Jozef Cebulski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jozef Cebulski has a total of 324 co-authors. Here are the top co-authors by number of shared publications:
- Eugeniusz M. Sheregii
Faculty of Mathematics and Natural Sciences, University of Rzeszow, Rzeszow, Poland
32 shared publications - Jacek Polit
Centre for Microelectronics and Nanotechnology, University of Rzeszow, S. Pigonia 1, 35-959 Rzeszow, Poland
25 shared publications - Joanna Depciuch
Institute of Nuclear Physics, Polish Academy of Sciences, Walerego Eljasza - Radzikowskiego 152, 31-342 Kraków, Poland
19 shared publications - Augusto Marcelli
INFN-Laboratori Nazionali di Frascati, Frascati, Italy
18 shared publications - Kornelia Łach
Department of Medical Chemistry and Metabolomics, Faculty of Medicine, Medical College, University of Rzeszow, al. T. Rejtana 16c, 35-959 Rzeszów, Poland
14 shared publications - Oleh Shpotyuk
Faculty of Science and Technology, Jan Dlugosz University in Czestochowa, Czestochowa, Poland
13 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by LUKASIEWICZ Research Network - Industrial Chemistry Research Institute in Polimery
- Vol. 71 (9) , 583-591
Polymer materials used in optometry and ophthalmology – an overview. Part II. Aging processes of polymeric lensess made of
Polymeric materials play a crucial role in modern ophthalmology and optometry and are widely used in contact lenses, intraocular lenses, and implants designed to replace damaged ocular tissues. Owing to their high optical transparency, biocompatibility, and tunable physicochemical properties, polymers have become the basis of numerous advanced medical devices for vision correction and ocular treatment. Although these materials are not subject to the biological aging processes characteristic of the natural crystalline lens, they may undergo structural and surface changes during long-term use as a result of exposure to ultraviolet radiation, oxidative stress, temperature fluctuations, and the ocular environment. These processes can affect the optical, mechanical, and functional properties of ophthalmic devices. This review presents current literature on the aging mechanisms of polymeric materials used in ophthalmic lenses, with particular emphasis on degradation factors, structural changes occurring within the materials, and their impact on durability, performance, and safety. The article is a continuation of a previous review devoted to the applications of polymeric materials in ophthalmology and optometry.
- 16 October 2026
- Published by LUKASIEWICZ Research Network - Industrial Chemistry Research Institute in Polimery
- Vol. 71 (9) , 583-591
Open AccessPolymer materials used in optometry and ophthalmology – an overview. Part II. Aging processes of polymeric lensess made of
Polymeric materials play a crucial role in modern ophthalmology and optometry and are widely used in contact lenses, intraocular lenses, and implants designed to replace damaged ocular tissues. Owing to their high optical transparency, biocompatibility, and tunable physicochemical properties, polymers have become the basis of numerous advanced medical devices for vision correction and ocular treatment. Although these materials are not subject to the biological aging processes characteristic of the natural crystalline lens, they may undergo structural and surface changes during long-term use as a result of exposure to ultraviolet radiation, oxidative stress, temperature fluctuations, and the ocular environment. These processes can affect the optical, mechanical, and functional properties of ophthalmic devices. This review presents current literature on the aging mechanisms of polymeric materials used in ophthalmic lenses, with particular emphasis on degradation factors, structural changes occurring within the materials, and their impact on durability, performance, and safety. The article is a continuation of a previous review devoted to the applications of polymeric materials in ophthalmology and optometry.
- 17 September 2026
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 370
Identifying medium-range structure response on cation- and anion-substitution modification effects in glassy arsenoselenides
- 17 September 2026
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 370
Identifying medium-range structure response on cation- and anion-substitution modification effects in glassy arsenoselenides
- Open Access
Visibility-Graph Analysis of Raman Spectra in Chalazion and Lipid Dysregulation: An Exploratory Study
A chalazion is an inflammatory lesion of the eyelid caused by a blockage in the sebaceous glands. To identify subtle biochemical differences in chalazion secretions and patient serum, we apply a graph-theory-based visibility-graph approach to Raman spectra, focusing on its exploratory potential for detecting band-specific spectral differences. As a classical baseline, we also employ Principal Component Analysis (PCA); however, the visibility-graph approach provides complementary, band-localized information that may support interpretation of subtle spectral differences. The study included samples from chalazion patients and control subjects, comprising healthy individuals and patients with lipid disorders. Raman spectra were analyzed by transforming the data into visibility graphs, enabling identification of hidden correlations and signal dynamics. Within the VG representation, group differences were concentrated mainly in the 1100–1300 cm−1 range, with localized extrema near 1177, 1184, and 1260 cm−1 in chalazion secretions and near 1172, 1174, 1219, and 1257 cm−1 in serum. The identified positions overlap regions with possible lipid- and protein-related contributions, including C–C, =CH, and amide III vibrations, and are treated as candidate spectral positions rather than markers of individual molecular compounds. From the perspective of complex-network-based signal analysis, the visibility-graph transformation provides an alternative way of representing Raman spectra and extracting structural information that is not readily apparent in the original spectral domain. This information-oriented approach is consistent with entropy-related studies of complex signals, where nonlinear structure, local organization, and hidden dependencies in data are of central interest. These findings suggest that visibility-graph analysis may be useful as an exploratory tool for identifying candidate lipid-related spectral features, although further validation using larger sample sets is required. Full-range PCA was also examined over 200–2000 cm−1. It revealed global covariance patterns distributed across several spectral regions, whereas VG localized the pairwise differences within the 1100–1300 cm−1 range at specific Raman-shift positions.
Open AccessVisibility-Graph Analysis of Raman Spectra in Chalazion and Lipid Dysregulation: An Exploratory Study
A chalazion is an inflammatory lesion of the eyelid caused by a blockage in the sebaceous glands. To identify subtle biochemical differences in chalazion secretions and patient serum, we apply a graph-theory-based visibility-graph approach to Raman spectra, focusing on its exploratory potential for detecting band-specific spectral differences. As a classical baseline, we also employ Principal Component Analysis (PCA); however, the visibility-graph approach provides complementary, band-localized information that may support interpretation of subtle spectral differences. The study included samples from chalazion patients and control subjects, comprising healthy individuals and patients with lipid disorders. Raman spectra were analyzed by transforming the data into visibility graphs, enabling identification of hidden correlations and signal dynamics. Within the VG representation, group differences were concentrated mainly in the 1100–1300 cm−1 range, with localized extrema near 1177, 1184, and 1260 cm−1 in chalazion secretions and near 1172, 1174, 1219, and 1257 cm−1 in serum. The identified positions overlap regions with possible lipid- and protein-related contributions, including C–C, =CH, and amide III vibrations, and are treated as candidate spectral positions rather than markers of individual molecular compounds. From the perspective of complex-network-based signal analysis, the visibility-graph transformation provides an alternative way of representing Raman spectra and extracting structural information that is not readily apparent in the original spectral domain. This information-oriented approach is consistent with entropy-related studies of complex signals, where nonlinear structure, local organization, and hidden dependencies in data are of central interest. These findings suggest that visibility-graph analysis may be useful as an exploratory tool for identifying candidate lipid-related spectral features, although further validation using larger sample sets is required. Full-range PCA was also examined over 200–2000 cm−1. It revealed global covariance patterns distributed across several spectral regions, whereas VG localized the pairwise differences within the 1100–1300 cm−1 range at specific Raman-shift positions.
- Open Access
- 5 August 2026
- Published by LUKASIEWICZ Research Network - Industrial Chemistry Research Institute in Polimery
- Vol. 71 (7-8) , 475-484
Polymer materials used in optometry and ophthalmology ‒ an overview. Part I. Types of polymers and applications
Polymers play a pivotal role in modern optometry and ophthalmology, driving major advances in the development of spectacle lenses, contact lenses, intraocular lenses, and diagnostic devices. Their widespread use is attributed to a unique combination of properties, including high optical transparency, low weight, mechanical durability, and the potential for biological and surface modifications. Continuous progress in polymer science and engineering has significantly enhanced the performance, safety, and functionality of ophthalmic products, particularly contact lenses. The selection of appropriate polymeric material is crucial, as it directly influences wearer comfort, corneal health, oxygen permeability, wettability, and overall visual performance. This review provides a comprehensive overview of the polymeric materials most employed in optometric and ophthalmic applications. Their physicochemical properties, functional characteristics, and clinical significance are discussed, emphasizing their fundamental role in contemporary eye care and their potential to support future innovations in ophthalmic materials and technologies.
- 5 August 2026
- Published by LUKASIEWICZ Research Network - Industrial Chemistry Research Institute in Polimery
- Vol. 71 (7-8) , 475-484
Open AccessPolymer materials used in optometry and ophthalmology ‒ an overview. Part I. Types of polymers and applications
Polymers play a pivotal role in modern optometry and ophthalmology, driving major advances in the development of spectacle lenses, contact lenses, intraocular lenses, and diagnostic devices. Their widespread use is attributed to a unique combination of properties, including high optical transparency, low weight, mechanical durability, and the potential for biological and surface modifications. Continuous progress in polymer science and engineering has significantly enhanced the performance, safety, and functionality of ophthalmic products, particularly contact lenses. The selection of appropriate polymeric material is crucial, as it directly influences wearer comfort, corneal health, oxygen permeability, wettability, and overall visual performance. This review provides a comprehensive overview of the polymeric materials most employed in optometric and ophthalmic applications. Their physicochemical properties, functional characteristics, and clinical significance are discussed, emphasizing their fundamental role in contemporary eye care and their potential to support future innovations in ophthalmic materials and technologies.
- Open Access
Serum Fourier-Transform Infrared Spectroscopy with Machine Learning for Screening of Pediatric Acute Lymphoblastic Leukemia: A Proof-of-Concept Study
Background: Acute lymphoblastic leukemia (ALL) is the most common childhood malignancy, yet diagnosis still relies primarily on invasive bone-marrow procedures and advanced laboratory assays. Non-invasive, rapid, and cost-effective tools remain an unmet need. Fourier-transform infrared (FTIR) spectroscopy has shown promise for detecting cancer-associated biochemical changes in biofluids and cells. Methods: Serum from pediatric ALL patients and controls (n = 103; ALL = 45, controls = 58: healthy = 14, hematology controls = 44 with anemia, thrombocytopenia, leukopenia, and pancytopenia) was analyzed using FTIR. Spectra (800–1800, 2800–3500 cm−1) were preprocessed with baseline correction, derivative filtering, and normalization. Group differences were assessed statistically, and logistic regression with stratified 10-fold cross-validation was applied; Receiver operating characteristic (ROC)\precision–recall (PR) analyses were based on out-of-fold predictions. Results: Distinct spectral alterations were observed between ALL and controls. Leukemia samples showed higher amide I (~1640 cm−1) and amide II (~1545 cm−1) absorbance, lower lipid-related bands (~1450, ~2920 cm−1), and increased nucleic-acid–associated signals (~1080 cm−1). Differences were significant (q < 0.05) with moderate effect sizes. Logistic regression achieved area under the curve (AUC) ≈ 0.80 with sensitivity ~0.73–0.84 across practical decision thresholds (0.50 → 0.30) and higher recall attainable at the expense of specificity. Principal component analysis (PCA)\hierarchical cluster analysis (HCA) indicated partial but consistent group separation, aligning with supervised performance. Conclusions: Serum FTIR spectroscopy shows promise for distinguishing pediatric ALL from controls by reflecting disease-related metabolic changes. The technique is rapid, label-free, and requires only small serum volumes. Our findings represent proof-of-concept, and validation in larger, multi-center studies is needed before clinical implementation can be considered.
Open AccessSerum Fourier-Transform Infrared Spectroscopy with Machine Learning for Screening of Pediatric Acute Lymphoblastic Leukemia: A Proof-of-Concept Study
Background: Acute lymphoblastic leukemia (ALL) is the most common childhood malignancy, yet diagnosis still relies primarily on invasive bone-marrow procedures and advanced laboratory assays. Non-invasive, rapid, and cost-effective tools remain an unmet need. Fourier-transform infrared (FTIR) spectroscopy has shown promise for detecting cancer-associated biochemical changes in biofluids and cells. Methods: Serum from pediatric ALL patients and controls (n = 103; ALL = 45, controls = 58: healthy = 14, hematology controls = 44 with anemia, thrombocytopenia, leukopenia, and pancytopenia) was analyzed using FTIR. Spectra (800–1800, 2800–3500 cm−1) were preprocessed with baseline correction, derivative filtering, and normalization. Group differences were assessed statistically, and logistic regression with stratified 10-fold cross-validation was applied; Receiver operating characteristic (ROC)\precision–recall (PR) analyses were based on out-of-fold predictions. Results: Distinct spectral alterations were observed between ALL and controls. Leukemia samples showed higher amide I (~1640 cm−1) and amide II (~1545 cm−1) absorbance, lower lipid-related bands (~1450, ~2920 cm−1), and increased nucleic-acid–associated signals (~1080 cm−1). Differences were significant (q < 0.05) with moderate effect sizes. Logistic regression achieved area under the curve (AUC) ≈ 0.80 with sensitivity ~0.73–0.84 across practical decision thresholds (0.50 → 0.30) and higher recall attainable at the expense of specificity. Principal component analysis (PCA)\hierarchical cluster analysis (HCA) indicated partial but consistent group separation, aligning with supervised performance. Conclusions: Serum FTIR spectroscopy shows promise for distinguishing pediatric ALL from controls by reflecting disease-related metabolic changes. The technique is rapid, label-free, and requires only small serum volumes. Our findings represent proof-of-concept, and validation in larger, multi-center studies is needed before clinical implementation can be considered.
- 4 March 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (5) , e202400550
Investigating the Impact of Long‐Term Alcohol Consumption on Serum Chemical Changes: Fourier Transform Infrared Spectroscopy for Human Blood Serum
Chronic alcohol consumption significantly impacts physiological and neurological functions. This study aimed to investigate the biochemical alterations in serum associated with long‐term alcohol use using Fourier Transform Infrared (FTIR) spectroscopy. Serum samples from control and alcohol use disorder (AUD) were analyzed, and their spectra were compared. Multivariate analysis techniques, including Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA), were employed to differentiate the groups. A machine learning model, Grid Search‐Support Vector Machine Discriminant Analysis (GS‐SVMDA), was developed to classify samples with high accuracy. Significant differences in the absorbance values of specific functional groups, particularly those associated with phospholipids, amides, and fatty acids revealed. The AUD exhibited lower levels of these biomolecules. The models achieved perfect classification, demonstrating the potential ofFTIR spectroscopy as a non‐invasive tool for diagnosing AUD. Findings contribute to a better understanding of the biochemical mechanisms underlying alcohol addiction and may aid in the development of novel diagnostic and therapeutic strategies.
- 4 March 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 18 (5) , e202400550
Investigating the Impact of Long‐Term Alcohol Consumption on Serum Chemical Changes: Fourier Transform Infrared Spectroscopy for Human Blood Serum
Chronic alcohol consumption significantly impacts physiological and neurological functions. This study aimed to investigate the biochemical alterations in serum associated with long‐term alcohol use using Fourier Transform Infrared (FTIR) spectroscopy. Serum samples from control and alcohol use disorder (AUD) were analyzed, and their spectra were compared. Multivariate analysis techniques, including Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA), were employed to differentiate the groups. A machine learning model, Grid Search‐Support Vector Machine Discriminant Analysis (GS‐SVMDA), was developed to classify samples with high accuracy. Significant differences in the absorbance values of specific functional groups, particularly those associated with phospholipids, amides, and fatty acids revealed. The AUD exhibited lower levels of these biomolecules. The models achieved perfect classification, demonstrating the potential ofFTIR spectroscopy as a non‐invasive tool for diagnosing AUD. Findings contribute to a better understanding of the biochemical mechanisms underlying alcohol addiction and may aid in the development of novel diagnostic and therapeutic strategies.
- 4 December 2024
- Published by Springer Nature
- p. 65-78
Comparative PALS-Tracking of Photopolymerization Volumetric Shrinkage in Polymer-Filler Dental Restorative Nanocomposites
- 4 December 2024
- Published by Springer Nature
- p. 65-78
Comparative PALS-Tracking of Photopolymerization Volumetric Shrinkage in Polymer-Filler Dental Restorative Nanocomposites
- 7 June 2024
- Published by Springer Nature in Cell Biochemistry and Biophysics
- Vol. 82 (3) , 2989-2999
Raman Spectroscopy of Blood Serum for Essential Thrombocythemia Diagnosis: Correlation with Genetic Mutations and Optimization of Laser Wavelengths
Essential thrombocythemia (ET) is a type of myeloproliferative neoplasm that increases the risk of thrombosis. To diagnose this disease, the analysis of mutations in the Janus Kinase 2 (JAK2), thrombopoietin receptor (MPL), or calreticulin (CALR) gene is recommended. Disease poses diagnostic challenges due to overlapping mutations with other neoplasms and the presence of triple-negative cases. This study explores the potential of Raman spectroscopy combined with machine learning for ET diagnosis. We assessed two laser wavelengths (785, 1064 nm) to differentiate between ET patients and healthy controls. The PCR results indicate that approximately 50% of patients in our group have a mutation in the JAK2 gene, while only 5% of patients harbor a mutation in the ASXL1 gene. Additionally, only one patient had a mutation in the IDH1 and one had a mutation in IDH2 gene. Consequently, patients having no mutations were also observed in our group, making diagnosis challenging. Raman spectra at 1064 nm showed lower amide, polysaccharide, and lipid vibrations in ET patients, while 785 nm spectra indicated significant decreases in amide II and C-H lipid vibrations. Principal Component Analysis (PCA) confirmed that both wavelengths could distinguish ET from healthy subjects. Support Vector Machine (SVM) analysis revealed that the 800–1800 cm−1 range provided the highest diagnostic accuracy, with 89% for 785 nm and 72% for 1064 nm. These findings suggest that FT-Raman spectroscopy, paired with multivariate and machine learning analyses, offers a promising method for diagnosing ET with high accuracy by detecting specific molecular changes in serum. Principal Component Analysis (PCA) confirmed that both wavelengths could distinguish ET from healthy subjects. Support Vector Machine (SVM) analysis revealed that the 800–1800 cm−1 range provided the highest diagnostic accuracy, with 89% for 785 nm and 72% for 1064 nm. These findings suggest that FT-Raman spectroscopy, paired with multivariate and machine learning analyses, offers a promising method for diagnosing ET with high accuracy by detecting specific molecular changes in serum.
- 7 June 2024
- Published by Springer Nature in Cell Biochemistry and Biophysics
- Vol. 82 (3) , 2989-2999
Raman Spectroscopy of Blood Serum for Essential Thrombocythemia Diagnosis: Correlation with Genetic Mutations and Optimization of Laser Wavelengths
Essential thrombocythemia (ET) is a type of myeloproliferative neoplasm that increases the risk of thrombosis. To diagnose this disease, the analysis of mutations in the Janus Kinase 2 (JAK2), thrombopoietin receptor (MPL), or calreticulin (CALR) gene is recommended. Disease poses diagnostic challenges due to overlapping mutations with other neoplasms and the presence of triple-negative cases. This study explores the potential of Raman spectroscopy combined with machine learning for ET diagnosis. We assessed two laser wavelengths (785, 1064 nm) to differentiate between ET patients and healthy controls. The PCR results indicate that approximately 50% of patients in our group have a mutation in the JAK2 gene, while only 5% of patients harbor a mutation in the ASXL1 gene. Additionally, only one patient had a mutation in the IDH1 and one had a mutation in IDH2 gene. Consequently, patients having no mutations were also observed in our group, making diagnosis challenging. Raman spectra at 1064 nm showed lower amide, polysaccharide, and lipid vibrations in ET patients, while 785 nm spectra indicated significant decreases in amide II and C-H lipid vibrations. Principal Component Analysis (PCA) confirmed that both wavelengths could distinguish ET from healthy subjects. Support Vector Machine (SVM) analysis revealed that the 800–1800 cm−1 range provided the highest diagnostic accuracy, with 89% for 785 nm and 72% for 1064 nm. These findings suggest that FT-Raman spectroscopy, paired with multivariate and machine learning analyses, offers a promising method for diagnosing ET with high accuracy by detecting specific molecular changes in serum. Principal Component Analysis (PCA) confirmed that both wavelengths could distinguish ET from healthy subjects. Support Vector Machine (SVM) analysis revealed that the 800–1800 cm−1 range provided the highest diagnostic accuracy, with 89% for 785 nm and 72% for 1064 nm. These findings suggest that FT-Raman spectroscopy, paired with multivariate and machine learning analyses, offers a promising method for diagnosing ET with high accuracy by detecting specific molecular changes in serum.
- Open Access
- 1 June 2024
- Published by IOP Publishing in New Journal of Physics
- Vol. 26 (6) , 063008
Electron–phonon coupling and a resonant-like optical observation of a band inversion in topological crystal insulator Pb1−x Sn x Se
The optical reflectivity of n-type Pb0.865Sn0.135Se and Pb0.75Sn0.25Se solid solutions was measured in the THz spectral region energetically corresponding to optical phonon excitations and in the temperature range from 40 K to 280 K. The first solid solution exhibits an open energy gap with trivial band ordering at all temperatures, while for the second one the transition from trivial insulator to topological crystal insulator phase is expected. The analysis of Pb0.75Sn0.25Se data performed within the dynamic dielectric function formalism revealed an anomaly of resonance-like character in the temperature dependence of LO phonon frequency. The formula for LO phonon energy renormalization reproduced observed anomaly for energy gap equal to zero, the phase transition occurred at T 0 = (172 ± 2) K. This effect was absent for Pb0.865Sn0.135Se. Present results show that reflectivity measurements in the THz range in the vicinity of LO phonon frequency can be valuable experimental method for precise determining of band inversion temperature in narrow-gap topological materials.
- 1 June 2024
- Published by IOP Publishing in New Journal of Physics
- Vol. 26 (6) , 063008
Open AccessElectron–phonon coupling and a resonant-like optical observation of a band inversion in topological crystal insulator Pb1−x Sn x Se
The optical reflectivity of n-type Pb0.865Sn0.135Se and Pb0.75Sn0.25Se solid solutions was measured in the THz spectral region energetically corresponding to optical phonon excitations and in the temperature range from 40 K to 280 K. The first solid solution exhibits an open energy gap with trivial band ordering at all temperatures, while for the second one the transition from trivial insulator to topological crystal insulator phase is expected. The analysis of Pb0.75Sn0.25Se data performed within the dynamic dielectric function formalism revealed an anomaly of resonance-like character in the temperature dependence of LO phonon frequency. The formula for LO phonon energy renormalization reproduced observed anomaly for energy gap equal to zero, the phase transition occurred at T 0 = (172 ± 2) K. This effect was absent for Pb0.865Sn0.135Se. Present results show that reflectivity measurements in the THz range in the vicinity of LO phonon frequency can be valuable experimental method for precise determining of band inversion temperature in narrow-gap topological materials.
- Open Access
Equimolar As4S4/Fe3O4 Nanocomposites Fabricated by Dry and Wet Mechanochemistry: Some Insights on the Magnetic–Fluorescent Functionalization of an Old Drug
Multifunctional nanocomposites from an equimolar As4S4/Fe3O4 cut section have been successfully fabricated from coarse-grained bulky counterparts, employing two-step mechanochemical processing in a high-energy mill operational in dry- and wet-milling modes (in an aqueous solution of Poloxamer 407 acting as a surfactant). As was inferred from the X-ray diffraction analysis, these surfactant-free and surfactant-capped nanocomposites are β-As4S4-bearing nanocrystalline–amorphous substances supplemented by an iso-compositional amorphous phase (a-AsS), both principal constituents (monoclinic β-As4S4 and cubic Fe3O4) being core–shell structured and enriched after wet milling by contamination products (such as nanocrystalline–amorphous zirconia), suppressing their nanocrystalline behavior. The fluorescence and magnetic properties of these nanocomposites are intricate, being tuned by the sizes of the nanoparticles and their interfaces, dependent on storage after nanocomposite fabrication. A specific core–shell arrangement consisted of inner and outer shell interfaces around quantum-confined nm-sized β-As4S4 crystallites hosting a-AsS, and the capping agent is responsible for the blue-cyan fluorescence in as-fabricated Poloxamer capped nanocomposites peaking at ~417 nm and ~442 nm, while fluorescence quenching in one-year-aged nanocomposites is explained in terms of their destroyed core–shell architectures. The magnetic co-functionalization of these nanocomposites is defined by size-extended heterogeneous shells around homogeneous nanocrystalline Fe3O4 cores, composed by an admixture of amorphous phase (a-AsS), nanocrystalline–amorphous zirconia as products of contamination in the wet-milling mode, and surfactant.
Open AccessEquimolar As4S4/Fe3O4 Nanocomposites Fabricated by Dry and Wet Mechanochemistry: Some Insights on the Magnetic–Fluorescent Functionalization of an Old Drug
Multifunctional nanocomposites from an equimolar As4S4/Fe3O4 cut section have been successfully fabricated from coarse-grained bulky counterparts, employing two-step mechanochemical processing in a high-energy mill operational in dry- and wet-milling modes (in an aqueous solution of Poloxamer 407 acting as a surfactant). As was inferred from the X-ray diffraction analysis, these surfactant-free and surfactant-capped nanocomposites are β-As4S4-bearing nanocrystalline–amorphous substances supplemented by an iso-compositional amorphous phase (a-AsS), both principal constituents (monoclinic β-As4S4 and cubic Fe3O4) being core–shell structured and enriched after wet milling by contamination products (such as nanocrystalline–amorphous zirconia), suppressing their nanocrystalline behavior. The fluorescence and magnetic properties of these nanocomposites are intricate, being tuned by the sizes of the nanoparticles and their interfaces, dependent on storage after nanocomposite fabrication. A specific core–shell arrangement consisted of inner and outer shell interfaces around quantum-confined nm-sized β-As4S4 crystallites hosting a-AsS, and the capping agent is responsible for the blue-cyan fluorescence in as-fabricated Poloxamer capped nanocomposites peaking at ~417 nm and ~442 nm, while fluorescence quenching in one-year-aged nanocomposites is explained in terms of their destroyed core–shell architectures. The magnetic co-functionalization of these nanocomposites is defined by size-extended heterogeneous shells around homogeneous nanocrystalline Fe3O4 cores, composed by an admixture of amorphous phase (a-AsS), nanocrystalline–amorphous zirconia as products of contamination in the wet-milling mode, and surfactant.