Thomas P. Burg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Thomas P. Burg has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Andreas Dietzel
Technische Universität Braunschweig Institute of Microtechnology Alte Salzdahlumer Str. 203 38124 Braunschweig Germany
1 shared publication- Giovanni Marco Nocera
Telethon Institute of Genetics and Medicine (TIGEM), Pozzuoli, Italy
1 shared publication Heike Bunjes
Technische Universität Braunschweig Institut für Pharmazeutische Technologie und Biopharmazie Mendelssohnstr. 1 38106 Braunschweig Germany
1 shared publicationHolger Bolze
Max Planck Institute for Biophysical Chemistry Research Group Biological Micro- and Nanotechnology Am Fassberg 11 37077 Göttingen Germany
1 shared publicationJan-Erik Messling
Max Planck Institute for Biophysical Chemistry, Am Fassberg 11, 37077, Göttingen, Germany
1 shared publication- Juergen M. Plitzko
Research Group CryoEM Technology, Max Planck Institute of Biochemistry
1 shared publication
Latest Publications
- Open Access
- 29 December 2020
- Published by Wiley in Chemical Engineering & Technology
- Vol. 44 (3) , 457-464
Protective Filtration for Microfluidic Nanoparticle Precipitation for Pharmaceutical Applications
- 29 December 2020
- Published by Wiley in Chemical Engineering & Technology
- Vol. 44 (3) , 457-464
Open AccessProtective Filtration for Microfluidic Nanoparticle Precipitation for Pharmaceutical Applications
- Open Access
- 13 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
In situ Microfluidic Cryofixation for Cryo Focused Ion Beam Milling and Cryo Electron Tomography
We present a microfluidic platform for studying structure-function relationships at the cellular level by connecting video rate live cell imaging with in situ microfluidic cryofixation and cryo-electron tomography of near natively preserved, unstained specimens. Correlative light and electron microscopy (CLEM) has been limited by the time required to transfer live cells from the light microscope to dedicated cryofixation instruments, such as a plunge freezer or high-pressure freezer. We recently demonstrated a microfluidic based approach that enables sample cryofixation directly in the light microscope with millisecond time resolution, a speed improvement of up to three orders of magnitude. Here we show that this cryofixation method can be combined with cryo-electron tomography (cryo-ET) by using Focused Ion Beam milling at cryogenic temperatures (cryo-FIB) to prepare frozen hydrated electron transparent sections. To make cryo-FIB sectioning of rapidly frozen microfluidic channels achievable, we developed a sacrificial layer technique to fabricate microfluidic devices with a PDMS bottom wall Caenorhabditis elegans roundworms L1 larvae during live imaging in the light microscope, followed by cryo-FIB milling and lift out to produce thin, electron transparent sections for cryo-ET imaging. Cryo-ET analysis of initial results show that the structural preservation of the cryofixed C. elegans was suitable for high resolution cryo-ET work. The combination of cryofixation during live imaging enabled by microfluidic cryofixation with the molecular resolution capabilities of cryo-ET offers an exciting avenue to further advance space-time correlative light and electron microscopy (st-CLEM) for investigation of biological processes at high resolution in four dimensions.
- 13 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-10
Open AccessIn situ Microfluidic Cryofixation for Cryo Focused Ion Beam Milling and Cryo Electron Tomography
We present a microfluidic platform for studying structure-function relationships at the cellular level by connecting video rate live cell imaging with in situ microfluidic cryofixation and cryo-electron tomography of near natively preserved, unstained specimens. Correlative light and electron microscopy (CLEM) has been limited by the time required to transfer live cells from the light microscope to dedicated cryofixation instruments, such as a plunge freezer or high-pressure freezer. We recently demonstrated a microfluidic based approach that enables sample cryofixation directly in the light microscope with millisecond time resolution, a speed improvement of up to three orders of magnitude. Here we show that this cryofixation method can be combined with cryo-electron tomography (cryo-ET) by using Focused Ion Beam milling at cryogenic temperatures (cryo-FIB) to prepare frozen hydrated electron transparent sections. To make cryo-FIB sectioning of rapidly frozen microfluidic channels achievable, we developed a sacrificial layer technique to fabricate microfluidic devices with a PDMS bottom wall Caenorhabditis elegans roundworms L1 larvae during live imaging in the light microscope, followed by cryo-FIB milling and lift out to produce thin, electron transparent sections for cryo-ET imaging. Cryo-ET analysis of initial results show that the structural preservation of the cryofixed C. elegans was suitable for high resolution cryo-ET work. The combination of cryofixation during live imaging enabled by microfluidic cryofixation with the molecular resolution capabilities of cryo-ET offers an exciting avenue to further advance space-time correlative light and electron microscopy (st-CLEM) for investigation of biological processes at high resolution in four dimensions.