Yunus C. Yalcin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yunus C. Yalcin has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Kadir Caliskan
Thoraxcenter, Department of Cardiology, Erasmus University Medical Center, Rotterdam, The Netherlands
7 shared publications - Ad J. J. C. Bogers
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, the Netherlands
3 shared publications - Christiaan F J Antonides
Department of Cardio-Thoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
2 shared publications - Kevin M. Veen
Department of Cardiothoracic Surgery, Erasmus MC, Rotterdam, The Netherlands
2 shared publications Olivier C. Manintveld
Thoraxcenter, Department of Cardiology, Unit Heart Failure, Heart Transplantation & Mechanical Circulatory Support
2 shared publicationsRahatullah Muslem
Thoraxcenter, Department of Cardiology, Unit Heart Failure, Heart Transplantation & Mechanical Circulatory Support; Departments of Cardiothoracic Surgery
2 shared publications
Latest Publications
- Open Access
- 24 January 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (5) , 1164-1175
Survival and adverse events in patients with atrial fibrillation at left ventricular assist device implantation: an analysis of the European Registry for Patients with Mechanical Circulatory Support
Atrial fibrillation (AF) is a risk factor for mortality and cerebrovascular accidents (CVAs) and is common in patients with heart failure. This study evaluated survival and adverse events in patients with a left ventricular assist device (LVAD) and a history of AF in the European Registry for Patients with Mechanical Circulatory Support. Patients with a continuous-flow LVAD, AF or sinus rhythm (SR) and a follow-up were included. Kaplan–Meier analyses for survival (including a propensity-scored matched analysis), freedom from CVA, pump thrombosis, bleeding and a composite of pump thrombosis/CVA were performed. To correct for covariate imbalance, a Kaplan-Meier (KM) analysis was performed after propensity score (PS) matching the groups. Finally, a Cox regression was performed for predictors of lower survival. Overall, 1821 patients (83% male) were included, with a median age of 57 years and a median follow-up of 13.1 months (interquartile range: 4.3–27.7). Preoperative Electrocardiogram (ECG) rhythm was AF in 421 (23.1%) and SR in 1400 (76.9%) patients. Patients with pre-LVAD AF had a lower ≤90-day (81.9% vs 87.1%, P = 0.0047) and 4-year (35.4% vs 44.2%, P = 0.0083) survival compared to SR. KM analysis with PS matching groups revealed a trend (P = 0.087) towards decreased survival. Univariable analyses confirmed pre-LVAD AF as a predictor for mortality, but the multivariable analysis did not. No difference in the rate of adverse events was found. An analysis of patients at 24 months revealed a higher rate of CVAs for pre-LVAD AF patients (77% vs 94.3%, P < 0.0001). Patients with pre-LVAD AF undergoing LVAD implantation had a worse survival. However, after performing a multivariate analysis, and PS matching analysis, AF was no longer significant, indicating a worser preoperative condition in these patients. Concerning thrombo-embolic events, only patients with pre-LVAD AF alive beyond 24 months have a higher risk of CVAs.
- 24 January 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (5) , 1164-1175
Open AccessSurvival and adverse events in patients with atrial fibrillation at left ventricular assist device implantation: an analysis of the European Registry for Patients with Mechanical Circulatory Support
Atrial fibrillation (AF) is a risk factor for mortality and cerebrovascular accidents (CVAs) and is common in patients with heart failure. This study evaluated survival and adverse events in patients with a left ventricular assist device (LVAD) and a history of AF in the European Registry for Patients with Mechanical Circulatory Support. Patients with a continuous-flow LVAD, AF or sinus rhythm (SR) and a follow-up were included. Kaplan–Meier analyses for survival (including a propensity-scored matched analysis), freedom from CVA, pump thrombosis, bleeding and a composite of pump thrombosis/CVA were performed. To correct for covariate imbalance, a Kaplan-Meier (KM) analysis was performed after propensity score (PS) matching the groups. Finally, a Cox regression was performed for predictors of lower survival. Overall, 1821 patients (83% male) were included, with a median age of 57 years and a median follow-up of 13.1 months (interquartile range: 4.3–27.7). Preoperative Electrocardiogram (ECG) rhythm was AF in 421 (23.1%) and SR in 1400 (76.9%) patients. Patients with pre-LVAD AF had a lower ≤90-day (81.9% vs 87.1%, P = 0.0047) and 4-year (35.4% vs 44.2%, P = 0.0083) survival compared to SR. KM analysis with PS matching groups revealed a trend (P = 0.087) towards decreased survival. Univariable analyses confirmed pre-LVAD AF as a predictor for mortality, but the multivariable analysis did not. No difference in the rate of adverse events was found. An analysis of patients at 24 months revealed a higher rate of CVAs for pre-LVAD AF patients (77% vs 94.3%, P < 0.0001). Patients with pre-LVAD AF undergoing LVAD implantation had a worse survival. However, after performing a multivariate analysis, and PS matching analysis, AF was no longer significant, indicating a worser preoperative condition in these patients. Concerning thrombo-embolic events, only patients with pre-LVAD AF alive beyond 24 months have a higher risk of CVAs.
- Open Access
- 8 May 2021
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 60 (3) , 506-515
Driveline exit-site care protocols in patients with left ventricular assist devices: a systematic review
: OBJECTIVES: Driveline infections continue to be a significant complication following left ventricular assist device (LVAD) implantation. Driveline exit-site care is crucial for the prevention of infections; however, there are no uniform guidelines. The goal of this study was to provide an overview of the currently published driveline exit-site care protocols in patients with LVAD. METHODS: A systematic literature review was performed. Studies before 15 December 2020 were included if the number of driveline infections was a primary outcome and the driveline exit-site care protocol was explained. RESULTS: Eleven articles were included in the systematic review, including 1602 patients with LVADs. The median of the frequency of driveline infections in the articles was 13.8% with a range of 0–52.6%. There was a marked variability in the methods of care of driveline exit sites, without a standardized driveline dressing technique in patients with LVADs. The frequency of driveline infections was 6–7.5% in studies using a dressing kit that included chlorhexidine, a silver-based dressing and an anchoring device. Furthermore, there was variability in the anchoring devices and the frequency of dressing changes, which varied from daily to weekly. No specific anchoring device or change frequency was found to be superior. CONCLUSIONS: Based on this systematic review, driveline exit care protocols that included chlorhexidine, a silver-based dressing, the use of an anchoring device and dressing kits might be best in reducing driveline infection rates. However, prospective studies with larger cohorts are needed to establish the optimal protocol for driveline exit-site care.
- 8 May 2021
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 60 (3) , 506-515
Open AccessDriveline exit-site care protocols in patients with left ventricular assist devices: a systematic review
: OBJECTIVES: Driveline infections continue to be a significant complication following left ventricular assist device (LVAD) implantation. Driveline exit-site care is crucial for the prevention of infections; however, there are no uniform guidelines. The goal of this study was to provide an overview of the currently published driveline exit-site care protocols in patients with LVAD. METHODS: A systematic literature review was performed. Studies before 15 December 2020 were included if the number of driveline infections was a primary outcome and the driveline exit-site care protocol was explained. RESULTS: Eleven articles were included in the systematic review, including 1602 patients with LVADs. The median of the frequency of driveline infections in the articles was 13.8% with a range of 0–52.6%. There was a marked variability in the methods of care of driveline exit sites, without a standardized driveline dressing technique in patients with LVADs. The frequency of driveline infections was 6–7.5% in studies using a dressing kit that included chlorhexidine, a silver-based dressing and an anchoring device. Furthermore, there was variability in the anchoring devices and the frequency of dressing changes, which varied from daily to weekly. No specific anchoring device or change frequency was found to be superior. CONCLUSIONS: Based on this systematic review, driveline exit care protocols that included chlorhexidine, a silver-based dressing, the use of an anchoring device and dressing kits might be best in reducing driveline infection rates. However, prospective studies with larger cohorts are needed to establish the optimal protocol for driveline exit-site care.
- Open Access
- 20 March 2020
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 7 (3) , 1085-1094
Outcomes of Patients after Successful Left Ventricular Assist Device Explantation: A EUROMACS Study
Aims Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1–2% of the cases. However, follow‐up data about this condition are scarcely available in the literature. This study aimed to report the long‐term outcomes and clinical management following LVAD explantation. Methods and results An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre‐implant characteristics were retrieved and compared with the non‐recovery patients. The follow‐up data after explantation were collected via a questionnaire. A Kaplan–Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow‐up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter‐quartile range: 29–52), and 23 (82%) were male. Baseline left ventricular ejection fraction was 18% (inter‐quartile range: 10–20%), and 60.7% of the patients had Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 or 2. Aetiologies of HF were dilated cardiomyopathy in 36%, myocarditis in 32%, and ischaemic in 14% of the patients, and 18% had miscellaneous aetiologies. The devices implanted were HeartMate II in 14 (50%), HVAD in 11 (39%), HeartMate 3 in 2 (7%), and 1 unknown with a median duration of support of 410 days (range: 59–1286). The median follow‐up after explantation was 26 months (range 0.3–73 months), and 82% of the patients were in New York Heart Association Class I or II. Beta‐blockers were prescribed to 85%, angiotensin‐converting enzyme inhibitors to 71%, and loop diuretics to 50% of the patients, respectively. Freedom from the composite endpoint was 100% after 30 days and 88% after 2 years. Conclusions The survival after LVAD explantation is excellent without the need for heart transplantation or LVAD reimplantation. Only a minority of the patients suffer from a relapse of significant HF.
- 20 March 2020
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 7 (3) , 1085-1094
Open AccessOutcomes of Patients after Successful Left Ventricular Assist Device Explantation: A EUROMACS Study
Aims Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1–2% of the cases. However, follow‐up data about this condition are scarcely available in the literature. This study aimed to report the long‐term outcomes and clinical management following LVAD explantation. Methods and results An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre‐implant characteristics were retrieved and compared with the non‐recovery patients. The follow‐up data after explantation were collected via a questionnaire. A Kaplan–Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow‐up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter‐quartile range: 29–52), and 23 (82%) were male. Baseline left ventricular ejection fraction was 18% (inter‐quartile range: 10–20%), and 60.7% of the patients had Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 or 2. Aetiologies of HF were dilated cardiomyopathy in 36%, myocarditis in 32%, and ischaemic in 14% of the patients, and 18% had miscellaneous aetiologies. The devices implanted were HeartMate II in 14 (50%), HVAD in 11 (39%), HeartMate 3 in 2 (7%), and 1 unknown with a median duration of support of 410 days (range: 59–1286). The median follow‐up after explantation was 26 months (range 0.3–73 months), and 82% of the patients were in New York Heart Association Class I or II. Beta‐blockers were prescribed to 85%, angiotensin‐converting enzyme inhibitors to 71%, and loop diuretics to 50% of the patients, respectively. Freedom from the composite endpoint was 100% after 30 days and 88% after 2 years. Conclusions The survival after LVAD explantation is excellent without the need for heart transplantation or LVAD reimplantation. Only a minority of the patients suffer from a relapse of significant HF.
- 15 December 2019
- Published by Wiley in Artificial Organs
- Vol. 44 (5) , 533-534
Intermittent levosimendan treatment for late onset right ventricular failure in a patient supported with a left ventricular assist device
- 15 December 2019
- Published by Wiley in Artificial Organs
- Vol. 44 (5) , 533-534
Intermittent levosimendan treatment for late onset right ventricular failure in a patient supported with a left ventricular assist device
- Open Access
- 23 October 2019
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 6 (Supplement) , S92-S93
127. Novel Treatment Approach for Left Ventricular Assist Device-related Infections
Left ventricular assist device (LVAD) implantation has become an effective treatment option for patients with severe heart failure. However, infections remain a substantial risk. Therefore, the aim of this study was to gain insight in the incidence and outcome of LVAD infections in our center and develop an up-to-date flowchart for the management of LVAD-related infections. A retrospective study was performed which included all patients with an LVAD implanted between 2006 until 2019, along with a rigorous review of the current literature. Clinical records and microbiological laboratory results of all patients were reviewed. In view of local infectious complications, a flowchart was developed for the contemporary management of LVAD-related infections (Figure 1). Overall, 106 patients (median age 54 years [IQR 47–60], 78% male) were included, of whom 92 (87%) as bridge-to-transplantation/decision and 14 (13%) as destination therapy. LVAD-related infections occurred in n = 30 (28%) of the patients. The median time until first infection was 308 days [IQR 115–528], and the median duration of hospital stay was 16 days [IQR 4–29]. Eighty percent of LVAD-related infections were driveline-related. The most common causative pathogen was Staphylococcus aureus, which was present in almost half of the cases (40%). Patients who experienced infections were younger (46 [IQR 37–57] vs. 56 [IQR 52–62]; P < 0.001).The survival rate at 3 years was 76% in the infected vs. 94% not infected patients; P = 0.037). A secondary infection occurred in 10 patients (33%). At 3 years of follow-up, 31 patients were successfully transplanted. Six patients with deep S. aureus driveline infections were treated according to the standardized protocol of whom 2 with suppressive therapy by cephalexin, with clinical success so far. LVAD infections occur frequently and lead to prolonged periods of hospital admissions and death. The lack of standardized treatment regimens complicates the treatment of LVAD-related infections. A comprehensive flowchart to treat future LVAD-related infections in a protocolized fashion was developed, based on our single-center experience. While the preliminary results look promising, more follow-up time of the treated patients is needed. All authors: No reported disclosures.
- 23 October 2019
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 6 (Supplement) , S92-S93
Open Access127. Novel Treatment Approach for Left Ventricular Assist Device-related Infections
Left ventricular assist device (LVAD) implantation has become an effective treatment option for patients with severe heart failure. However, infections remain a substantial risk. Therefore, the aim of this study was to gain insight in the incidence and outcome of LVAD infections in our center and develop an up-to-date flowchart for the management of LVAD-related infections. A retrospective study was performed which included all patients with an LVAD implanted between 2006 until 2019, along with a rigorous review of the current literature. Clinical records and microbiological laboratory results of all patients were reviewed. In view of local infectious complications, a flowchart was developed for the contemporary management of LVAD-related infections (Figure 1). Overall, 106 patients (median age 54 years [IQR 47–60], 78% male) were included, of whom 92 (87%) as bridge-to-transplantation/decision and 14 (13%) as destination therapy. LVAD-related infections occurred in n = 30 (28%) of the patients. The median time until first infection was 308 days [IQR 115–528], and the median duration of hospital stay was 16 days [IQR 4–29]. Eighty percent of LVAD-related infections were driveline-related. The most common causative pathogen was Staphylococcus aureus, which was present in almost half of the cases (40%). Patients who experienced infections were younger (46 [IQR 37–57] vs. 56 [IQR 52–62]; P < 0.001).The survival rate at 3 years was 76% in the infected vs. 94% not infected patients; P = 0.037). A secondary infection occurred in 10 patients (33%). At 3 years of follow-up, 31 patients were successfully transplanted. Six patients with deep S. aureus driveline infections were treated according to the standardized protocol of whom 2 with suppressive therapy by cephalexin, with clinical success so far. LVAD infections occur frequently and lead to prolonged periods of hospital admissions and death. The lack of standardized treatment regimens complicates the treatment of LVAD-related infections. A comprehensive flowchart to treat future LVAD-related infections in a protocolized fashion was developed, based on our single-center experience. While the preliminary results look promising, more follow-up time of the treated patients is needed. All authors: No reported disclosures.
- 1 October 2019
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 40 (Supplement)
P5421Prevalence of electromagnetic interference from left ventricular assist devices in patients with implantable cardioverter defibrillator/pacemakers
Background: Many patients eligible for left ventricular assist device (LVAD) therapy already have an implantable cardioverter defibrillator (ICD) and/or pacemaker (PM). However, electromagnetic interference (EMI) between the LVAD and ICD/PM devices could be cumbersome. Purpose: The aim of this study was to investigate the prevalence of EMI between different types of ICD/PM in patients implanted with an LVAD. Methods: Data was obtained through a retrospective electronic patient database analysis of all LVAD patients (including HeartMate II (HMII) and HeartMate 3 (HM3)), from our tertiary referral center, from December 2006 to February 2019. Device switches have also been taken into account due to elective replacement. Electromagnetic interference was defined as ICD/PM telemetry interference (i.e. the inability to interrogate ICD/PM) Results: In total, 109 patients received an LVAD (mean age 52±12, 83% male), Of these, 86 (79%) patients had an ICD/PM at LVAD implantation. One patient with ICD/PM was excluded from further analysis because of missing follow-up data. Among the 85 patients (45 HM II and 40 HM3), 11 (13%) experienced EMI; 5 (11%) with a HM II and 6 (15%) with a HM3 (p=0.59). The implanted ICD/PM devices were from Medtronic (n=25), Abbott (n=23), Biotronik (n=18), Boston Scientific (n=18), and Microport (n=1). EMI with the HM II was present in St Jude/Abbott devices (type 1 Atlas, 1 Unify, 1 Fortify, and 2 Promote). In HM 3 LVAD patients, EMI was observed in Biotronik devices (1 Lumax, 1 Ilivia, 1 Ilesto, and 2 Iperia) and Medtronic (Claria). Conclusion: In our cohort of HM II and HM 3 LVAD patients, at least one in seven patients experienced EMI from either the HM II or HM3 LVAD with the ICD/PM. Electromagnetic interference from HM II LVADs was mainly present in patients with St Jude/Abbott ICD/PM devices However, in the HM3 patients, EMI was mainly present in patients with Biotronik devices, which is not yet widely known!
- 1 October 2019
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 40 (Supplement)
P5421Prevalence of electromagnetic interference from left ventricular assist devices in patients with implantable cardioverter defibrillator/pacemakers
Background: Many patients eligible for left ventricular assist device (LVAD) therapy already have an implantable cardioverter defibrillator (ICD) and/or pacemaker (PM). However, electromagnetic interference (EMI) between the LVAD and ICD/PM devices could be cumbersome. Purpose: The aim of this study was to investigate the prevalence of EMI between different types of ICD/PM in patients implanted with an LVAD. Methods: Data was obtained through a retrospective electronic patient database analysis of all LVAD patients (including HeartMate II (HMII) and HeartMate 3 (HM3)), from our tertiary referral center, from December 2006 to February 2019. Device switches have also been taken into account due to elective replacement. Electromagnetic interference was defined as ICD/PM telemetry interference (i.e. the inability to interrogate ICD/PM) Results: In total, 109 patients received an LVAD (mean age 52±12, 83% male), Of these, 86 (79%) patients had an ICD/PM at LVAD implantation. One patient with ICD/PM was excluded from further analysis because of missing follow-up data. Among the 85 patients (45 HM II and 40 HM3), 11 (13%) experienced EMI; 5 (11%) with a HM II and 6 (15%) with a HM3 (p=0.59). The implanted ICD/PM devices were from Medtronic (n=25), Abbott (n=23), Biotronik (n=18), Boston Scientific (n=18), and Microport (n=1). EMI with the HM II was present in St Jude/Abbott devices (type 1 Atlas, 1 Unify, 1 Fortify, and 2 Promote). In HM 3 LVAD patients, EMI was observed in Biotronik devices (1 Lumax, 1 Ilivia, 1 Ilesto, and 2 Iperia) and Medtronic (Claria). Conclusion: In our cohort of HM II and HM 3 LVAD patients, at least one in seven patients experienced EMI from either the HM II or HM3 LVAD with the ICD/PM. Electromagnetic interference from HM II LVADs was mainly present in patients with St Jude/Abbott ICD/PM devices However, in the HM3 patients, EMI was mainly present in patients with Biotronik devices, which is not yet widely known!
- 1 August 2019
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 38 (8) , 797-805
Acute kidney injury following left ventricular assist device implantation: Contemporary insights and future perspectives
- 1 August 2019
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 38 (8) , 797-805
Acute kidney injury following left ventricular assist device implantation: Contemporary insights and future perspectives
- 1 January 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (1) , e12-e13
Modification of a Ventricular Assistance Device for a Hemiplegic Left Ventricular Assist Device Patient
Neurologic events occur in up to 18% of patients with continuous-flow left ventricular assist devices (LVAD) and is associated with significant morbidity and mortality. The current form of the LVAD equipment is not suited to serve patients who are impaired by a stroke. By creating an assistance device for the LVAD equipment, we have been able to greatly improve the quality of life and self-dependence of a hemiplegic LVAD patient.
- 1 January 2019
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 65 (1) , e12-e13
Modification of a Ventricular Assistance Device for a Hemiplegic Left Ventricular Assist Device Patient
Neurologic events occur in up to 18% of patients with continuous-flow left ventricular assist devices (LVAD) and is associated with significant morbidity and mortality. The current form of the LVAD equipment is not suited to serve patients who are impaired by a stroke. By creating an assistance device for the LVAD equipment, we have been able to greatly improve the quality of life and self-dependence of a hemiplegic LVAD patient.