Ae Shin Cho
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ae Shin Cho has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Byeong-Cheol Kang
Seoul National University Hospital Marmoset Model Resource Bank (SNUH-MMRB), Seoul, the Republic of Korea; Department of Experiment Animal Research, Biomedical Research Institute, Seoul National University Hospital, Seoul, the Republic of Korea; Graduate School of Translational Medicine, Seoul National University College of Medicine, Seoul, the Republic of Korea
1 shared publication- Dongjun Koo
Interdisciplinary Program in Bioengineering, Seoul National University, Seoul, the Republic of Korea; Office of eHealth Research and Business, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, the Republic of Korea
1 shared publication - Hak Jong Lee
Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
1 shared publication - Ho-Young Lee
Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam, Korea
1 shared publication Hyun-Sun Lee
Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, the Republic of Korea
1 shared publicationJae Sung Lee
Interdisciplinary Program in Bioengineering, Seoul National University, Seoul, the Republic of Korea; Department of Nuclear Medicine, Seoul National University College of Medicine, the Republic of Korea
1 shared publication
Latest Publications
- 4 May 2026
- Published by Elsevier in Neuroscience
- Vol. 610, 14-21
Metabolic neural networks of the marmoset brain in awake and isoflurane-anesthetized resting states
- 4 May 2026
- Published by Elsevier in Neuroscience
- Vol. 610, 14-21
Metabolic neural networks of the marmoset brain in awake and isoflurane-anesthetized resting states
- Open Access
- 1 January 2020
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 39 (1) , 60-69
Evaluation of lymph node metastasis in a rabbit tumor model: correlations between contrast-enhanced ultrasound and pathologic findings
The purpose of this study was to evaluate the ability of contrast-enhanced ultrasonography (CEUS) with microbubbles to detect metastatic lymph nodes (LNs) for treatment planning and prognosis. For the metastatic LN model, ground VX2 tumor tissues were injected subcutaneously in 12 rabbits, just below the right hind limb. The rabbits were classified into three groups based on the LN area: group A (n=4, >1.9 cm2 ), group B (n=4, 1-1.9 cm2 ), and group C (n=4, <1 cm2 ). The LNs were monitored on CEUS for 10 seconds after injecting 2.5 mL of microbubbles. The percent area of metastatic LNs was calculated on pathologic images and compared with CEUS images. In group A, the mean percent area of metastasis was 40.7%±19.4%. In all cases of metastasis, round-shaped perfusion defects were clearly observed in CEUS images. The metastatic areas were strongly correlated with pathologic findings. The mean percent area in group B was 21.5%±14.4%. The CEUS findings showed multiple nodular perfusion defects, clearly revealing the metastatic areas. In group B, the CEUS and pathologic findings were concordant for three of the four cases. The mean percent area in group C was 9.1%±6.4%. However, in this group, CEUS only detected a small perfusion defect in one case. CEUS has the potential to depict characteristic imaging features of metastatic LNs but still has limitations in early detection.
- 1 January 2020
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 39 (1) , 60-69
Open AccessEvaluation of lymph node metastasis in a rabbit tumor model: correlations between contrast-enhanced ultrasound and pathologic findings
The purpose of this study was to evaluate the ability of contrast-enhanced ultrasonography (CEUS) with microbubbles to detect metastatic lymph nodes (LNs) for treatment planning and prognosis. For the metastatic LN model, ground VX2 tumor tissues were injected subcutaneously in 12 rabbits, just below the right hind limb. The rabbits were classified into three groups based on the LN area: group A (n=4, >1.9 cm2 ), group B (n=4, 1-1.9 cm2 ), and group C (n=4, <1 cm2 ). The LNs were monitored on CEUS for 10 seconds after injecting 2.5 mL of microbubbles. The percent area of metastatic LNs was calculated on pathologic images and compared with CEUS images. In group A, the mean percent area of metastasis was 40.7%±19.4%. In all cases of metastasis, round-shaped perfusion defects were clearly observed in CEUS images. The metastatic areas were strongly correlated with pathologic findings. The mean percent area in group B was 21.5%±14.4%. The CEUS findings showed multiple nodular perfusion defects, clearly revealing the metastatic areas. In group B, the CEUS and pathologic findings were concordant for three of the four cases. The mean percent area in group C was 9.1%±6.4%. However, in this group, CEUS only detected a small perfusion defect in one case. CEUS has the potential to depict characteristic imaging features of metastatic LNs but still has limitations in early detection.