XZXinfang Zhang

Xinfang Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinfang Zhang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Scheme for braiding Majorana zero modes in vortices using STT-matrix

    by Guangyao Huang, Jibang Fu, Xiaofeng Yi, Weichen Wang, Bo Ren, Zhaohua Yang, Shichuan Xue, Xinfang Zhang, Mingtang Deng


  • Open Access

    Learning and forecasting open quantum dynamics with correlated noise

    by Xinfang Zhang, Zhihao Wu, Gregory A. L. White, Zhongcheng Xiang, Shun Hu, Zhihui Peng, Yong Liu, Dongning Zheng, Xiang Fu, Anqi Huang, et al.


  • Open Access

    Controlling the Surface Roughness of Surface-Electrode Ion Trap Based on Micro-Nano Fabrication

    by Yizhu Hou, Xinfang Zhang, Wei Wu, Ting Zhang, Pingxing Chen, Zhijiao Deng

    The surface-electrode ion trap is one of the most promising devices to realize large-scale and integrated quantum information processing. However, a series of problems are faced in the micro-nano fabrication of surface-electrode ion traps. A prominent one is the difficulty to control the thick film surface roughness. A rough electrode surface could produce excessive radio frequency (RF) loss and deteriorate trapping ability of the surface-electrode ion trap. In this paper, a thick film micro-nano fabrication technology to control the surface roughness is presented, which can reduce the roughness of thick film surface-electrode down to 6.2 nm, while being controllable between 6.2 nm and 45 nm. Therefore, it can also provide a basis for studying the influence of electrode surface roughness on trap performance. The micro-nano fabrication technology is not only suitable for surface-electrode ion traps with various configurations, but also be further applied to researches of MEMS, solar cells and surface science.


  • Open Access

    Convenient Real-Time Monitoring of the Contamination of Surface Ion Trap

    by Xinfang Zhang, Yizhu Hou, Ting Chen, Wei Wu, Pingxing Chen

    Recent studies indicated that contamination by adatoms on the surface ion trap can generate contact potential, leading to fluctuations in patch potential. By investigating contamination induced by surface adatoms during a loading process, a direct physical image of the contamination process and the relationship between the capacitance change and the contamination from surface adatoms is examined theoretically and experimentally. From the relationship, the contamination by surface adatoms and the effect of in situ treatment process can be monitored by the capacitance between electrodes in real time. This study is foundational to further research on anomalous heating with practical applications in quantum information processing from surface ion traps.

  • Open Access

    Versatile surface ion trap with fork junction for effective cooling

    by Xinfang Zhang, Baoquan Ou, Ting Chen, Yi Xie, Wei Wu, Pingxing Chen

    Scaling up and effective cooling of ions in surface ion traps are central challenges in quantum computing and quantum simulation with trapped ions. In this theoretical study, we propose a versatile surface ion trap. In the manipulation zone of our trap, a symmetric seven-wire geometry enables innate principal axes rotation of two parallel linear ion chains, which facilitates the cooling of ions along all principal axes of the trap. To alleviate contaminating the manipulation zone during ion loading, a symmetric five-wire (FW) geometry is designed as the loading zone. Moreover, a ‘fork junction’ connects the loading and manipulation zones, which also enables the shuttling and reordering of ions. A multi-objective optimization procedure suitable for arbitrary junction designs is described in detail, and we present the corresponding optimization results for the key components of our trap. The proposed versatile trap can be used in the construction of large-scale ion quantum processors. The trap can also be used as the multi-ion-mixer or the efficient ion beam splitter, which has potential applications in quantum simulation and quantum computing; further, it can be used for the research of two-dimensional ion crystals and can act as guides of quantum microscopes, such as for an electron beam splitter used for quantum matter-wave optics experiments. Interesting topics involving the spin–spin interactions between two ion chains can also be simulated in our trap.


  • Open Access

    Convenient Real-Time Monitoring of the Contamination of Surface Ion Trap

    by Xinfang Zhang, Yizhu Hou, Ting Chen, Wei Wu, Pingxing Chen

    Recent studies indicated that contamination by adatoms on the surface ion trap can generate contact potential, leading to fluctuations in patch potential. By investigating contamination induced by surface adatoms during a loading process, a direct physical image of the contamination process and the relationship between the capacitance change and the contamination from surface adatoms is examined theoretically and experimentally. From the relationship, the contamination by surface adatoms and the effect of in situ treatment process can be monitored by the capacitance between electrodes in real time. This study is foundational to further research on anomalous heating with practical applications in quantum information processing from surface ion traps.


  • Sniffing lung cancer related biomarkers using an oxidized graphene SAW sensor

    by Xin-Fang Zhang, Zheng-Wei Zhang, Yan-Lan He, Yi-Xing Liu, Shuang Li, Jing-Yue Fang, Xue-Ao Zhang, Gang Peng

    Decane is one of the volatile organic compounds (VOCs) in human breath. Successful detection of decane in human breath has vast prospects for early lung cancer diagnosis. In this paper, a novel detecting device based on a filter surface acoustic wave (SAW) gas sensor is presented. SAW sensors coated with a thin oxidized graphene film were used to detect decane in parts per million (ppm) concentrations. Control and signal detection circuits were designed using a vector network analyzer with a detection resolution of insertion loss down to 0.0001 dB. The results showed that the SAW sensor could respond quickly with great sensitivity when exposed to 0.2 ppm decane. This device shows tremendous potential in medical diagnosis and environmental assessment.