Pengli Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pengli Bai has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Liang He
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China
21 shared publicationsXueyan Nan
Suzhou Institute of Biomedical Engineering and Technology Chinese Academy of Sciences Suzhou Jiangsu PR China
14 shared publicationsZhizhou Liu
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China
14 shared publicationsTong Wang
Chinese Academy of Sciences
13 shared publicationsLicheng Yu
College of Chemistry, Tianjin Key Laboratory of Biosensing and Molecular Recognition
5 shared publications- Tongxu Gu
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
5 shared publications
Latest Publications
- 16 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
High-Sensitivity Metal Tags Based on Grafted Polymers for Single-Cell Analysis of Cerebrospinal Fluid and Blood in Subarachnoid Hemorrhage with Mass Cytometry
Single-cell multi-index analysis of cerebrospinal fluid (CSF) is essential for elucidating neuroinflammation after subarachnoid hemorrhage (SAH). Mass cytometry (MC), which can measure 50 parameters at the single-cell level, is a promising technology for analyzing CSF samples exhibiting low cellularity. However, the application of MC in SAH is limited by its low sensitivity caused by the commercial metal-chelating polymer (MCP) reagents. This study presents a polymer−metal tagging strategy based on photografting polymerization, which enables a 5-fold enhancement in detection sensitivity across over 38 rare-earth metal channels while maintaining low non-specific adsorption for the first time. Leveraging this high-sensitivity system, we performed single-cell analysis of paired CSF and peripheral blood samples from 10 SAH patients using a 22-parameter panel, revealing the unique immune cell landscape of SAH. Two distinct cell subpopulations marked by CX3CR1, CD11b, and CD16 expression were identified, potentially correlating with disease progression. This work not only establishes a universal high-sensitivity metal-tag system for MC but also provides a powerful single-cell analysis tool for investigating central nervous system responses following SAH.
- 16 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
High-Sensitivity Metal Tags Based on Grafted Polymers for Single-Cell Analysis of Cerebrospinal Fluid and Blood in Subarachnoid Hemorrhage with Mass Cytometry
Single-cell multi-index analysis of cerebrospinal fluid (CSF) is essential for elucidating neuroinflammation after subarachnoid hemorrhage (SAH). Mass cytometry (MC), which can measure 50 parameters at the single-cell level, is a promising technology for analyzing CSF samples exhibiting low cellularity. However, the application of MC in SAH is limited by its low sensitivity caused by the commercial metal-chelating polymer (MCP) reagents. This study presents a polymer−metal tagging strategy based on photografting polymerization, which enables a 5-fold enhancement in detection sensitivity across over 38 rare-earth metal channels while maintaining low non-specific adsorption for the first time. Leveraging this high-sensitivity system, we performed single-cell analysis of paired CSF and peripheral blood samples from 10 SAH patients using a 22-parameter panel, revealing the unique immune cell landscape of SAH. Two distinct cell subpopulations marked by CX3CR1, CD11b, and CD16 expression were identified, potentially correlating with disease progression. This work not only establishes a universal high-sensitivity metal-tag system for MC but also provides a powerful single-cell analysis tool for investigating central nervous system responses following SAH.
- Open Access
- 2 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (25) , e74529
High‐Sensitive Mass Cytometry Metal Tags Based on Noble Metal Nanoparticles Assisting Acute Myeloid Leukemia Immune Checkpoint Profiling
Mass cytometry is optimal for acute leukemia immune checkpoint profiling. However, current commercial metal‐chelating polymer (MCP) metal tags limit its sensitivity due to low metal loading capacity. We report a novel synthetic strategy employing antibody‐conjugated gold or platinum nanoparticles (AuNP/PtNP) for high‐dimensional single‐cell immunophenotyping in both single cell suspension mass cytometry and imaging mass cytometry. Extremely low‐dose AuNP (34 NPs/cell) exhibited MCP‐comparable sensitivity, while high doses enabled up to 48‐fold signal amplification. Furthermore, integration of the detection of low‐abundance TIGIT and OX40 by AuNP/PtNP tags and other 22 biomarkers by MCP tags, three significantly distinct T cell subpopulations in healthy donor and acute myeloid leukemia samples were identified, providing new targets and intervention strategies for the diagnosis and treatment of acute myeloid leukemia. The proposed strategies demonstrate that noble metal NP‐based tags show promising potential in detection of low‐abundance cell surface biomarkers and enhance MC implementation in both biomedical and clinical applications.
- 2 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (25) , e74529
Open AccessHigh‐Sensitive Mass Cytometry Metal Tags Based on Noble Metal Nanoparticles Assisting Acute Myeloid Leukemia Immune Checkpoint Profiling
Mass cytometry is optimal for acute leukemia immune checkpoint profiling. However, current commercial metal‐chelating polymer (MCP) metal tags limit its sensitivity due to low metal loading capacity. We report a novel synthetic strategy employing antibody‐conjugated gold or platinum nanoparticles (AuNP/PtNP) for high‐dimensional single‐cell immunophenotyping in both single cell suspension mass cytometry and imaging mass cytometry. Extremely low‐dose AuNP (34 NPs/cell) exhibited MCP‐comparable sensitivity, while high doses enabled up to 48‐fold signal amplification. Furthermore, integration of the detection of low‐abundance TIGIT and OX40 by AuNP/PtNP tags and other 22 biomarkers by MCP tags, three significantly distinct T cell subpopulations in healthy donor and acute myeloid leukemia samples were identified, providing new targets and intervention strategies for the diagnosis and treatment of acute myeloid leukemia. The proposed strategies demonstrate that noble metal NP‐based tags show promising potential in detection of low‐abundance cell surface biomarkers and enhance MC implementation in both biomedical and clinical applications.
- Open Access
- 27 February 2026
- Published by Elsevier in SSRN Electronic Journal
Ultrasensitive and Multi-Analyte Detection of Catecholamines in Serum and Cerebrospinal Fluid Using Carboxyl-Modified Magnetic Microspheres Coupled with LC/MS
Catecholamines (CAs) are crucial markers of several disease. However, the existing method cannot afford enough target analytes and sufficient sensitivity. This study developed a new kind of carboxyl-functionalized hydrophilic lipophilic balanced magnetic beads (HLBMB-SCOOH) for efficient extraction and detection of CAs in human serum and cerebrospinal fluid (CSF). The microspheres were prepared via suspension polymerization and surface functionalization of carboxyl. As adsorbents in magnetic solid-phase extraction (MSPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), they enabled ultrasensitive analysis of six catecholamines simultaneously. The established method exhibited excellent linear range of 10-10,000 ng/L, with a limit of detection as low as 1.33 ng/L. Satisfactory spiked recoveries of 88.2%-108.4% were achieved, with relative standard deviations below 9.1%. The samples of CSF and blood of subarachnoid hemorrhage (SAH) patients were analyzed by the proposed method, which showed consistently higher catecholamine concentrations in CSF than in blood across measured biomarkers. The proposed MSPE procedure is simple, efficient, and robust, providing a reliable approach for trace catecholamine analysis in blood serum and CSF, which may be used for treatment evaluation of SAH and other neurological disease.
- 27 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessUltrasensitive and Multi-Analyte Detection of Catecholamines in Serum and Cerebrospinal Fluid Using Carboxyl-Modified Magnetic Microspheres Coupled with LC/MS
Catecholamines (CAs) are crucial markers of several disease. However, the existing method cannot afford enough target analytes and sufficient sensitivity. This study developed a new kind of carboxyl-functionalized hydrophilic lipophilic balanced magnetic beads (HLBMB-SCOOH) for efficient extraction and detection of CAs in human serum and cerebrospinal fluid (CSF). The microspheres were prepared via suspension polymerization and surface functionalization of carboxyl. As adsorbents in magnetic solid-phase extraction (MSPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), they enabled ultrasensitive analysis of six catecholamines simultaneously. The established method exhibited excellent linear range of 10-10,000 ng/L, with a limit of detection as low as 1.33 ng/L. Satisfactory spiked recoveries of 88.2%-108.4% were achieved, with relative standard deviations below 9.1%. The samples of CSF and blood of subarachnoid hemorrhage (SAH) patients were analyzed by the proposed method, which showed consistently higher catecholamine concentrations in CSF than in blood across measured biomarkers. The proposed MSPE procedure is simple, efficient, and robust, providing a reliable approach for trace catecholamine analysis in blood serum and CSF, which may be used for treatment evaluation of SAH and other neurological disease.
- 4 February 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (6) , 4834-4844
Porphyrinic Metal–Organic Frameworks with Longitudinal Pt Deposition Referenced as Opto/Catalytic Adjuvants for Dual-Path Glycoprotein Assay
In this work, porphyrinic metal-organic frameworks (MOFs) with longitudinal Pt deposition were developed for the inspired establishment of opto/catalytic adjuvants referenced for a dual-path glycoprotein assay. In the compositional cooperation, porphyrinic MOFs were synthesized through Zr oxoclusters and polytopic porphyrin ligands into a benchmark template (PCN-222), followed by catalytic Pt nanowire deposition (PtNW@PCN-222). As for signal reflection, the fluorogenic species (i.e., resazurin and amplex red) were integrated into zeolitic imidazolate framework-8 (ZIF-8) via epitaxial shell growth to guide lectin integration. The specific performance toward glycoprotein recognition was guaranteed by both antibody-antigen interaction as well as glycan epitope binding through lectin affinity, and the signal response was initiated by textural decomposition of the ZIF-8 skeleton in a controllable manner. On one hand, PtNW@PCN-222 can function as the catalytic adjuvant to exert the fluorogenic reactions: a reductive N-deoxygenation of resazurin and an oxidative N-deacetylation of amplex red, in which both the redox reactions generated the fluorescent species of resorufin products. On the other hand, PtNW@PCN-222 with endogenous periodical arrangement of porphyrin ligands can be tailored as an optical adjuvant for reporting signal reference. For benefits, the comprehensive functions leaned on the catalytic performance and optical reference property from PtNW@PCN-222 can be harvested for a ratiometric glycoprotein assay. Besides, due to the variant catalytic converter of PtNW@PCN-222 involved in the two fluorogenic reactions, the proposed glycoprotein assay exhibited a range of 0.03-3 nM with a detection limit of 7.91 pM in the reductive pathway, and showed a linear range from 0.06 to 10 nM with a detection limit of 21.64 pM in the oxidative pathway. Collectively, our proposed glycoprotein assay may provide a new thought in opto/catalytic MOF adjuvant-empowered ratiometric sensing in the dual-path reflection manner, which may also reinforce the accurate detection capability for the glycoprotein assay.
- 4 February 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (6) , 4834-4844
Porphyrinic Metal–Organic Frameworks with Longitudinal Pt Deposition Referenced as Opto/Catalytic Adjuvants for Dual-Path Glycoprotein Assay
In this work, porphyrinic metal-organic frameworks (MOFs) with longitudinal Pt deposition were developed for the inspired establishment of opto/catalytic adjuvants referenced for a dual-path glycoprotein assay. In the compositional cooperation, porphyrinic MOFs were synthesized through Zr oxoclusters and polytopic porphyrin ligands into a benchmark template (PCN-222), followed by catalytic Pt nanowire deposition (PtNW@PCN-222). As for signal reflection, the fluorogenic species (i.e., resazurin and amplex red) were integrated into zeolitic imidazolate framework-8 (ZIF-8) via epitaxial shell growth to guide lectin integration. The specific performance toward glycoprotein recognition was guaranteed by both antibody-antigen interaction as well as glycan epitope binding through lectin affinity, and the signal response was initiated by textural decomposition of the ZIF-8 skeleton in a controllable manner. On one hand, PtNW@PCN-222 can function as the catalytic adjuvant to exert the fluorogenic reactions: a reductive N-deoxygenation of resazurin and an oxidative N-deacetylation of amplex red, in which both the redox reactions generated the fluorescent species of resorufin products. On the other hand, PtNW@PCN-222 with endogenous periodical arrangement of porphyrin ligands can be tailored as an optical adjuvant for reporting signal reference. For benefits, the comprehensive functions leaned on the catalytic performance and optical reference property from PtNW@PCN-222 can be harvested for a ratiometric glycoprotein assay. Besides, due to the variant catalytic converter of PtNW@PCN-222 involved in the two fluorogenic reactions, the proposed glycoprotein assay exhibited a range of 0.03-3 nM with a detection limit of 7.91 pM in the reductive pathway, and showed a linear range from 0.06 to 10 nM with a detection limit of 21.64 pM in the oxidative pathway. Collectively, our proposed glycoprotein assay may provide a new thought in opto/catalytic MOF adjuvant-empowered ratiometric sensing in the dual-path reflection manner, which may also reinforce the accurate detection capability for the glycoprotein assay.
- 16 January 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (4) , 2946-2955
Natural Cell-Inspired Integration of Redox Reactant Molecules in Hierarchical MOFs Harvested for Reaction Pathway-Regulated Glycoprotein Assay
Natural cell systems with multiple isolated compartments possess controllable signal transduction pathways, which can segregate a series of complex substances and confine them from each other to allow for feedback-driven reactions. By biomimicking the ingenuity of cell systems, we herein designed spatially compact metal-organic frameworks (MOFs) as a hierarchical host for complex substances at isolated locations for the development of reaction pathway-regulated glycoprotein assay. The well-defined zeolitic imidazolate framework-8 (ZIF-8) matrices were fabricated via epitaxial growth to organize the multishelled integration of multiple guest substances including redox reactant substrates (i.e., resazurin and amplex red) and Pt-shelled Au (AuPt) entities. In addition, the micropore nature and enclosed space of the ZIF-8 matrix can prohibit the surpassed contact between fluorogenic substrates and catalytic AuPt converters, inherently, while the immediate signal generator pattern can be harvested through textural collapse of the ZIF-8 skeleton in a controllable manner. Our proposed glycoprotein assay can be conducted with on-demand redox reactions for signal generators: a reductive N-deoxygenation of resazurin and an oxidative N-deacetylation of amplex red, respectively. Due to the distinct catalytic behavior of AuPt converters involved in the fluorogenic redox reactions, the detection limit of the reaction pathway-regulated glycoprotein assay can reach 14.27 pM for the reductive N-deoxygenation reaction and 71.63 pM for the oxidative N-deacetylation reaction, respectively. Collectively, our proposed method may offer an innovative inspiration of reaction pathway-regulated glycoprotein assay, and it can also be adapted for rational substitution of substrate molecules to broaden its signal reflections in versatile glycoprotein analysis.
- 16 January 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (4) , 2946-2955
Natural Cell-Inspired Integration of Redox Reactant Molecules in Hierarchical MOFs Harvested for Reaction Pathway-Regulated Glycoprotein Assay
Natural cell systems with multiple isolated compartments possess controllable signal transduction pathways, which can segregate a series of complex substances and confine them from each other to allow for feedback-driven reactions. By biomimicking the ingenuity of cell systems, we herein designed spatially compact metal-organic frameworks (MOFs) as a hierarchical host for complex substances at isolated locations for the development of reaction pathway-regulated glycoprotein assay. The well-defined zeolitic imidazolate framework-8 (ZIF-8) matrices were fabricated via epitaxial growth to organize the multishelled integration of multiple guest substances including redox reactant substrates (i.e., resazurin and amplex red) and Pt-shelled Au (AuPt) entities. In addition, the micropore nature and enclosed space of the ZIF-8 matrix can prohibit the surpassed contact between fluorogenic substrates and catalytic AuPt converters, inherently, while the immediate signal generator pattern can be harvested through textural collapse of the ZIF-8 skeleton in a controllable manner. Our proposed glycoprotein assay can be conducted with on-demand redox reactions for signal generators: a reductive N-deoxygenation of resazurin and an oxidative N-deacetylation of amplex red, respectively. Due to the distinct catalytic behavior of AuPt converters involved in the fluorogenic redox reactions, the detection limit of the reaction pathway-regulated glycoprotein assay can reach 14.27 pM for the reductive N-deoxygenation reaction and 71.63 pM for the oxidative N-deacetylation reaction, respectively. Collectively, our proposed method may offer an innovative inspiration of reaction pathway-regulated glycoprotein assay, and it can also be adapted for rational substitution of substrate molecules to broaden its signal reflections in versatile glycoprotein analysis.
- Open Access
Functional Groups‐Driven Molecular Design for Broad‐Spectrum Clusteroluminescence in Scalable Monodisperse Polymer Microspheres
Achieving multicolor, precisely tunable cluster‐induced emission in nonconjugated polymers remains a considerable challenge. Herein, we present a generalizable and scalable methodology for fabricating monodisperse, color‐tunable clusteroluminescence (CL) microspheres, enabling multimodal color tuning across the spectrum from blue to orange‐red through precise control of monomer type and ratio, sulfonation time, and pH conditions. Density functional theory (DFT) simulations demonstrate that conformational rigidity, resulting from the synergistic combination of prevalent hydrogen‐bonding interactions, short interatomic contacts, and oxygen cluster formation, significantly enhances emission efficiency, leading to dual broadband visible emissions across the 400–700 nm wavelength range. The optimized sulfonated poly(divinylbenzene‐styrene‐methyl methacrylate) microspheres with 30% methyl methacrylate (MMA) content (SPSMMAs‐30) exhibit excellent monodispersity and strong fluorescence across 13 standard channels of flow cytometry, with fluorescence coefficient of variation (CV) values consistently below 3%, fulfilling requirements for routine flow cytometer calibration. Compared with commercial calibration microspheres, SPSMMAs‐30 show significantly higher photobleaching resistance and long‐term environmental stability. Significantly, this protocol enables the first kilogram‐scale synthesis of CL microspheres with highly reproducible optical properties. Furthermore, SPSMMAs‐30 demonstrate sensitive tetracycline detection and promising performance in multicolor anticounterfeiting applications, substantially broadening the scope of nonconjugated CL materials for biomedicine, diagnostics, and materials science.
Open AccessFunctional Groups‐Driven Molecular Design for Broad‐Spectrum Clusteroluminescence in Scalable Monodisperse Polymer Microspheres
Achieving multicolor, precisely tunable cluster‐induced emission in nonconjugated polymers remains a considerable challenge. Herein, we present a generalizable and scalable methodology for fabricating monodisperse, color‐tunable clusteroluminescence (CL) microspheres, enabling multimodal color tuning across the spectrum from blue to orange‐red through precise control of monomer type and ratio, sulfonation time, and pH conditions. Density functional theory (DFT) simulations demonstrate that conformational rigidity, resulting from the synergistic combination of prevalent hydrogen‐bonding interactions, short interatomic contacts, and oxygen cluster formation, significantly enhances emission efficiency, leading to dual broadband visible emissions across the 400–700 nm wavelength range. The optimized sulfonated poly(divinylbenzene‐styrene‐methyl methacrylate) microspheres with 30% methyl methacrylate (MMA) content (SPSMMAs‐30) exhibit excellent monodispersity and strong fluorescence across 13 standard channels of flow cytometry, with fluorescence coefficient of variation (CV) values consistently below 3%, fulfilling requirements for routine flow cytometer calibration. Compared with commercial calibration microspheres, SPSMMAs‐30 show significantly higher photobleaching resistance and long‐term environmental stability. Significantly, this protocol enables the first kilogram‐scale synthesis of CL microspheres with highly reproducible optical properties. Furthermore, SPSMMAs‐30 demonstrate sensitive tetracycline detection and promising performance in multicolor anticounterfeiting applications, substantially broadening the scope of nonconjugated CL materials for biomedicine, diagnostics, and materials science.
- Open Access
- 2 September 2025
- Published by Wiley
Functional Groups-Driven Molecular Design for Broad-Spectrum Clusteroluminescence in Scalable Monodisperse Polymer Microspheres
Tunable cluster luminescence (CL) in non-conjugated polymers is a longstanding challenge due to lacking efficient molecular design strategies. Herein, we report a generalizable, scalable method to fabricate monodisperse, color-tunable CL microspheres by doping cross-linked polystyrene with carboxyl-containing monomers. Aggregated chromophores in the confined network exhibit enhanced dual emission via through-space interactions (TSI) of carboxyl groups and conformational rigidity induced by hydrogen bonding/coordination, spanning 400–700 nm. Emission is precisely tuned by varying carboxyl monomer types/ratios, sulfonation time, and pH. The optimized SPSMMAs-30 (30% MMA) features uniform size and strong fluorescence across 13 flow cytometry channels (coefficient of variation <3%), meeting calibration requirements. Crucially, this enables the first kilogram-scale synthesis of CL calibration microspheres with consistent optical properties. Beyond calibration, it shows high sensitivity in tetracycline detection and promise for multicolor anti-counterfeiting. This simple, cost-effective approach expands CL’s material design space and application potential in biomedicine, diagnostics, and materials science.
- 2 September 2025
- Published by Wiley
Open AccessFunctional Groups-Driven Molecular Design for Broad-Spectrum Clusteroluminescence in Scalable Monodisperse Polymer Microspheres
Tunable cluster luminescence (CL) in non-conjugated polymers is a longstanding challenge due to lacking efficient molecular design strategies. Herein, we report a generalizable, scalable method to fabricate monodisperse, color-tunable CL microspheres by doping cross-linked polystyrene with carboxyl-containing monomers. Aggregated chromophores in the confined network exhibit enhanced dual emission via through-space interactions (TSI) of carboxyl groups and conformational rigidity induced by hydrogen bonding/coordination, spanning 400–700 nm. Emission is precisely tuned by varying carboxyl monomer types/ratios, sulfonation time, and pH. The optimized SPSMMAs-30 (30% MMA) features uniform size and strong fluorescence across 13 flow cytometry channels (coefficient of variation <3%), meeting calibration requirements. Crucially, this enables the first kilogram-scale synthesis of CL calibration microspheres with consistent optical properties. Beyond calibration, it shows high sensitivity in tetracycline detection and promise for multicolor anti-counterfeiting. This simple, cost-effective approach expands CL’s material design space and application potential in biomedicine, diagnostics, and materials science.
- 16 July 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (2)
Self‐Assembled Stable Magnetic COF Super‐Particles Through Electrostatic Interaction for Efficient Removal and Detection of PFAS Combined with LC‐MS/MS
The stability and biological toxicity of per‐ and polyfluoroalkyl substances (PFAS) are currently the most severe environmental issues, posing a huge threat to human health. The governance and detection of PFAS is currently a huge challenge. Herein, a dual‐functionalized spherical covalent organic framework (COF) is developed with fluorine and cationic groups, combined with magnetic nanoparticles to form binary magnetic COF super‐particles (SPs). The COF has high crystallinity, a spherical and hollow structure, and a strong positive charge. SPs exhibited broad‐spectrum and high adsorption capability toward PFAS (631 mg g −1 for perfluorooctanoic acid (PFOA)) and rapid equilibrium (−1 for 18 PFAS compounds. The method achieved high recovery (80%–120%) in environmental and biological samples, demonstrating robust performance for PFAS removal and trace analysis.
- 16 July 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (2)
Self‐Assembled Stable Magnetic COF Super‐Particles Through Electrostatic Interaction for Efficient Removal and Detection of PFAS Combined with LC‐MS/MS
The stability and biological toxicity of per‐ and polyfluoroalkyl substances (PFAS) are currently the most severe environmental issues, posing a huge threat to human health. The governance and detection of PFAS is currently a huge challenge. Herein, a dual‐functionalized spherical covalent organic framework (COF) is developed with fluorine and cationic groups, combined with magnetic nanoparticles to form binary magnetic COF super‐particles (SPs). The COF has high crystallinity, a spherical and hollow structure, and a strong positive charge. SPs exhibited broad‐spectrum and high adsorption capability toward PFAS (631 mg g −1 for perfluorooctanoic acid (PFOA)) and rapid equilibrium (−1 for 18 PFAS compounds. The method achieved high recovery (80%–120%) in environmental and biological samples, demonstrating robust performance for PFAS removal and trace analysis.