Mayumi Higashi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mayumi Higashi has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Katsuyoshi Ito
Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
13 shared publications - Masahiro Tanabe
Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
12 shared publications Masahiro Tanabe
Department of Radiology, Yamaguchi University Graduate School of Medicine , Ube, Yamaguchi 755-8505
5 shared publicationsEtsushi Iida
Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
4 shared publicationsKatsuyoshi Ito
Department of Radiology, Yamaguchi University Graduate School of Medicine , Ube, Yamaguchi 755-8505
4 shared publicationsMatakazu Furukawa
Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
4 shared publications
Latest Publications
- Open Access
- 7 August 2026
- Published by MDPI AG in Tomography
- Vol. 12 (8) , 112
Factors Affecting Temporal Changes in Ablated Liver Volume After Radiofrequency Ablation for Hepatocellular Carcinoma Evaluated by Three-Dimensional Volumetric Computed Tomography
Objectives: To evaluate associations between shrinkage of ablated liver area on computed tomography (CT) over time after radiofrequency ablation (RFA) and clinical parameters related to liver function and fibrosis. Methods: Patients with hepatocellular carcinoma who underwent RFA and follow-up CT were retrospectively reviewed. The ablated area volume (AAV) on CT obtained within 1 week and around 6 months after RFA was measured, and reduction rate of AAV was calculated. The AAV reduction rate was compared among Child-Pugh classification, modified albumin-bilirubin (mALBI) grades, FIB-4 index categories, and lesion locations using generalized estimating equations (GEE). Univariable and multivariable GEE analyses were performed to evaluate associations between the AAV reduction rate and clinical parameters. Results: Fifty-three lesions in 41 patients (median age, 76 [range, 38–88] years, 24 men) were evaluated. The AAV reduction rate was significantly lower in Child-Pugh class B than class A (p < 0.001) and in mALBI grade 2b than grade 1 (p < 0.001) or grade 2a (p = 0.004). Significant differences were also observed among FIB-4 index groups (p < 0.001) and among lesion locations, with lower AAV reduction rates in medial and anterior segments than in lateral (p < 0.001) and posterior (p = 0.017) segments. Univariable GEE analyses showed significant associations between AAV reduction rate and cholinesterase, albumin, total bilirubin (T-Bil), prothrombin time, platelet count, and FIB-4 index (p < 0.05). Multivariable GEE analysis demonstrated that both albumin and T-Bil remained independently associated with AAV reduction rate (p < 0.001). Conclusions: The AAV reduction rate tended to be lower in patients with impaired liver function and advanced liver fibrosis.
- 7 August 2026
- Published by MDPI AG in Tomography
- Vol. 12 (8) , 112
Open AccessFactors Affecting Temporal Changes in Ablated Liver Volume After Radiofrequency Ablation for Hepatocellular Carcinoma Evaluated by Three-Dimensional Volumetric Computed Tomography
Objectives: To evaluate associations between shrinkage of ablated liver area on computed tomography (CT) over time after radiofrequency ablation (RFA) and clinical parameters related to liver function and fibrosis. Methods: Patients with hepatocellular carcinoma who underwent RFA and follow-up CT were retrospectively reviewed. The ablated area volume (AAV) on CT obtained within 1 week and around 6 months after RFA was measured, and reduction rate of AAV was calculated. The AAV reduction rate was compared among Child-Pugh classification, modified albumin-bilirubin (mALBI) grades, FIB-4 index categories, and lesion locations using generalized estimating equations (GEE). Univariable and multivariable GEE analyses were performed to evaluate associations between the AAV reduction rate and clinical parameters. Results: Fifty-three lesions in 41 patients (median age, 76 [range, 38–88] years, 24 men) were evaluated. The AAV reduction rate was significantly lower in Child-Pugh class B than class A (p < 0.001) and in mALBI grade 2b than grade 1 (p < 0.001) or grade 2a (p = 0.004). Significant differences were also observed among FIB-4 index groups (p < 0.001) and among lesion locations, with lower AAV reduction rates in medial and anterior segments than in lateral (p < 0.001) and posterior (p = 0.017) segments. Univariable GEE analyses showed significant associations between AAV reduction rate and cholinesterase, albumin, total bilirubin (T-Bil), prothrombin time, platelet count, and FIB-4 index (p < 0.05). Multivariable GEE analysis demonstrated that both albumin and T-Bil remained independently associated with AAV reduction rate (p < 0.001). Conclusions: The AAV reduction rate tended to be lower in patients with impaired liver function and advanced liver fibrosis.
- Open Access
- 9 June 2026
- Published by MDPI AG in Tomography
- Vol. 12 (6) , 84
Adaptive Complex Signal Average Diffusion-Weighted MR Imaging of the Liver: Utility in Breath-Hold Imaging: A Retrospective Single-Center Study
Objectives: This study evaluated the utility of adaptive complex signal average (ACSA) diffusion-weighted imaging (DWI) specifically in breath-hold (BH) liver imaging, with a focus on signal intensity (SI) improvement, intrahepatic signal homogeneity, and apparent diffusion coefficient (ADC) behavior, and compared these findings with conventional non-ACSA DWI and free-breathing (FB) ACSA DWI. Methods: This retrospective study included 62 patients (mean age, 67.8 ± 13.6 years; 27 women) who underwent liver MRI with both FB and BH DWI on a 3-T system. Non-ACSA images were generated using conventional magnitude reconstruction, and ACSA images were reconstructed from identical raw data. SI, signal-to-noise ratio (SNR) and ADC were measured in the left lateral segment and right hepatic lobe. The signal intensity difference ratio (SIDR) between ACSA and non-ACSA, signal intensity ratio (SIR) and ADC ratio between right lobe and lateral segment were calculated. Results: In both FB and BH imaging, SI and SNR in both liver regions were significantly higher on ACSA DWI than on non-ACSA DWI (p < 0.01). ADC values were significantly lower with ACSA. SIDR was significantly higher in the left lateral segment (p < 0.01), indicating greater SI improvement in motion-prone regions. SIR and ADC ratios between lobes were significantly smaller with ACSA in both respiratory conditions (p < 0.01). FB-ACSA showed smaller SIR than BH-ACSA, while ADC ratios did not differ. Conclusions: ACSA DWI significantly improves SI, intrahepatic uniformity, and ADC reliability even under BH liver imaging. BH ACSA DWI may represent a potentially useful application complementary to FB ACSA DWI, supporting its consideration as a post-processing strategy for improving qualitative and quantitative liver DWI in future investigations.
- 9 June 2026
- Published by MDPI AG in Tomography
- Vol. 12 (6) , 84
Open AccessAdaptive Complex Signal Average Diffusion-Weighted MR Imaging of the Liver: Utility in Breath-Hold Imaging: A Retrospective Single-Center Study
Objectives: This study evaluated the utility of adaptive complex signal average (ACSA) diffusion-weighted imaging (DWI) specifically in breath-hold (BH) liver imaging, with a focus on signal intensity (SI) improvement, intrahepatic signal homogeneity, and apparent diffusion coefficient (ADC) behavior, and compared these findings with conventional non-ACSA DWI and free-breathing (FB) ACSA DWI. Methods: This retrospective study included 62 patients (mean age, 67.8 ± 13.6 years; 27 women) who underwent liver MRI with both FB and BH DWI on a 3-T system. Non-ACSA images were generated using conventional magnitude reconstruction, and ACSA images were reconstructed from identical raw data. SI, signal-to-noise ratio (SNR) and ADC were measured in the left lateral segment and right hepatic lobe. The signal intensity difference ratio (SIDR) between ACSA and non-ACSA, signal intensity ratio (SIR) and ADC ratio between right lobe and lateral segment were calculated. Results: In both FB and BH imaging, SI and SNR in both liver regions were significantly higher on ACSA DWI than on non-ACSA DWI (p < 0.01). ADC values were significantly lower with ACSA. SIDR was significantly higher in the left lateral segment (p < 0.01), indicating greater SI improvement in motion-prone regions. SIR and ADC ratios between lobes were significantly smaller with ACSA in both respiratory conditions (p < 0.01). FB-ACSA showed smaller SIR than BH-ACSA, while ADC ratios did not differ. Conclusions: ACSA DWI significantly improves SI, intrahepatic uniformity, and ADC reliability even under BH liver imaging. BH ACSA DWI may represent a potentially useful application complementary to FB ACSA DWI, supporting its consideration as a post-processing strategy for improving qualitative and quantitative liver DWI in future investigations.
- 24 February 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
Value of 2-point Dixon water-only Look-Locker T1 mapping on the assessment of liver fibrosis in chronic liver disease with hepatic steatosis
To evaluate the influence of fat on the assessment of liver fibrosis in chronic liver disease using two-point Dixon water-only Look-Locker T1 mapping by comparing water-only derived sequence (W-Dixon) with in-phase (IP) and opposed-phase (OP)-based sequences. 2.89-T MRI included 2D two-point Dixon Look-Locker T1 mapping and proton density fat fraction (PDFF) mapping. The correlations between liver T1 values and PDFF were assessed using Spearman correlation coefficient. T1 values on each T1 map were compared among three FIB-4 index range groups (FIB-4 < 1.3, 1.3-2.67, > 2.67) in patients with and without hepatic steatosis using one-way analysis of variance and Kruskal-Wallis test. 204 patients with chronic liver disease were retrospectively evaluated. T1 values on IP or OP images were significantly correlated with PDFF (r = -0.373, 0.220), while no significant correlation was found between T1 values on W-Dixon images and PDFF (r = -0.071). In patients without hepatic steatosis, T1 values on each T1 map in FIB-4 > 2.67 group were significantly higher than in FIB-4 1.3-2.67 group (p < 0.01). Conversely, in patients with hepatic steatosis, only W-Dixon sequence statistically differentiated FIB-4 > 2.67 group from FIB-4 1.3-2.67 group based on T1 values (p < 0.05). The assessment of liver fibrosis based on T1 values obtained by Dixon water-only T1 mapping was less influenced by the presence of fat. Two-point Dixon water-only Look-Locker T1 mapping minimizes the confounding effect of fat, enabling proper assessment of liver fibrosis in steatotic chronic liver disease.
- 24 February 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
Value of 2-point Dixon water-only Look-Locker T1 mapping on the assessment of liver fibrosis in chronic liver disease with hepatic steatosis
To evaluate the influence of fat on the assessment of liver fibrosis in chronic liver disease using two-point Dixon water-only Look-Locker T1 mapping by comparing water-only derived sequence (W-Dixon) with in-phase (IP) and opposed-phase (OP)-based sequences. 2.89-T MRI included 2D two-point Dixon Look-Locker T1 mapping and proton density fat fraction (PDFF) mapping. The correlations between liver T1 values and PDFF were assessed using Spearman correlation coefficient. T1 values on each T1 map were compared among three FIB-4 index range groups (FIB-4 < 1.3, 1.3-2.67, > 2.67) in patients with and without hepatic steatosis using one-way analysis of variance and Kruskal-Wallis test. 204 patients with chronic liver disease were retrospectively evaluated. T1 values on IP or OP images were significantly correlated with PDFF (r = -0.373, 0.220), while no significant correlation was found between T1 values on W-Dixon images and PDFF (r = -0.071). In patients without hepatic steatosis, T1 values on each T1 map in FIB-4 > 2.67 group were significantly higher than in FIB-4 1.3-2.67 group (p < 0.01). Conversely, in patients with hepatic steatosis, only W-Dixon sequence statistically differentiated FIB-4 > 2.67 group from FIB-4 1.3-2.67 group based on T1 values (p < 0.05). The assessment of liver fibrosis based on T1 values obtained by Dixon water-only T1 mapping was less influenced by the presence of fat. Two-point Dixon water-only Look-Locker T1 mapping minimizes the confounding effect of fat, enabling proper assessment of liver fibrosis in steatotic chronic liver disease.
- Open Access
- 29 September 2025
- Published by MDPI AG in Tomography
- Vol. 11 (10) , 109
Three-Dimensional Volumetric Iodine Mapping of the Liver Segment Derived from Contrast-Enhanced Dual-Energy CT for the Assessment of Hepatic Cirrhosis
Objective: This study aimed to evaluate the hepatic volume, iodine concentration, and extracellular volume (ECV) of each hepatic segment in cirrhotic patients using three-dimensional (3D) volumetric iodine mapping of the liver segment derived from contrast-enhanced dual-energy CT (DECT) superimposed on extracted color-coded CT liver segments in comparison with non-cirrhotic patients. Methods: The study population consisted of 66 patients, 34 with cirrhosis and 32 without cirrhosis. Using 3D volumetric iodine mapping of the liver segment derived from contrast-enhanced DECT superimposed on extracted color-coded CT liver segments, the volume and iodine concentration of each hepatic segment in the portal venous phase (PVP) and equilibrium phase (EP), the difference in iodine concentration between PVP and EP (ICPVP-liver—ICEP-liver), and ECV fractions were compared between cirrhotic and non-cirrhotic groups. Results: The iodine concentration was not significantly different in all hepatic segments between the cirrhotic and non-cirrhotic groups. Conversely, the difference in iodine concentration between PVP and EP (ICPVP-liver—ICEP-liver) was significantly smaller in the cirrhosis group than in the non-cirrhosis group for all hepatic segments (p < 0.001). The ECV fraction of the left medial segment was significantly higher in the cirrhosis group than in the non-cirrhotic group ([26.4 ± 7.6] vs. [23.1 ± 5.1]; p < 0.05). Conclusions: The decreased difference in iodine concentration between PVP and EP calculated from 3D volumetric iodine mapping of the liver segment using DECT may be a clinically useful indicator for evaluating patients with compensated cirrhosis, suggesting a combined effect of a reduced portal venous flow and increased interstitial space associated with fibrosis.
- 29 September 2025
- Published by MDPI AG in Tomography
- Vol. 11 (10) , 109
Open AccessThree-Dimensional Volumetric Iodine Mapping of the Liver Segment Derived from Contrast-Enhanced Dual-Energy CT for the Assessment of Hepatic Cirrhosis
Objective: This study aimed to evaluate the hepatic volume, iodine concentration, and extracellular volume (ECV) of each hepatic segment in cirrhotic patients using three-dimensional (3D) volumetric iodine mapping of the liver segment derived from contrast-enhanced dual-energy CT (DECT) superimposed on extracted color-coded CT liver segments in comparison with non-cirrhotic patients. Methods: The study population consisted of 66 patients, 34 with cirrhosis and 32 without cirrhosis. Using 3D volumetric iodine mapping of the liver segment derived from contrast-enhanced DECT superimposed on extracted color-coded CT liver segments, the volume and iodine concentration of each hepatic segment in the portal venous phase (PVP) and equilibrium phase (EP), the difference in iodine concentration between PVP and EP (ICPVP-liver—ICEP-liver), and ECV fractions were compared between cirrhotic and non-cirrhotic groups. Results: The iodine concentration was not significantly different in all hepatic segments between the cirrhotic and non-cirrhotic groups. Conversely, the difference in iodine concentration between PVP and EP (ICPVP-liver—ICEP-liver) was significantly smaller in the cirrhosis group than in the non-cirrhosis group for all hepatic segments (p < 0.001). The ECV fraction of the left medial segment was significantly higher in the cirrhosis group than in the non-cirrhotic group ([26.4 ± 7.6] vs. [23.1 ± 5.1]; p < 0.05). Conclusions: The decreased difference in iodine concentration between PVP and EP calculated from 3D volumetric iodine mapping of the liver segment using DECT may be a clinically useful indicator for evaluating patients with compensated cirrhosis, suggesting a combined effect of a reduced portal venous flow and increased interstitial space associated with fibrosis.
- Open Access
- 7 February 2025
- Published by MDPI AG in Tomography
- Vol. 11 (2) , 16
Multiparametric Magnetic Resonance Imaging Findings of the Pancreas: A Comparison in Patients with Type 1 and 2 Diabetes
Background/Objectives: Diabetes-related pancreatic changes on MRI remain unclear. Thus, we evaluated the pancreatic changes on MRI in patients with both type 1 diabetes (T1D) and type 2 diabetes (T2D) using multiparametric MRI. Methods: This prospective study involved patients with T1D or T2D who underwent upper abdominal 3-T MRI. Additionally, patients without impaired glucose metabolism were retrospectively included as a control. The imaging data included pancreatic anteroposterior (AP) diameter, pancreas-to-muscle signal intensity ratio (SIR) on fat-suppressed T1-weighted image (FS-T1WI), apparent diffusion coefficient (ADC) value, T1 value on T1 map, proton density fat fraction (PDFF), and mean secretion grade of pancreatic juice flow on cine-dynamic magnetic resonance cholangiopancreatography (MRCP). The MR measurements were compared using one-way analysis of variance and the Kruskal–Wallis test. Results: Sixty-one patients with T1D (n = 7) or T2D (n = 54) and 21 control patients were evaluated. The pancreatic AP diameters were significantly smaller in patients with T1D than in patients with T2D (p < 0.05). The average SIR on FS-T1WI was significantly lower in patients with T1D than in controls (p < 0.001). The average ADC and T1 values of the pancreas were significantly higher in patients with T1D than in patients with T2D (p < 0.01) and controls (p < 0.05). The mean secretion grade of pancreatic juice flow was significantly lower in patients with T1D than in controls (p = 0.019). The average PDFF of the pancreas was significantly higher in patients with T2D than in controls (p = 0.029). Conclusions: Patients with T1D had reduced pancreas size, increased pancreatic T1 and ADC values, and decreased pancreatic juice flow on cine-dynamic MRCP, whereas patients with T2D had increased pancreatic fat content.
- 7 February 2025
- Published by MDPI AG in Tomography
- Vol. 11 (2) , 16
Open AccessMultiparametric Magnetic Resonance Imaging Findings of the Pancreas: A Comparison in Patients with Type 1 and 2 Diabetes
Background/Objectives: Diabetes-related pancreatic changes on MRI remain unclear. Thus, we evaluated the pancreatic changes on MRI in patients with both type 1 diabetes (T1D) and type 2 diabetes (T2D) using multiparametric MRI. Methods: This prospective study involved patients with T1D or T2D who underwent upper abdominal 3-T MRI. Additionally, patients without impaired glucose metabolism were retrospectively included as a control. The imaging data included pancreatic anteroposterior (AP) diameter, pancreas-to-muscle signal intensity ratio (SIR) on fat-suppressed T1-weighted image (FS-T1WI), apparent diffusion coefficient (ADC) value, T1 value on T1 map, proton density fat fraction (PDFF), and mean secretion grade of pancreatic juice flow on cine-dynamic magnetic resonance cholangiopancreatography (MRCP). The MR measurements were compared using one-way analysis of variance and the Kruskal–Wallis test. Results: Sixty-one patients with T1D (n = 7) or T2D (n = 54) and 21 control patients were evaluated. The pancreatic AP diameters were significantly smaller in patients with T1D than in patients with T2D (p < 0.05). The average SIR on FS-T1WI was significantly lower in patients with T1D than in controls (p < 0.001). The average ADC and T1 values of the pancreas were significantly higher in patients with T1D than in patients with T2D (p < 0.01) and controls (p < 0.05). The mean secretion grade of pancreatic juice flow was significantly lower in patients with T1D than in controls (p = 0.019). The average PDFF of the pancreas was significantly higher in patients with T2D than in controls (p = 0.029). Conclusions: Patients with T1D had reduced pancreas size, increased pancreatic T1 and ADC values, and decreased pancreatic juice flow on cine-dynamic MRCP, whereas patients with T2D had increased pancreatic fat content.
- 11 December 2024
- Published by Elsevier in Radiography
- Vol. 31 (1) , 275-280
Breath-hold diffusion-weighted MR imaging (DWI) using deep learning reconstruction: Comparison with navigator triggered DWI in patients with malignant liver tumors
- 11 December 2024
- Published by Elsevier in Radiography
- Vol. 31 (1) , 275-280
Breath-hold diffusion-weighted MR imaging (DWI) using deep learning reconstruction: Comparison with navigator triggered DWI in patients with malignant liver tumors
- 13 November 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (5) , 2312-2320
Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen
Purpose To evaluate the feasibility of a high-precision single-shot fast spin–echo (SS-FSE) sequence using the deep learning-based Precise IQ Engine (PIQE) algorithm in comparison with standard SS-FSE for T2-weighted MR imaging of the abdomen, and to compare the image quality with a multi-shot (MS)-FSE sequence using the PIQE algorithm. Methods This retrospective study included 105 patients who underwent abdominal MR including T2-weighted sequences using the PIQE reconstruction algorithm. The image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in high-precision SS-FSE sequences using PIQE were compared to those in standard SS-FSE without PIQE and MS-FSE sequences using PIQE. Results The scores for all qualitative parameters were significantly higher in high-precision SS-FSE sequence using PIQE than in standard SS-FSE sequence without PIQE (all p < 0.001). In the comparison between two high-precision sequences using PIQE, the SS-FSE sequence showed significantly better scores for the blurring, ghosts or motion/flow artifacts, conspicuity of intrahepatic structures, focal nonsolid hepatic and pancreatic cystic lesions, and overall image quality, in comparison to the MS-FSE sequence (all p < 0.001). Additionally, the SS-FSE sequence using PIQE showed significantly higher SNR of the liver and CNR of nonsolid hepatic lesions than the MS-FSE sequence using PIQE (p < 0.001). Conclusions A high-precision SS-FSE sequence using the PIQE algorithm is a feasible alternative to the standard FSE sequence in T2-weighted MR imaging of the abdomen. It can improve image quality, the SNR of the liver, and the ability to visualize nonsolid focal liver lesions and pancreatic cystic lesions in comparison to a high-precision MS-FSE sequence using PIQE although this study was limited by single-center design and lack of pathological confirmation.
- 13 November 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 50 (5) , 2312-2320
Application of deep learning techniques for breath-hold, high-precision T2-weighted magnetic resonance imaging of the abdomen
Purpose To evaluate the feasibility of a high-precision single-shot fast spin–echo (SS-FSE) sequence using the deep learning-based Precise IQ Engine (PIQE) algorithm in comparison with standard SS-FSE for T2-weighted MR imaging of the abdomen, and to compare the image quality with a multi-shot (MS)-FSE sequence using the PIQE algorithm. Methods This retrospective study included 105 patients who underwent abdominal MR including T2-weighted sequences using the PIQE reconstruction algorithm. The image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in high-precision SS-FSE sequences using PIQE were compared to those in standard SS-FSE without PIQE and MS-FSE sequences using PIQE. Results The scores for all qualitative parameters were significantly higher in high-precision SS-FSE sequence using PIQE than in standard SS-FSE sequence without PIQE (all p < 0.001). In the comparison between two high-precision sequences using PIQE, the SS-FSE sequence showed significantly better scores for the blurring, ghosts or motion/flow artifacts, conspicuity of intrahepatic structures, focal nonsolid hepatic and pancreatic cystic lesions, and overall image quality, in comparison to the MS-FSE sequence (all p < 0.001). Additionally, the SS-FSE sequence using PIQE showed significantly higher SNR of the liver and CNR of nonsolid hepatic lesions than the MS-FSE sequence using PIQE (p < 0.001). Conclusions A high-precision SS-FSE sequence using the PIQE algorithm is a feasible alternative to the standard FSE sequence in T2-weighted MR imaging of the abdomen. It can improve image quality, the SNR of the liver, and the ability to visualize nonsolid focal liver lesions and pancreatic cystic lesions in comparison to a high-precision MS-FSE sequence using PIQE although this study was limited by single-center design and lack of pathological confirmation.
- Open Access
- 23 August 2023
- Published by MDPI AG in Tomography
- Vol. 9 (5) , 1568-1576
Dual-Source Contrast-Enhanced Multiphasic CT of the Liver Using Low Voltage (70 kVp): Feasibility of a Reduced Radiation Dose and a 50% of Contrast Dose
This study investigated the feasibility of both a reduced radiation dose and a 50% of contrast dose in multiphasic CT of the liver with a 70 kVp protocol compared with a standard-tube-voltage protocol derived from dual-energy (DE) CT (blended DE protocol) with a full-dose contrast-agents in the same patient group. This study included 46 patients who underwent multiphasic contrast-enhanced dynamic CT of the liver with both a 70 kVp and a blended DE protocols. For quantitative analysis, median CT values for the liver, aorta, and portal vein, as well as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured and calculated. In addition, as a qualitative analysis, the contrast effect and overall image quality of the abdominal organs were evaluated on a five-point scale. CNR and SNR of the hepatic parenchyma were not significantly different between the 70kV protocol and the Blended DE protocol in all phases. The 70 kVp protocol showed significantly better image quality compared with the blended DE protocol in the arterial phase (p = 0.035) and the equilibrium layer phase (p = 0.016). A 70 kVp CT protocol in combination with a reduced radiation dose and half-dose iodine load is feasible for multiphasic dynamic CT of the liver by maintaining the contrast enhancement effects and image quality in comparison with the blended DE CT protocol.
- 23 August 2023
- Published by MDPI AG in Tomography
- Vol. 9 (5) , 1568-1576
Open AccessDual-Source Contrast-Enhanced Multiphasic CT of the Liver Using Low Voltage (70 kVp): Feasibility of a Reduced Radiation Dose and a 50% of Contrast Dose
This study investigated the feasibility of both a reduced radiation dose and a 50% of contrast dose in multiphasic CT of the liver with a 70 kVp protocol compared with a standard-tube-voltage protocol derived from dual-energy (DE) CT (blended DE protocol) with a full-dose contrast-agents in the same patient group. This study included 46 patients who underwent multiphasic contrast-enhanced dynamic CT of the liver with both a 70 kVp and a blended DE protocols. For quantitative analysis, median CT values for the liver, aorta, and portal vein, as well as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), were measured and calculated. In addition, as a qualitative analysis, the contrast effect and overall image quality of the abdominal organs were evaluated on a five-point scale. CNR and SNR of the hepatic parenchyma were not significantly different between the 70kV protocol and the Blended DE protocol in all phases. The 70 kVp protocol showed significantly better image quality compared with the blended DE protocol in the arterial phase (p = 0.035) and the equilibrium layer phase (p = 0.016). A 70 kVp CT protocol in combination with a reduced radiation dose and half-dose iodine load is feasible for multiphasic dynamic CT of the liver by maintaining the contrast enhancement effects and image quality in comparison with the blended DE CT protocol.
- 8 August 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (10) , 6844-6851
Impact of fat on the apparent T1 value of the liver: assessment by water-only derived T1 mapping
Objectives To determine the impact of fat on the apparent T1 value of the liver using water-only derived T1 mapping. Methods 3-T MRI included 2D Look-Locker T1 mapping and proton density fat fraction (PDFF) mapping. T1 values of the liver were compared among T1 maps obtained by in-phase (IP), opposed-phase (OP), and Dixon water sequences using paired t-test. The correlation between T1 values of the liver on each T1 map and PDFF was assessed using Spearman correlation coefficient. The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were also correlated with PDFF. Results One hundred sixty-two patients (median age, 70 [range, 24–91] years, 90 men) were retrospectively evaluated. The T1 values of the liver on each T1 map were significantly different (p < 0.001). The T1 value of the liver on IP images was significantly negatively correlated with PDFF (r = − 0.438), while the T1 value of the liver on OP images was slightly positively correlated with PDFF (r = 0.164). The T1 value of the liver on Dixon water images was slightly negatively correlated with PDFF (r = − 0.171). The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were significantly correlated with PDFF (r = 0.606, 0.722; p < 0.001). Conclusion Fat correction for the apparent T1 value by water-only derived T1 maps will be helpful for accurately evaluating the T1 value of the liver. Clinical relevance statement Fat-corrected T1 mapping of the liver with the water component only obtained from the 2D Dixon Look-Locker sequence could be useful for accurately evaluating the T1 value of the liver without the impact of fat in daily clinical practice. Key Points • The T1 values of the liver on the conventional T1 maps are significantly affected by the presence of fat. • The apparent T1 value of the liver on water-only derived T1 maps would be slightly impacted by the presence of fat. • Fat correction for the apparent T1 values is necessary for the accurate assessment of the T1 values of the liver.
- 8 August 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (10) , 6844-6851
Impact of fat on the apparent T1 value of the liver: assessment by water-only derived T1 mapping
Objectives To determine the impact of fat on the apparent T1 value of the liver using water-only derived T1 mapping. Methods 3-T MRI included 2D Look-Locker T1 mapping and proton density fat fraction (PDFF) mapping. T1 values of the liver were compared among T1 maps obtained by in-phase (IP), opposed-phase (OP), and Dixon water sequences using paired t-test. The correlation between T1 values of the liver on each T1 map and PDFF was assessed using Spearman correlation coefficient. The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were also correlated with PDFF. Results One hundred sixty-two patients (median age, 70 [range, 24–91] years, 90 men) were retrospectively evaluated. The T1 values of the liver on each T1 map were significantly different (p < 0.001). The T1 value of the liver on IP images was significantly negatively correlated with PDFF (r = − 0.438), while the T1 value of the liver on OP images was slightly positively correlated with PDFF (r = 0.164). The T1 value of the liver on Dixon water images was slightly negatively correlated with PDFF (r = − 0.171). The absolute differences between T1 value of the liver on Dixon water images and that on IP or OP images were significantly correlated with PDFF (r = 0.606, 0.722; p < 0.001). Conclusion Fat correction for the apparent T1 value by water-only derived T1 maps will be helpful for accurately evaluating the T1 value of the liver. Clinical relevance statement Fat-corrected T1 mapping of the liver with the water component only obtained from the 2D Dixon Look-Locker sequence could be useful for accurately evaluating the T1 value of the liver without the impact of fat in daily clinical practice. Key Points • The T1 values of the liver on the conventional T1 maps are significantly affected by the presence of fat. • The apparent T1 value of the liver on water-only derived T1 maps would be slightly impacted by the presence of fat. • Fat correction for the apparent T1 values is necessary for the accurate assessment of the T1 values of the liver.
- 1 June 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1146) , 20220937
Automated whole-volume measurement of CT fat fraction of the pancreas: correlation with Dixon MR imaging
Objectives: This study aimed to assess the feasibility of pancreatic steatosis quantification by automated whole-volume measurement of the fat fraction of the pancreas on CT in comparison to MRI using proton-density fat fraction (PDFF) techniques. Methods: Fifty-nine patients who underwent both CT and MRI were analyzed. Automated whole-volume measurement of pancreatic fat on unenhanced CT was performed by a histogram analysis with local thresholding. Three sets of CT fat volume fraction (FVF) (%) values with thresholds of −30 Hounsfield unit (HU), −20 HU and −10 HU were compared to MR-FVF (%) values measured on a PDFF map. Results: The median −30 HU CT-FVF, −20 HU CT-FVF, −10 HU CT-FVF and MR-FVF values of the pancreas were 8.6% (interquartile range (IQR), 11.3), 10.5% (IQR, 13.2), 13.4% (IQR, 16.1) and 10.9% (IQR, 9.7), respectively. The −30 HU CT-FVF (%), −20 HU CT-FVF (%) and −10 HU CT-FVF (%) of the pancreas showed a significant positive correlation with the MR-FVF (%) of the pancreas (ρ = 0.898, p < 0.001, ρ = 0.905, p < 0.001, ρ = 0.909, p < 0.001, respectively). The −20 HU CT-FVF (%) displayed reasonable agreement with the MR-FVF (%) with a low absolute fixed bias (mean difference, 0.32%; limit of agreement from −10.1 to 10.7%). Conclusion: The automated whole-volume measurement of the CT fat fraction of the pancreas using the threshold CT attenuation value of −20 HU may be a feasible, non-invasive, and convenient technique for quantifying pancreatic steatosis. Advances in knowledge: CT-FVF value of the pancreas had a positive correlation with the MR-FVF value. The −20 HU CT-FVF may be a convenient technique for quantifying pancreatic steatosis.
- 1 June 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1146) , 20220937
Automated whole-volume measurement of CT fat fraction of the pancreas: correlation with Dixon MR imaging
Objectives: This study aimed to assess the feasibility of pancreatic steatosis quantification by automated whole-volume measurement of the fat fraction of the pancreas on CT in comparison to MRI using proton-density fat fraction (PDFF) techniques. Methods: Fifty-nine patients who underwent both CT and MRI were analyzed. Automated whole-volume measurement of pancreatic fat on unenhanced CT was performed by a histogram analysis with local thresholding. Three sets of CT fat volume fraction (FVF) (%) values with thresholds of −30 Hounsfield unit (HU), −20 HU and −10 HU were compared to MR-FVF (%) values measured on a PDFF map. Results: The median −30 HU CT-FVF, −20 HU CT-FVF, −10 HU CT-FVF and MR-FVF values of the pancreas were 8.6% (interquartile range (IQR), 11.3), 10.5% (IQR, 13.2), 13.4% (IQR, 16.1) and 10.9% (IQR, 9.7), respectively. The −30 HU CT-FVF (%), −20 HU CT-FVF (%) and −10 HU CT-FVF (%) of the pancreas showed a significant positive correlation with the MR-FVF (%) of the pancreas (ρ = 0.898, p < 0.001, ρ = 0.905, p < 0.001, ρ = 0.909, p < 0.001, respectively). The −20 HU CT-FVF (%) displayed reasonable agreement with the MR-FVF (%) with a low absolute fixed bias (mean difference, 0.32%; limit of agreement from −10.1 to 10.7%). Conclusion: The automated whole-volume measurement of the CT fat fraction of the pancreas using the threshold CT attenuation value of −20 HU may be a feasible, non-invasive, and convenient technique for quantifying pancreatic steatosis. Advances in knowledge: CT-FVF value of the pancreas had a positive correlation with the MR-FVF value. The −20 HU CT-FVF may be a convenient technique for quantifying pancreatic steatosis.