Philipp Henzler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philipp Henzler has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Alfred Leitenstorfer
University of Konstanz
2 shared publications - Denis V. Seletskiy
Department of Engineering Physics, Polytechnique Montreal, Montreal, Canada
2 shared publications K. Brunner
Institute of Physics, EP3, University of Würzburg, D-97074 Würzburg, Germany
2 shared publicationsS. Mahapatra
Institute of Physics, EP3, University of Würzburg, D-97074 Würzburg, Germany
2 shared publicationsA. Leitenstorfer
Department of Physics and Center for Applied Photonics, University of Konstanz, D-78464 Konstanz, Germany
1 shared publicationAlfred Leitenstorfer
1 shared publication
Latest Publications
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 18, Tu4A.48
Ultrafast Local Sensing of Strain and Temperature with a Single Semiconductor Quantum Dot
Femtosecond pump-probe microscopy of individual semiconductor quantum dots reveals energy shifts induced by coherent strain waves and the transition to incoherent heating at the nanoscale.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 18, Tu4A.48
Ultrafast Local Sensing of Strain and Temperature with a Single Semiconductor Quantum Dot
Femtosecond pump-probe microscopy of individual semiconductor quantum dots reveals energy shifts induced by coherent strain waves and the transition to incoherent heating at the nanoscale.
- 9 February 2021
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 126 (6) , 067402
Femtosecond Transfer and Manipulation of Persistent Hot-Trion Coherence in a Single Quantum DotUltrafast transmission changes around the fundamental trion resonance are studied after exciting a -shell exciton in a negatively charged II-VI quantum dot. The biexcitonic induced absorption reveals quantum beats between hot-trion states at 133 GHz. While interband dephasing is dominated by relaxation of the -shell hole within 390 fs, trionic coherence remains stored in the spin system for 85 ps due to Pauli blocking of the triplet electron. The complex spectrotemporal evolution of transmission is explained analytically by solving the Maxwell-Liouville equations. Pump and probe polarizations provide full control over amplitude and phase of the quantum beats.- 9 February 2021
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 126 (6) , 067402
Femtosecond Transfer and Manipulation of Persistent Hot-Trion Coherence in a Single Quantum DotUltrafast transmission changes around the fundamental trion resonance are studied after exciting a -shell exciton in a negatively charged II-VI quantum dot. The biexcitonic induced absorption reveals quantum beats between hot-trion states at 133 GHz. While interband dephasing is dominated by relaxation of the -shell hole within 390 fs, trionic coherence remains stored in the spin system for 85 ps due to Pauli blocking of the triplet electron. The complex spectrotemporal evolution of transmission is explained analytically by solving the Maxwell-Liouville equations. Pump and probe polarizations provide full control over amplitude and phase of the quantum beats.- 19 August 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (17) , 4714-4717
Passive elimination of correlated amplitude fluctuations in ultrabroadband supercontinua from highly nonlinear fibers by three-wave mixing
The nonlinear transformation of fluctuations by frequency broadening is found to produce strong anti-correlations in the spectral output. This effect is investigated by dispersive Fourier transform measurements. We exploit the anti-correlations in order to cancel the intensity noise in a subsequent sum-frequency mixing step. This principle allows for the generation of tunable visible pulses by cascaded nonlinear mixing whilst maintaining the same intensity noise performance as the input pulses. In addition, we demonstrate that the power fluctuations occurring in the process of passive stabilization of the carrier-envelope phase locking via difference frequency generation may be cancelled by an analogous strategy.
- 19 August 2020
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (17) , 4714-4717
Passive elimination of correlated amplitude fluctuations in ultrabroadband supercontinua from highly nonlinear fibers by three-wave mixing
The nonlinear transformation of fluctuations by frequency broadening is found to produce strong anti-correlations in the spectral output. This effect is investigated by dispersive Fourier transform measurements. We exploit the anti-correlations in order to cancel the intensity noise in a subsequent sum-frequency mixing step. This principle allows for the generation of tunable visible pulses by cascaded nonlinear mixing whilst maintaining the same intensity noise performance as the input pulses. In addition, we demonstrate that the power fluctuations occurring in the process of passive stabilization of the carrier-envelope phase locking via difference frequency generation may be cancelled by an analogous strategy.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 123003
Multicolor femtosecond pump-probe system with single-electron sensitivity at low temperatures and high magnetic fields
We present an ultrafast spectroscopy system designed for temporal and spectral resolution of transient transmission changes after excitation of single electrons in solid-state quantum structures. The system is designed for optimum long-term stability, offering the option of hands-off operation over several days. Pump and probe pulses are generated in a versatile Er:fiber laser system where visible photon energies may be tuned independently from 1.90 eV to 2.51 eV in three parallel branches. Bandwidth-limited pulse durations between 100 fs and 10 ps are available. The solid-state quantum systems under investigation are mounted in a closed-cycle superconducting magnet cryostat providing temperatures down to 1.6 K and magnetic fields of up to 9 T. The free-standing cryomagnet is coupled to the laser system by means of a high-bandwidth active beam steering unit to eliminate residual low-frequency mechanical vibrations of the pulse tube coolers. High-NA objective lenses inside the sample chamber are employed for focusing femtosecond laser pulses onto the sample and recollection of the transmission signal. The transmitted probe light is dispersed in a grating monochromator equipped with a liquid nitrogen-cooled CCD camera, enabling a frame rate of 559 Hz. In order to eliminate spurious background effects due to low-frequency changes in the thermal equilibrium of the sample, we operate with a lock-in scheme where, instead of the pump amplitude, the pump-probe timing is modulated. This feature is provided without any mechanical action by an electro-optic timing unit inside the femtosecond Er:fiber system. The performance of the instrument is tested with spectrally resolved pump-probe measurements on a single negatively charged CdSe/ZnSe quantum dot under a magnetic field of 9 T. Selective initialization and readout of charge and spin states is carried out via two different femtosecond laser pulses. High-quality results on subpicosecond intraband relaxation dynamics after single-electron excitation motivate a broad variety of future experiments in ultrafast quantum optics and few-fermion quantum dynamics.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 123003
Multicolor femtosecond pump-probe system with single-electron sensitivity at low temperatures and high magnetic fields
We present an ultrafast spectroscopy system designed for temporal and spectral resolution of transient transmission changes after excitation of single electrons in solid-state quantum structures. The system is designed for optimum long-term stability, offering the option of hands-off operation over several days. Pump and probe pulses are generated in a versatile Er:fiber laser system where visible photon energies may be tuned independently from 1.90 eV to 2.51 eV in three parallel branches. Bandwidth-limited pulse durations between 100 fs and 10 ps are available. The solid-state quantum systems under investigation are mounted in a closed-cycle superconducting magnet cryostat providing temperatures down to 1.6 K and magnetic fields of up to 9 T. The free-standing cryomagnet is coupled to the laser system by means of a high-bandwidth active beam steering unit to eliminate residual low-frequency mechanical vibrations of the pulse tube coolers. High-NA objective lenses inside the sample chamber are employed for focusing femtosecond laser pulses onto the sample and recollection of the transmission signal. The transmitted probe light is dispersed in a grating monochromator equipped with a liquid nitrogen-cooled CCD camera, enabling a frame rate of 559 Hz. In order to eliminate spurious background effects due to low-frequency changes in the thermal equilibrium of the sample, we operate with a lock-in scheme where, instead of the pump amplitude, the pump-probe timing is modulated. This feature is provided without any mechanical action by an electro-optic timing unit inside the femtosecond Er:fiber system. The performance of the instrument is tested with spectrally resolved pump-probe measurements on a single negatively charged CdSe/ZnSe quantum dot under a magnetic field of 9 T. Selective initialization and readout of charge and spin states is carried out via two different femtosecond laser pulses. High-quality results on subpicosecond intraband relaxation dynamics after single-electron excitation motivate a broad variety of future experiments in ultrafast quantum optics and few-fermion quantum dynamics.