PFPaul M. Foreman

Paul M. Foreman

*This is an algorithmically generated author record based on publicly available information.

Paul M. Foreman has a total of 452 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Contour Neurovascular System Versus Woven Endobridge for Endovascular Embolization of Cerebral Aneurysms: A Propensity Score-matched Cohort Study

    by Christoph J. Griessenauer, Sherief Ghozy, Hamza A. Salim, Nimer Adeeb, Basel Musmar, Alessandra Biondi, Fritz Wodarg, Thomas Liebig, Tufail Patankar, Sal Lamin, et al.

    BACKGROUND AND OBJECTIVES: The Woven Endobridge (WEB) and the Contour Neurovascular System (Contour) are both intrasaccular devices used to treat cerebral aneurysms. We compared outcomes of these 2 devices using data from 2 large registries. METHODS: Data were sourced from the WorldWideWEB Consortium, which included 1363 cases treated with WEB from 2017, and a registry of 277 Contour cases from 10 European centers starting the same year. Patient demographics, aneurysm characteristics, procedural specifics, and outcomes were analyzed. Propensity score matching was applied for comparison. RESULTS: Before matching, the Contour group had more men (37.9% vs 30.8%), more asymptomatic cases (83.4% vs 70.3%), and fewer acute subarachnoid hemorrhage cases (10.8% vs 26.2%). After matching, no significant differences were found in demographics or aneurysm characteristics between groups. The median age was 60 years, and median aneurysm dimensions were comparable. Logistic regression showed no significant differences between WEB and Contour in achieving complete occlusion (odds ratio [OR] = 1.01, 95% CI, 0.67-1.52, P = .971), adequate occlusion (OR = 0.85, 95% CI, 0.41-1.76, P = .665), or achieving modified Rankin Scale 0 to 2 at last follow-up (OR = 0.48, 95% CI, 0.21-1.02, P = .064). Retreatment (OR = 2.23, P = .086), thromboembolic complications (OR = 0.75, P = .452), and adjunctive treatment use (OR = 1.93, P = .141) were also similar. CONCLUSION: The WEB and Contour demonstrated comparable clinical and angiographic outcomes in this large multicenter study comprised majority small, asymptomatic cerebral aneurysms.

  • Predictive modeling of long-term improvement in occlusion outcomes following Woven EndoBridge treatment of cerebral aneurysms: A machine learning approach

    by Alireza Karandish, Muhammed Amir Essibayi, Mohamed Sobhi Jabal, Hamza Adel Salim, Basel Musmar, Nimer Adeeb, Mahmoud Dibas, Davide Simonato, Yan-Lin Li, James Grist, et al.

    Background: The Woven EndoBridge (WEB) device represents an innovative solution for cerebral aneurysm occlusion, particularly for challenging wide-neck bifurcation aneurysms. However, factors affecting sustained occlusion remain poorly understood. We utilized machine learning to attempt to identify predictors of favorable long-term outcomes following WEB treatment. Methods: In this multicenter retrospective study, we collected patient demographics, aneurysm characteristics, procedural details, and clinical outcomes. The primary endpoint was improvement in occlusion status, defined as maintained Raymond-Roy Occlusion Classification (RROC) grade 1, or improvement from grade 2 to 1, or from grade 3 to either 2 or 1 on final angiographic follow up. The dataset was split into training (75%) and validation (25%) sets. The CatBoost algorithm was selected based on performance metrics, with Shapley Additive exPlanations (SHAP) values calculated to determine feature importance. Furthermore, a multivariable binomial logistic regression model was performed to validate machine learning findings. Results: Among 720 aneurysms from 36 hospitals, 84% showed improvement in occlusion at follow up. Both machine learning and multivariable logistic regression identified aneurysm height as the most consistent correlate of nonimprovement (odds ratio (OR) 0.90 per mm, p = 0.022). In the CatBoost model, the highest-ranking features by SHAP included aneurysm height, patient age, treatment acuity, ACom location, WEB-SLS device, bifurcation anatomy, aneurysm multiplicity, baseline modified Rankin Scale, access route, and partial thrombosis. Conclusions: Machine-learning and regression analyses identified consistent predictors of occlusion improvement after WEB treatment, with aneurysm height most strongly linked to nonimprovement. These insights may guide patient selection and follow up. Findings require cautious interpretation and external validation in larger cohorts.


  • Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms—A retrospective analysis of the WorldWide WEB Consortium database

    by Basel Musmar, Nimer Adeeb, Julian Gendreau, Melanie Alfonzo Horowitz, Hamza Adel Salim, Praveen Sanmugananthan, Assala Aslan, Nolan J Brown, Nicole M Cancelliere, Rachel M McLellan, et al.

    Background: Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond–Roy classification 1 or 2) remains challenging. Objective: Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. Methods: We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. Results: A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535–0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024–0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer–Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/ . Conclusion: The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.


  • Predictors of Aneurysm Obliteration in Patients Treated with the WEB Device: Results of a Multicenter Retrospective Study

    by Panagiotis Mastorakos, Kareem El Naamani, Nimer Adeeb, Mathews Lan, James Castiglione, Omaditya Khanna, Ritam Ghosh, Jose Danilo Bengzon Diestro, Mahmoud Dibas, Rachel M. McLellan, et al.

    BACKGROUND AND PURPOSE: Despite the numerous studies evaluating the occlusion rates of aneurysms following WEB embolization, there are limited studies identifying predictors of occlusion. Our purpose was to identify predictors of aneurysm occlusion and the need for retreatment. MATERIALS AND METHODS: This is a review of a prospectively maintained database across 30 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB who had available intraprocedural data and long-term follow-up. RESULTS: We studied 763 patients with a mean age of 59.9 (SD, 11.7) years. Complete aneurysm occlusion was observed in 212/726 (29.2%) cases, and contrast stasis was observed in 485/537 (90.3%) of nonoccluded aneurysms. At the final follow-up, complete occlusion was achieved in 497/763 (65.1%) patients, and retreatment was required for 56/763 (7.3%) patients. On multivariable analysis, history of smoking, maximal aneurysm diameter, and the presence of an aneurysm wall branch were negative predictors of complete occlusion (OR, 0.5, 0.8, and 0.4, respectively). Maximal aneurysm diameter, the presence of an aneurysm wall branch, posterior circulation location, and male sex increase the chances of retreatment (OR, 1.2, 3.8, 3.0, and 2.3 respectively). Intraprocedural occlusion resulted in a 3-fold increase in the long-term occlusion rate and a 5-fold decrease in the retreatment rate (P < .001), offering a specificity of 87% and a positive predictive value of 85% for long-term occlusion. CONCLUSIONS: Intraprocedural occlusion can be used to predict the chance of long-term aneurysm occlusion and the need for retreatment after embolization with a WEB device. Smoking, aneurysm size, and the presence of an aneurysm wall branch are associated with decreased chances of successful treatment.


  • Long-Term Follow-Up of Cerebral Aneurysms Completely Occluded at 6 Months After Intervention with the Woven EndoBridge (WEB) Device: a Retrospective Multicenter Observational Study

    by Kareem El Naamani, Panagiotis Mastorakos, Nimer Adeeb, Mathews Lan, James Castiglione, Omaditya Khanna, Jose Danilo Bengzon Diestro, Rachel M. McLellan, Mahmoud Dibas, Justin E. Vranic, et al.

    The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.


  • Learning Curve for Flow Diversion of Posterior Circulation Aneurysms: A Long-Term International Multicenter Cohort Study

    by N. Adeeb, M. Dibas, C.J. Griessenauer, H.H. Cuellar, M.M. Salem, S. Xiang, A. Enriquez-Marulanda, T. Hong, H. Zhang, P. Taussky, et al.

    BACKGROUND AND PURPOSE: Flow diversion has gradually become a standard treatment for intracranial aneurysms of the anterior circulation. Recently, the off-label use of the flow diverters to treat posterior circulation aneurysms has also increased despite initial concerns of rupture and the suboptimal results. This study aimed to explore the change in complication rates and treatment outcomes across time for posterior circulation aneurysms treated using flow diversion and to further evaluate the mechanisms and variables that could potentially explain the change and outcomes. MATERIALS AND METHODS: A retrospective review using a standardized data set at multiple international academic institutions was performed to identify patients with ruptured and unruptured posterior circulation aneurysms treated with flow diversion during a decade spanning January 2011 to January 2020. This period was then categorized into 4 intervals. RESULTS: A total of 378 procedures were performed during the study period. Across time, there was an increasing tendency to treat more vertebral artery and fewer large vertebrobasilar aneurysms (P = .05). Moreover, interventionalists have been increasingly using fewer overlapping flow diverters per aneurysm (P = .07). There was a trend toward a decrease in the rate of thromboembolic complications from 15.8% in 2011–13 to 8.9% in 2018–19 (P = .34). CONCLUSIONS: This multicenter experience revealed a trend toward treating fewer basilar aneurysms, smaller aneurysms, and increased usage of a single flow diverter, leading to a decrease in the rate of thromboembolic and hemorrhagic complications.


  • The Woven EndoBridge (WEB) Device for the Treatment of Intracranial Aneurysms: Ten Years of Lessons Learned and Adjustments in Practice from the WorldWideWEB Consortium

    by Adam A. Dmytriw, Mahmoud Dibas, Sherief Ghozy, Nimer Adeeb, Jose Danilo Bengzon Diestro, Kevin Phan, Hugo H. Cuellar-Saenz, Ahmad Sweid, Sovann V. Lay, Adrien Guenego, et al.

    Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011–2015 (N = 66), 2016–2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020–2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


  • Multicenter Study for the Treatment of Sidewall versus Bifurcation Intracranial Aneurysms with Use of Woven EndoBridge (WEB)

    by Nimer Adeeb, Mahmoud Dibas, Jose Danilo Bengzon Diestro, Hugo H. Cuellar-Saenz, Ahmad Sweid, Sandeep Kandregula, Sovann V. Lay, Adrien Guenego, Leonardo Renieri, Sri Hari Sundararajan, et al.

    No significant difference in the angiographic and clinical outcomes was observed for the treatment of sidewall versus bifurcation intracranial aneurysms with use of Woven EndoBridge. Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the tr...


  • International Study of Intracranial Aneurysm Treatment Using Woven EndoBridge: Results of the WorldWideWEB Consortium

    by Adam A. Dmytriw, Jose Danilo Bengzon Diestro, Mahmoud Dibas, Kevin Phan, Ahmad Sweid, Hugo H. Cuellar-Saenz, Sovann V. Lay, Adrien Guenego, Leonardo Renieri, Ali Al Balushi, et al.


  • Vascular Malformations of the Spine

    by Paul M. Foreman, Philip G. R. Schmalz, John P. Deveikis, Mark R. Harrigan