Andranik Sarkissian
Andranik Sarkissian has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
- Luc Stafford
Université de Montréal
7 shared publications - Diego Mantovani
Laboratory for Biomaterials and Bioengineering, Canada Research Chair Tier I for the Innovation in Surgery, Department of Min-Met-Materials Engineering and Regenerative Medicine, CHU de Quebec Research Center, Laval University, Quebec City, QC, Canada
6 shared publications - Andreas Ruediger
Énergie Matériaux Télécommunications Research Centre Institut National De La Recherche Scientifique Varennes Quebec Canada
4 shared publications - Pascale Chevallier
Laval University
4 shared publications - L. Astrid Yáñez-Hernández
Laboratory for Biomaterials and Bioengineering (LBB), Canada Research Chair Tier I, Department of Min-Met-Materials Engineering & Regenerative Medicine, CHU de Quebec Research Center, Laval University, Quebec City, QC G1V 0A6, Canada
3 shared publications - Pierre Vinchon
R3 Institute of Newly-Emerging Science Design (INSD), The University of Osaka, Osaka 565-0871, Japan
3 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Wiley in Advanced Electronic Materials
- Vol. 12 (21)
Negative Feedback in Hf 0.5 Zr 0.5 O 2 Resistive Memory: Feigenbaum Route Toward Two‐Terminal Pseudo‐Random Number Generation and Neural Network Instabilities
Resistively switching metal‐insulator‐meal (MIM) structures are a strong contender for universal memory technologies and neuromorphic computing applications. Their ability to combine non‐volatility with analogue tuneability enables in‐memory computing, where both data processing and storage occur in the same physical location. A period‐doubling bifurcation was observed in endurance tests of TiN/ Hf 0.5 Zr 0.5 O 2 /Au devices, where sequences of voltage pulses with constant amplitudes are supplied to the stack. Based on this, the memory cell's response to increasingly larger voltage pulses is measured. The extracted parameters are used to deduce a probabilistic non‐linear map describing endurance cycling of the MIM system. The investigation of the dynamics involves the identification of parameters that have been reported to be subject to change during continuous switching, and the investigation of how this drift affects the switching dynamics. The found model thus serves as a design framework to either deliberately develop systems exhibiting chaotic dynamics or circumvent them for classical memory applications.
- 2 November 2026
- Published by Wiley in Advanced Electronic Materials
- Vol. 12 (21)
Open AccessNegative Feedback in Hf 0.5 Zr 0.5 O 2 Resistive Memory: Feigenbaum Route Toward Two‐Terminal Pseudo‐Random Number Generation and Neural Network Instabilities
Resistively switching metal‐insulator‐meal (MIM) structures are a strong contender for universal memory technologies and neuromorphic computing applications. Their ability to combine non‐volatility with analogue tuneability enables in‐memory computing, where both data processing and storage occur in the same physical location. A period‐doubling bifurcation was observed in endurance tests of TiN/ Hf 0.5 Zr 0.5 O 2 /Au devices, where sequences of voltage pulses with constant amplitudes are supplied to the stack. Based on this, the memory cell's response to increasingly larger voltage pulses is measured. The extracted parameters are used to deduce a probabilistic non‐linear map describing endurance cycling of the MIM system. The investigation of the dynamics involves the identification of parameters that have been reported to be subject to change during continuous switching, and the investigation of how this drift affects the switching dynamics. The found model thus serves as a design framework to either deliberately develop systems exhibiting chaotic dynamics or circumvent them for classical memory applications.
- Open Access
- 18 February 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 32
On the adhesion of a-C:H coatings deposited by PECVD on PDMS for biomedical applications
- 18 February 2026
- Published by Elsevier in Applied Surface Science Advances
- Vol. 32
Open AccessOn the adhesion of a-C:H coatings deposited by PECVD on PDMS for biomedical applications
- Open Access
- 16 February 2026
- Published by Elsevier in SSRN Electronic Journal
Negative feedback in Hf0.5Zr0.5O2 resistive memory: Feigenbaum route towards two-terminal pseudo-random number generation and neural network instabilities
Resistively switching metal-insulator-meal structures are a strong contender for universal memory technologies and neuromorphic computing applications. Their ability to combine non-volatility with analogue tuneability enables in-memory computing, where both data processing and storage occur in the same physical location. Period-doubling bifurcations have been observed in endurance tests of TiN/ Hf0.5Zr0.5O2/Au devices, where sequences of voltage pulses with constant amplitudes are supplied to the stack. Based on this, the memory cell’s response to increasingly larger voltage pulses was measured to deduce a non-linear map describing the system. A phenomenological description of the system was found using a lognormal-style function which is then analysed further, regarding it’s maximum Lyapunov exponents and a Feigenbaum diagram under a multiplicative control parameter. Furthermore, the negative feedback characteristic observed in the nonlinear map is physically interpreted as arising from Joule heating, where electrical energy dissipation within the resistive element modulates its conductive state.
- 16 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNegative feedback in Hf0.5Zr0.5O2 resistive memory: Feigenbaum route towards two-terminal pseudo-random number generation and neural network instabilities
Resistively switching metal-insulator-meal structures are a strong contender for universal memory technologies and neuromorphic computing applications. Their ability to combine non-volatility with analogue tuneability enables in-memory computing, where both data processing and storage occur in the same physical location. Period-doubling bifurcations have been observed in endurance tests of TiN/ Hf0.5Zr0.5O2/Au devices, where sequences of voltage pulses with constant amplitudes are supplied to the stack. Based on this, the memory cell’s response to increasingly larger voltage pulses was measured to deduce a non-linear map describing the system. A phenomenological description of the system was found using a lognormal-style function which is then analysed further, regarding it’s maximum Lyapunov exponents and a Feigenbaum diagram under a multiplicative control parameter. Furthermore, the negative feedback characteristic observed in the nonlinear map is physically interpreted as arising from Joule heating, where electrical energy dissipation within the resistive element modulates its conductive state.
- Open Access
- 11 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 9968
Plasma-Based Amorphous Carbon Coatings on Polymeric Substrates for Biomedical Applications: A Critical Review Focused on Adhesion
Material surfaces are of primary importance in biomaterial development, significantly influencing implant lifespan and clinical success. Consequently, coating technologies are frequently employed to modify surface properties and functionality. Plasma-based amorphous carbon coatings have been widely applied to all classes of substrates to improve their tribology, corrosion resistance, hardness, and even biological properties. Plasma technology is widely recognized to be effective, not only for the deposition of amorphous carbon coatings but also for substrate pre-treatment, in which it may play a key role in activating surfaces and enhancing interfacial adhesion. Amorphous carbon coatings can be classified into two major categories: diamond-like carbon (DLC) and polymer-like carbon (PLC), according to their mechanical properties. Regardless of their nature, the adhesion of both types of amorphous carbon coatings to the substrate has always represented a major challenge. Several strategies have been reported to enhance the adhesion of DLC coatings to silicon wafers, metals, and glass substrates. However, few studies report strategies aimed at controlling the adhesion of (both types of) amorphous carbon coatings to polymeric substrates, polymeric implants, and polymeric devices. Therefore, this work aims to provide a state-of-the-art review on the adhesion of amorphous carbon coatings to polymeric substrates for biomedical applications. Furthermore, this review presents the main techniques used to assess adhesion and the strategies available to improve adhesion between coatings and polymeric substrates.
- 11 September 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (18) , 9968
Open AccessPlasma-Based Amorphous Carbon Coatings on Polymeric Substrates for Biomedical Applications: A Critical Review Focused on Adhesion
Material surfaces are of primary importance in biomaterial development, significantly influencing implant lifespan and clinical success. Consequently, coating technologies are frequently employed to modify surface properties and functionality. Plasma-based amorphous carbon coatings have been widely applied to all classes of substrates to improve their tribology, corrosion resistance, hardness, and even biological properties. Plasma technology is widely recognized to be effective, not only for the deposition of amorphous carbon coatings but also for substrate pre-treatment, in which it may play a key role in activating surfaces and enhancing interfacial adhesion. Amorphous carbon coatings can be classified into two major categories: diamond-like carbon (DLC) and polymer-like carbon (PLC), according to their mechanical properties. Regardless of their nature, the adhesion of both types of amorphous carbon coatings to the substrate has always represented a major challenge. Several strategies have been reported to enhance the adhesion of DLC coatings to silicon wafers, metals, and glass substrates. However, few studies report strategies aimed at controlling the adhesion of (both types of) amorphous carbon coatings to polymeric substrates, polymeric implants, and polymeric devices. Therefore, this work aims to provide a state-of-the-art review on the adhesion of amorphous carbon coatings to polymeric substrates for biomedical applications. Furthermore, this review presents the main techniques used to assess adhesion and the strategies available to improve adhesion between coatings and polymeric substrates.
- 28 August 2025
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 348
Enhancing hemocompatibility of titanium alloys through plasma immersion ion implantation
- 28 August 2025
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 348
Enhancing hemocompatibility of titanium alloys through plasma immersion ion implantation
- Open Access
- 5 November 2024
- Published by Elsevier in Materialia
- Vol. 38
Effects of plasma surface modification of Mg-2Y-2Zn-1Mn for biomedical applications
- 5 November 2024
- Published by Elsevier in Materialia
- Vol. 38
Open AccessEffects of plasma surface modification of Mg-2Y-2Zn-1Mn for biomedical applications
- Open Access
- 23 April 2024
- Published by Open Exploration Publishing
- Vol. 1 (2) , 84-99
Effects of cold plasma treatment on the biological performances of decellularized bovine pericardium extracellular matrix-based films for biomedical applications
Aim: Since decades, decellularized extracellular matrix (dECM)-derived materials have received worldwide attention as promising biomaterials for tissue engineering and biomedical applications. Soluble dECM is a versatile raw material that can be easily engineered into the desired shapes and structures. However, there are still some limitations restricting its use, including low hydrophilicity and smooth surfaces, which negatively influence cell adhesion/spreading. The objective of the present study was to investigate surface modification by nitrogen/hydrogen (N2/H2) low-pressure cold plasma treatment as a potential technique to improve the biological response of bovine pericardium dECM films. Methods: Bovine pericardium dECM was enzymatically digested and lyophilized prior to the preparation of thin films via solvent-casting method. Changes in surface properties after plasma treatment were investigated using water contact angle (WCA) and X-ray photoelectron spectroscopy (XPS) measurements. Immunofluorescence staining and resazurin assay for human dermal fibroblasts (HDFs) cultured on the dECM films were used to assess the bioactivity of dECM films. Finally, the hemocompatibility of the films was investigated via clotting time and hemolysis assay. Results: WCA and XPS results revealed that oxygen (O)- and N-containing functional groups were incorporated onto the film surface and an increase in hydrophilicity was observed after plasma treatment. In vitro experiments showed that cell adhesion in plasma-treated dECM films is much faster if compared to the untreated controls. Moreover, the fibroblast proliferation increased after plasma surface modifications. Finally, the hemocompatibility analysis results indicated a delayed blood clotting and no hemolytic effects for all the tested samples. Conclusions: These findings confirmed the potential of dECM as raw material for biocompatible thin films fabrication. Additionally, plasma surface treatment emerged as an eco-friendly and cost-effective strategy to enhance in vitro cell attachment and proliferation on dECM films, expanding their applications in biomedicine.
- 23 April 2024
- Published by Open Exploration Publishing
- Vol. 1 (2) , 84-99
Open AccessEffects of cold plasma treatment on the biological performances of decellularized bovine pericardium extracellular matrix-based films for biomedical applications
Aim: Since decades, decellularized extracellular matrix (dECM)-derived materials have received worldwide attention as promising biomaterials for tissue engineering and biomedical applications. Soluble dECM is a versatile raw material that can be easily engineered into the desired shapes and structures. However, there are still some limitations restricting its use, including low hydrophilicity and smooth surfaces, which negatively influence cell adhesion/spreading. The objective of the present study was to investigate surface modification by nitrogen/hydrogen (N2/H2) low-pressure cold plasma treatment as a potential technique to improve the biological response of bovine pericardium dECM films. Methods: Bovine pericardium dECM was enzymatically digested and lyophilized prior to the preparation of thin films via solvent-casting method. Changes in surface properties after plasma treatment were investigated using water contact angle (WCA) and X-ray photoelectron spectroscopy (XPS) measurements. Immunofluorescence staining and resazurin assay for human dermal fibroblasts (HDFs) cultured on the dECM films were used to assess the bioactivity of dECM films. Finally, the hemocompatibility of the films was investigated via clotting time and hemolysis assay. Results: WCA and XPS results revealed that oxygen (O)- and N-containing functional groups were incorporated onto the film surface and an increase in hydrophilicity was observed after plasma treatment. In vitro experiments showed that cell adhesion in plasma-treated dECM films is much faster if compared to the untreated controls. Moreover, the fibroblast proliferation increased after plasma surface modifications. Finally, the hemocompatibility analysis results indicated a delayed blood clotting and no hemolytic effects for all the tested samples. Conclusions: These findings confirmed the potential of dECM as raw material for biocompatible thin films fabrication. Additionally, plasma surface treatment emerged as an eco-friendly and cost-effective strategy to enhance in vitro cell attachment and proliferation on dECM films, expanding their applications in biomedicine.
- Open Access
- 29 March 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (7) , 609
Fluorocarbon Plasma-Polymerized Layer Increases the Release Time of Silver Ions and the Antibacterial Activity of Silver-Based Coatings
Silver-based antibacterial coatings limit the spread of hospital-acquired infections. Indeed, the use of silver and silver oxide nanoparticles (Ag and AgO NPs) incorporated in amorphous hydrogenated carbon (a-C:H) as a matrix demonstrates a promising approach to reduce microbial contamination on environmental surfaces. However, its success as an antibacterial coating hinges on the control of Ag+ release. In this sense, if a continuous release is required, an additional barrier is needed to extend the release time of Ag+. Thus, this research investigated the use of a plasma fluoropolymer (CFx) as an additional top layer to elongate Ag+ release and increase the antibacterial activity due to its high hydrophobic nature. Herein, a porous CFx film was deposited on a-C:H containing Ag and AgO NPs using pulsed afterglow low pressure plasma polymerization. The chemical composition, surface wettability and morphology, release profile, and antibacterial activity were analyzed. Overall, the combination of a-C:H:Ag (12.1 at. % of Ag) and CFx film (120.0°, F/C = 0.8) successfully inactivated 88% of E. coli and delayed biofilm formation after 12 h. Thus, using a hybrid approach composed of Ag NPs and a hydrophobic polymeric layer, it was possible to increase the overall antibacterial activity of the coating.
- 29 March 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (7) , 609
Open AccessFluorocarbon Plasma-Polymerized Layer Increases the Release Time of Silver Ions and the Antibacterial Activity of Silver-Based Coatings
Silver-based antibacterial coatings limit the spread of hospital-acquired infections. Indeed, the use of silver and silver oxide nanoparticles (Ag and AgO NPs) incorporated in amorphous hydrogenated carbon (a-C:H) as a matrix demonstrates a promising approach to reduce microbial contamination on environmental surfaces. However, its success as an antibacterial coating hinges on the control of Ag+ release. In this sense, if a continuous release is required, an additional barrier is needed to extend the release time of Ag+. Thus, this research investigated the use of a plasma fluoropolymer (CFx) as an additional top layer to elongate Ag+ release and increase the antibacterial activity due to its high hydrophobic nature. Herein, a porous CFx film was deposited on a-C:H containing Ag and AgO NPs using pulsed afterglow low pressure plasma polymerization. The chemical composition, surface wettability and morphology, release profile, and antibacterial activity were analyzed. Overall, the combination of a-C:H:Ag (12.1 at. % of Ag) and CFx film (120.0°, F/C = 0.8) successfully inactivated 88% of E. coli and delayed biofilm formation after 12 h. Thus, using a hybrid approach composed of Ag NPs and a hydrophobic polymeric layer, it was possible to increase the overall antibacterial activity of the coating.
- Open Access
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
In-plasma analysis of plasma–surface interactions
During deposition, modification, and etching of thin films and nanomaterials in reactive plasmas, many active species can interact with the sample simultaneously. This includes reactive neutrals formed by fragmentation of the feed gas, positive ions, and electrons generated by electron-impact ionization of the feed gas and fragments, excited states (in particular, long-lived metastable species), and photons produced by spontaneous de-excitation of excited atoms and molecules. Notably, some of these species can be transiently present during the different phases of plasma processing, such as etching of thin layer deposition. To monitor plasma–surface interactions during materials processing, a new system combining beams of neutral atoms, positive ions, UV photons, and a magnetron plasma source has been developed. This system is equipped with a unique ensemble of in-plasma surface characterization tools, including (1) a Rutherford Backscattering Spectrometer (RBS), (2) an Elastic Recoil Detector (ERD), and (3) a Raman spectroscopy system. RBS and ERD analyses are carried out using a differentially pumped 1.7 MV ion beam line Tandetron accelerator generating a beam at grazing incidence. The ERD system is equipped with an absorber and is specifically used to detect H initially bonded to the surface; higher resolution of surface H is also available through nuclear reaction analysis. In parallel, an optical port facing the substrate is used to perform Raman spectroscopy analysis of the samples during plasma processing. This system enables fast monitoring of a few Raman peaks over nine points scattered on a 1.6 × 1.6 mm2 surface without interference from the inherent light emitted by the plasma. Coupled to the various plasma and beam sources, the unique set of in-plasma surface characterization tools detailed in this study can provide unique time-resolved information on the modification induced by plasma. By using the ion beam analysis capability, the atomic concentrations of various elements in the near-surface (e.g., stoichiometry and impurity content) can be monitored in real-time during plasma deposition or etching. On the other hand, the evolution of Raman peaks as a function of plasma processing time can contribute to a better understanding of the role of low-energy ions in defect generation in irradiation-sensitive materials, such as monolayer graphene.
- 1 August 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (8)
Open AccessIn-plasma analysis of plasma–surface interactions
During deposition, modification, and etching of thin films and nanomaterials in reactive plasmas, many active species can interact with the sample simultaneously. This includes reactive neutrals formed by fragmentation of the feed gas, positive ions, and electrons generated by electron-impact ionization of the feed gas and fragments, excited states (in particular, long-lived metastable species), and photons produced by spontaneous de-excitation of excited atoms and molecules. Notably, some of these species can be transiently present during the different phases of plasma processing, such as etching of thin layer deposition. To monitor plasma–surface interactions during materials processing, a new system combining beams of neutral atoms, positive ions, UV photons, and a magnetron plasma source has been developed. This system is equipped with a unique ensemble of in-plasma surface characterization tools, including (1) a Rutherford Backscattering Spectrometer (RBS), (2) an Elastic Recoil Detector (ERD), and (3) a Raman spectroscopy system. RBS and ERD analyses are carried out using a differentially pumped 1.7 MV ion beam line Tandetron accelerator generating a beam at grazing incidence. The ERD system is equipped with an absorber and is specifically used to detect H initially bonded to the surface; higher resolution of surface H is also available through nuclear reaction analysis. In parallel, an optical port facing the substrate is used to perform Raman spectroscopy analysis of the samples during plasma processing. This system enables fast monitoring of a few Raman peaks over nine points scattered on a 1.6 × 1.6 mm2 surface without interference from the inherent light emitted by the plasma. Coupled to the various plasma and beam sources, the unique set of in-plasma surface characterization tools detailed in this study can provide unique time-resolved information on the modification induced by plasma. By using the ion beam analysis capability, the atomic concentrations of various elements in the near-surface (e.g., stoichiometry and impurity content) can be monitored in real-time during plasma deposition or etching. On the other hand, the evolution of Raman peaks as a function of plasma processing time can contribute to a better understanding of the role of low-energy ions in defect generation in irradiation-sensitive materials, such as monolayer graphene.
- 24 July 2023
- Published by Springer Nature in Cellulose
- Vol. 30 (12) , 7889-7904
Permeation properties of a plasma-processed organosilicon–carboxymethylcellulose bilayer on fibrillated cellulosic films for sustainable packaging applications
- 24 July 2023
- Published by Springer Nature in Cellulose
- Vol. 30 (12) , 7889-7904
Permeation properties of a plasma-processed organosilicon–carboxymethylcellulose bilayer on fibrillated cellulosic films for sustainable packaging applications