KKKazuhiro Katada

Kazuhiro Katada

*This is an algorithmically generated author record based on publicly available information.

Kazuhiro Katada has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Visualization of Lenticulostriate Arteries on CT Angiography Using Ultra-High-Resolution CT Compared with Conventional-Detector CT

    by K. Murayama, S. Suzuki, H. Nagata, J. Oda, I. Nakahara, K. Katada, K. Fujii, H. Toyama

    BACKGROUND AND PURPOSE: The newly developed ultra-high-resolution CT is equipped with a 0.25-mm detector, which has one-half the conventional section thickness, one-half the in-plane detector element width, and one-half the reconstructed pixel width compared with conventional-detector CT. Thus, the ultra-high-resolution CT scanner should provide better image quality for microvasculature than the conventional-detector CT scanners. This study aimed to determine whether ultra-high-resolution CT produces superior-quality images of the lenticulostriate arteries compared with conventional-detector CT. MATERIALS AND METHODS: From February 2017 to June 2017, thirteen patients with aneurysms (4 men, 9 women; mean age, 61.2 years) who underwent head CTA with both ultra-high-resolution CT and conventional-detector CT were enrolled. Two board-certified radiologists determined the number of all lenticulostriate arteries on the CTA coronal images of the MCA M1 segment reconstructed from 512 matrixes on conventional-detector CT and 1024 matrixes on ultra-high-resolution CT. RESULTS: There were statistically more lenticulostriate arteries identified on ultra-high-resolution CT (average, 2.85 ± 0.83; 95% CI, 2.509–3.183) than on conventional-detector CT (average, 2.17 ± 0.76; 95% CI, 1.866–2.480) (P = .009) in 16 of the total 26 MCA M1 segments. CONCLUSIONS: Improvements in lenticulostriate artery visualization were the result of the combined package of the ultra-high-resolution CT scanner plus the ultra-high-resolution scanning protocol, which includes higher radiation doses with lower than the national diagnostic reference levels and stronger adaptive iterative dose-reduction processing. This package for ultra-high-resolution CT is a simple, noninvasive, and easily accessible method to evaluate microvasculature such as the lenticulostriate arteries.


  • In vivo imaging of microglial activation using a peripheral benzodiazepine receptor ligand: [11C]PK-11195 and animal PET following ethanol injury in rat striatum

    by Hiroshi Toyama, Kentaro Hatano, Hiromi Suzuki, Masanori Ichise, Sotaro Momosaki, Gen Kudo, Fumitaka Ito, Takashi Kato, Hiroshi Yamaguchi, Kazuhiro Katada, et al.

    To investigate whether [11C]PK-11195, a specific peripheral benzodiazepine receptors (PBRs) ligand for positron emission tomography (PET), can show activated microglia in a rat brain injury model. On day 1, ethanol was injected into the rat’s right striatum (ST) using a stereotaxic operative procedure. On day 3, head magnetic resonance imaging (MRI) scans for surgically treated rats were performed to evaluate ethanol injury morphologically. On day 4, dynamic PET scans (17 injured rats and 7 non-injured controls) were performed for 60 min with an animal PET scanner under chloral hydrate anesthesia following a bolus injection of [11C]PK-11195 through tail vein. Because PBRs are present throughout the brain, there is no suitable receptor-free reference region. The reference tissue model may not be applicable because of low target to background ratio for low affinity of [11C]PK-11195 to PBRs. We evaluated the PBRs binding with regions of interest (ROIs)-based approach to estimate total distribution volume (V). We used an integral from 0 min to 60 min (V 60) as an estimate of V. On the coronal PET image, ROIs were placed on bilateral ST. Differences in right/left ST V 60 ratios between lesioned and unlesioned control rats were compared using unpaired t tests. Immunohistochemical staining was performed for confirming the presence of activated microglia following decapitation on the PET experiment day. The right/left ST V 60 ratios in lesioned rats (1.07 ± 0.08) were significantly higher than those in unlesioned control rats (1.00 ± 0.06, P < 0.05). On immunohistochemical staining, activated microglia were exclusively observed in the injured right ST but not in the noninjured left ST of the injury rats and the bilateral ST of the non-injured control rats. These results suggest that [11C]PK-11195 PET imaging would be a useful tool for evaluating microglial activation in a rat brain injury model.


  • Clinical usefulness of 3-D CT endoscopic imaging of cerebral aneurysms

    by Yoko Kato, Hirotoshi Sano, Kazuhiro Katada, Yuko Ogura, Narimasu Kanaoka, Tetsuya Yokoyama, Tetsuo Kanno

    Usefulness of endoscopic imaging of cerebral aneurysms is presented. 3-D luminal images were obtained using a new processing technique which extracts CT numbers in the boundary region between the vessel wall and contrast media filled in the vascular lumen. Clinical application of this technique to complicated large cerebral aneurysms showed that, with this 3-D CT endoscopic imaging, anatomical details of cerebral aneurysms such as the orifice of the aneurysm, intraluminal thrombus, and calcification of the wall could be clearly demonstrated. Using a 3-D imaging method by Helical CT virtual views of various surgical approaches were compared preoperatively. With this technique, not only virtual surgical views of aneurysms and related vasculature, but also surgical views after virtual resection of skull base bone to a desirable extent are freely available. We operated on two large, complicated aneurysms and one broad-based aneurysm after obtaining 3-D CT endoscopic images of the aneurysms. Such information was found to be very useful for determining difficult and complicated cerebral aneurysms and broad-based aneurysms for coil embolization or direct open surgery.


  • Open Access

    162. Evaluation of peripheral pulse gating method on MRI

    by Keishi Ogawa, Munetaka Sugiishi, Hirofumi Anno, Kazuhiro Katada, Koujiroh Yamaguti, Takehiko Goroh, Sigeki Saitoh

  • Open Access

    Large High-flow Arteriovenous Malformation Complicated by Normal Perfusion Pressure Breakthrough Syndrome

    by Yoko Kato, Masatoshi Sano, Fumihiro Imai, Koji Inoue, Mamoru Abe, Tetsuo Kanno, Kazuhiro Katada, Gen Takeshita, Hiroshi Toyama