-V50%) and another 50 patients who underwent abdominal CT with approximately 30% less dose and reconstructed with ASiR-V50% and DLD at low-, medium- and high-strength (DLD-L, DLD-M and DLD-H, respectively). The standard deviation of attenuation in liver parenchyma was measured as image noise. Contrast-to-noise ratio (CNR) for portal vein on portal venous phase was calculated. Lesion conspicuity in 23 abdominal solid mass on the reduced-dose CT was rated on a 5-point scale: 0 (best) to −4 (markedly inferior). Compared with hybrid IR of standard-dose CT, DLD-H of reduced-dose CT provided significantly lower image noise (portal phase: 9.0 (interquartile range, 8.7–9.4) HU vs 12.0 (11.4–12.7) HU, P < 0.0001) and significantly higher CNR (median, 5.8 (4.4–7.4) vs 4.3 (3.3–5.3), P = 0.0019). As for DLD-M of reduced-dose CT, no significant difference was found in image noise and CNR compared to hybrid IR of standard-dose CT (P > 0.99). Lesion conspicuity scores for DLD-H and DLD-M were significantly better than hybrid IR (P < 0.05). Dynamic contrast-enhanced abdominal CT acquired with approximately 30% lower radiation dose and generated with the DLD algorithm exhibit lower image noise and higher CNR compared to standard-dose CT with hybrid IR.
- 21 March 2023
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (4) , 1578-1587
Application of Deep Learning-Based Denoising Technique for Radiation Dose Reduction in Dynamic Abdominal CT: Comparison with Standard-Dose CT Using Hybrid Iterative Reconstruction Method
The purpose is to evaluate whether deep learning-based denoising (DLD) algorithm provides sufficient image quality for abdominal computed tomography (CT) with a 30% reduction in radiation dose, compared to standard-dose CT reconstructed with conventional hybrid iterative reconstruction (IR). The subjects consisted of 50 patients who underwent abdominal CT with standard dose and reconstructed with hybrid IR (ASiR-V50%) and another 50 patients who underwent abdominal CT with approximately 30% less dose and reconstructed with ASiR-V50% and DLD at low-, medium- and high-strength (DLD-L, DLD-M and DLD-H, respectively). The standard deviation of attenuation in liver parenchyma was measured as image noise. Contrast-to-noise ratio (CNR) for portal vein on portal venous phase was calculated. Lesion conspicuity in 23 abdominal solid mass on the reduced-dose CT was rated on a 5-point scale: 0 (best) to −4 (markedly inferior). Compared with hybrid IR of standard-dose CT, DLD-H of reduced-dose CT provided significantly lower image noise (portal phase: 9.0 (interquartile range, 8.7–9.4) HU vs 12.0 (11.4–12.7) HU, P < 0.0001) and significantly higher CNR (median, 5.8 (4.4–7.4) vs 4.3 (3.3–5.3), P = 0.0019). As for DLD-M of reduced-dose CT, no significant difference was found in image noise and CNR compared to hybrid IR of standard-dose CT (P > 0.99). Lesion conspicuity scores for DLD-H and DLD-M were significantly better than hybrid IR (P < 0.05). Dynamic contrast-enhanced abdominal CT acquired with approximately 30% lower radiation dose and generated with the DLD algorithm exhibit lower image noise and higher CNR compared to standard-dose CT with hybrid IR.
- 1 August 2021
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 14 (8) , 1674-1675
Prognostic Value of Cardiac CT Delayed Enhancement Imaging in Patients With Suspected Coronary Artery Disease
- 1 August 2021
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 14 (8) , 1674-1675
Prognostic Value of Cardiac CT Delayed Enhancement Imaging in Patients With Suspected Coronary Artery Disease
- Open Access
- 1 January 2020
- Published by XMLink in Korean Journal of Radiology
- Vol. 21 (1) , 58-67
Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT
Takafuji M, et al. Korean J Radiol. 2019 Oct;20:e90. https://doi.org/10.3348/kjr.2019.0323
- 1 January 2020
- Published by XMLink in Korean Journal of Radiology
- Vol. 21 (1) , 58-67
Open AccessMyocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT
Takafuji M, et al. Korean J Radiol. 2019 Oct;20:e90. https://doi.org/10.3348/kjr.2019.0323