Joo Hyun
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joo Hyun has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Tae-Young Chung
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
6 shared publications Dong Hui Lim
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, #81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea
4 shared publicationsSungsoon Hwang
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, #81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea
3 shared publications- Dong Hui Lim
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Republic of Korea
2 shared publications Eui-Sang Chung
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, #81 Irwon-ro, Gangnam-gu, Seoul, 06351, South Korea
2 shared publicationsJin Seok Choi
Saevit Eye Hospital Goyang Korea
2 shared publications
Latest Publications
- Open Access
- 15 June 2020
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 61 (6) , 680-684
Central Toxic Keratopathy after Femtosecond Laser in-situ Keratomileusis
Purpose: To report a case of central toxic keratopathy after femtosecond laser in-situ keratomileusis (LASIK). Case summary: A 26-year-old male developed diffuse lamellar keratitis bilaterally on day 2 after femtosecond LASIK. He was applying topical steroid frequently, while also using topical antibiotics. On day 6 after LASIK, slit-lamp biomicroscopy showed a thick central corneal opacity on the right eye so a flap irrigation was performed. He was then treated with systemic methylprednisolone. A corneal epithelial crack and stromal striae were noted by slit-lamp biomicroscopy on postoperative day 10. Four weeks after LASIK, the refractive error was +4.25 Dsph =-1.25 Dcyl Axis 80°. He was treated with topical steroid, topical antibiotics, and oral doxycycline until eight weeks after LASIK. Eight weeks after LASIK, the patient was observed without treatment. The central corneal thickness recovered from 488 μm at eight weeks to 540 μm, and the refractive error was +1.25 Dsph =-0.75 Dcyl Axis 85°a t postoperative 72 weeks. The central corneal opacity also recovered. Conclusions: Because femtosecond LASIK may result in a combination of diffuse lamellar keratitis and central toxic keratopathy, the clinical characteristics and natural course of both diseases should be understood and timely treatment should be available.
- 15 June 2020
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 61 (6) , 680-684
Open AccessCentral Toxic Keratopathy after Femtosecond Laser in-situ Keratomileusis
Purpose: To report a case of central toxic keratopathy after femtosecond laser in-situ keratomileusis (LASIK). Case summary: A 26-year-old male developed diffuse lamellar keratitis bilaterally on day 2 after femtosecond LASIK. He was applying topical steroid frequently, while also using topical antibiotics. On day 6 after LASIK, slit-lamp biomicroscopy showed a thick central corneal opacity on the right eye so a flap irrigation was performed. He was then treated with systemic methylprednisolone. A corneal epithelial crack and stromal striae were noted by slit-lamp biomicroscopy on postoperative day 10. Four weeks after LASIK, the refractive error was +4.25 Dsph =-1.25 Dcyl Axis 80°. He was treated with topical steroid, topical antibiotics, and oral doxycycline until eight weeks after LASIK. Eight weeks after LASIK, the patient was observed without treatment. The central corneal thickness recovered from 488 μm at eight weeks to 540 μm, and the refractive error was +1.25 Dsph =-0.75 Dcyl Axis 85°a t postoperative 72 weeks. The central corneal opacity also recovered. Conclusions: Because femtosecond LASIK may result in a combination of diffuse lamellar keratitis and central toxic keratopathy, the clinical characteristics and natural course of both diseases should be understood and timely treatment should be available.
- Open Access
- 1 January 2019
- Published by Korean Medical Association in Journal of the Korean Medical Association
- Vol. 62 (12) , 616-622
Surgical treatment of presbyopia I
- 1 January 2019
- Published by Korean Medical Association in Journal of the Korean Medical Association
- Vol. 62 (12) , 616-622
Open AccessSurgical treatment of presbyopia I
- Open Access
- 9 November 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 292
Comparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial
To compare the clinical outcome of Precizon toric intraocular lens (IOL) (Ophtec Inc.) to that of Tecnis toric IOL (Abbott Medical Optics Inc.). This randomized comparative study included 40 eyes (Precizon, 20 eyes; Tecnis, 20 eyes) of 40 patients with visually significant cataract and corneal astigmatism who underwent cataract surgery. Changes in uncorrected distant visual acuity (UCDVA), best corrected distant visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), refraction, residual astigmatism, rotation of the IOL axis, and higher order aberrations at 3 months postoperatively were evaluated. Vector analysis was performed using the Alpins method. Both groups showed significant reduction in refractive astigmatism after the surgery (Precizon: − 1.06 ± 0.94 Diopter (D) to − 0.31 ± 0.29 D, p = 0.042; Tecnis: − 1.83 ± 1.29 D to − 0.41 ± 0.33 D, p = 0.015). There was no significant (p > 0.05) difference in postoperative UCDVA, BCDVA, or residual astigmatism between the two groups, although a tendency of better UCIVA was observed in the Precizon group. Vector analysis parameters showed no statistically significant difference beween groups(P > 0.05). Significant difference in rotation of toric IOL axis was found between the two groups (Precizon: 1.50° ± 0.84, Tecnis: 2.56° ± 0.68, p = 0.010). Spherical aberration in the Precizon group was significantly (p = 0.005) lower than that in the Tecnis group. The Precizon toric IOL group had better rotational stability at 3-month postoperatively. Both Precizon toric IOL and Tecnis toric IOL could be effectively used by cataract surgeons to correct preexisting corneal astigmatism through cataract surgery. http://clinicaltrials.gov , NCT03085901 , retrospectively registered on 21 March 2017.
- 9 November 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 292
Open AccessComparison of clinical outcomes of toric intraocular lens, Precizon vs Tecnis: a single center randomized controlled trial
To compare the clinical outcome of Precizon toric intraocular lens (IOL) (Ophtec Inc.) to that of Tecnis toric IOL (Abbott Medical Optics Inc.). This randomized comparative study included 40 eyes (Precizon, 20 eyes; Tecnis, 20 eyes) of 40 patients with visually significant cataract and corneal astigmatism who underwent cataract surgery. Changes in uncorrected distant visual acuity (UCDVA), best corrected distant visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA), refraction, residual astigmatism, rotation of the IOL axis, and higher order aberrations at 3 months postoperatively were evaluated. Vector analysis was performed using the Alpins method. Both groups showed significant reduction in refractive astigmatism after the surgery (Precizon: − 1.06 ± 0.94 Diopter (D) to − 0.31 ± 0.29 D, p = 0.042; Tecnis: − 1.83 ± 1.29 D to − 0.41 ± 0.33 D, p = 0.015). There was no significant (p > 0.05) difference in postoperative UCDVA, BCDVA, or residual astigmatism between the two groups, although a tendency of better UCIVA was observed in the Precizon group. Vector analysis parameters showed no statistically significant difference beween groups(P > 0.05). Significant difference in rotation of toric IOL axis was found between the two groups (Precizon: 1.50° ± 0.84, Tecnis: 2.56° ± 0.68, p = 0.010). Spherical aberration in the Precizon group was significantly (p = 0.005) lower than that in the Tecnis group. The Precizon toric IOL group had better rotational stability at 3-month postoperatively. Both Precizon toric IOL and Tecnis toric IOL could be effectively used by cataract surgeons to correct preexisting corneal astigmatism through cataract surgery. http://clinicaltrials.gov , NCT03085901 , retrospectively registered on 21 March 2017.
- Open Access
- 7 March 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 1-10
Prospective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans
To evaluate monocular and binocular visual outcomes for near, intermediate, and far distance in patients implanted with diffractive multifocal intraocular lenses (IOLs) with different add power contralaterally. This is a prospective contralateral study. Two diffractive multifocal IOLs with different added power were implanted bilaterally in twenty patients. TECNIS® ZKB00 (+ 2.75 D) was implanted in a dominant eye, and TECNIS® ZLB00 (+ 3.25 D) was implanted in a non-dominant eye. Uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and manifest refraction (MR) values were measured at 1 month and 3 months postoperatively. At the 3-month follow-up, defocus curve, contrast sensitivity, and reading performance were evaluated. Quality of vision, overall satisfaction, and spectacle independence were evaluated by questionnaire. Postoperative binocular UDVA, visual acuity at 80 cm, 60 cm, 50 cm, 43 cm, 33 cm were − 0.08 ± 0.10, 0.12 ± 0.14, 0.09 ± 0.09, 0.07 ± 0.11, 0.14 ± 0.09, 0.25 ± 0.11 logMAR. The binocular defocus curve showed an extended range of good visual acuity with sharp vision being observed from 0 D to − 2.50 D defocus (logMAR≤0.1). Reading performance was significantly improved compared to baseline. All patients were spectacle-free at distance, and 94.74% of the patients did not require glasses for near and intermediate vision. Mix-and-match implantation of diffractive multifocal IOLs with different add power provides an excellent wide range of vision, as well as high levels of visual quality and patient satisfaction. ClinicalTrials.gov , NCT02556944, https://clinicaltrials.gov/show/NCT02556944
- 7 March 2018
- Published by Springer Nature in BMC Ophthalmology
- Vol. 18 (1) , 1-10
Open AccessProspective study of bilateral mix-and-match implantation of diffractive multifocal intraocular lenses in Koreans
To evaluate monocular and binocular visual outcomes for near, intermediate, and far distance in patients implanted with diffractive multifocal intraocular lenses (IOLs) with different add power contralaterally. This is a prospective contralateral study. Two diffractive multifocal IOLs with different added power were implanted bilaterally in twenty patients. TECNIS® ZKB00 (+ 2.75 D) was implanted in a dominant eye, and TECNIS® ZLB00 (+ 3.25 D) was implanted in a non-dominant eye. Uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), and manifest refraction (MR) values were measured at 1 month and 3 months postoperatively. At the 3-month follow-up, defocus curve, contrast sensitivity, and reading performance were evaluated. Quality of vision, overall satisfaction, and spectacle independence were evaluated by questionnaire. Postoperative binocular UDVA, visual acuity at 80 cm, 60 cm, 50 cm, 43 cm, 33 cm were − 0.08 ± 0.10, 0.12 ± 0.14, 0.09 ± 0.09, 0.07 ± 0.11, 0.14 ± 0.09, 0.25 ± 0.11 logMAR. The binocular defocus curve showed an extended range of good visual acuity with sharp vision being observed from 0 D to − 2.50 D defocus (logMAR≤0.1). Reading performance was significantly improved compared to baseline. All patients were spectacle-free at distance, and 94.74% of the patients did not require glasses for near and intermediate vision. Mix-and-match implantation of diffractive multifocal IOLs with different add power provides an excellent wide range of vision, as well as high levels of visual quality and patient satisfaction. ClinicalTrials.gov , NCT02556944, https://clinicaltrials.gov/show/NCT02556944
- Open Access
- 1 January 2018
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 59 (11) , 1009-1016
Comparative Effect of Spectacles and Orthokeratology Lenses on Axial Elongation in Children with Mild-to-Moderate Myopia
Kim TH, et al. J Korean Ophthalmol Soc. 2018 Nov;59(11):1009-1016. https://doi.org/10.3341/jkos.2018.59.11.1009
- 1 January 2018
- Published by Korean Ophthalmological Society in Journal of the Korean Ophthalmological Society
- Vol. 59 (11) , 1009-1016
Open AccessComparative Effect of Spectacles and Orthokeratology Lenses on Axial Elongation in Children with Mild-to-Moderate Myopia
Kim TH, et al. J Korean Ophthalmol Soc. 2018 Nov;59(11):1009-1016. https://doi.org/10.3341/jkos.2018.59.11.1009
- Open Access
- 1 January 2018
- Published by Korean Ophthalmological Society in Korean Journal of Ophthalmology
- Vol. 32 (1) , 16-22
Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
Hwang S, et al. Korean J Ophthalmol. 2017 Dec;32:e9. https://doi.org/10.3341/kjo.2017.0060
- 1 January 2018
- Published by Korean Ophthalmological Society in Korean Journal of Ophthalmology
- Vol. 32 (1) , 16-22
Open AccessMyopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
Hwang S, et al. Korean J Ophthalmol. 2017 Dec;32:e9. https://doi.org/10.3341/kjo.2017.0060
- Open Access
- 22 December 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 260
Buffering zone of implantable Collamer lens sizing in V4c
The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), and the V4 ICL sizes were then converted to V4c ICL sizes with a size-converting table. We defined the “normal-sizing group” as having a pre-converted ICL size larger than the STS, and the “under-sizing group” as having a pre-converted ICL size smaller than the STS. Refractive outcomes, safety and parameters related to postoperative vault were compared between the two groups. The value of “actual ICL size – STS” differed significantly between the normal-sizing and under-sizing groups (p < 0.001), but postoperative vault did not differ significantly (p = 0.442). The demographics, implanted ICL characteristics, effectiveness indexes, safety indexes, and parameters related to postoperative vault did not differ significantly between the two groups (p > 0.05). Two patients in the normal-sizing group exhibited over-vaulting; these patients had shallow anterior chambers and were implanted with high-dioptric-power ICLs. The achievement of acceptable vault in both normal-sizing and under-sizing groups indicates the existence of a buffering zone in V4c ICL sizing. The smaller size of V4c ICLs should be considered in patients susceptible to over-vaulting, such as those with shallow anterior chambers and high-dioptric-power ICLs.
- 22 December 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 260
Open AccessBuffering zone of implantable Collamer lens sizing in V4c
The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), and the V4 ICL sizes were then converted to V4c ICL sizes with a size-converting table. We defined the “normal-sizing group” as having a pre-converted ICL size larger than the STS, and the “under-sizing group” as having a pre-converted ICL size smaller than the STS. Refractive outcomes, safety and parameters related to postoperative vault were compared between the two groups. The value of “actual ICL size – STS” differed significantly between the normal-sizing and under-sizing groups (p < 0.001), but postoperative vault did not differ significantly (p = 0.442). The demographics, implanted ICL characteristics, effectiveness indexes, safety indexes, and parameters related to postoperative vault did not differ significantly between the two groups (p > 0.05). Two patients in the normal-sizing group exhibited over-vaulting; these patients had shallow anterior chambers and were implanted with high-dioptric-power ICLs. The achievement of acceptable vault in both normal-sizing and under-sizing groups indicates the existence of a buffering zone in V4c ICL sizing. The smaller size of V4c ICLs should be considered in patients susceptible to over-vaulting, such as those with shallow anterior chambers and high-dioptric-power ICLs.
- Open Access
- 28 August 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (8) , e0183335
A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL) : V4 versus V4c
To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL™(TICL);V4 and V4c, STAAR Surgical Co.) Retrospective case series. This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17±3.31° and 3.39±2.36° in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
- 28 August 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (8) , e0183335
Open AccessA comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL) : V4 versus V4c
To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL™(TICL);V4 and V4c, STAAR Surgical Co.) Retrospective case series. This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17±3.31° and 3.39±2.36° in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
- Open Access
- 24 August 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-9
Comparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation
To evaluate and compare the astigmatism prediction errors taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens (IOL) implantation. Phacoemulsification with toric Precizon IOL implantation was performed in 41 eyes with corneal astigmatism (range, 1 to 5 diopters (D)) determined by IOLMaster and SimK on Pentacam. Preoperative corneal astigmatism measurements were obtained from IOLMaster readings (IOLMaster, Baylor-IOLMaster, and Barrett-IOLMaster) and Pentacam readings (SimK, Baylor-SimK, Barrett-SimK, wavefront, true net power, total corneal refractive power, and vector derived by manual vector summation using corneal front and back astigmatism). Prediction error and intraclass correlation coefficient (ICC) between the measured (or calculated) astigmatism by IOLMaster and Pentacam and the estimated corneal astigmatism estimated by IOL toricity power and residual astigmatism were determined. The centroid errors in prediction error with IOLMaster, SimK, Baylor-IOLMaster, Baylor-SimK, Barrett-IOLMaster, Barrett-SimK, wavefront, true net power, total corneal refractive power, and vector were 0.59@103, 0.61 @103, 0.37@161, 0.41@162, 0.24@171, 0.36@162, 0.42@106, 0.04@8, 0.07@82, and 0.03@82, respectively, in with-the-rule (WTR) astigmatism eyes at postoperative 3-month. They were 0.22@87, 0.20@74, 0.16@21, 0.54@10, 0.43@3, 0.33@19, 0.51@25, 0.31@58, 0.29@50, and 0.14@50 in against-the-rule (ATR) astigmatism eyes. Of the ten modalities, vector showed the lowest WTR astigmatism prediction error and the highest ICC between the predicted and the estimated corneal astigmatism for both WTR and ATR eyes. Vector summation using anterior and posterior corneal surface power taken with the Pentacam yields the least astigmatism prediction error and is a promising tool for determining toric IOL cylinder power.
- 24 August 2017
- Published by Springer Nature in BMC Ophthalmology
- Vol. 17 (1) , 1-9
Open AccessComparison of astigmatism prediction error taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens implantation
To evaluate and compare the astigmatism prediction errors taken with the Pentacam measurements, Baylor nomogram, and Barrett formula for toric intraocular lens (IOL) implantation. Phacoemulsification with toric Precizon IOL implantation was performed in 41 eyes with corneal astigmatism (range, 1 to 5 diopters (D)) determined by IOLMaster and SimK on Pentacam. Preoperative corneal astigmatism measurements were obtained from IOLMaster readings (IOLMaster, Baylor-IOLMaster, and Barrett-IOLMaster) and Pentacam readings (SimK, Baylor-SimK, Barrett-SimK, wavefront, true net power, total corneal refractive power, and vector derived by manual vector summation using corneal front and back astigmatism). Prediction error and intraclass correlation coefficient (ICC) between the measured (or calculated) astigmatism by IOLMaster and Pentacam and the estimated corneal astigmatism estimated by IOL toricity power and residual astigmatism were determined. The centroid errors in prediction error with IOLMaster, SimK, Baylor-IOLMaster, Baylor-SimK, Barrett-IOLMaster, Barrett-SimK, wavefront, true net power, total corneal refractive power, and vector were 0.59@103, 0.61 @103, 0.37@161, 0.41@162, 0.24@171, 0.36@162, 0.42@106, 0.04@8, 0.07@82, and 0.03@82, respectively, in with-the-rule (WTR) astigmatism eyes at postoperative 3-month. They were 0.22@87, 0.20@74, 0.16@21, 0.54@10, 0.43@3, 0.33@19, 0.51@25, 0.31@58, 0.29@50, and 0.14@50 in against-the-rule (ATR) astigmatism eyes. Of the ten modalities, vector showed the lowest WTR astigmatism prediction error and the highest ICC between the predicted and the estimated corneal astigmatism for both WTR and ATR eyes. Vector summation using anterior and posterior corneal surface power taken with the Pentacam yields the least astigmatism prediction error and is a promising tool for determining toric IOL cylinder power.
- Open Access
- 26 October 2013
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 4 (3) , 210-215
Traumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation
We present the first case of partial aniridia, traumatic cataract, and peripapillary subretinal hemorrhage after blunt trauma to an eye containing a foldable iris-fixated phakic intraocular lens (pIOL). Although the patient experienced visual loss because of considerable corneal astigmatism and a traumatic cataract, vision was recovered by a 2-stage primary corneal repair and cataract surgery with a toric intraocular lens. This case exhibits clinical manifestations that differ from previously reported trauma of a non-foldable iris-fixated pIOL. A relatively small corneal incision and a large optic diameter of Artiflex pIOLs may prevent posttraumatic total expulsion of intraocular tissues and present different clinical features from the case of non-foldable pIOLs (Artisan). Although the extent of the damage is different, the possibility of aniridia and traumatic cataract exists in eyes with both foldable and non-foldable iris-fixated pIOLs.
- 26 October 2013
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 4 (3) , 210-215
Open AccessTraumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation
We present the first case of partial aniridia, traumatic cataract, and peripapillary subretinal hemorrhage after blunt trauma to an eye containing a foldable iris-fixated phakic intraocular lens (pIOL). Although the patient experienced visual loss because of considerable corneal astigmatism and a traumatic cataract, vision was recovered by a 2-stage primary corneal repair and cataract surgery with a toric intraocular lens. This case exhibits clinical manifestations that differ from previously reported trauma of a non-foldable iris-fixated pIOL. A relatively small corneal incision and a large optic diameter of Artiflex pIOLs may prevent posttraumatic total expulsion of intraocular tissues and present different clinical features from the case of non-foldable pIOLs (Artisan). Although the extent of the damage is different, the possibility of aniridia and traumatic cataract exists in eyes with both foldable and non-foldable iris-fixated pIOLs.