Ligang Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ligang Ding has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Yan Yao
Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College , Beijing
7 shared publications - Le Li
National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College , No.167 Beilishi Road, Beijing 100037
4 shared publications - Yulong Xiong
National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College , No.167 Beilishi Road, Beijing 100037
4 shared publications - Zhenhao Zhang
Cardiac Arrhythmia Center Fuwai Hospital National Key Laboratory National Center for Cardiovascular Diseases Chinese Academy of Medical Sciences and Peking Union Medical College Beijing China cacms.ac.cn
4 shared publications - Wei Hua
Cardiac Arrhythmia Center, Department of Cardiology, National Center for Cardiovascular Diseases, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
3 shared publications - Zhuxin Zhang
Arrhythmia Center, Fuwai Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College National Center for Cardiovascular Diseases, Fuwai Hospital Beijing China
3 shared publications
Latest Publications
- Open Access
- 13 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (13) , 1595-1605
Left bundle branch vs biventricular pacing: mechanistic insights from a canine model
Background and Aims: Left bundle branch pacing (LBBP) for cardiac resynchronization therapy is emerging as an alternative pacing strategy to biventricular pacing (BiVP) in dyssynchronous heart failure (DHF). This study aimed to explore the differences in treatment effects between the two pacing modalities using electrocardiographic, echocardiographic, and molecular measurements. Methods: Adult canines underwent left bundle branch ablation, then either followed by 6 weeks of atrial tachypacing (DHF group, n = 8), or 3 weeks of atrial tachypacing followed by another 3 weeks of BiVP (n = 8) or LBBP (n = 8) tachypacing. Non-intervened canines constituted the control group (n = 7). Electrocardiographic, echocardiographic, and molecular features were compared between BiVP-treated and LBBP-treated DHF canines. Results: BiVP- and LBBP-treated canines achieved equivalent reduction in QRS duration (32 ± 6 ms vs 35 ± 5 ms, P = .276). Both BiVP and LBBP increased left ventricular ejection fraction (9 ± 5% and 10 ± 4%, respectively; P = .390) while LBBP significantly outperformed BiVP in improving left ventricular global longitudinal strain (−3.7 ± 1.2% vs −2.3 ± 1.0%, P = .019). Both BiVP and LBBP reversed biomarkers of heart failure, while LBBP more significantly modulated cytoskeleton proteins, TGF-β signalling pathways and SERCA2a expression. Moreover, LBBP contributed to a more comprehensive improvement in myocardial energy metabolism compared to BiVP. Conclusions: This study in a DHF animal model indicates that LBBP results in electrocardiographic, echocardiographic, and molecular recovery at least as good as that during BiVP. The superiority of LBBP is especially reflected in more pronounced normalization of cardiac cytoskeleton, calcium handling and energy metabolism.
- 13 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 47 (13) , 1595-1605
Open AccessLeft bundle branch vs biventricular pacing: mechanistic insights from a canine model
Background and Aims: Left bundle branch pacing (LBBP) for cardiac resynchronization therapy is emerging as an alternative pacing strategy to biventricular pacing (BiVP) in dyssynchronous heart failure (DHF). This study aimed to explore the differences in treatment effects between the two pacing modalities using electrocardiographic, echocardiographic, and molecular measurements. Methods: Adult canines underwent left bundle branch ablation, then either followed by 6 weeks of atrial tachypacing (DHF group, n = 8), or 3 weeks of atrial tachypacing followed by another 3 weeks of BiVP (n = 8) or LBBP (n = 8) tachypacing. Non-intervened canines constituted the control group (n = 7). Electrocardiographic, echocardiographic, and molecular features were compared between BiVP-treated and LBBP-treated DHF canines. Results: BiVP- and LBBP-treated canines achieved equivalent reduction in QRS duration (32 ± 6 ms vs 35 ± 5 ms, P = .276). Both BiVP and LBBP increased left ventricular ejection fraction (9 ± 5% and 10 ± 4%, respectively; P = .390) while LBBP significantly outperformed BiVP in improving left ventricular global longitudinal strain (−3.7 ± 1.2% vs −2.3 ± 1.0%, P = .019). Both BiVP and LBBP reversed biomarkers of heart failure, while LBBP more significantly modulated cytoskeleton proteins, TGF-β signalling pathways and SERCA2a expression. Moreover, LBBP contributed to a more comprehensive improvement in myocardial energy metabolism compared to BiVP. Conclusions: This study in a DHF animal model indicates that LBBP results in electrocardiographic, echocardiographic, and molecular recovery at least as good as that during BiVP. The superiority of LBBP is especially reflected in more pronounced normalization of cardiac cytoskeleton, calcium handling and energy metabolism.
- Open Access
- 1 January 2026
- Published by Wiley in Anesthesiology Research and Practice
- Vol. 2026 (1) , 4197770
Electrophysiology Team–Administered Conscious Sedation for Pulsed‐Field Versus Radiofrequency Ablation in Atrial Fibrillation
Background: Pulsed‐field ablation (PFA) is emerging as a novel nonthermal alternative. However, PFA is commonly performed under general anesthesia or deep sedation requiring anesthesiologists, which increases resource utilization and limits its widespread application. This study aimed to evaluate the feasibility of conscious sedation for PFA administered by the electrophysiology (EP) team, using radiofrequency ablation (RFA) as a comparator. Methods: A total of 120 patients with symptomatic, drug‐refractory atrial fibrillation were randomized in a 1:1 ratio to the PFA group or the RFA group. We evaluated three key outcomes: (1) intraoperative patient tolerance, assessed using validated scales (Faces Pain Scale‐Revised [FPS‐R], Likert Scale Questionnaire [LSQ]) combined with intraoperative body movement and cough reactions; (2) procedural efficiency; and (3) procedural safety. Results: The incidence of pain during pulmonary vein isolation was comparable between the two groups (all p > 0.05), whereas FPS‐R scores were significantly lower in the PFA group ( p < 0.05). No significant difference was observed in movement scores between the two groups ( p = 0.452). According to the LSQ analysis, only 1 patient (1.7%) in the RFA group reported dissatisfaction with intraoperative pain management. Cough incidence during PVI was higher with PFA (21.7% [13/60] vs 6.7% [4/60]; p = 0.018). Both total procedure time and left atrial dwell time were shorter in the PFA group. Furthermore, no serious complications were directly related to conscious sedation. Conclusion: In selected low‐risk patients, EP team–administered conscious sedation is feasible for PFA, with acceptable intraoperative tolerance and safety while preserving procedural efficiency.
- 1 January 2026
- Published by Wiley in Anesthesiology Research and Practice
- Vol. 2026 (1) , 4197770
Open AccessElectrophysiology Team–Administered Conscious Sedation for Pulsed‐Field Versus Radiofrequency Ablation in Atrial Fibrillation
Background: Pulsed‐field ablation (PFA) is emerging as a novel nonthermal alternative. However, PFA is commonly performed under general anesthesia or deep sedation requiring anesthesiologists, which increases resource utilization and limits its widespread application. This study aimed to evaluate the feasibility of conscious sedation for PFA administered by the electrophysiology (EP) team, using radiofrequency ablation (RFA) as a comparator. Methods: A total of 120 patients with symptomatic, drug‐refractory atrial fibrillation were randomized in a 1:1 ratio to the PFA group or the RFA group. We evaluated three key outcomes: (1) intraoperative patient tolerance, assessed using validated scales (Faces Pain Scale‐Revised [FPS‐R], Likert Scale Questionnaire [LSQ]) combined with intraoperative body movement and cough reactions; (2) procedural efficiency; and (3) procedural safety. Results: The incidence of pain during pulmonary vein isolation was comparable between the two groups (all p > 0.05), whereas FPS‐R scores were significantly lower in the PFA group ( p < 0.05). No significant difference was observed in movement scores between the two groups ( p = 0.452). According to the LSQ analysis, only 1 patient (1.7%) in the RFA group reported dissatisfaction with intraoperative pain management. Cough incidence during PVI was higher with PFA (21.7% [13/60] vs 6.7% [4/60]; p = 0.018). Both total procedure time and left atrial dwell time were shorter in the PFA group. Furthermore, no serious complications were directly related to conscious sedation. Conclusion: In selected low‐risk patients, EP team–administered conscious sedation is feasible for PFA, with acceptable intraoperative tolerance and safety while preserving procedural efficiency.
- Open Access
- 31 October 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (11)
First in vivo robotic-assisted pulsed field ablation for atrial fibrillation in a swine model: a case report
Background: Robotic-assisted procedures are rapidly advancing in interventional cardiology and have shown advantages in performing atrial fibrillation ablation. However, their application in combination with pulsed field ablation (PFA) remains unexplored. Case summary: We report the first in vivo experience of robotic-assisted PFA. The robotic-assisted PFA system comprises of a robotic articulating arm with three sterile, single-use functional modules, a workstation console, and a control computer. Following transseptal puncture and electrical mapping, two experienced operators performed pulmonary vein isolation and superior vena cava isolation in a swine model using the robotic system integrated with a guiding sheath and a PFA catheter. The procedure was conducted under fluoroscopy, while operators controlled the system remotely via the console in a zero-radiation environment. Post-procedural voltage mapping and histological analysis confirmed the feasibility of robotic-assisted PFA. Discussion: The primary advantage of robotic-assisted PFA is the potential to enable remote operation. It may also improve catheter stability and reduce the learning curve for performing PFA. Potential risks of robotic-assisted PFA include violent damage to cardiac tissue and complications associated with PFA. The robotic-assisted PFA system is sensitive and accurate when operated on a swine model, though several challenges exist in translating findings from a swine model to human clinical practice, and further studies are needed to evaluate its safety and efficacy before clinical implementation.
- 31 October 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (11)
Open AccessFirst in vivo robotic-assisted pulsed field ablation for atrial fibrillation in a swine model: a case report
Background: Robotic-assisted procedures are rapidly advancing in interventional cardiology and have shown advantages in performing atrial fibrillation ablation. However, their application in combination with pulsed field ablation (PFA) remains unexplored. Case summary: We report the first in vivo experience of robotic-assisted PFA. The robotic-assisted PFA system comprises of a robotic articulating arm with three sterile, single-use functional modules, a workstation console, and a control computer. Following transseptal puncture and electrical mapping, two experienced operators performed pulmonary vein isolation and superior vena cava isolation in a swine model using the robotic system integrated with a guiding sheath and a PFA catheter. The procedure was conducted under fluoroscopy, while operators controlled the system remotely via the console in a zero-radiation environment. Post-procedural voltage mapping and histological analysis confirmed the feasibility of robotic-assisted PFA. Discussion: The primary advantage of robotic-assisted PFA is the potential to enable remote operation. It may also improve catheter stability and reduce the learning curve for performing PFA. Potential risks of robotic-assisted PFA include violent damage to cardiac tissue and complications associated with PFA. The robotic-assisted PFA system is sensitive and accurate when operated on a swine model, though several challenges exist in translating findings from a swine model to human clinical practice, and further studies are needed to evaluate its safety and efficacy before clinical implementation.
- Top Cited Papers
- 21 February 2025
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 46 (18) , 1733-1743
Atrial fibrillation catheter ablation, brain glymphatic function, and cognitive performance
Background and Aims: It remains unknown whether the brain glymphatic system, which is driven by the heartbeat-driven pulsation of arteries and is responsible for cerebral waste clearance, is impaired in atrial fibrillation (AF) and mediates cognitive dysfunction related to AF. The aim of this study was to assess brain glymphatic alterations in AF, their role in cognitive function, and whether catheter ablation can improve glymphatic activity. Methods: In this case-control and prospective before–and–after study, patients with AF and healthy controls (HCs) were enrolled. Participants underwent brain magnetic resonance imaging and a comprehensive neuropsychological battery. Glymphatic activity was quantified by diffusion tensor image analysis along the perivascular space (DTI-ALPS) index. Magnetic resonance imaging was repeated after surgery in patients who underwent ablation. Results: Overall, 87 patients with AF and 44 HCs were enrolled. Compared with HCs, patients with AF had a lower ALPS index (P = .016). Nonparoxysmal AF patients showed lower ALPS index than both HCs (P = .002) and paroxysmal AF patients (P = .044). A lower ALPS index was associated with worse scores of Trail Making Test, Digit Symbol Substitution Test, Digit Span Test, and Stroop Colour and Word Test (all P < .05). Mediation analyses revealed that glymphatic activity was a mediator between AF and cognitive decline. Among the 50 patients who underwent ablation therapy, DTI-ALPS index was improved after surgery (P = .015). Conclusions: Brain glymphatic function measured by DTI-ALPS index was impaired in patients with AF, mediates the association between AF and cognitive decline, and was improved after ablation therapy.
- 21 February 2025
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 46 (18) , 1733-1743
Top Cited PapersAtrial fibrillation catheter ablation, brain glymphatic function, and cognitive performance
Background and Aims: It remains unknown whether the brain glymphatic system, which is driven by the heartbeat-driven pulsation of arteries and is responsible for cerebral waste clearance, is impaired in atrial fibrillation (AF) and mediates cognitive dysfunction related to AF. The aim of this study was to assess brain glymphatic alterations in AF, their role in cognitive function, and whether catheter ablation can improve glymphatic activity. Methods: In this case-control and prospective before–and–after study, patients with AF and healthy controls (HCs) were enrolled. Participants underwent brain magnetic resonance imaging and a comprehensive neuropsychological battery. Glymphatic activity was quantified by diffusion tensor image analysis along the perivascular space (DTI-ALPS) index. Magnetic resonance imaging was repeated after surgery in patients who underwent ablation. Results: Overall, 87 patients with AF and 44 HCs were enrolled. Compared with HCs, patients with AF had a lower ALPS index (P = .016). Nonparoxysmal AF patients showed lower ALPS index than both HCs (P = .002) and paroxysmal AF patients (P = .044). A lower ALPS index was associated with worse scores of Trail Making Test, Digit Symbol Substitution Test, Digit Span Test, and Stroop Colour and Word Test (all P < .05). Mediation analyses revealed that glymphatic activity was a mediator between AF and cognitive decline. Among the 50 patients who underwent ablation therapy, DTI-ALPS index was improved after surgery (P = .015). Conclusions: Brain glymphatic function measured by DTI-ALPS index was impaired in patients with AF, mediates the association between AF and cognitive decline, and was improved after ablation therapy.
- Open Access
- 1 January 2025
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 29 (11) , 619-629
Association Between Triglyceride-Glucose Index and Prognosis of Patients with Hypertrophic Cardiomyopathy and Heart Failure with Preserved Ejection Fraction
The Anatolian Journal of Cardiology - Peer-reviewed cardiology journal publishing original research, reviews, case reports. Impact Factor 1.5. The Anatolian Journal of Cardiology - Leading international cardiology journal with Impact Factor 1.5. Publishing original research, reviews, and case reports in cardiovascular medicine. Indexed in PubMed, Scopus, and Web of Science.
- 1 January 2025
- Published by Kare Publishing in The Anatolian Journal of Cardiology
- Vol. 29 (11) , 619-629
Open AccessAssociation Between Triglyceride-Glucose Index and Prognosis of Patients with Hypertrophic Cardiomyopathy and Heart Failure with Preserved Ejection Fraction
The Anatolian Journal of Cardiology - Peer-reviewed cardiology journal publishing original research, reviews, case reports. Impact Factor 1.5. The Anatolian Journal of Cardiology - Leading international cardiology journal with Impact Factor 1.5. Publishing original research, reviews, and case reports in cardiovascular medicine. Indexed in PubMed, Scopus, and Web of Science.
- Open Access
- 15 November 2023
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 25 (1) , e47664
Development and Validation of Machine Learning–Based Models to Predict In-Hospital Mortality in Life-Threatening Ventricular Arrhythmias: Retrospective Cohort Study
Background: Life-threatening ventricular arrhythmias (LTVAs) are main causes of sudden cardiac arrest and are highly associated with an increased risk of mortality. A prediction model that enables early identification of the high-risk individuals is still lacking. Objective: We aimed to build machine learning (ML)–based models to predict in-hospital mortality in patients with LTVA. Methods: A total of 3140 patients with LTVA were randomly divided into training (n=2512, 80%) and internal validation (n=628, 20%) sets. Moreover, data of 2851 patients from another database were collected as the external validation set. The primary output was the probability of in-hospital mortality. The discriminatory ability was evaluated by the area under the receiver operating characteristic curve (AUC). The prediction performances of 5 ML algorithms were compared with 2 conventional scoring systems, namely, the simplified acute physiology score (SAPS-II) and the logistic organ dysfunction system (LODS). Results: The prediction performance of the 5 ML algorithms significantly outperformed the traditional models in predicting in-hospital mortality. CatBoost showed the highest AUC of 90.5% (95% CI 87.5%-93.5%), followed by LightGBM with an AUC of 90.1% (95% CI 86.8%-93.4%). Conversely, the predictive values of SAPS-II and LODS were unsatisfactory, with AUCs of 78.0% (95% CI 71.7%-84.3%) and 74.9% (95% CI 67.2%-82.6%), respectively. The superiority of ML-based models was also shown in the external validation set. Conclusions: ML-based models could improve the predictive values of in-hospital mortality prediction for patients with LTVA compared with traditional scoring systems.
- 15 November 2023
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 25 (1) , e47664
Open AccessDevelopment and Validation of Machine Learning–Based Models to Predict In-Hospital Mortality in Life-Threatening Ventricular Arrhythmias: Retrospective Cohort Study
Background: Life-threatening ventricular arrhythmias (LTVAs) are main causes of sudden cardiac arrest and are highly associated with an increased risk of mortality. A prediction model that enables early identification of the high-risk individuals is still lacking. Objective: We aimed to build machine learning (ML)–based models to predict in-hospital mortality in patients with LTVA. Methods: A total of 3140 patients with LTVA were randomly divided into training (n=2512, 80%) and internal validation (n=628, 20%) sets. Moreover, data of 2851 patients from another database were collected as the external validation set. The primary output was the probability of in-hospital mortality. The discriminatory ability was evaluated by the area under the receiver operating characteristic curve (AUC). The prediction performances of 5 ML algorithms were compared with 2 conventional scoring systems, namely, the simplified acute physiology score (SAPS-II) and the logistic organ dysfunction system (LODS). Results: The prediction performance of the 5 ML algorithms significantly outperformed the traditional models in predicting in-hospital mortality. CatBoost showed the highest AUC of 90.5% (95% CI 87.5%-93.5%), followed by LightGBM with an AUC of 90.1% (95% CI 86.8%-93.4%). Conversely, the predictive values of SAPS-II and LODS were unsatisfactory, with AUCs of 78.0% (95% CI 71.7%-84.3%) and 74.9% (95% CI 67.2%-82.6%), respectively. The superiority of ML-based models was also shown in the external validation set. Conclusions: ML-based models could improve the predictive values of in-hospital mortality prediction for patients with LTVA compared with traditional scoring systems.
- Open Access
- 27 October 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Outcomes of catheter ablation in high-risk patients with Brugada syndrome refusing an implantable cardioverter defibrillator implantation
The aim of this study was to investigate the outcomes of catheter ablation (CA) in preventing arrhythmic events among patients with symptomatic Brugada syndrome (BrS) who declined implantable cardioverter defibrillator (ICD) implantation. A total of 40 patients with symptomatic BrS were included in the study, of which 18 refused ICD implantation and underwent CA, while 22 patients received ICD implantation. The study employed substrate modification (including endocardial and epicardial approaches) and ventricular fibrillation (VF)-triggering pre-mature ventricular contraction (PVC) ablation strategies. The primary outcomes were a composite endpoint consisting of episodes of VF and sudden cardiac death during the follow-up period. The study population had a mean age of 43.8 ± 9.6 years, with 36 (90.0%) of them being male. All patients exhibited the typical Type 1 BrS electrocardiogram pattern, and 16 (40.0%) were carriers of an SCN5A mutation. The Shanghai risk scores were comparable between the CA and the ICD groups (7.05 ± 0.80 vs. 6.71 ± 0.86, P = 0.351). Ventricular fibrillation–triggering PVCs were ablated in 3 patients (16.7%), while VF substrates were ablated in 15 patients (83.3%). Epicardial ablation was performed in 12 patients (66.7%). During a median follow-up of 46.2 (17.5–73.7) months, the primary outcomes occurred more frequently in the ICD group than in the CA group (5.6 vs. 54.5%, Log-rank P = 0.012). Catheter ablation is an effective alternative therapy for improving arrhythmic outcomes in patients with symptomatic BrS who decline ICD implantation. Our findings support the consideration of CA as an alternative treatment option in this population. The left figure shows an example of Brugada syndrome phenotype abolition by catheter ablation (CA). After the epicardial ablation, the maximum amplitude of ST elevation of Lead V1 was significantly decreased (0.420–0.244 mV), and the local low-voltage area was nearly eliminated. The right figure illustrates the Kaplan–Meier curve of arrhythmic events (cardiac death/ventricular fibrillation) for patients received CA vs. implantable cardioverter defibrillator.
- 27 October 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (1)
Open AccessOutcomes of catheter ablation in high-risk patients with Brugada syndrome refusing an implantable cardioverter defibrillator implantation
The aim of this study was to investigate the outcomes of catheter ablation (CA) in preventing arrhythmic events among patients with symptomatic Brugada syndrome (BrS) who declined implantable cardioverter defibrillator (ICD) implantation. A total of 40 patients with symptomatic BrS were included in the study, of which 18 refused ICD implantation and underwent CA, while 22 patients received ICD implantation. The study employed substrate modification (including endocardial and epicardial approaches) and ventricular fibrillation (VF)-triggering pre-mature ventricular contraction (PVC) ablation strategies. The primary outcomes were a composite endpoint consisting of episodes of VF and sudden cardiac death during the follow-up period. The study population had a mean age of 43.8 ± 9.6 years, with 36 (90.0%) of them being male. All patients exhibited the typical Type 1 BrS electrocardiogram pattern, and 16 (40.0%) were carriers of an SCN5A mutation. The Shanghai risk scores were comparable between the CA and the ICD groups (7.05 ± 0.80 vs. 6.71 ± 0.86, P = 0.351). Ventricular fibrillation–triggering PVCs were ablated in 3 patients (16.7%), while VF substrates were ablated in 15 patients (83.3%). Epicardial ablation was performed in 12 patients (66.7%). During a median follow-up of 46.2 (17.5–73.7) months, the primary outcomes occurred more frequently in the ICD group than in the CA group (5.6 vs. 54.5%, Log-rank P = 0.012). Catheter ablation is an effective alternative therapy for improving arrhythmic outcomes in patients with symptomatic BrS who decline ICD implantation. Our findings support the consideration of CA as an alternative treatment option in this population. The left figure shows an example of Brugada syndrome phenotype abolition by catheter ablation (CA). After the epicardial ablation, the maximum amplitude of ST elevation of Lead V1 was significantly decreased (0.420–0.244 mV), and the local low-voltage area was nearly eliminated. The right figure illustrates the Kaplan–Meier curve of arrhythmic events (cardiac death/ventricular fibrillation) for patients received CA vs. implantable cardioverter defibrillator.
- Open Access
- 28 March 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Development and Validation of Machine Learning–Based Models to Predict In-Hospital Mortality in Life-Threatening Ventricular Arrhythmias: Retrospective Cohort Study (Preprint)
BACKGROUND Life-threatening ventricular arrhythmias (LTVAs) are main causes of sudden cardiac arrest and are highly associated with an increased risk of mortality. A prediction model that enables early identification of the high-risk individuals is still lacking. OBJECTIVE We aimed to build machine learning (ML)–based models to predict in-hospital mortality in patients with LTVA. METHODS A total of 3140 patients with LTVA were randomly divided into training (n=2512, 80%) and internal validation (n=628, 20%) sets. Moreover, data of 2851 patients from another database were collected as the external validation set. The primary output was the probability of in-hospital mortality. The discriminatory ability was evaluated by the area under the receiver operating characteristic curve (AUC). The prediction performances of 5 ML algorithms were compared with 2 conventional scoring systems, namely, the simplified acute physiology score (SAPS-II) and the logistic organ dysfunction system (LODS). RESULTS The prediction performance of the 5 ML algorithms significantly outperformed the traditional models in predicting in-hospital mortality. CatBoost showed the highest AUC of 90.5% (95% CI 87.5%-93.5%), followed by LightGBM with an AUC of 90.1% (95% CI 86.8%-93.4%). Conversely, the predictive values of SAPS-II and LODS were unsatisfactory, with AUCs of 78.0% (95% CI 71.7%-84.3%) and 74.9% (95% CI 67.2%-82.6%), respectively. The superiority of ML-based models was also shown in the external validation set. CONCLUSIONS ML-based models could improve the predictive values of in-hospital mortality prediction for patients with LTVA compared with traditional scoring systems.
- 28 March 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDevelopment and Validation of Machine Learning–Based Models to Predict In-Hospital Mortality in Life-Threatening Ventricular Arrhythmias: Retrospective Cohort Study (Preprint)
BACKGROUND Life-threatening ventricular arrhythmias (LTVAs) are main causes of sudden cardiac arrest and are highly associated with an increased risk of mortality. A prediction model that enables early identification of the high-risk individuals is still lacking. OBJECTIVE We aimed to build machine learning (ML)–based models to predict in-hospital mortality in patients with LTVA. METHODS A total of 3140 patients with LTVA were randomly divided into training (n=2512, 80%) and internal validation (n=628, 20%) sets. Moreover, data of 2851 patients from another database were collected as the external validation set. The primary output was the probability of in-hospital mortality. The discriminatory ability was evaluated by the area under the receiver operating characteristic curve (AUC). The prediction performances of 5 ML algorithms were compared with 2 conventional scoring systems, namely, the simplified acute physiology score (SAPS-II) and the logistic organ dysfunction system (LODS). RESULTS The prediction performance of the 5 ML algorithms significantly outperformed the traditional models in predicting in-hospital mortality. CatBoost showed the highest AUC of 90.5% (95% CI 87.5%-93.5%), followed by LightGBM with an AUC of 90.1% (95% CI 86.8%-93.4%). Conversely, the predictive values of SAPS-II and LODS were unsatisfactory, with AUCs of 78.0% (95% CI 71.7%-84.3%) and 74.9% (95% CI 67.2%-82.6%), respectively. The superiority of ML-based models was also shown in the external validation set. CONCLUSIONS ML-based models could improve the predictive values of in-hospital mortality prediction for patients with LTVA compared with traditional scoring systems.
- Open Access
- 20 November 2019
- Published by XMLink in International Journal of Arrhythmia
- Vol. 20 (1) , 1-7
Successful case of complex atrial flutter occurring in a patient with congenitally corrected transposition of the great arteries, aberrant left atrial appendage, and situs inversus
Background: Congenitally corrected transposition of great arteries (ccTGA) is a rare congenital cardiac defect with atrioventricular and ventriculoarterial discordance which leads to heart failure and limits patients’ lifespan. The extremely aberrant cardiac structure makes electrophysiological procedure and radiofrequency ablation very difficult to be performed in such patients. Until now, there were only sporadical cases that have reported the successful ablation of atrial flutter in ccTGA patients. Case presentation: We report a case of a 36-year-old male who was diagnosed with dextrocardia, atrial septal defect and congenitally corrected transposition of great arteries (ccTGA) at a young age and received atrial septal defect repair and morphological tricuspid valve plasty in 2014. As for reasons of heart failure and atrial flutter, he frequently suffered from progressively worsening dyspnea and recurrent episodes of palpitations. Cardiac anatomic imaging reconstruction before electrophysiological test revealed an unusually huge left atrial appendage in this patient. After high-density mapping of both right atrium and left atrium, activation mapping showed reentry circuit loops were located in left atrium. Successful ablation strategy was performed under the guidance of high-density mapping and entrainment. Conclusion: This is a clinical case showing high-density mapping and successful ablation of a complex dual-loop atrial flutter in a patient with ccTGA and aberrant left atrial appendage. The successful procedure corroborates clinical utility of high-density mapping approach in the treatment of the patients with complex congenital heart disease accompanied by rapid arrhythmia, can be simpler, safer and more effective.
- 20 November 2019
- Published by XMLink in International Journal of Arrhythmia
- Vol. 20 (1) , 1-7
Open AccessSuccessful case of complex atrial flutter occurring in a patient with congenitally corrected transposition of the great arteries, aberrant left atrial appendage, and situs inversus
Background: Congenitally corrected transposition of great arteries (ccTGA) is a rare congenital cardiac defect with atrioventricular and ventriculoarterial discordance which leads to heart failure and limits patients’ lifespan. The extremely aberrant cardiac structure makes electrophysiological procedure and radiofrequency ablation very difficult to be performed in such patients. Until now, there were only sporadical cases that have reported the successful ablation of atrial flutter in ccTGA patients. Case presentation: We report a case of a 36-year-old male who was diagnosed with dextrocardia, atrial septal defect and congenitally corrected transposition of great arteries (ccTGA) at a young age and received atrial septal defect repair and morphological tricuspid valve plasty in 2014. As for reasons of heart failure and atrial flutter, he frequently suffered from progressively worsening dyspnea and recurrent episodes of palpitations. Cardiac anatomic imaging reconstruction before electrophysiological test revealed an unusually huge left atrial appendage in this patient. After high-density mapping of both right atrium and left atrium, activation mapping showed reentry circuit loops were located in left atrium. Successful ablation strategy was performed under the guidance of high-density mapping and entrainment. Conclusion: This is a clinical case showing high-density mapping and successful ablation of a complex dual-loop atrial flutter in a patient with ccTGA and aberrant left atrial appendage. The successful procedure corroborates clinical utility of high-density mapping approach in the treatment of the patients with complex congenital heart disease accompanied by rapid arrhythmia, can be simpler, safer and more effective.
- Open Access
- 1 January 2019
- Vol. 16 (7) , 514-521
Predictors of non-response to cardiac resynchronization therapy implantation in patients with class I indications: the markedly dilated left ventricular end-diastolic dimension and the presence of fragmented QRS
Cardiac resynchronization therapy (CRT) is a highly effective treatment in patients with a class I recommendation. However, a small proportion of the strictly selected patients still fail to respond. This study was designed to identify predictors of non-response in patients with class I indications for CRT and determine the non-response probability of the patients. A total of 296 consecutive patients with a class I recommendation received CRT from January 2009 to January 2017 were retrospectively analyzed. Multivariate logistic regression analysis was performed to identify predictors for non-response (defined as cardiac death, heart transplantation, or HF hospitalization during 1-year follow-up). Among 296 patients, 30 (10.1%) met non-response. Multivariate analysis demonstrated that non-response to CRT was associated with a fragmented QRS (odd ratio (OR) = 2.86, 95% CI: 1.14-7.12; P = 0.025) and left ventricular end-diastolic dimension (LVEDD) ≥ 77 mm (OR = 3.02, 95% CI: 1.17-7.82; P = 0.022). Patients with both of the predictors had a non-response probability of 46.2% (95% CI: 19.1%-73.3%). In patients with left bundle branch block and wider QRS duration, the proportion of non-response to CRT is not low in real world. The presence of the dilated LVEDD or fragmented QRS is a strong predictor of non-response to CRT. The probability of non-response in the patients with the two predictors was 46.2%.
- 1 January 2019
- Vol. 16 (7) , 514-521
Open AccessPredictors of non-response to cardiac resynchronization therapy implantation in patients with class I indications: the markedly dilated left ventricular end-diastolic dimension and the presence of fragmented QRS
Cardiac resynchronization therapy (CRT) is a highly effective treatment in patients with a class I recommendation. However, a small proportion of the strictly selected patients still fail to respond. This study was designed to identify predictors of non-response in patients with class I indications for CRT and determine the non-response probability of the patients. A total of 296 consecutive patients with a class I recommendation received CRT from January 2009 to January 2017 were retrospectively analyzed. Multivariate logistic regression analysis was performed to identify predictors for non-response (defined as cardiac death, heart transplantation, or HF hospitalization during 1-year follow-up). Among 296 patients, 30 (10.1%) met non-response. Multivariate analysis demonstrated that non-response to CRT was associated with a fragmented QRS (odd ratio (OR) = 2.86, 95% CI: 1.14-7.12; P = 0.025) and left ventricular end-diastolic dimension (LVEDD) ≥ 77 mm (OR = 3.02, 95% CI: 1.17-7.82; P = 0.022). Patients with both of the predictors had a non-response probability of 46.2% (95% CI: 19.1%-73.3%). In patients with left bundle branch block and wider QRS duration, the proportion of non-response to CRT is not low in real world. The presence of the dilated LVEDD or fragmented QRS is a strong predictor of non-response to CRT. The probability of non-response in the patients with the two predictors was 46.2%.