DBDonald S. Burnett

Donald S. Burnett

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Donald S. Burnett has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Speeds and fluences of hydrogen and helium ejecta from the 2003 Halloween Solar Storm preserved by NASA Genesis samples

    by Azusa Tonotani, Ken‐Ichi Bajo, Naoya Sakamoto, Daniel B. Reisenfeld, Amy J. G. Jurewicz, Chad T. Olinger, Satoru Itose, Isao Sakaguchi, Morio Ishihara, Kiichiro Uchino, et al.

    The Halloween solar storms of 2003 and associated coronal mass ejections (CMEs) hurled one of the most intense interplanetary CMEs (ICMEs) during the space age toward Earth. The ICMEs forced many operating spacecraft into “safe mode” and spacecraft that were not “safed” were pushed to their observational limits. In contrast, although the electronics of the NASA Genesis spacecraft were safed, the solar wind (SW) collector array designed to sample CMEs remained deployed. The sample collection arrays were returned to Earth, enabling quantification of the hydrogen and helium particles of the ICMEs by depth profiling. During the entire period of collection by the Genesis spacecraft, the SW was monitored in situ continuously by the Advanced Composition Explorer (ACE). The Genesis results demonstrate that the hydrogen and helium fluences of ICMEs during the Halloween solar storms of 2003 were significantly greater than inferred by the in situ plasma instruments of ACE. In contrast, Genesis and ACE results were shown to be identical within uncertainties except for the period during the Halloween solar storms of 2003. The Genesis returned samples provide a means to investigate intense ICMEs in laboratories using Genesis data as a standard reference.

  • Open Access

    The solar system Fe/Mg ratio

    by D. S. Burnett, A. J. G. Jurewicz, D. S. Woolum, Y. Guan, V. S. Heber, R. Hervig, M. Humayun, K. D. McKeegan, L. R. Nittler, C. T. Olinger, et al.

    Solar wind Fe and Mg fluences (atoms/cm2) were measured from Genesis collectors. Fe and Mg have similar first ionization potentials and solar wind Fe/Mg should equal the solar ratio. Solar wind Fe/Mg is a more valid measure of solar composition than CI chondrites and can be measured more accurately than spectroscopic photospheric abundances. Mg and Fe fluences analyzed in four laboratories give satisfactory agreement. Si and diamond‐like carbon collector fluences agree for both elements. The Mg and Fe fluences are 1.731 ± 0.073 × 1012 and 1.366 ± 0.058 × 1012 atoms/cm2. All plausible sources of errors down to the 1% level are documented. Our value for the solar system Fe/Mg, 0.789 ± 0.048 agrees within 1 sigma errors with CI chondrites, spectroscopic photospheric abundances, and with the solar wind data from the ACE spacecraft. CI samples from asteroid Ryugu give Fe/Mg in agreement with Genesis and meteoritic CI samples despite very small sample sizes. The higher accuracy of the Genesis solar Fe/Mg permits a comparison with chondritic Fe/Mg at the 10% level. Intermeteorite Fe/Mg averages differ among the main C chondrite groups but are within, or very close to, the ±1 sigma Genesis solar Fe/Mg.


  • Elemental Abundances of Major Elements in the Solar Wind as Measured in Genesis Targets and Implications on Solar Wind Fractionation

    by Veronika S. Heber, Kevin D. McKeegan, Robert C. J. Steele, Amy J. G. Jurewicz, Karen D. Rieck, Yunbin Guan, Rainer Wieler, Donald S. Burnett

    We present elemental abundance data of C, N, O, Na, Mg, Al, Ca, and Cr in Genesis silicon targets. For Na, Mg, Al, and Ca, data from three different solar wind (SW) regimes are also presented. Data were obtained by backside depth profiling using secondary ion mass spectrometry. The accuracy of these measurements exceeds those obtained by in situ observations; therefore, the Genesis data provide new insights into elemental fractionation between Sun and SW, including differences between SW regimes. We integrate previously published noble gas and hydrogen elemental abundances from Genesis targets, as well as preliminary values for K and Fe. The abundances of the SW elements measured display the well-known fractionation pattern that correlates with each element’s first-ionization potential (FIP). When normalized either to spectroscopic photospheric solar abundances or to those derived from CI-chondritic meteorites, the fractionation factors of low-FIP elements (K, Na, Al, Ca, Cr, Mg, Fe) are essentially identical within uncertainties, but the data are equally consistent with increasing fractionation with decreasing FIP. The elements with higher FIPs between ∼11 and ∼16 eV (C, N, O, H, Ar, Kr, Xe) display a relatively well-defined trend of increasing fractionation with decreasing FIP, if normalized to modern 3D photospheric model abundances. Among the three Genesis regimes, the fast SW displays the least elemental fractionation for almost all elements (including the noble gases) but differences are modest: for low-FIP elements, the precisely measured fast–slow SW variations are less than 3%.


  • Open Access

    Quantifying low fluence ion implants in diamond-like carbon film by secondary ion mass spectrometry by understanding matrix effects

    by Amy J. G. Jurewicz, Chad T. Olinger, Donald S. Burnett, Yunbin Guan, Richard Hervig, Karen D. Rieck, Dorothy S. Woolum

    Minor and trace elements in diamond-like carbon (DLC) are difficult to quantify using SIMS analysis because minor elemental and structural variations can result in major matrix effects even across individual, cm-sized samples. While this material is most commonly used for tribological coatings where minor element composition is not of critical importance, it is being increasingly used in electronic devices. However, it is a unique application that spurred this work: anhydrous, tetrahedrally-coordinated DLC (ta-C) was used as a solar wind (SW) collector material in the Genesis solar-wind sample return mission (NASA Discovery 5). So, for ∼15 years, we have been working on attaining accurate and precise measurement of minor and trace elements in the Genesis DLC using SIMS to achieve our mission goals. Specifically, we have learned to deal with relevant matrix effects in our samples, ion implants into ta-C. Our unknown element for quantification is SW Mg, a low-dose (1.67 × 1012 at cm−2; ∼6 μg g−1 24Mg), low-energy (∼24 keV average energy) implant; our standard is a high-dose (∼1 × 1014 at cm−2 of both 25Mg, 26Mg) 75 keV laboratory implant for which the absolute 26Mg/25Mg ratio had been measured to account for variable instrumental mass fractionation. Analyses were performed using O2 + primary ions having both a low impact energy and a current density of ∼2 × 1014 ions per cm2. Although our unknown was solar wind, the method is applicable to many situations where minor elements in DLC need to be quantified. Recommendations are presented for modifying this data-reduction technique for other SIMS conditions.


  • Hydrogen fluence in Genesis collectors: Implications for acceleration of solar wind and for solar metallicity

    by Gary R. Huss, Elizabeth Koeman‐Shields, Amy J. G. Jurewicz, Donald S. Burnett, Kazuhide Nagashima, Ryan Ogliore, Chad T. Olinger

    NASA's Genesis mission was flown to capture samples of the solar wind and return them to the Earth for measurement. The purpose of the mission was to determine the chemical and isotopic composition of the Sun with significantly better precision than known before. Abundance data are now available for noble gases, magnesium, sodium, calcium, potassium, aluminum, chromium, iron, and other elements. Here, we report abundance data for hydrogen in four solar wind regimes collected by the Genesis mission (bulk solar wind, interstream low‐energy wind, coronal hole high‐energy wind, and coronal mass ejections). The mission was not designed to collect hydrogen, and in order to measure it, we had to overcome a variety of technical problems, as described herein. The relative hydrogen fluences among the four regimes should be accurate to better than ±5–6%, and the absolute fluences should be accurate to ±10%. We use the data to investigate elemental fractionations due to the first ionization potential during acceleration of the solar wind. We also use our data, combined with regime data for neon and argon, to estimate the solar neon and argon abundances, elements that cannot be measured spectroscopically in the solar photosphere.


  • Solar and Solar-Wind Composition Results from the Genesis Mission

    by R. C. Wiens, D. S. Burnett, C. M. Hohenberg, A. Meshik, V. Heber, A. Grimberg, R. Wieler, D. B. Reisenfeld


  • The Genesis Solar Wind Concentrator Target: Mass Fractionation Characterised by Neon Isotopes

    by V. S. Heber, R. C. Wiens, D. B. Reisenfeld, J. H. Allton, H. Baur, D. S. Burnett, C. T. Olinger, U. Wiechert, R. Wieler


  • Open Access

    igneous origin for the Na in the cloud of Io

    by Mary L. Johnson, D. S. Burnett

    We heated mixtures of sulfur and Na‐bearing silicates in evacuated silica glass capsules to temperatures between 600°C and 950°C. At or above 850°C, Na‐silicate glass reacts with elemental S to form a (Na,K) sulfide. Mobilization of this phase may account for the presence of Na and K on the surface of Io, and hence in the material sputtered into the Jovian magnetosphere.