DSDandan Song

Dandan Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dandan Song has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Reinhilde Jacobs

    OMFS-IMPATH Research Group, Department of Imaging and Pathology, Catholic University Leuven, Leuven, Belgium

    6 shared publications
  • Constantinus Politis

    OMFS IMPATH research group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium

    4 shared publications
  • Sohaib Shujaat

    OMFS IMPATH research group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium

    4 shared publications
  • Sohaib Shujaat

    King Abdullah International Medical Research Center, Department of Maxillofacial Surgery & Diagnostic Sciences, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Ministry of National Guard Health Affairs, Riyadh, Kingdom of Saudi Arabia

    4 shared publications
  • Yan Huang

    OMFS IMPATH research group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium

    4 shared publications
  • Ivo Lambrichts

    Department of Morphology, Biomedical Research Institute, Hasselt University, Diepenbeek, Belgium

    3 shared publications

Latest Publications

  • Open Access

    Insights into the role of the N6-methyladenosine reader IGF2BP3 in the progression of oral squamous cell carcinoma and its connection to cell-cycle control

    by Dandan Song, Xiaofeng Dai, Minna Fu, Yang Sun, Xingwen Wu, Qianrong Zhou, Wei Bi, Jian Sun, Fei Yang, Youcheng Yu


  • Single‐cell RNA sequencing reveals the heterogeneity of epithelial cell and fibroblast cells from non‐ to metastatic lymph node OTSCC

    by Dandan Song, Fei Yang, Yang Sun, Xingwen Wu, Qianrong Zhou, Wei Bi, Jian Sun, Siyi Li, Youcheng Yu

    Lymph node metastasis (LNM) is one of the common features of oral tongue squamous cell carcinoma (OTSCC). LNM is also taken as a sign of advanced OTSCC and poor survival rate. Recently, single‐cell RNA sequencing has been applied in investigating the heterogeneity of tumor microenvironment and discovering the potential biomarkers for helping the diagnosis and prognosticating. Pathogenesis of LNM in OTSCC remains unknown. Specifically, cancer‐associated fibroblasts (CAFs) and epithelial tumor cells could foster the progression of tumors. Thus, in this study, we aimed to comprehensively analyze the roles of subpopulations of CAFs and epithelial tumor cells in lymph node metastatic OTSCC using the integration of OTSCC single‐cell RNA sequencing datasets. Four distinct subtypes of CAFs, namely vascular CAFs, myofibroblast CAFs, inflammatory CAFs, and growth arrest CAFs were successfully discovered in LNM tumor and confirmed the roles of GAS and PTN pathways in the progression of tumor metastasis. In addition, NKAIN2+ epithelial cells and FN1+ epithelial cells specifically exhibited an upregulation of PTN, NRG, MIF, and SPP1 signaling pathways in the metastatic OTSCC. In doing so, we put forth some potential biomarkers that could be utilized for the purpose of diagnosing and prognosticating OTSCC during its metastatic phase and tried to confirm by immunofluorescence assays.


  • Open Access

    Moving toward patient specificity for devising cone‐beam computed tomography field‐of‐views: A normative maxillary skeletal dimensional analysis

    by Sohaib Shujaat, Artúr Kesztyüs, Dandan Song, Tobias Regnstrand, Daniel Benchimol, Krisztian Nagy, Reinhilde Jacobs

    Background: A lack of evidence exists comprehensively assessing skeletal dimensions in a Caucasian population group at different ages.Aim: To provide age‐ and gender‐specific normative skeletal dimensional measurements of the maxillary region using cone‐beam computed tomography (CBCT) imaging.Design: Cone‐beam computed tomography images of Caucasian patients were acquired and divided into different age groups ranging from 8 to 20 years. Linear measurements were taken to evaluate seven distance‐based variables, which included anterior nasal spine‐posterior nasal spine (ANS‐PNS) distance, bilateral maxillary first molar's central fossae (CF) distance, palatal vault depth (PVD), bilateral palatal cementoenamel junction (PCEJ) distance, bilateral vestibular CEJ (VCEJ) distance, bilateral jugulare distance (Jug) and arch length (AL).Results: A total of 529 patients (243 male, 286 female) were selected. ANS‐PNS and PVD showed the highest change in dimensions from 8 to 20 years of age. On the contrary, AL had the least variability in all age groups. Male patients had larger dimensions and showed a significant change in all dimensional measurements (p < .001) than female patients.Conclusion: The maxillary linear dimensions varied across different age groups. The presented maxillary normative data could serve as a reference guide for devising patient‐specific CBCT field of views.


  • Osseoperception following dental implant treatment: A systematic review

    by Dandan Song, Sohaib Shujaat, Constantinus Politis, Kaan Orhan, Reinhilde Jacobs

    Objectives: Osseoperception is defined as the ability to perceive tactile sensation via mechanoreception in the peri‐implant environment. The objective was to systematically review the available literature on the osseoperception phenomenon following dental implant placement and to explore potential factors which might improve the perception capacity.Material and methods: A literature search was performed using PubMed, Cochrane, Embase, and Web of Science databases up to June 2021. Both human and animal studies assessing sensory capacity or innervation following implant placement were included in this review. Two reviewers independently performed the study selection, data extraction and quality assessment of the included studies. The methodological quality of the included papers was assessed using Cochrane risk of bias for human studies and SYRCLE’s risk of bias tool for animal studies.Results: The electronic search of databases yielded 1667 results. Following removal of duplicates, title and abstract screening and full‐text reading, 22 publications were eligible to be included in the review. Psychophysical evidence from 14 studies indicated a lower tactile function of implants, where active and passive threshold levels were found to be 5 and 50 times higher for implants compared to natural teeth, respectively. The neurophysiological evidence from three studies indicated cortical plasticity following dental implant placement, measured via trigeminal nerve evoked potentials and functional magnetic resonance imaging. Histological evidence from five studies demonstrated the presence of myelinated nerve fibres in the peri‐implant tissues. Additionally, immediate implant placement and loading showed beneficial effect on peri‐implant tissue (re)innervation; however, no other biological or physiological factors could be identified influencing osseoperception.Conclusions: The reported evidence supported the existence of so‐called osseoperception phenomenon for restoring the sensory feedback pathway following oral implant rehabilitation. Further studies are required to identify factors that might further assist physiological integration of the oral implants in the human body as such to approach natural oral function.


  • Estimation of the radiation dose for dental spectral cone-beam CT

    by Kaan Orhan, Ruben Pauwels, Yi Chen, Dandan Song, Reinhilde Jacobs

    Objectives: The purpose of this study was to estimate the radiation dose for a dental spectral cone-beam CT (SCBCT) unit at different scanning parameters. Methods: Radiation dose measurements were performed for a commercially available dental SCBCT. Scans were obtained at different exposure times and fields of view (FOV), both for non-spectral (25×18 cm, 14×18 cm, 14×12 cm, 9×9 cm, 6×6 cm) and spectral modes (14×18 cm, 14×12 cm, 9×9 cm, 6×6 cm) with the tube voltage alternating between 80 and 110 kV for spectral mode, and fixed at 110 kV for non-spectral mode. An ion chamber was used for air kerma and dose area product (DAP) measurements. The effective dose was estimated based on the mAs using previously published logarithmic curves for CBCT units with a similar X-ray spectrum. Results: The adult effective dose, in non-spectral mode, was 44-269 µSv for small FOVs, 131-336 µSv for the medium FOV, and 163-476 µSv for the large FOV. In spectral mode, the estimated adult effective doses were 96-206 µSv for small, 299 µSv for medium and 372 µSv for large FOV protocols. Paediatric effective doses were estimated to be 75% higher than corresponding adult doses. Conclusion: SCBCT showed comparable doses with other CBCT devices, but DAP values were generally above currently published DRLs. Spectral imaging might allow for artefact reduction at comparable dose levels, which should be assessed in further image quality studies at both a technical and diagnostic levels.


  • Open Access

    Effect of platelet-rich and platelet-poor plasma on 3D bone-to-implant contact: a preclinical micro-CT study

    by Dandan Song, Sohaib Shujaat, Yan Huang, Jeroen Van Dessel, Constantinus Politis, Ivo Lambrichts, Reinhilde Jacobs

    Background: Bone-to-implant contact ratio (BIC%) plays a critical role in secondary stability of osseointegrated dental implants. The aim of this study was to identify the correlation of 2D/3D micro-CT images with histology as a gold standard for evaluating BIC% and to investigate the influence of the platelet-rich plasma (PRP) and platelet-poor plasma (PPP) on 3D BIC% following delayed implant placement with delayed loading (DIP+DL). Methods: Nine beagle dogs were recruited. Following bilateral extraction of mandibular 3rd premolar, 4th premolar, and 1st molar, 54 screw-type titanium implants were inserted and randomly divided into one control and two test groups based on a split-mouth design. The control group involved DIP+DL (n = 18) and both test groups included DIP+DL with local application of PRP (n = 18) and PPP (n = 18). A BIC analysis was performed utilizing 2D histomorphometry and 2D/3D micro-CT. Following identification of correlation between histology and 2D/3D micro-CT images, a 3D micro-CT assessment of the 3D BIC% at three follow-up time-points (1, 3, and 6 months) was carried out for observing the influence of PRP and PPP on BIC. Results: The 2D micro-CT BIC% values revealed a strong positive correlation with histology (r = 0.98, p < 0.001) and a moderate correlation existed with 3D micro-CT (r = 0. 67, p = 0.005). BIC levels at 1 month and combined influence of PPP and PRP irrespective of time-points revealed significantly higher 3D BIC% compared to the control. However, a reduction in 3D BIC% was observed at the 3rd and 6th month. No significant difference was observed between both PRP and PPP. Conclusions: Both 2D and 3D micro-CT demonstrated a potential to be utilized as a complimentary method for assessing BIC compared to the histological gold standard. Overall, both PRP and PPP significantly facilitated bone healing and osseointegration with a higher 3D BIC at follow-up. However, their influence was reduced as the observation period was increased.


  • Open Access

    Diagnostic accuracy of CBCT versus intraoral imaging for assessment of peri‐implant bone defects

    by Dandan Song, Sohaib Shujaat, Karla de Faria Vasconcelos, Yan Huang, Constantinus Politis, Ivo Lambrichts, Reinhilde Jacobs

    Background: Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification, and measurement of peri-implant bone defects in an animal model. Methods: Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant. Results: Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI 0.86–0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95% CI 0.67–0.91). Conclusions: The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification, and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.


  • Open Access

    Diagnostic Accuracy of CBCT Versus Intraoral Imaging for Assessment of Peri‐implant Bone Defects

    by Dandan Song, Sohaib Shujaat, Karla de Faria Vasconcelos, Yan Huang, Constantinus Politis, Ivo Lambrichts, Reinhilde Jacobs

    Background: Early detection of marginal bone loss is vital for treatment planning and prognosis of teeth and implant. This study was conducted to assess diagnostic accuracy of CBCT compared to intra-oral (IO) radiography for detection, classification and measurement of peri-implant bone defects in an animal model.Methods: Fifty-four mandible blocks with implants were harvested from nine male health adult beagle dogs with acquisition of IO, CBCT and micro-CT images from all samples. Peri-implant bone defects from 16 samples were diagnosed using micro-CT and classified into 3 defect categories: dehiscence (n = 5), infrabony defect (n = 3) and crater-like defect (n = 8). Following training and calibration of the observers, they asked to detect location (mesial, distal, buccal, lingual) and shape of the defect (dehiscence, horizontal defect, vertical defect, carter-like defect) utilizing both IO and CBCT images. Both observers assessed defect depth and width on IO, CBCT and micro-CT images at each side of peri-implant bone defect via CT-analyzer software. Data were analyzed using SPSS software and a p value of < 0.05 was considered as statistically significant. Results: Overall, there was a high diagnostic accuracy for detection of bone defects with CBCT images (sensitivity: 100%/100%), while IO images showed a reduction in accuracy (sensitivity: 69%/63%). Similarly, diagnostic accuracy for defect classification was significantly higher for CBCT, whereas IO images were unable to correctly identify vestibular dehiscence, with incorrect assessment of half of the infrabony defects. For accuracy of measuring defect depth and width, a higher correlation was observed between CBCT and gold standard micro-CT (r = 0.91, 95% CI: 0.86-0.94), whereas a lower correlation was seen for IO images (r = 0.82, 95%CI: 0.67-0.91).Conclusions: The diagnostic accuracy and reliability of CBCT was found to be superior to IO imaging for the detection, classification and measurement of peri-implant bone defects. The application of CBCT adds substantial information related to the peri-implant bone defect diagnosis and decision-making which cannot be achieved with conventional IO imaging.

  • Open Access

    In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique

    by Dandan Song, Sohaib Shujaat, Ruiting Zhao, Yan Huang, Eman Shaheen, Jeroen Van Dessel, Kaan Orhan, Greetje Vande Velde, Ruxandra Coropciuc, Ruben Pauwels, et al.

    Purpose: This study was performed to introduce an in vivo hybrid multimodality technique involving the co-registration of micro-computed tomography (micro-CT) and high-resolution magnetic resonance imaging (HR-MRI) to concomitantly visualize and quantify mineralization and vascularization at follow-up in a rat model. Materials and Methods: Three adult female rats were randomly assigned as test subjects, with 1 rat serving as a control subject. For 20 weeks, the test rats received a weekly intravenous injection of 30 mu g/kg zoledronic acid, and the control rat was administered a similar dose of normal saline. Bilateral extraction of the lower first and second molars was performed after 10 weeks. All rats were scanned once every 4 weeks with both micro-CT and HR-MRI. Micro-CT and HR-MRI images were registered and fused in the same 3-dimensional region to quantify blood flow velocity and trabecular bone thickness at T0 (baseline), T4 (4 weeks), T8 (8 weeks), T12 (12 weeks), T16 (16 weeks), and T20 (20 weeks). Histological assessment was the gold standard with which the findings were compared. Results: The histomorphometric images at T20 aligned with the HR-MRI findings, with both test and control rats demonstrating reduced trabecular bone vasculature and blood vessel density. The micro-CT findings were also consistent with the histomorphometric changes, which revealed that the test rats had thicker trabecular bone and smaller marrow spaces than the control rat. Conclusion: The combination of micro-CT and HR-MRI may be considered a powerful non-invasive novel technique for the longitudinal quantification of localized mineralization and vascularization.


  • Open Access

    Peri‐implant myelinated nerve fibers: Histological findings in dogs

    by Dandan Song, Xin Liang, Hui Zheng, Sohaib Shujaat, Jeroen Van Dessel, Weijian Zhong, Guowu Ma, Ivo Lambrichts, Reinhilde Jacobs

    Background and Objective While osseointegration following various dental implant placement protocols has been extensively investigated, the neurohistological integration has received little attention. The primary aim of this study was to compare the myelinated nerve fibers density in peri‐implant bone tissue following various implant placement protocols. The secondary aim assessed the effect of follow‐up on peri‐implant nerve fibers density. Methods Ten beagle dogs randomly received 68 commercially pure titanium implants in the mandibular premolar or molar region bilaterally following extraction utilizing one of the six treatment protocols: (a) immediate implant placement (IIP) and immediate loading (IL); (b) IIP and delayed loading (DL); (c) IIP and left unloaded (UL); (d) delayed implant placement (DIP) and IL; (e) DIP and DL; and (f) DIP and UL. Histomorphometric analysis of the peri‐implant myelinated nerve fibers was performed in a 300 μm peri‐implant zone at the cervical, middle, and apical level following implant placement. The follow‐up assessment involved longitudinal observation at 3 months following each implant treatment protocol and at 6 months for IIP+IL and IIP+DL protocols. Results The influence of different treatment protocols, including the fixed effects of implant groups (IIP+IL, IIP+DL, IIP+UL, DIP+IL, DIP+DL, DIP+UL) and regions (cervical, middle, apical), was examined via a linear mixed model. The IIP+IL group showed a significantly higher myelinated nerve density compared to the IIP+UL and DIP+UL group. Peri‐implant nerve re‐innervation was significantly higher (P = .002) in the apical region compared to the cervical region. After immediate implant placement, the IL group showed a significantly (P = .03) higher density of myelinated nerve fibers compared to DL. No significant (P = .19) effect of follow‐up on nerve density was observed. Conclusion The immediate implant placement and loading protocol showed most beneficial effect on peri‐implant innervation with highest myelinated nerve density in the apical region. A longer loading time had no influence on the peri‐implant nerve density.