Yuzhong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yuzhong Zhang has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Shuangbao Shu
Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei 230009, China
10 shared publications Tengda Zhang
6 shared publicationsShuangbao Shu
School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Hefei, 230009, People’s Republic of China
5 shared publicationsXianli Lang
5 shared publicationsHuajun Liang
Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology 1 , Hefei 230009, China
4 shared publicationsHaibing Hu
3 shared publications
Latest Publications
- 7 July 2026
- Published by Elsevier in Measurement
- Vol. 287
A multi-scale temporal fusion and local attention network for subsurface defects detection in long pulse thermography
- 7 July 2026
- Published by Elsevier in Measurement
- Vol. 287
A multi-scale temporal fusion and local attention network for subsurface defects detection in long pulse thermography
- 17 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 10919
MSPANet: a multi-scale phase-aware network for spatial phase unwrapping via fringe order classification
This paper presents a multi-scale phase-aware network (MSPANet) for spatial phase unwrapping in structured-light three-dimensional (3D) reconstruction. Fringe-order estimation is formulated as a semantic segmentation problem to avoid error accumulation and integer constraints inherent in regression-based approaches. Guided by the physical characteristics of wrapped-phase propagation, MSPANet integrates parallel multi-scale feature extraction with dilated convolution, learnable edge enhancement, and a phase-aware gating module to handle periodic 2π discontinuities. A hybrid loss function incorporating continuity, edge alignment, and regional consistency further enforces physically plausible predictions. Extensive experiments on simulated and real-world datasets demonstrate that MSPANet achieves robust and accurate phase unwrapping under noise and discontinuities, supporting reliable 3D shape measurement in complex scenarios.
- 17 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 10919
MSPANet: a multi-scale phase-aware network for spatial phase unwrapping via fringe order classification
This paper presents a multi-scale phase-aware network (MSPANet) for spatial phase unwrapping in structured-light three-dimensional (3D) reconstruction. Fringe-order estimation is formulated as a semantic segmentation problem to avoid error accumulation and integer constraints inherent in regression-based approaches. Guided by the physical characteristics of wrapped-phase propagation, MSPANet integrates parallel multi-scale feature extraction with dilated convolution, learnable edge enhancement, and a phase-aware gating module to handle periodic 2π discontinuities. A hybrid loss function incorporating continuity, edge alignment, and regional consistency further enforces physically plausible predictions. Extensive experiments on simulated and real-world datasets demonstrate that MSPANet achieves robust and accurate phase unwrapping under noise and discontinuities, supporting reliable 3D shape measurement in complex scenarios.
- 1 October 2025
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 68 (5) , 851-861
Multi-spectral Radiation Temperature Inversion Method Based on the Statistical Distribution of the Predicted Temperature
Accurate temperature measurement is essential for quality control and industrial process optimization. However, a major challenge in the temperature measurement arises when the emissivity of the object is unknown. Multi-wavelength temperature measurement has emerged as an effective solution to address this issue, as it allows for the simultaneous consideration of multiple wavelengths, compensating for unknown emissivity variations. In this work, a novel multi-wavelength radiation temperature inversion algorithm is proposed for the simultaneous determination of both the target temperature and spectral emissivity. This method is based on the assumption that the spectral emissivity of the object follows an exponential polynomial model. By utilizing different wavelength combinations, multiple overdetermined equations are constructed and the conjugate gradient least squares method is employed to solve these equations to obtain predicted temperatures. After acquiring multiple predicted temperatures, the adaptive kernel density estimation method is applied to model the probability density distribution of the predicted temperatures. Finally, the final temperature prediction is determined as the weighted average of all temperatures above a predefined threshold and emissivity is further obtained based on the final predicted temperature. The accuracy and reliability of this method are validated through simulation experiments under different emissivity models, as well as actual emissivity measurement data from four samples, and experimental results demonstrate that the method can offer a promising solution for overcoming the challenges associated with the traditional temperature measurement techniques.
- 1 October 2025
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 68 (5) , 851-861
Multi-spectral Radiation Temperature Inversion Method Based on the Statistical Distribution of the Predicted Temperature
Accurate temperature measurement is essential for quality control and industrial process optimization. However, a major challenge in the temperature measurement arises when the emissivity of the object is unknown. Multi-wavelength temperature measurement has emerged as an effective solution to address this issue, as it allows for the simultaneous consideration of multiple wavelengths, compensating for unknown emissivity variations. In this work, a novel multi-wavelength radiation temperature inversion algorithm is proposed for the simultaneous determination of both the target temperature and spectral emissivity. This method is based on the assumption that the spectral emissivity of the object follows an exponential polynomial model. By utilizing different wavelength combinations, multiple overdetermined equations are constructed and the conjugate gradient least squares method is employed to solve these equations to obtain predicted temperatures. After acquiring multiple predicted temperatures, the adaptive kernel density estimation method is applied to model the probability density distribution of the predicted temperatures. Finally, the final temperature prediction is determined as the weighted average of all temperatures above a predefined threshold and emissivity is further obtained based on the final predicted temperature. The accuracy and reliability of this method are validated through simulation experiments under different emissivity models, as well as actual emissivity measurement data from four samples, and experimental results demonstrate that the method can offer a promising solution for overcoming the challenges associated with the traditional temperature measurement techniques.
- 10 July 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 076113
Complementary feature fusion network for few-shot segmentation of steel surface defect
Steel surface defect segmentation plays a critical role in improving production efficiency and ensuring product quality traceability. However, existing segmentation networks, which depend on large amounts of labeled samples for training, still face challenges in segmenting certain sparse defect types. To address this, a multi-source fusion framework is proposed in this work for few-shot segmentation of steel surface defects. This framework proposes a multi-source complementary information extraction module that integrates global-local semantics and cross-region interactions between support and query features, enabling accurate capture of complex structures and variations in images. Meanwhile, a multi-scale spatial-channel attention module is introduced to highlight foreground defect semantics while suppressing irrelevant background noise in support features. Finally, a multi-source information fusion module is proposed to consolidate these complementary features with the query feature and the support prototype for generating a comprehensive defect representation. Additionally, a support decoder is integrated into the framework to generate the auxiliary support mask prediction, while a dual-loss training strategy is employed to bridge the gap between query and support features learning. Comparative experiments against state-of-the-art methods on the FSSD-12 dataset demonstrate that our framework achieves the best segmentation performance, outperforming the second-best model by 2.9% (1-shot) and 3.4% (5-shot) in mean intersection over union (mIoU), with corresponding foreground-background-IoU (FB-IoU) gains of 1.3% and 2.5%. Meanwhile, ablation studies validate the synergistic contributions of our proposed modules, showing that our full model surpasses the baseline by 14.2%/11.9% in mIoU and 12.8%/7.2% in FB-IoU improvement for 1-shot/5-shot settings, respectively.
- 10 July 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 076113
Complementary feature fusion network for few-shot segmentation of steel surface defect
Steel surface defect segmentation plays a critical role in improving production efficiency and ensuring product quality traceability. However, existing segmentation networks, which depend on large amounts of labeled samples for training, still face challenges in segmenting certain sparse defect types. To address this, a multi-source fusion framework is proposed in this work for few-shot segmentation of steel surface defects. This framework proposes a multi-source complementary information extraction module that integrates global-local semantics and cross-region interactions between support and query features, enabling accurate capture of complex structures and variations in images. Meanwhile, a multi-scale spatial-channel attention module is introduced to highlight foreground defect semantics while suppressing irrelevant background noise in support features. Finally, a multi-source information fusion module is proposed to consolidate these complementary features with the query feature and the support prototype for generating a comprehensive defect representation. Additionally, a support decoder is integrated into the framework to generate the auxiliary support mask prediction, while a dual-loss training strategy is employed to bridge the gap between query and support features learning. Comparative experiments against state-of-the-art methods on the FSSD-12 dataset demonstrate that our framework achieves the best segmentation performance, outperforming the second-best model by 2.9% (1-shot) and 3.4% (5-shot) in mean intersection over union (mIoU), with corresponding foreground-background-IoU (FB-IoU) gains of 1.3% and 2.5%. Meanwhile, ablation studies validate the synergistic contributions of our proposed modules, showing that our full model surpasses the baseline by 14.2%/11.9% in mIoU and 12.8%/7.2% in FB-IoU improvement for 1-shot/5-shot settings, respectively.
- 19 December 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 016197
An adaptive feature refinement network for pixel-level segmentation of surface defect
In the field of industrial production, automatic surface defect segmentation plays a crucial role in improving product quality and production efficiency. However, due to the interference of complex backgrounds and uneven illumination, efficient and accurate segmentation of surface defect remains a significant challenge. To address these issues, this work proposes an adaptive feature refinement (AFR) U-shaped network (U-Net) for pixel-level segmentation of surface defect. The proposed framework draws inspiration from the classic U-Net architecture, and the pre-trained EfficientNet-B0 is selected as the encoder part to extract the multi-scale context information. Then, a novel AFR module, which further learns the global channel-wise dependencies and captures cross-channel local spatial patterns from multi-level features, is introduced to enhance the robustness of feature representation. Finally, these enhanced encoder features are up-sampled, and are further fed into the decoder part to obtain pixel-level defect segmentation results. To assess the validity and accuracy of the proposed model, this network is validated through extensive experiments on four different types of defect datasets. Experimental results show that the proposed model performs well on these datasets, with the maximum mean intersection over union (MIoU) of 91.63%. Meanwhile, the model is compared with some U-Net-based models and other state-of-the-art segmentation models, and it can also achieve competitive performance on MIoU scores. With the acceleration of the graphics processing unit, the proposed network can achieve a detection speed of 82 fps, which can meet the needs of real-time detection in the industrial fields.
- 19 December 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 016197
An adaptive feature refinement network for pixel-level segmentation of surface defect
In the field of industrial production, automatic surface defect segmentation plays a crucial role in improving product quality and production efficiency. However, due to the interference of complex backgrounds and uneven illumination, efficient and accurate segmentation of surface defect remains a significant challenge. To address these issues, this work proposes an adaptive feature refinement (AFR) U-shaped network (U-Net) for pixel-level segmentation of surface defect. The proposed framework draws inspiration from the classic U-Net architecture, and the pre-trained EfficientNet-B0 is selected as the encoder part to extract the multi-scale context information. Then, a novel AFR module, which further learns the global channel-wise dependencies and captures cross-channel local spatial patterns from multi-level features, is introduced to enhance the robustness of feature representation. Finally, these enhanced encoder features are up-sampled, and are further fed into the decoder part to obtain pixel-level defect segmentation results. To assess the validity and accuracy of the proposed model, this network is validated through extensive experiments on four different types of defect datasets. Experimental results show that the proposed model performs well on these datasets, with the maximum mean intersection over union (MIoU) of 91.63%. Meanwhile, the model is compared with some U-Net-based models and other state-of-the-art segmentation models, and it can also achieve competitive performance on MIoU scores. With the acceleration of the graphics processing unit, the proposed network can achieve a detection speed of 82 fps, which can meet the needs of real-time detection in the industrial fields.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
A correction method for radial distortion and nonlinear response of infrared cameras
The key feature of non-contact temperature measurement provided by infrared (IR) cameras underpins their versatility. However, the accuracy of temperature measurements with IR cameras depends on imaging quality due to their non-contact nature, such as the lens, body temperature, and measurement environment. This paper addresses the correction of radial distortion and nonlinear response issues in IR cameras. To address radial distortion, we have designed a passive checkerboard calibration board specifically for infrared cameras. This board is used to calibrate the IR camera and derive the necessary camera parameters. Subsequently, these parameters are applied during the actual measurement process to rectify radial distortion effectively. Building on the radial distortion correction method mentioned above, we propose a multi-point segmented calibration approach that considers different temperature ranges and imaging regions. This method alleviates the issue of reduced temperature measurement accuracy due to variations in camera responses by computing gain and offset coefficient matrices for each temperature range. Experimental results demonstrate the effectiveness of the calibration board in correcting radial distortion in IR cameras, with a mean reprojection error of less than 0.16 pixels. Regarding the nonlinear response problem, the introduced method significantly reduces the relative error in temperature measurement. In the verification phase, spanning from 100 to 500 °C, the average relative error in temperature measurement decreases by 0.49% from 1.61% before and after correction, which highlights a substantial improvement in temperature measurement accuracy. This work gives a useful reference to improve the imaging quality and temperature measurement accuracy using infrared cameras.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
A correction method for radial distortion and nonlinear response of infrared cameras
The key feature of non-contact temperature measurement provided by infrared (IR) cameras underpins their versatility. However, the accuracy of temperature measurements with IR cameras depends on imaging quality due to their non-contact nature, such as the lens, body temperature, and measurement environment. This paper addresses the correction of radial distortion and nonlinear response issues in IR cameras. To address radial distortion, we have designed a passive checkerboard calibration board specifically for infrared cameras. This board is used to calibrate the IR camera and derive the necessary camera parameters. Subsequently, these parameters are applied during the actual measurement process to rectify radial distortion effectively. Building on the radial distortion correction method mentioned above, we propose a multi-point segmented calibration approach that considers different temperature ranges and imaging regions. This method alleviates the issue of reduced temperature measurement accuracy due to variations in camera responses by computing gain and offset coefficient matrices for each temperature range. Experimental results demonstrate the effectiveness of the calibration board in correcting radial distortion in IR cameras, with a mean reprojection error of less than 0.16 pixels. Regarding the nonlinear response problem, the introduced method significantly reduces the relative error in temperature measurement. In the verification phase, spanning from 100 to 500 °C, the average relative error in temperature measurement decreases by 0.49% from 1.61% before and after correction, which highlights a substantial improvement in temperature measurement accuracy. This work gives a useful reference to improve the imaging quality and temperature measurement accuracy using infrared cameras.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Photothermal vortex interferometer with azimuthal complex spectra analysis for the measurement of laser-induced nanoscale thermal lens dynamics
A photothermal vortex interferometer (PTVI) is proposed to fill the gap of full-field measurement of the laser-induced nanoscale thermal lens dynamics of optical elements. The PTVI produces a multi-ring petal-like interferogram by the coaxial coherent superposition of the high-order conjugated Laguerre–Gaussian beams. The non-uniform optical path change (OPC) profile resulting from the thermal lens causes the petals of the interferogram at the different radii to shift by the different azimuths. To demodulate such an interferogram, an azimuthal complex spectra analysis is presented by using a camera with a pixelated multi-ring pattern written on its sensor to extract multiple azimuthal intensity profiles synchronously from the interferogram. Therefore, the OPC profile can be determined dynamically from the complex spectra of the azimuthal intensity profiles at the main frequency components. An analytical thermophysical model of the thermal lens is given, and the basic principle of the azimuthal complex spectra analysis is revealed. A proof-of-concept experiment is demonstrated using a N-BK7 glass sample heated by a pump laser. The results verified that the PTVI achieves the measurement accuracy of 47 pm with a standard deviation of 358 pm (3σ) and can be used for full-field measurement of the nanoscale OPC profile caused by the thermal lens dynamics. Due to the picometer-scale accuracy of the PTVI, the absorption coefficient and thermal diffusivity of the glass sample were determined to be A0 = 0.126 m−1 and D = 5.63 × 10−7 m2 s−1, respectively, which agree with the nominal ones of A0 = 0.129 m−1 and D = 5.17 × 10−7 m2 s−1. Although the PTVI is only suitable for measuring the rotationally symmetric OPC, it shows less computation burden and hardware complexity, and it is proved to be a highly sensitive and effective tool in studying optical, thermo-physical, and mechanical properties of optical elements.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessPhotothermal vortex interferometer with azimuthal complex spectra analysis for the measurement of laser-induced nanoscale thermal lens dynamics
A photothermal vortex interferometer (PTVI) is proposed to fill the gap of full-field measurement of the laser-induced nanoscale thermal lens dynamics of optical elements. The PTVI produces a multi-ring petal-like interferogram by the coaxial coherent superposition of the high-order conjugated Laguerre–Gaussian beams. The non-uniform optical path change (OPC) profile resulting from the thermal lens causes the petals of the interferogram at the different radii to shift by the different azimuths. To demodulate such an interferogram, an azimuthal complex spectra analysis is presented by using a camera with a pixelated multi-ring pattern written on its sensor to extract multiple azimuthal intensity profiles synchronously from the interferogram. Therefore, the OPC profile can be determined dynamically from the complex spectra of the azimuthal intensity profiles at the main frequency components. An analytical thermophysical model of the thermal lens is given, and the basic principle of the azimuthal complex spectra analysis is revealed. A proof-of-concept experiment is demonstrated using a N-BK7 glass sample heated by a pump laser. The results verified that the PTVI achieves the measurement accuracy of 47 pm with a standard deviation of 358 pm (3σ) and can be used for full-field measurement of the nanoscale OPC profile caused by the thermal lens dynamics. Due to the picometer-scale accuracy of the PTVI, the absorption coefficient and thermal diffusivity of the glass sample were determined to be A0 = 0.126 m−1 and D = 5.63 × 10−7 m2 s−1, respectively, which agree with the nominal ones of A0 = 0.129 m−1 and D = 5.17 × 10−7 m2 s−1. Although the PTVI is only suitable for measuring the rotationally symmetric OPC, it shows less computation burden and hardware complexity, and it is proved to be a highly sensitive and effective tool in studying optical, thermo-physical, and mechanical properties of optical elements.
- 1 November 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (11) , T11002
Detection of flat-bottom holes in composite materials using multi-dimensional complementary ensemble empirical mode decomposition algorithm
Due to high-temperature resistance, high strength, and excellent fatigue resistance, composite materials are widely used in automotive manufacturing, aerospace, infrastructure and other fields. Consequently, the demand for defect detection of composite materials is also increasing. As a non-destructive testing technique, the active infrared thermography, which can achieve full-field defect detection, is suitable for defect detection of composite materials. However, this method is susceptible to noises caused by the environment and heating sources. In order to solve the problem of the defect signal being submerged by these noises, a multi-dimensional complementary ensemble empirical mode decomposition (MCEEMD) algorithm is introduced in this paper. This method can decompose the signal into the low-frequency background noise, the high-frequency heating noise, and useful defect signals, and these noises can be easily removed to improve the contrast to noise ratio (CNR) of defect images. Based on this proposed method, a defect detection experiment on the carbon fiber reinforced plastic (CFRP) is performed in this paper, and experimental results show that the method can effectively remove environmental noise and heating noise, and it can detect 11 out of 12 defects on the CFRP sample with an average CNR of 9.107. Compared with the traditional differential absolute contrast method, this method can detect one additional small defect with the aspect ratio of 1.67 and one deep defect with a depth of 2 mm.
- 1 November 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (11) , T11002
Detection of flat-bottom holes in composite materials using multi-dimensional complementary ensemble empirical mode decomposition algorithm
Due to high-temperature resistance, high strength, and excellent fatigue resistance, composite materials are widely used in automotive manufacturing, aerospace, infrastructure and other fields. Consequently, the demand for defect detection of composite materials is also increasing. As a non-destructive testing technique, the active infrared thermography, which can achieve full-field defect detection, is suitable for defect detection of composite materials. However, this method is susceptible to noises caused by the environment and heating sources. In order to solve the problem of the defect signal being submerged by these noises, a multi-dimensional complementary ensemble empirical mode decomposition (MCEEMD) algorithm is introduced in this paper. This method can decompose the signal into the low-frequency background noise, the high-frequency heating noise, and useful defect signals, and these noises can be easily removed to improve the contrast to noise ratio (CNR) of defect images. Based on this proposed method, a defect detection experiment on the carbon fiber reinforced plastic (CFRP) is performed in this paper, and experimental results show that the method can effectively remove environmental noise and heating noise, and it can detect 11 out of 12 defects on the CFRP sample with an average CNR of 9.107. Compared with the traditional differential absolute contrast method, this method can detect one additional small defect with the aspect ratio of 1.67 and one deep defect with a depth of 2 mm.
- 1 May 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (05) , T05005
Normal spectral emissivity characteristics of tungsten in the mid-infrared region
Tungsten is an important material constituting the first wall of the Experimental Advanced Superconducting Tokamak due to its excellent corrosion resistance. The temperature distribution of the first wall during the discharge process are the key to ensuring the safe and stable operation of the EAST. Therefore, it is necessary to explore the dependence of material emissivity on temperature and wavelength for improving temperature measurement accuracy. This work quantitatively explores the normal spectral emissivity of tungsten within the 3 μm to 5 μm in the temperature range between 100°C and 500°C based on the Fourier transform infrared spectrometer. The dependence of emissivity on wavelength and temperature are experimentally analyzed, and the possible functional relationship between the emissivity of tungsten and the surface temperature and the wavelength are established respectively. This work could lay the foundation for the application of multi-wavelength thermometry on temperature measurement of the first wall of the EAST.
- 1 May 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (05) , T05005
Normal spectral emissivity characteristics of tungsten in the mid-infrared region
Tungsten is an important material constituting the first wall of the Experimental Advanced Superconducting Tokamak due to its excellent corrosion resistance. The temperature distribution of the first wall during the discharge process are the key to ensuring the safe and stable operation of the EAST. Therefore, it is necessary to explore the dependence of material emissivity on temperature and wavelength for improving temperature measurement accuracy. This work quantitatively explores the normal spectral emissivity of tungsten within the 3 μm to 5 μm in the temperature range between 100°C and 500°C based on the Fourier transform infrared spectrometer. The dependence of emissivity on wavelength and temperature are experimentally analyzed, and the possible functional relationship between the emissivity of tungsten and the surface temperature and the wavelength are established respectively. This work could lay the foundation for the application of multi-wavelength thermometry on temperature measurement of the first wall of the EAST.
- 21 April 2023
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 45 (14) , 2739-2747
Measurement performance evaluation and noise compensation for a Fourier transform infrared–based pyrometer
The Fourier transform infrared (FTIR) spectrometer is widely used for spectrum analysis and radiation intensity measurement. In this work, a pyrometer with the temperature measurement range of 800°C to 1200°C is developed based on the FTIR spectrometer, and the calibration of the instrument coefficients using a standard radiation source is performed. On this basis, the readout noise and shot noise in the spectral signal are analyzed, and a detailed quantitative evaluation of the influences of two kinds of noise on the temperature measurement accuracy is also carried out in this work. Experimental results show that the temperature deviation caused by the two kinds of noise is less than 1°C when the wavelength is within the range of 2.0 to 5.4 μm. However, when the wavelength is greater than 5.4 μm, the maximum temperature deviation caused by the readout noise and shot noise can reach about 12°C and 18°C, respectively. In view of this, a Kalman filter method is introduced in this work to reduce temperature fluctuations caused by these noises, where the maximum fluctuation can be reduced from 83.9°C to 6.1°C with this filter method. These experimental results can provide a valuable guidance for the general-purpose calibration and assessment of the FTIR-based pyrometer.
- 21 April 2023
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 45 (14) , 2739-2747
Measurement performance evaluation and noise compensation for a Fourier transform infrared–based pyrometer
The Fourier transform infrared (FTIR) spectrometer is widely used for spectrum analysis and radiation intensity measurement. In this work, a pyrometer with the temperature measurement range of 800°C to 1200°C is developed based on the FTIR spectrometer, and the calibration of the instrument coefficients using a standard radiation source is performed. On this basis, the readout noise and shot noise in the spectral signal are analyzed, and a detailed quantitative evaluation of the influences of two kinds of noise on the temperature measurement accuracy is also carried out in this work. Experimental results show that the temperature deviation caused by the two kinds of noise is less than 1°C when the wavelength is within the range of 2.0 to 5.4 μm. However, when the wavelength is greater than 5.4 μm, the maximum temperature deviation caused by the readout noise and shot noise can reach about 12°C and 18°C, respectively. In view of this, a Kalman filter method is introduced in this work to reduce temperature fluctuations caused by these noises, where the maximum fluctuation can be reduced from 83.9°C to 6.1°C with this filter method. These experimental results can provide a valuable guidance for the general-purpose calibration and assessment of the FTIR-based pyrometer.