    Strain-Engineered PVA Hydrogels for Anisotropic Load-Bearing Fibrocartilage: Mechanical and Microstructural Characterization in a Meniscal Model

    by Joshua Winograd, Michael Greenberg, Autumn Kim, Cara Moore, Roanne Yehia, Clarisse Zigan, Suzanne Maher, Tony Chen

    Poly(vinyl alcohol) (PVA) hydrogels are promising for meniscal replacement, but reproducing native meniscal anisotropy remains unsolved. We developed a fabrication strategy for imparting controlled anisotropy to PVA hydrogels. We hypothesized that modulus and alignment would increase with applied strain, and that circumferential strain would produce direction-dependence in a meniscal-like geometry. Dogbone specimens at three PVA concentrations were strained 0–200% during freeze–thaw processing. Meniscal-like specimens were fabricated at 27.5% PVA under 200% circumferential strain. Constructs were characterized by tensile testing, stress-relaxation compression, and polarized light microscopy. In dogbone specimens, tensile modulus rose exponentially and coherency linearly with applied strain (adjusted R² > 0.92; R² ≥ 0.96). In meniscal-like specimens, stretching increased circumferential peak stress (587 ± 173 vs 439 ± 96 kPa), and direction-dependence appeared only after stretching. Stretched constructs showed higher optical coherency (p = 0.002, r = 0.77), concentrated in the outer third of the cross-section. Compressive moduli trended lower in stretched constructs, reaching significance anteriorly. Strain applied during freeze–thaw processing programs direction-dependent stiffness and alignment into a homogeneous hydrogel, though absolute stiffness remains below native tissue. More strain during processing is the most direct route to a stiffer construct, and further development is required before functional replacement.

  • A novel knee joint laxity measurement device in mice

    by Paula M.P. Trinh, Camila B. Carballo, Lauren Simonian, Scott A. Rodeo, Tony Chen

  • Open Access

    Meniscal Dominant Loaders During Simulated Gait: A Cadaveric Study in Human Knees

    by Tony Chen, Kalle Chastain, Megh Prajapati, Sarah Segal, Michael K. Parides, Russell F. Warren, Suzanne A. Maher

    Background: Changes in joint contact force distribution after injury are 1 factor driving tissue degeneration. Although clinical interventions aim to restore forces to their uninjured state, inconsistent outcomes suggest that patient variability in joint contact mechanics remains poorly understood, despite the use of patient-specific computational models that are too labor-intensive to be widely adopted. A more practical solution may involve grouping knees by commonalities in force distribution, enabling recognition of heterogeneity without requiring fully individualized models. Hypothesis/Purpose: The objective of this study was to determine whether human cadaveric knees can be grouped based on differences in joint contact force distribution across the tibial plateau during the stance phase of simulated gait. We hypothesized that a subset of knees would heavily rely on the meniscus (“meniscal-dominant loaders”) and another subset of knees would distribute more force through cartilage-to-cartilage contact (“cartilage-dominant loaders”). Our secondary hypothesis was that cartilage-dominant loaders would have their peak contact stress in the cartilage-cartilage contact region, and those with meniscal-dominant loading would have peak contact stress primarily located in the meniscus footprint. Study Design: Descriptive laboratory study. Methods: Cartilage-cartilage and meniscal footprints were identified on contact force data across the tibial plateaus of cadaveric knees (n = 44) subjected to simulated gait. Knees were grouped based on force distribution on the medial or lateral plateaus using K-means clustering. They were characterized as meniscal dominant loaders if >50% of the compartment load was acting through the meniscus for >50% of the simulated gait cycle. Knees were characterized as cartilage-dominant loaders if >50% of the compartment load was acting through the cartilage-to-cartilage contact zone for most of the gait cycle. Results: On the medial plateau, 4 clusters were identified. These clusters ranged from cartilage-dominant loaders (Cluster 1 [7% of knees]) to meniscal loaders (Cluster 4 [48% of knees]). Knees in Cluster 2 (20% of knees) and 3 (25% of knees) were meniscal-dominant loaders in early stance and switched to cartilage-dominant loading in late stance. The peak contact stress shifted from the cartilage-cartilage region in cartilage-dominant loaders to the meniscus footprint in meniscal-dominant loaders. On the lateral plateau, 3 clusters were identified. These clusters again ranged from cartilage-dominant loaders (Cluster 1 [11% of knees]) to meniscal-dominant loaders (Cluster 3 [72% of knees]). Knees in Cluster 2 (17% of knees) equally shared load between the cartilage and meniscus. No differences were found in peak stress between cartilage-dominant loaders and meniscal-dominant loaders on the lateral plateau. Conclusion: We confirmed that human cadaveric knees can be stratified based on the distribution of load through menisci and that peak pressures were higher in the cartilage-dominant loading knees. Clinical Relevance: This study identifies heterogeneity in how human cadaveric knees distribute forces during simulated gait. This information is fundamental to understanding and improving upon the biomechanical variability in the knee's response to injury and repair.

  • Tekscan analysis programs (TAP) for quantifying dynamic contact mechanics

    by Tony Chen, Ashley Pekmezian, Erin R Leatherman, Thomas J Santner, Suzanne A Maher


  • 1291 - A Novel Bioreactor for Quantifying Chondrocyte Response to Physiological Loads: Effect of Boundary Conditions on Cell Response

    by Tony Chen

    INTRODUCTION: Models aimed at characterizing the response of chondrocytes to mechanical forces are designed as displacement-controlled systems th |

  • The Scaffold–Articular Cartilage Interface: A Combined In Vitro and In Silico Analysis Under Controlled Loading Conditions

    by Tony Chen, Moira M. McCarthy, Hongqiang Guo, Russell Warren, Suzanne A. Maher

    The optimal method to integrate scaffolds with articular cartilage has not yet been identified, in part because of our lack of understanding about the mechanobiological conditions at the interface. Our objective was to quantify the effect of mechanical loading on integration between a scaffold and articular cartilage. We hypothesized that increased number of loading cycles would have a detrimental effect on interface integrity. The following models were developed: (i) an in vitro scaffold–cartilage explant system in which compressive sinusoidal loading cycles were applied for 14 days at 1 Hz, 5 days per week, for either 900, 1800, 3600, or 7200 cycles per day and (ii) an in silico inhomogeneous, biphasic finite element model (bFEM) of the scaffold–cartilage construct that was used to characterize interface micromotion, stress, and fluid flow under the prescribed loading conditions. In accordance with our hypothesis, mechanical loading significantly decreased scaffold–cartilage interface strength compared to unloaded controls regardless of the number of loading cycles. The decrease in interfacial strength can be attributed to abrupt changes in vertical displacement, fluid pressure, and compressive stresses along the interface, which reach steady-state after only 150 cycles of loading. The interfacial mechanical conditions are further complicated by the mismatch between the homogeneous properties of the scaffold and the depth-dependent properties of the articular cartilage. Finally, we suggest that mechanical conditions at the interface can be more readily modulated by increasing pre-incubation time before the load is applied, as opposed to varying the number of loading cycles.


  • Open Access

    PD18-11 COMPARISON OF AN ELECTRIC PULSE LITHOTRIPTER TO THE HOLMIUM LASER: STONE FRAGMENTATION EFFICIENCY AND IMPACT ON FLEXIBLE URETEROSCOPE DEFLECTION AND FLOW

    by Adam Kaplan, Tony Chen, Richard Shin, Joanne Dale, Fernando Cabrera, Daniela Radvak, Anika Ackerman, Georgy Sankin, Pei Zhong, Jr. Charles Scales, et al.


  • Open Access

    Differential cross-linking and radio-protective effects of genipin on mature bovine and human patella tendons

    by Kenneth W. Ng, Florian Wanivenhaus, Tony Chen, Valarian D. Abrams, Peter A. Torzilli, Russell F. Warren, Suzanne A. Maher

    Gamma irradiation is a proven sterilization method, but is not widely used on allografts for anterior cruciate ligament reconstruction (e.g., patella tendon) due to radiation-induced decreases in mechanical strength. Addressing this drawback would improve the safety and supply of allografts to meet current and future demand. It was hypothesized that genipin-induced collagen cross-linking would increase the tensile modulus of patella tendon tissue such that 5 MRad gamma irradiation would not reduce the tissue mechanical strength below the original untreated values. Optimized genipin treatment increased the tensile modulus of bovine tendons by ~2.4-fold. After irradiation, genipin treated tissue did not significantly differ from native tissue, proving the hypothesis. Optimized genipin treatment of human tendons increased the tensile modulus by ~1.3-fold. After irradiation, both control and genipin-treated tissues possessed ~50–60% of their native tendon modulus, disproving the hypothesis. These results highlight possible age- and species- dependent effects of genipin cross-linking on tendon tissue. Cross-linking of human allografts may be beneficial only in younger donor tissues. Future research is warranted to better understand the mechanisms and applications of collagen cross-linking for clinical use.