Robert G. Hauser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert G. Hauser has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Jay D. Sengupta
The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, MN
10 shared publicationsDawn Witt
The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, MN
9 shared publicationsJay Sengupta
The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation Minneapolis Minnesota USA
6 shared publicationsLarissa I. Stanberry
6 shared publicationsMelanie Kapphahn-Bergs
The Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, MN
6 shared publicationsSusan A. Casey
Joseph F. Novogratz Family Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota
6 shared publications
Latest Publications
- 31 July 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (11) , e2706-e2707
Disproportionate view of pulsed field ablation safety signals
- 31 July 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (11) , e2706-e2707
Disproportionate view of pulsed field ablation safety signals
- 26 February 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (9) , 1992-1999
Rapid early battery depletion and lead–electrode corrosion owing to CIED gate oxide semiconductor defects
- 26 February 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (9) , 1992-1999
Rapid early battery depletion and lead–electrode corrosion owing to CIED gate oxide semiconductor defects
- Open Access
- 13 November 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (2) , 293-298
Inappropriate shocks from subcutaneous and transvenous implantable cardioverter-defibrillators: Reports from the FDA MAUDE database
- 13 November 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (2) , 293-298
Open AccessInappropriate shocks from subcutaneous and transvenous implantable cardioverter-defibrillators: Reports from the FDA MAUDE database
- Open Access
Novel Ripple Frequency–Guided Substrate Targeting for Persistent Atrial Fibrillation: 12-Month Outcomes
Background: Outcomes after pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) remain limited, motivating patient-specific strategies to identify non-PV sources. Ripple Frequency is an automated mapping algorithm designed to localize AF sources for targeted ablation by highlighting regions with high frequency directional changes in electrogram dV/dT. Objective: To evaluate 12-month freedom from AF and any atrial arrhythmia following non-PV Ripple Frequency–guided ablation for persistent AF. Methods: We analyzed 72 patients undergoing first-time ablation for persistent AF. After PVI, ablation was directed at non-PV atrial regions in the top quartile of each patient’s Ripple Frequency maps. The primary endpoint was first AF recurrence >30 s after a 90-day blanking period on or off antiarrhythmic drugs (AADs); secondary endpoints included atrial tachycardia/flutter (AT/AFL), any atrial arrhythmia, and safety. Freedom from AF at 12 months was compared with that observed in the PVI arm of the STAR-AF II trial for additional context. Results: Ripple Frequency targets were ablated in 66/72 patients (92%), yielding acute AF termination in 64/72 patients (88.9%). Single procedure 12-month freedom from AF was 95.8% (95% CI 87.6-98.6) on/off AAD, and freedom from any atrial arrhythmia was 72.2% (95% CI 60.3-81.1). After 1.2 procedures, these rose to 97.2% and 90.3%. Compared with the STAR-AF II PVI arm (60%), 12-month AF freedom was 35.8% (95% CI 22.3-40.0%) higher. Conclusion: In this single-center cohort, non-PV ablation guided by Ripple Frequency was associated with a high 12-month AF and any arrhythmia freedom with no major complications. Central Illustration:
Open AccessNovel Ripple Frequency–Guided Substrate Targeting for Persistent Atrial Fibrillation: 12-Month Outcomes
Background: Outcomes after pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) remain limited, motivating patient-specific strategies to identify non-PV sources. Ripple Frequency is an automated mapping algorithm designed to localize AF sources for targeted ablation by highlighting regions with high frequency directional changes in electrogram dV/dT. Objective: To evaluate 12-month freedom from AF and any atrial arrhythmia following non-PV Ripple Frequency–guided ablation for persistent AF. Methods: We analyzed 72 patients undergoing first-time ablation for persistent AF. After PVI, ablation was directed at non-PV atrial regions in the top quartile of each patient’s Ripple Frequency maps. The primary endpoint was first AF recurrence >30 s after a 90-day blanking period on or off antiarrhythmic drugs (AADs); secondary endpoints included atrial tachycardia/flutter (AT/AFL), any atrial arrhythmia, and safety. Freedom from AF at 12 months was compared with that observed in the PVI arm of the STAR-AF II trial for additional context. Results: Ripple Frequency targets were ablated in 66/72 patients (92%), yielding acute AF termination in 64/72 patients (88.9%). Single procedure 12-month freedom from AF was 95.8% (95% CI 87.6-98.6) on/off AAD, and freedom from any atrial arrhythmia was 72.2% (95% CI 60.3-81.1). After 1.2 procedures, these rose to 97.2% and 90.3%. Compared with the STAR-AF II PVI arm (60%), 12-month AF freedom was 35.8% (95% CI 22.3-40.0%) higher. Conclusion: In this single-center cohort, non-PV ablation guided by Ripple Frequency was associated with a high 12-month AF and any arrhythmia freedom with no major complications. Central Illustration:
- Open Access
- 25 June 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (8) , 1053-1059
Safety of a pacemaker mode intended to protect patients
- 25 June 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (8) , 1053-1059
Open AccessSafety of a pacemaker mode intended to protect patients
- Open Access
- 8 April 2025
- Published by Elsevier in Heart Rhythm
- Vol. 22 (10) , 2724-2725
A delayed pacemaker recall
- 8 April 2025
- Published by Elsevier in Heart Rhythm
- Vol. 22 (10) , 2724-2725
Open AccessA delayed pacemaker recall
- 30 October 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (12) , 2483-2486
Device dislodgement and embolization associated with a new leadless pacemaker
Introduction: Currently, there are two approved single chamber leadless pacemakers (LP) in the United States (US), Micra VR™; approved since 2016 and AVEIR VR™; approved in 2022. A potential complication of LPs is dislodgement and/or embolization (D/E) during or after implant. According to the IDE trials, there appears to be a significant difference in D/E rates between the two LPs that have different fixation mechanisms; Micra uses nitinol tines, while AVEIR uses an active screw helix. The aim of this study was to determine if the AVEIR VR LP has continued to exhibit D/E in the United States since it was approved by the Food and Drug Administration (FDA) in April 2022.Methods: The FDA Manufacturer and User Facility Device Experience (MAUDE) database was searched for US D/E reports communicated by the manufacturers of both LP devices. For AVEIR VR we reviewed reports from approval till December 2023, and for Micra VR we looked at reports from approval to April 2024. Excluded were reports based on information indirectly obtained from registries, journals, social media, or volunteers. Total number of US implants was acquired from the manufacturers' product performance reports.Results: During a period of 21 months, 5990 AVEIR VR implants had been registered in the United States, of which 53 (0.88%) encountered D/E both during and after the procedure. More D/E (32; 60.4%) occurred during the implantation procedure, with device release problems being the most prominent procedural issue involved with these events. Within a 8‐year period, 72 237 Micra VR implants have been registered in the United States, of which 211 (0.29%) showed D/E. The rate of D/E since the US approval of both devices was significantly higher for AVEIR VR compared to Micra VR (0.88% vs 0.29%; p < .0001).Conclusion: AVEIR VR implants may be complicated by dislodgement with or without embolization. Currently, the estimated incidence is about 0.9%, which is significantly higher than Micra VR. Fixation issues and separation problems of the device from the delivery catheter appear to be responsible for most of these D/E events.
- 30 October 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (12) , 2483-2486
Device dislodgement and embolization associated with a new leadless pacemaker
Introduction: Currently, there are two approved single chamber leadless pacemakers (LP) in the United States (US), Micra VR™; approved since 2016 and AVEIR VR™; approved in 2022. A potential complication of LPs is dislodgement and/or embolization (D/E) during or after implant. According to the IDE trials, there appears to be a significant difference in D/E rates between the two LPs that have different fixation mechanisms; Micra uses nitinol tines, while AVEIR uses an active screw helix. The aim of this study was to determine if the AVEIR VR LP has continued to exhibit D/E in the United States since it was approved by the Food and Drug Administration (FDA) in April 2022.Methods: The FDA Manufacturer and User Facility Device Experience (MAUDE) database was searched for US D/E reports communicated by the manufacturers of both LP devices. For AVEIR VR we reviewed reports from approval till December 2023, and for Micra VR we looked at reports from approval to April 2024. Excluded were reports based on information indirectly obtained from registries, journals, social media, or volunteers. Total number of US implants was acquired from the manufacturers' product performance reports.Results: During a period of 21 months, 5990 AVEIR VR implants had been registered in the United States, of which 53 (0.88%) encountered D/E both during and after the procedure. More D/E (32; 60.4%) occurred during the implantation procedure, with device release problems being the most prominent procedural issue involved with these events. Within a 8‐year period, 72 237 Micra VR implants have been registered in the United States, of which 211 (0.29%) showed D/E. The rate of D/E since the US approval of both devices was significantly higher for AVEIR VR compared to Micra VR (0.88% vs 0.29%; p < .0001).Conclusion: AVEIR VR implants may be complicated by dislodgement with or without embolization. Currently, the estimated incidence is about 0.9%, which is significantly higher than Micra VR. Fixation issues and separation problems of the device from the delivery catheter appear to be responsible for most of these D/E events.
- Retracted
- 13 October 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (12) , 2397-2401
RETRACTED: A comparison of procedure‐related adverse events between two right ventricular leadless pacemakers
Introduction: The Medtronic Micra VR and Abbott AVEIR VR are the leadless pacemakers (LPM) currently available in the United States (US). Micra VR employs fixation tines and the AVEIR VR uses an active fixation helix. Micra VR requires fixation before electrical measurements are obtained, while R‐waves may be mapped by AVEIR VR without fixation. Little comparative data is available for these LPMs. Accordingly, we compared the incidences of procedure‐related major adverse clinical events (MACE) and device problems in the US for Micra VR and AVEIR VR during 2022–2024.Methods: We searched the FDA's Manufacturer and User Facility Device Experience (MAUDE) database for US reports of MACE and device problems that were filed from April 2022 to December 2023 for AVEIR VR, and from June 2022 to April 2024 for Micra VR. Totals for US‐registered LPM implants were obtained from the manufacturers' product performance reports.Results: During the study period, 5990 AVEIR VR and 10 940 Micra VR implants were registered in the US. We found 305 MAUDE reports for AVEIR VR (5.1%), versus 541 MAUDE reports for Micra VR (4.9%) (p = .702). The incidence of MACE was 0.72% (43/5990) for AVEIR VR versus 0.59% (65/10 940) for Micra VR, (p = .387). The incidences of procedure‐related death, cardiac perforation. cardiac arrest, emergency pericardial drainage or reparative surgery were similar for both LPMs (p > .05). Micra VR had more unacceptable thresholds requiring LPM replacement compared to AVEIR VR (95;0.9% vs. 24;0.4%; p = .001). AVEIR VR had a statistically higher incidence of device dislodgement during (32) and after (21) implant compared to Micra VR (53 (0.9%) vs. 46 (0.4%), p < .001).Conclusions: Micra VR and AVEIR VR have similar procedural safety profiles, including the incidences of death and perforation. However, device problems differed significantly, possibly related to their design differences. Compared to Micra VR, AVEIR VR appears to have an advantageous threshold measurement capability but is more prone to device dislodgement.
- 13 October 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (12) , 2397-2401
RetractedRETRACTED: A comparison of procedure‐related adverse events between two right ventricular leadless pacemakers
Introduction: The Medtronic Micra VR and Abbott AVEIR VR are the leadless pacemakers (LPM) currently available in the United States (US). Micra VR employs fixation tines and the AVEIR VR uses an active fixation helix. Micra VR requires fixation before electrical measurements are obtained, while R‐waves may be mapped by AVEIR VR without fixation. Little comparative data is available for these LPMs. Accordingly, we compared the incidences of procedure‐related major adverse clinical events (MACE) and device problems in the US for Micra VR and AVEIR VR during 2022–2024.Methods: We searched the FDA's Manufacturer and User Facility Device Experience (MAUDE) database for US reports of MACE and device problems that were filed from April 2022 to December 2023 for AVEIR VR, and from June 2022 to April 2024 for Micra VR. Totals for US‐registered LPM implants were obtained from the manufacturers' product performance reports.Results: During the study period, 5990 AVEIR VR and 10 940 Micra VR implants were registered in the US. We found 305 MAUDE reports for AVEIR VR (5.1%), versus 541 MAUDE reports for Micra VR (4.9%) (p = .702). The incidence of MACE was 0.72% (43/5990) for AVEIR VR versus 0.59% (65/10 940) for Micra VR, (p = .387). The incidences of procedure‐related death, cardiac perforation. cardiac arrest, emergency pericardial drainage or reparative surgery were similar for both LPMs (p > .05). Micra VR had more unacceptable thresholds requiring LPM replacement compared to AVEIR VR (95;0.9% vs. 24;0.4%; p = .001). AVEIR VR had a statistically higher incidence of device dislodgement during (32) and after (21) implant compared to Micra VR (53 (0.9%) vs. 46 (0.4%), p < .001).Conclusions: Micra VR and AVEIR VR have similar procedural safety profiles, including the incidences of death and perforation. However, device problems differed significantly, possibly related to their design differences. Compared to Micra VR, AVEIR VR appears to have an advantageous threshold measurement capability but is more prone to device dislodgement.
- Open Access
- 6 September 2024
- Published by Elsevier in JACC: Advances
- Vol. 3 (10) , 101263
Repolarization Injury and Occurrence of Torsades de Pointes During Acute Takotsubo Syndrome
- 6 September 2024
- Published by Elsevier in JACC: Advances
- Vol. 3 (10) , 101263
Open AccessRepolarization Injury and Occurrence of Torsades de Pointes During Acute Takotsubo Syndrome
- 29 August 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (5) , 1249-1254
Failure to treat ventricular tachycardia or ventricular fibrillation by implantable cardioverter-defibrillators
- 29 August 2024
- Published by Elsevier in Heart Rhythm
- Vol. 22 (5) , 1249-1254
Failure to treat ventricular tachycardia or ventricular fibrillation by implantable cardioverter-defibrillators