Xuegao Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuegao Yu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Jiankai Deng
Department of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University , Guangzhou , China
2 shared publications- Xuegao Yu
Department of laboratory medicine, The first Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
2 shared publications Yaoming Chen
Department of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University , Guangzhou , China
2 shared publications- Laisheng Li
Department of Laboratory Medicine The First Affiliated Hospital of Sun Yat‐sen University Guangzhou China
1 shared publication Min Liu
Department of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University , Guangzhou , China
1 shared publicationQinghua Ma
Department of Laboratory Medicine, The First Affiliated Hospital, Sun Yat-sen University , Guangzhou , China
1 shared publication
Latest Publications
- 17 June 2022
- Published by Oxford University Press (OUP) in Laboratory Medicine
- Vol. 54 (1) , e10-e13
Application of the Fluorescence Method on Sysmex XN9000 Hematology Analyzer for Correcting Platelet Count in Individuals with Microcytosis
Objective: Although small red blood cells are a well-known analytical pitfall that could cause artifactual increase of the platelet count, limited information is available on the accuracy of impedance platelet counting in cases with microcytosis. The aim of this study is to assess the accuracy of impedance platelet counting in the presence of small red blood cells, and to establish the optimal mean corpuscular volume (MCV) cutoff to endorse fluorescence platelet counting.Methods: In this study, platelet counts estimated by the impedance method on the Sysmex XN9000 analyzer (Sysmex, Kobe, Japan) were compared with those provided by the fluorescence method. The accuracy of impedance platelet counting was assessed. Receiver operating characteristic curve was used to evaluate the performance of MCV in predicting falsely increased platelet counts.Results: There was a tendency for the impedance method to overestimate the platelet count in samples with 70 fL < MCV ≤ 80 fL, 60 fL < MCV ≤ 70 fL, MCV ≤ 60 fL. Receiver operating characteristic curve analysis showed that a 73.5fL cutoff of MCV was highly sensitive in predicting falsely increased platelet counts.Conclusion: In cases with MCV < 73.5 fL, we strongly suggest that the platelet counts obtained by the impedance method on the Sysmex XN9000 analyzer should be checked and corrected by fluorescence counting.
- 17 June 2022
- Published by Oxford University Press (OUP) in Laboratory Medicine
- Vol. 54 (1) , e10-e13
Application of the Fluorescence Method on Sysmex XN9000 Hematology Analyzer for Correcting Platelet Count in Individuals with Microcytosis
Objective: Although small red blood cells are a well-known analytical pitfall that could cause artifactual increase of the platelet count, limited information is available on the accuracy of impedance platelet counting in cases with microcytosis. The aim of this study is to assess the accuracy of impedance platelet counting in the presence of small red blood cells, and to establish the optimal mean corpuscular volume (MCV) cutoff to endorse fluorescence platelet counting.Methods: In this study, platelet counts estimated by the impedance method on the Sysmex XN9000 analyzer (Sysmex, Kobe, Japan) were compared with those provided by the fluorescence method. The accuracy of impedance platelet counting was assessed. Receiver operating characteristic curve was used to evaluate the performance of MCV in predicting falsely increased platelet counts.Results: There was a tendency for the impedance method to overestimate the platelet count in samples with 70 fL < MCV ≤ 80 fL, 60 fL < MCV ≤ 70 fL, MCV ≤ 60 fL. Receiver operating characteristic curve analysis showed that a 73.5fL cutoff of MCV was highly sensitive in predicting falsely increased platelet counts.Conclusion: In cases with MCV < 73.5 fL, we strongly suggest that the platelet counts obtained by the impedance method on the Sysmex XN9000 analyzer should be checked and corrected by fluorescence counting.
- 1 March 2020
- Published by Elsevier in Clinica Chimica Acta
- Vol. 502, 99-101
Mindray SF-Cube technology: An effective way for correcting platelet count in individuals with EDTA dependent pseudo thrombocytopenia
- 1 March 2020
- Published by Elsevier in Clinica Chimica Acta
- Vol. 502, 99-101
Mindray SF-Cube technology: An effective way for correcting platelet count in individuals with EDTA dependent pseudo thrombocytopenia