SLShibin Liu

Shibin Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shibin Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accuracy Evaluation of Calibrating Magnetic Tensor Gradiometers From Total-Field Gradient Measurements in Aeromagnetic Survey

    by Shibin Liu, Yangyi Sui, Hao Cheng, Zibo Zhang, David Clark

    The magnetic gradient tensor is the spatial rate of change of the magnetic vector along the three axes of the Cartesian coordinate system. It is particularly suitable for aeromagnetic surveys because it is relatively insensitive to temporal changes and regional variations of the geomagnetic field. However, the complexity of the flight environment and defects in the existing calibration methods for airborne magnetic tensor gradiometers cannot guarantee the measurement accuracy of tensor data. Research shows that the generalized Hilbert transform can convert total-field gradients, measured over an extensive survey area, into the magnetic gradient tensor components, so a high-precision total-field gradiometer can be employed to calibrate a magnetic tensor gradiometer, using a generalized Hilbert transform calibration method (GHTCM). However, practical survey conditions cannot meet the requirements of the generalized Hilbert transform, which degrades the accuracy of GHTCM. Based on the theory of the generalized Hilbert transform, we first analyze the error sources and error mechanisms of the GHTCM according to the differences between real and ideal survey conditions and then build models to design an appropriate evaluation algorithm for the accuracy of the GHTCM. Simulation experiments based on the open-source flight simulator, FlightGear, and a practical flight experiment are designed. The results indicate that the proposed method can correctly evaluate the accuracy of the GHTCM. This evaluation algorithm is the basis of obtaining the high-precision calibration data for practical airborne magnetic gradient tensor in the survey.


  • Open Access

    Error Analysis and Correction of a Downhole Rotating Magnetic Full-Tensor Gradiometer

    by Yangyi Sui, Wei He, Zhenghui Xia, Shibin Liu, Keith Leslie

    Compared with ground magnetic measurement and aeromagnetic survey, downhole magnetic measurements can provide more abundant and accurate distribution information of ore deposits. Measurement of the full magnetic tensor gradient affords more information than either traditional magnetic total field or three, orthogonal axes, vector field measurements. Gradient field measurements are less influenced by any time and/or spatial changes of the Earth’s magnetic field during the measurement period. CSIRO has developed the world first downhole magnetic full tensor gradiometer and carried out field tests. This gradiometer is based on a rotation of two fluxgate vector field sensors to enable frequency separation of the common mode from the gradient signals. Reposition of the gradiometer about three, nominally orthogonal axes, enables measurement of the full gradient tensor with one pair of fluxgate sensors. This paper describes a method to improve the accuracy of this type of gradiometer. System errors have been analyzed and classified according to the effect of the errors on the measurement accuracy. Major errors include scale factor error of the two fluxgates, misalignment and motion errors of these two sensors relative to the model system, and transformation errors when moving from the sensor to the instrument coordinate frame of reference. Minor errors include errors of finite length measurement parameters, errors associated with ignoring high-order tensors, the deviation of the rotation axis from ideal, and the temperature co-efficient of the fluxgates’ signals. We have developed the error models for the major errors and calibrated the full-tensor gradiometer by using the two independent tensor rotation invariants. 1000 simulations with random errors show the root mean squares of relative error are less than 8% after calibration. The calibration technique was applied to field trail measurements made using a gradiometer that was re-oriented multiple times around a fixed point while measuring a known gradient. Applying the calibration method resulted in an improvement of the tensor magnitude accuracy by a factor of 3.74. This result validated the calibration method.