Hongyu Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hongyu Wei has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Chunke Dong
Beijing Hospital of Traditional Chinese Medicine, Capital Medical University, Beijing, China
7 shared publications Yuting Zhu
Beijing Tongzhou Integrative Medicine Hospital, Beijing, China
6 shared publicationsHaoning Ma
Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, 100029, People’s Republic of China
5 shared publicationsChunke Dong
Department of Orthopedics, Beijing Hospital of Traditional Chinese Medicine, Capital Medical University, Beijing, China
4 shared publicationsJun Zhou
Centre of Acupuncture and Moxibustion, Beijing Hospital of Traditional Chinese Medicine, Capital Medical University, Beijing, China
4 shared publications- Mingsheng Tan
Department of Orthopaedics
3 shared publications
Latest Publications
- Open Access
- 8 July 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Three-dimensional printed artificial vertebral body versus titanium mesh cage and nanohydroxyapatite/polyamide-66 cage in anterior cervical corpectomy and fusion: a retrospective cohort study with a minimum 5-year follow-up
Anterior cervical corpectomy and fusion (ACCF) is a commonly performed procedure for cervical spondylotic myelopathy (CSM) and ossification of the posterio
- 8 July 2026
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 21 (1)
Open AccessThree-dimensional printed artificial vertebral body versus titanium mesh cage and nanohydroxyapatite/polyamide-66 cage in anterior cervical corpectomy and fusion: a retrospective cohort study with a minimum 5-year follow-up
Anterior cervical corpectomy and fusion (ACCF) is a commonly performed procedure for cervical spondylotic myelopathy (CSM) and ossification of the posterio
- Top Cited PapersOpen Access
- 29 August 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-16
Evidence on risk factors for knee osteoarthritis in middle-older aged: a systematic review and meta analysis
Purpose: This review was made to identify the risk factors for knee osteoarthritis (KOA) in middle-older aged (≥ 40 years), and to provide the newest evidence for the prevention of KOA. Method: Cohort study and case–control study of the risk factors of KOA was included from Pubmed, Web of Science, Ovid Technologies, China National Knowledge Infrastructure (CNKI), Chinese Science and Technology Periodical Database (VIP), Wanfang Database, SinoMed from their inceptions to July 2023. Two authors independently screened the literature and extracted data. Assessment of quality was implemented according to Agency for Healthcare Research and Quality (AHRQ) and Newcastle–Ottawa Quality Assessment Scale. Meta-analysis was performed using RevMan 5.3 software. Results: 3597 papers were identified from the seven databases and 29 papers containing 60,354 participants were included in this review. Meta-analysis was performed for 14 risk factors, and 7 of these were statistical significance (P < 0.05). The risk factors which were analyzed in this review included trauma history in knee (1.37 [95% CI 1.03–1.82], P = 0.030), body mass index (BMI) ≥ 24 kg/m2 (1.30 [95% CI 1.09–1.56], P = 0.004), gender (female) (1.04 [95% CI 1.00–1.09], P = 0.030), age ≥ 40 (1.02 [95% CI 1.01–1.03], P = 0.007), more exercise (0.75 [95% CI 0.62–0.91], P = 0.003), a high school education background (0.49 [95% CI 0.30–0.79], P = 0.003) and an university education background (0.22 [95% CI 0.06–0.86], P = 0.030). Conclusion: The risk factors analyzed in this review included trauma history in knee, overweight or obesity, gender (female), age ≥ 40 and the protective factors included more exercise and a high school or an university education background.
- 29 August 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-16
Top Cited PapersOpen AccessEvidence on risk factors for knee osteoarthritis in middle-older aged: a systematic review and meta analysis
Purpose: This review was made to identify the risk factors for knee osteoarthritis (KOA) in middle-older aged (≥ 40 years), and to provide the newest evidence for the prevention of KOA. Method: Cohort study and case–control study of the risk factors of KOA was included from Pubmed, Web of Science, Ovid Technologies, China National Knowledge Infrastructure (CNKI), Chinese Science and Technology Periodical Database (VIP), Wanfang Database, SinoMed from their inceptions to July 2023. Two authors independently screened the literature and extracted data. Assessment of quality was implemented according to Agency for Healthcare Research and Quality (AHRQ) and Newcastle–Ottawa Quality Assessment Scale. Meta-analysis was performed using RevMan 5.3 software. Results: 3597 papers were identified from the seven databases and 29 papers containing 60,354 participants were included in this review. Meta-analysis was performed for 14 risk factors, and 7 of these were statistical significance (P < 0.05). The risk factors which were analyzed in this review included trauma history in knee (1.37 [95% CI 1.03–1.82], P = 0.030), body mass index (BMI) ≥ 24 kg/m2 (1.30 [95% CI 1.09–1.56], P = 0.004), gender (female) (1.04 [95% CI 1.00–1.09], P = 0.030), age ≥ 40 (1.02 [95% CI 1.01–1.03], P = 0.007), more exercise (0.75 [95% CI 0.62–0.91], P = 0.003), a high school education background (0.49 [95% CI 0.30–0.79], P = 0.003) and an university education background (0.22 [95% CI 0.06–0.86], P = 0.030). Conclusion: The risk factors analyzed in this review included trauma history in knee, overweight or obesity, gender (female), age ≥ 40 and the protective factors included more exercise and a high school or an university education background.
- Open Access
- 1 July 2021
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 16, 1403-1413
A Minimally Invasive Technique Using Cortical Bone Trajectory Screws Assisted by 3D-Printed Navigation Templates in Lumbar Adjacent Segment Degeneration
Purpose: Revision surgery for adjacent segment degeneration (ASD) commonly requires exposing and removing the original fixation. To minimize trauma and to reduce the operation time and blood loss, we introduced a minimally invasive lumbar revision technique using cortical bone trajectory (CBT) screws assisted by three-dimensional (3D)-printed navigation templates. Methods: From April 2017 to October 2019, 18 patients with ASD underwent revision surgery with CBT screws assisted by 3D-printed templates in our hospital. All surgical data, including the operation time, blood loss, and incision length, were recorded. We evaluated the clinical efficacy using the visual analog scale (VAS), the Oswestry Disability Index (ODI), and the Japanese Orthopedic Association (JOA) score. X-ray and computed tomography (CT) scans were used to evaluate the stability of CBT screw fixation, the accuracy of screws, and the fusion rate. Results: The mean follow-up was 22.4± 4.7 months (12– 31 months). The VAS, ODI, and JOA scores were analyzed by SPSS 21.0 and showed significant improvement at 2 weeks and the last follow-up compared with preoperative data (P< 0.05). Seventy-six CBT screws were inserted with navigation templates; 2 screws were Grade B, and the other screws were Grade 0 or A. Changes in intervertebral height showed good stability of CBT screw fixation (P> 0.05). All the patients exhibited satisfactory fusion results. Conclusion: Revision surgery for ASD with CBT screws assisted by 3D-printed navigation templates has satisfactory clinical efficacy with the advantages of a short operation time, a small incision, and less blood loss.
- 1 July 2021
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 16, 1403-1413
Open AccessA Minimally Invasive Technique Using Cortical Bone Trajectory Screws Assisted by 3D-Printed Navigation Templates in Lumbar Adjacent Segment Degeneration
Purpose: Revision surgery for adjacent segment degeneration (ASD) commonly requires exposing and removing the original fixation. To minimize trauma and to reduce the operation time and blood loss, we introduced a minimally invasive lumbar revision technique using cortical bone trajectory (CBT) screws assisted by three-dimensional (3D)-printed navigation templates. Methods: From April 2017 to October 2019, 18 patients with ASD underwent revision surgery with CBT screws assisted by 3D-printed templates in our hospital. All surgical data, including the operation time, blood loss, and incision length, were recorded. We evaluated the clinical efficacy using the visual analog scale (VAS), the Oswestry Disability Index (ODI), and the Japanese Orthopedic Association (JOA) score. X-ray and computed tomography (CT) scans were used to evaluate the stability of CBT screw fixation, the accuracy of screws, and the fusion rate. Results: The mean follow-up was 22.4± 4.7 months (12– 31 months). The VAS, ODI, and JOA scores were analyzed by SPSS 21.0 and showed significant improvement at 2 weeks and the last follow-up compared with preoperative data (P< 0.05). Seventy-six CBT screws were inserted with navigation templates; 2 screws were Grade B, and the other screws were Grade 0 or A. Changes in intervertebral height showed good stability of CBT screw fixation (P> 0.05). All the patients exhibited satisfactory fusion results. Conclusion: Revision surgery for ASD with CBT screws assisted by 3D-printed navigation templates has satisfactory clinical efficacy with the advantages of a short operation time, a small incision, and less blood loss.
- 6 June 2021
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 35 (11) , 1506-1517
Ultrasound-guided local corticosteroid injection for carpal tunnel syndrome: A meta-analysis of randomized controlled trials
This meta-analysis aimed to compare the efficacy and safety of ultrasound-guided (US-guided) versus landmark-guided (LM-guided) local corticosteroid injection for carpal tunnel syndrome (CTS). Database including Pubmed, Embase, and Cochrane Library were searched to identify relevant randomized controlled trials (RCTs). The outcomes mainly included Boston Carpal Tunnel Questionnaire (BCTQ): Symptom Severity Scale (BCTQs), Functional Status Scale (BCTQf); and electrophysiological indexes: distal motor latency (DML), sensory distal latency (SDL), compound muscle action potential (CAMP), sensory nerve action potential amplitude (SNAP), and sensory nerve conduction velocity (SNCV). Adverse events were also recorded. Overall, nine RCTs were finally screened out with 469 patients (596 injected hands). Pooled analysis showed that US-guided injection was more effective in BCTQs (SMD, −0.69; 95% CI, −1.08 to −0.31; P = 0.0005), BCTQf (SMD, −0.23; 95% CI, −0.39 to −0.07; P = 0.005), CAMP (MD, 0.64; 95% CI, 0.35−0.94; P < 0.0001) improvement, and a lower rate of adverse events (RR, 0.34; 95% CI, 0.22−0.52; P < 0.00001). Subgroup analysis revealed that the US-guided injection had significantly better CMAP than the LM-guided for the in-plane approach (MD, 0.69; 95% CI, 0.36−1.01; P < 0.0001) but not for the out-plane approach (MD, 0.39; 95% CI, −0.39 to 1.17; P = 0.33). US-guided injection was superior to LM-guided injection in symptom severity, functional status, electrodiagnostic, and adverse events improvement for CTS. To some extent, the in-plane approach yields better results compared with the out-plane process under US guidance.
- 6 June 2021
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 35 (11) , 1506-1517
Ultrasound-guided local corticosteroid injection for carpal tunnel syndrome: A meta-analysis of randomized controlled trials
This meta-analysis aimed to compare the efficacy and safety of ultrasound-guided (US-guided) versus landmark-guided (LM-guided) local corticosteroid injection for carpal tunnel syndrome (CTS). Database including Pubmed, Embase, and Cochrane Library were searched to identify relevant randomized controlled trials (RCTs). The outcomes mainly included Boston Carpal Tunnel Questionnaire (BCTQ): Symptom Severity Scale (BCTQs), Functional Status Scale (BCTQf); and electrophysiological indexes: distal motor latency (DML), sensory distal latency (SDL), compound muscle action potential (CAMP), sensory nerve action potential amplitude (SNAP), and sensory nerve conduction velocity (SNCV). Adverse events were also recorded. Overall, nine RCTs were finally screened out with 469 patients (596 injected hands). Pooled analysis showed that US-guided injection was more effective in BCTQs (SMD, −0.69; 95% CI, −1.08 to −0.31; P = 0.0005), BCTQf (SMD, −0.23; 95% CI, −0.39 to −0.07; P = 0.005), CAMP (MD, 0.64; 95% CI, 0.35−0.94; P < 0.0001) improvement, and a lower rate of adverse events (RR, 0.34; 95% CI, 0.22−0.52; P < 0.00001). Subgroup analysis revealed that the US-guided injection had significantly better CMAP than the LM-guided for the in-plane approach (MD, 0.69; 95% CI, 0.36−1.01; P < 0.0001) but not for the out-plane approach (MD, 0.39; 95% CI, −0.39 to 1.17; P = 0.33). US-guided injection was superior to LM-guided injection in symptom severity, functional status, electrodiagnostic, and adverse events improvement for CTS. To some extent, the in-plane approach yields better results compared with the out-plane process under US guidance.
- Open Access
- 1 December 2020
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 15, 2265-2276
Application of Titanium Alloy 3D-Printed Artificial Vertebral Body for Stage III Kümmell’s Disease Complicated by Neurological Deficits
Purpose: The current study aimed to compare the clinical and radiographic results of the 3D-printed artificial vertebral body (3DP-AVB) and titanium mesh cage (TMC) for the treatment of Kümmell’s disease (KD) complicated by neurological deficits. Patients and Methods: From January 2014 to July 2018, 28 consecutive patients diagnosed with KD and nerve injuries in our department were treated by posterior vertebral column resection and internal fixation. The patients were divided into two groups (3DP-AVB group and TMC group) based on the different anterior column reconstruction implants. Clinical and radiographic parameters were used to evaluate the outcomes. Results: The two groups achieved excellent clinical and radiographic results 1 month after surgery with no significant difference (P> 0.05), while 3DP-AVB group showed better outcomes compared with TMC group during the follow-up after 6 months (P< 0.05). The risk of subsidence in 3DP-AVB group was lower than that in TMC group (41.6% vs 87.5%, P< 0.05), and severe subsidence (≥ 5 mm) was correlated with the recurrence of back pain and bad daily life function. No significant difference was found in the improvement of neurological function between the two groups (P> 0.05). The blood loss and operation time in 3DP-AVB group were significantly less than both in TMC group (P< 0.05). Conclusion: The lower incidence of cage subsidence, with a better long-term efficacy in maintaining the height of the fused segment, relieving back pain, and improving daily life function indicates that the 3DP-AVB may be a superior alternative for KD with neurological deficits.
- 1 December 2020
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. ume 15, 2265-2276
Open AccessApplication of Titanium Alloy 3D-Printed Artificial Vertebral Body for Stage III Kümmell’s Disease Complicated by Neurological Deficits
Purpose: The current study aimed to compare the clinical and radiographic results of the 3D-printed artificial vertebral body (3DP-AVB) and titanium mesh cage (TMC) for the treatment of Kümmell’s disease (KD) complicated by neurological deficits. Patients and Methods: From January 2014 to July 2018, 28 consecutive patients diagnosed with KD and nerve injuries in our department were treated by posterior vertebral column resection and internal fixation. The patients were divided into two groups (3DP-AVB group and TMC group) based on the different anterior column reconstruction implants. Clinical and radiographic parameters were used to evaluate the outcomes. Results: The two groups achieved excellent clinical and radiographic results 1 month after surgery with no significant difference (P> 0.05), while 3DP-AVB group showed better outcomes compared with TMC group during the follow-up after 6 months (P< 0.05). The risk of subsidence in 3DP-AVB group was lower than that in TMC group (41.6% vs 87.5%, P< 0.05), and severe subsidence (≥ 5 mm) was correlated with the recurrence of back pain and bad daily life function. No significant difference was found in the improvement of neurological function between the two groups (P> 0.05). The blood loss and operation time in 3DP-AVB group were significantly less than both in TMC group (P< 0.05). Conclusion: The lower incidence of cage subsidence, with a better long-term efficacy in maintaining the height of the fused segment, relieving back pain, and improving daily life function indicates that the 3DP-AVB may be a superior alternative for KD with neurological deficits.
- Open Access
- 16 November 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-9
Total en bloc spondylectomy combined with the satellite rod technique for spinal tumors
Background: Instrumentation failure (IF) is a common complication after total en bloc spondylectomy (TES) in spinal tumors. This study aims to evaluate the clinical outcomes of TES combined with the satellite rod technique for the treatment of primary and metastatic spinal tumors. Methods: The clinical data of 15 consecutively treated patients with spinal tumors who underwent TES combined with the satellite rod technique by a single posterior approach from June 2015 to September 2018 were analyzed retrospectively. Radiographic parameters including the local kyphotic angle (LKA), anterior vertebral height (AVH), posterior vertebral height (PVH), and intervertebral titanium mesh cage height (ITMCH) were assessed preoperatively, postoperatively, and at the final follow-up. The visual analog scale (VAS), Oswestry Disability Index (ODI), and American Spinal Injury Association (ASIA) scale were used to assess quality of life and neurological function. The operative duration, volume of blood loss, and complications were also recorded. Results: The mean operation time and volume of blood loss were 361.7 min and 2816.7 mL, respectively. During an average follow-up of 31.1 months, 2 patients died of tumor recurrence and multiple organ metastases, while recurrence was not found in any other patients. Solid fusion was achieved in all but one patient, and no implant-related complications occurred during the follow-up. The VAS, ODI, and ASIA scores significantly improved from before to after surgery (P < 0.05). The LKA, AVH, and PVH significantly improved from before to immediately after surgery and to the final follow-up (P < 0.05), and the postoperative and final follow-up values did not significantly differ (P > 0.05). Conclusions: TES combined with the satellite rod technique can yield strong three-dimensional fixation and reduce the occurrence of rod breakage, thereby improving the long-term quality of life of patients with spinal tumors.
- 16 November 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-9
Open AccessTotal en bloc spondylectomy combined with the satellite rod technique for spinal tumors
Background: Instrumentation failure (IF) is a common complication after total en bloc spondylectomy (TES) in spinal tumors. This study aims to evaluate the clinical outcomes of TES combined with the satellite rod technique for the treatment of primary and metastatic spinal tumors. Methods: The clinical data of 15 consecutively treated patients with spinal tumors who underwent TES combined with the satellite rod technique by a single posterior approach from June 2015 to September 2018 were analyzed retrospectively. Radiographic parameters including the local kyphotic angle (LKA), anterior vertebral height (AVH), posterior vertebral height (PVH), and intervertebral titanium mesh cage height (ITMCH) were assessed preoperatively, postoperatively, and at the final follow-up. The visual analog scale (VAS), Oswestry Disability Index (ODI), and American Spinal Injury Association (ASIA) scale were used to assess quality of life and neurological function. The operative duration, volume of blood loss, and complications were also recorded. Results: The mean operation time and volume of blood loss were 361.7 min and 2816.7 mL, respectively. During an average follow-up of 31.1 months, 2 patients died of tumor recurrence and multiple organ metastases, while recurrence was not found in any other patients. Solid fusion was achieved in all but one patient, and no implant-related complications occurred during the follow-up. The VAS, ODI, and ASIA scores significantly improved from before to after surgery (P < 0.05). The LKA, AVH, and PVH significantly improved from before to immediately after surgery and to the final follow-up (P < 0.05), and the postoperative and final follow-up values did not significantly differ (P > 0.05). Conclusions: TES combined with the satellite rod technique can yield strong three-dimensional fixation and reduce the occurrence of rod breakage, thereby improving the long-term quality of life of patients with spinal tumors.
- Open Access
- 20 October 2020
- Published by Springer Nature in Research Square
Total en bloc spondylectomy combined with the satellite rod technique for spinal tumors
Background: Instrumentation failure (IF) is a common complication after total en bloc spondylectomy (TES) in spinal tumors. This study aims to evaluate the clinical outcomes of TES combined with the satellite rod technique for the treatment of primary and metastatic spinal tumors.Methods: The clinical data of 15 consecutively treated patients with spinal tumors who underwent TES combined with satellite rod technique by a single posterior approach from June 2015 to September 2018 were analyzed retrospectively. Radiographic parameters including the local kyphotic angle (LKA), anterior vertebral height (AVH), posterior vertebral height (PVH) and intervertebral titanium mesh cage height (ITMCH) were assessed preoperatively, postoperatively and at the final follow-up. The visual analog scale (VAS), Oswestry Disability Index (ODI) and American Spinal Injury Association (ASIA) scale were used to assess quality of life and neurological function. The operative duration, volume of blood loss, and complications were also recorded.Results: The mean operation time and volume of blood loss were 361.7 min and 2816.7 mL, respectively. During an average follow-up of 31.1 months, 2 patients died of tumor recurrence and multiple organ metastases, while recurrence was not found in any other patients. Solid fusion was achieved in all but one patient, and no implant-related complications occurred during the follow-up. The VAS, ODI and ASIA scores significantly improved from before to after surgery (PP0.05).Conclusions: TES combined with the satellite rod technique can yield strong three-dimensional fixation and reduce the occurrence of rod breakage, thereby improving the long-term quality of life of patients with spinal tumors.
- 20 October 2020
- Published by Springer Nature in Research Square
Open AccessTotal en bloc spondylectomy combined with the satellite rod technique for spinal tumors
Background: Instrumentation failure (IF) is a common complication after total en bloc spondylectomy (TES) in spinal tumors. This study aims to evaluate the clinical outcomes of TES combined with the satellite rod technique for the treatment of primary and metastatic spinal tumors.Methods: The clinical data of 15 consecutively treated patients with spinal tumors who underwent TES combined with satellite rod technique by a single posterior approach from June 2015 to September 2018 were analyzed retrospectively. Radiographic parameters including the local kyphotic angle (LKA), anterior vertebral height (AVH), posterior vertebral height (PVH) and intervertebral titanium mesh cage height (ITMCH) were assessed preoperatively, postoperatively and at the final follow-up. The visual analog scale (VAS), Oswestry Disability Index (ODI) and American Spinal Injury Association (ASIA) scale were used to assess quality of life and neurological function. The operative duration, volume of blood loss, and complications were also recorded.Results: The mean operation time and volume of blood loss were 361.7 min and 2816.7 mL, respectively. During an average follow-up of 31.1 months, 2 patients died of tumor recurrence and multiple organ metastases, while recurrence was not found in any other patients. Solid fusion was achieved in all but one patient, and no implant-related complications occurred during the follow-up. The VAS, ODI and ASIA scores significantly improved from before to after surgery (PP0.05).Conclusions: TES combined with the satellite rod technique can yield strong three-dimensional fixation and reduce the occurrence of rod breakage, thereby improving the long-term quality of life of patients with spinal tumors.
- Open Access
- 10 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-13
Analysis of two minimally invasive procedures for osteoporotic vertebral compression fractures with intravertebral cleft: a systematic review and meta-analysis
Background: A systematic review and meta-analysis to assess the pros and cons of percutaneous vertebroplasty (PVP) versus kyphoplasty (PKP) for osteoporotic vertebral compression fractures (OVCFs) with intravertebral cleft (IVC) including all available evidence from controlled trials. Methods: Databases including Pubmed, Embase, Cochrane Library, China National Knowledge Infrastructure (CNKI), and Wanfang Data were searched to identify relevant studies comparing PVP and PKP for OVCFs with IVC. The outcomes mainly included visual analog scale (VAS), Oswestry Disability Index (ODI), local kyphotic angle (LKA), rate of vertebral height (VH%), and adverse events. Results: Nine studies enrolling 688 patients were eligible for meta-analysis. The results indicated no significant differences between the two groups in the short-and long-term VAS, ODI, LKA, or VH% (P > 0.05). Compared with PVP, PKP was associated with significantly longer operation time (P < 0.05), higher cost (P > 0.05), and more injected cement volume (P < 0.05). In terms of adverse events, PKP has a lower risk of cement leakage (P < 0.05), while with no significant difference in adjacent-level fracture rates (P > 0.05). Conclusion: The two procedures have similar short- and long-term pain relief, functional recovery, local kyphosis correction, and vertebral height maintenance in OVCFs with IVC. PKP is superior to PVP for the injected cement volume, and lower cement leakage rate, however, with longer operation time, more fluoroscopy times, and higher cost. Further randomized controlled trials (RCTs) should be conducted to confirm these results.
- 10 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-13
Open AccessAnalysis of two minimally invasive procedures for osteoporotic vertebral compression fractures with intravertebral cleft: a systematic review and meta-analysis
Background: A systematic review and meta-analysis to assess the pros and cons of percutaneous vertebroplasty (PVP) versus kyphoplasty (PKP) for osteoporotic vertebral compression fractures (OVCFs) with intravertebral cleft (IVC) including all available evidence from controlled trials. Methods: Databases including Pubmed, Embase, Cochrane Library, China National Knowledge Infrastructure (CNKI), and Wanfang Data were searched to identify relevant studies comparing PVP and PKP for OVCFs with IVC. The outcomes mainly included visual analog scale (VAS), Oswestry Disability Index (ODI), local kyphotic angle (LKA), rate of vertebral height (VH%), and adverse events. Results: Nine studies enrolling 688 patients were eligible for meta-analysis. The results indicated no significant differences between the two groups in the short-and long-term VAS, ODI, LKA, or VH% (P > 0.05). Compared with PVP, PKP was associated with significantly longer operation time (P < 0.05), higher cost (P > 0.05), and more injected cement volume (P < 0.05). In terms of adverse events, PKP has a lower risk of cement leakage (P < 0.05), while with no significant difference in adjacent-level fracture rates (P > 0.05). Conclusion: The two procedures have similar short- and long-term pain relief, functional recovery, local kyphosis correction, and vertebral height maintenance in OVCFs with IVC. PKP is superior to PVP for the injected cement volume, and lower cement leakage rate, however, with longer operation time, more fluoroscopy times, and higher cost. Further randomized controlled trials (RCTs) should be conducted to confirm these results.
- 11 July 2020
- Published by Springer Nature in European Spine Journal
- Vol. 30 (2) , 507-516
Anterior release without odontoidectomy for irreducible atlantoaxial dislocation: transoral or endoscopic transnasal?
Purpose To compare transoral and endoscopic transnasal anterior release without odontoidectomy and posterior reduction and fixation to treat irreducible atlantoaxial dislocation (IAAD). Methods From June 2006 to January 2017, 35 consecutive patients with IAAD underwent transoral (Tr-Oral group) or endoscopic transnasal (Tr-Nasal group) release and posterior fixation and fusion in our department. Clinical neurological recovery (Japanese Orthopedic Association (JOA) score) and radiological reduction parameters including atlantodontoid interval (ADI), space available for the cord (SAC) and cervicomedullary angle (CMA) were analyzed and compared. The operation duration, blood loss, length of intensive care unit (ICU)/hospital stay and complications were recorded. Results All 35 patients (18 and 17 patients in the Tr-Oral and Tr-Nasal groups, respectively) were followed up for a mean of 36.4 months (range, 21–60 months). All patients achieved excellent anatomical reduction and clinical neurological recovery, with no significant differences between the two groups. The JOA score, ADI, SAC and CMA were not significantly different between the two groups at various postoperative points. Although the Tr-Oral group had shorter operation time and less blood loss than the Tr-Nasal group, the Tr-Nasal group tended to have a significantly shorter hospital/ICU stay, earlier extubation and earlier oral intake than the Tr-Oral group. Conclusion The transoral and endoscopic transnasal approaches can achieve equivalent release and reduction effects when treating IAAD. Compared to the transoral approach, the endoscopic transnasal route is less invasive with earlier extubation and oral intake, shorter hospital/ICU stays and lower medical costs, which is conducive to enhanced recovery after surgery.
- 11 July 2020
- Published by Springer Nature in European Spine Journal
- Vol. 30 (2) , 507-516
Anterior release without odontoidectomy for irreducible atlantoaxial dislocation: transoral or endoscopic transnasal?
Purpose To compare transoral and endoscopic transnasal anterior release without odontoidectomy and posterior reduction and fixation to treat irreducible atlantoaxial dislocation (IAAD). Methods From June 2006 to January 2017, 35 consecutive patients with IAAD underwent transoral (Tr-Oral group) or endoscopic transnasal (Tr-Nasal group) release and posterior fixation and fusion in our department. Clinical neurological recovery (Japanese Orthopedic Association (JOA) score) and radiological reduction parameters including atlantodontoid interval (ADI), space available for the cord (SAC) and cervicomedullary angle (CMA) were analyzed and compared. The operation duration, blood loss, length of intensive care unit (ICU)/hospital stay and complications were recorded. Results All 35 patients (18 and 17 patients in the Tr-Oral and Tr-Nasal groups, respectively) were followed up for a mean of 36.4 months (range, 21–60 months). All patients achieved excellent anatomical reduction and clinical neurological recovery, with no significant differences between the two groups. The JOA score, ADI, SAC and CMA were not significantly different between the two groups at various postoperative points. Although the Tr-Oral group had shorter operation time and less blood loss than the Tr-Nasal group, the Tr-Nasal group tended to have a significantly shorter hospital/ICU stay, earlier extubation and earlier oral intake than the Tr-Oral group. Conclusion The transoral and endoscopic transnasal approaches can achieve equivalent release and reduction effects when treating IAAD. Compared to the transoral approach, the endoscopic transnasal route is less invasive with earlier extubation and oral intake, shorter hospital/ICU stays and lower medical costs, which is conducive to enhanced recovery after surgery.
- Open Access
- 20 January 2020
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 133 (2) , 165-173
A modified posterior wedge osteotomy with interbody fusion for the treatment of thoracolumbar kyphosis with Andersson lesions in ankylosing spondylitis: a 5-year follow-up study
Background Andersson lesions (ALs), also known as spondylodiscities, destructive vertebral lesions and spinal pseudarthrosis, usually occur in patients with ankylosing spondylitis (AS). Inflammatory and traumatic causes have been proposed to define this lesion. Different surgical approaches including anterior, posterior, and combined anterior and posterior procedure have been used to address the complications, consisting of mechanical pain, kyphotic deformity, and neurologic deficits. However, the preferred surgical procedure remains controversial. The aim of this study was to illustrate the safety, efficacy, and feasibility of a modified posterior wedge osteotomy for the ALs with kyphotic deformity in AS. Methods From June 2008 to January 2013, 23 patients (18 males, 5 females) at an average age of 44.8 years (range 25-69 years) were surgically treated for thoracolumbar kyphosis with ALs in AS via a modified posterior wedge osteotomy in our department. All sagittal balance parameters were assessed by standing lateral radiography of the whole spine before surgery and during the follow-up period. Assessment of radiologic fusion at follow-up was based on the Bridwell interbody fusion grading system. Ankylosing spondylitis quality of life (ASQoL) and visual analog scale (VAS) scores were performed to evaluate improvements in daily life function and back pain pre-operatively and post-operatively. Paired t tests were used to compare clinical data change in parametric values before and after surgery and the Mann-Whitney U test was employed for non-parametric comparisons. The radiographic data change was evaluated by repeated measure analysis of variance. Results The mean operative duration was 205.4 min (range 115-375 min), with an average blood loss of 488.5 mL (range 215-880 mL). Radiographical and clinical outcomes were assessed after a mean of 61.4 months of follow-up. The VAS back pain and ASQoL scores improved significantly in all patients (7.52 +/- 1.31 vs. 1.70 +/- 0.70, t = 18.30, P vs. 7.22 +/- 1.24, t = 18.53, P < 0.001, respectively). The thoracolumbar kyphosis (TLK) changed from 40.03 +/- 17.61 degrees pre-operatively to 13.86 +/- 6.65 degrees post-operatively, and 28.45 +/- 6.63 degrees at final follow-up (F = 57.54, P < 0.001), the thoracic kyphosis (TK) changed from 52.30 +/- 17.62 degrees pre-operatively to 27.76 +/- 6.50 degrees post-operatively, and 28.45 +/- 6.63 degrees at final follow-up (F = 57.29, P < 0.001), and lumbar lordosis (LL) changed from -29.56 +/- 9.73 degrees pre-operatively to -20.58 +/- 9.71 degrees post-operatively, and -20.73 +/- 10.27 degrees at final follow-up (F = 42.50, P < 0.001). Mean sagittal vertical axis (SVA) was improved from 11.82 +/- 4.55 cm pre-operatively to 5.12 +/- 2.42 cm post-operatively, and 5.03 +/- 2.29 cm at final follow-up (F = 79.36, P < 0.001). No obvious loss of correction occurred, according to the lack of significant differences in the sagittal balance parameters between post-operatively and the final follow-up in all patients (TK: 27.76 +/- 6.50 degrees vs. 28.45 +/- 6.63 degrees, TLK: 13.86 +/- 6.65 degrees vs. 14.42 +/- 6. 7 degrees, LL: -20.58 +/- 9.71 degrees vs. -20.73 +/- 10.27 degrees, and SVA: 5.12 +/- 2.42 cm vs. 5.03 +/- 2.29 cm, all P > 0.05, respectively). Conclusions The modified posterior wedge osteotomy is an accepted surgical procedure for treating thoracolumbar kyphosis with ALs in AS and results in satisfactory local kyphosis correction, solid fusion, and good clinical outcomes.
- 20 January 2020
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 133 (2) , 165-173
Open AccessA modified posterior wedge osteotomy with interbody fusion for the treatment of thoracolumbar kyphosis with Andersson lesions in ankylosing spondylitis: a 5-year follow-up study
Background Andersson lesions (ALs), also known as spondylodiscities, destructive vertebral lesions and spinal pseudarthrosis, usually occur in patients with ankylosing spondylitis (AS). Inflammatory and traumatic causes have been proposed to define this lesion. Different surgical approaches including anterior, posterior, and combined anterior and posterior procedure have been used to address the complications, consisting of mechanical pain, kyphotic deformity, and neurologic deficits. However, the preferred surgical procedure remains controversial. The aim of this study was to illustrate the safety, efficacy, and feasibility of a modified posterior wedge osteotomy for the ALs with kyphotic deformity in AS. Methods From June 2008 to January 2013, 23 patients (18 males, 5 females) at an average age of 44.8 years (range 25-69 years) were surgically treated for thoracolumbar kyphosis with ALs in AS via a modified posterior wedge osteotomy in our department. All sagittal balance parameters were assessed by standing lateral radiography of the whole spine before surgery and during the follow-up period. Assessment of radiologic fusion at follow-up was based on the Bridwell interbody fusion grading system. Ankylosing spondylitis quality of life (ASQoL) and visual analog scale (VAS) scores were performed to evaluate improvements in daily life function and back pain pre-operatively and post-operatively. Paired t tests were used to compare clinical data change in parametric values before and after surgery and the Mann-Whitney U test was employed for non-parametric comparisons. The radiographic data change was evaluated by repeated measure analysis of variance. Results The mean operative duration was 205.4 min (range 115-375 min), with an average blood loss of 488.5 mL (range 215-880 mL). Radiographical and clinical outcomes were assessed after a mean of 61.4 months of follow-up. The VAS back pain and ASQoL scores improved significantly in all patients (7.52 +/- 1.31 vs. 1.70 +/- 0.70, t = 18.30, P vs. 7.22 +/- 1.24, t = 18.53, P < 0.001, respectively). The thoracolumbar kyphosis (TLK) changed from 40.03 +/- 17.61 degrees pre-operatively to 13.86 +/- 6.65 degrees post-operatively, and 28.45 +/- 6.63 degrees at final follow-up (F = 57.54, P < 0.001), the thoracic kyphosis (TK) changed from 52.30 +/- 17.62 degrees pre-operatively to 27.76 +/- 6.50 degrees post-operatively, and 28.45 +/- 6.63 degrees at final follow-up (F = 57.29, P < 0.001), and lumbar lordosis (LL) changed from -29.56 +/- 9.73 degrees pre-operatively to -20.58 +/- 9.71 degrees post-operatively, and -20.73 +/- 10.27 degrees at final follow-up (F = 42.50, P < 0.001). Mean sagittal vertical axis (SVA) was improved from 11.82 +/- 4.55 cm pre-operatively to 5.12 +/- 2.42 cm post-operatively, and 5.03 +/- 2.29 cm at final follow-up (F = 79.36, P < 0.001). No obvious loss of correction occurred, according to the lack of significant differences in the sagittal balance parameters between post-operatively and the final follow-up in all patients (TK: 27.76 +/- 6.50 degrees vs. 28.45 +/- 6.63 degrees, TLK: 13.86 +/- 6.65 degrees vs. 14.42 +/- 6. 7 degrees, LL: -20.58 +/- 9.71 degrees vs. -20.73 +/- 10.27 degrees, and SVA: 5.12 +/- 2.42 cm vs. 5.03 +/- 2.29 cm, all P > 0.05, respectively). Conclusions The modified posterior wedge osteotomy is an accepted surgical procedure for treating thoracolumbar kyphosis with ALs in AS and results in satisfactory local kyphosis correction, solid fusion, and good clinical outcomes.