Kook-Nyung Lee
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kook-Nyung Lee has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Dong-Ki Hong
Korea Elect Technol Inst KETI, Human IT Convergence Res Ctr, Seongnam 13509, South Korea
5 shared publicationsHye-Lim Kang
Korea Elect Technol Inst KETI, Human IT Convergence Res Ctr, Seongnam 13509, South Korea
5 shared publicationsWon-Hyo Kim
Korea Elect Technol Inst KETI, Human IT Convergence Res Ctr, Seongnam 13509, South Korea
5 shared publicationsSumi Yoon
Korea Elect Technol Inst KETI, Human IT Convergence Res Ctr, Seongnam 13509, South Korea
4 shared publicationsSunga Song
Korea Elect Technol Inst KETI, Human IT Convergence Res Ctr, Seongnam 13509, South Korea
4 shared publicationsWoo Kyeong Seong
Human IT Convergence Research Center, Korea Electronics Technology Institute (KETI), Gyeonggi, Republic of Korea
4 shared publications
Latest Publications
- Open Access
- 23 November 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (12) , 681
Operational Flaws in Field-Effect Transistor (FET)-Based Biosensors: Gate-Leakage Current in Water-Gate FET Devices and Fake Field-Effect Signals from Biomolecular Charge
Since the possibility of direct, label-free detection of biomolecules using field-effect transistors (FETs) was first proposed around 2000, hundreds to tens of thousands of studies on nanowire/nanoribbon FET (nanoFET) biosensors have followed; yet, aside from the ion-sensitive FET (ISFET) used for pH sensing and FET-based ion sensors employing ion-selective membranes, no FET biosensor has reached actual clinical or commercial use over the past two decades. Building on prior equivalent-circuit and “fake response” analyses of nanoFET read-out, this study re-examines the electrical measurement configuration of nanoFET biosensors and shows that a substantial portion of previously reported “direct detection” signals can be explained not by the target’s own electric field but by gate-leakage current inherent to water-gate architectures and by electrical-double-layer (EDL) potential changes that accompany routine solution exchange. Without a defect-free gate dielectric, the source-drain current necessarily contains a gate-leakage component indistinguishable from the channel-resistance signal; even with an intact gate oxide, the signal is governed not by the charge of the adsorbed target molecules themselves but by the EDL interfacial potential, which is altered by the electrolyte’s ionic strength, pH, and surface chemistry. In nanoFET biosensor research, given that a buffer exchange cannot be avoided in the experimental procedure, the EDL potential change attributable to the target molecule’s own contribution cannot be quantified or converted into target-concentration information—and this difficulty is especially acute near LOD-level concentrations, where it dilutes the very advantage the sensing principle is meant to offer. It is important to understand both the difficulty of distinguishing this from a fake signal arising from gate leakage and why the FET channel-conductance shift itself is difficult to convert into a measure of the target concentration’s contribution alone, given the procedural steps the detection process requires. This is because the target-detection experimental procedure for FET biosensors inherently cannot avoid solution exchange, so the change in EDL potential distribution attributable to target-molecule adsorption cannot be isolated.
- 23 November 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (12) , 681
Open AccessOperational Flaws in Field-Effect Transistor (FET)-Based Biosensors: Gate-Leakage Current in Water-Gate FET Devices and Fake Field-Effect Signals from Biomolecular Charge
Since the possibility of direct, label-free detection of biomolecules using field-effect transistors (FETs) was first proposed around 2000, hundreds to tens of thousands of studies on nanowire/nanoribbon FET (nanoFET) biosensors have followed; yet, aside from the ion-sensitive FET (ISFET) used for pH sensing and FET-based ion sensors employing ion-selective membranes, no FET biosensor has reached actual clinical or commercial use over the past two decades. Building on prior equivalent-circuit and “fake response” analyses of nanoFET read-out, this study re-examines the electrical measurement configuration of nanoFET biosensors and shows that a substantial portion of previously reported “direct detection” signals can be explained not by the target’s own electric field but by gate-leakage current inherent to water-gate architectures and by electrical-double-layer (EDL) potential changes that accompany routine solution exchange. Without a defect-free gate dielectric, the source-drain current necessarily contains a gate-leakage component indistinguishable from the channel-resistance signal; even with an intact gate oxide, the signal is governed not by the charge of the adsorbed target molecules themselves but by the EDL interfacial potential, which is altered by the electrolyte’s ionic strength, pH, and surface chemistry. In nanoFET biosensor research, given that a buffer exchange cannot be avoided in the experimental procedure, the EDL potential change attributable to the target molecule’s own contribution cannot be quantified or converted into target-concentration information—and this difficulty is especially acute near LOD-level concentrations, where it dilutes the very advantage the sensing principle is meant to offer. It is important to understand both the difficulty of distinguishing this from a fake signal arising from gate leakage and why the FET channel-conductance shift itself is difficult to convert into a measure of the target concentration’s contribution alone, given the procedural steps the detection process requires. This is because the target-detection experimental procedure for FET biosensors inherently cannot avoid solution exchange, so the change in EDL potential distribution attributable to target-molecule adsorption cannot be isolated.
- 1 March 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 330
Gas concentrator with an activated carbon adsorbent for breath analysis
- 1 March 2021
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 330
Gas concentrator with an activated carbon adsorbent for breath analysis
- 18 November 2020
- Published by Springer Nature in BioChip Journal
- Vol. 14 (4) , 381-389
Verification of Operating Principle of Nano Field-effect Transistor Biosensor with an Extended Gate Electrode
- 18 November 2020
- Published by Springer Nature in BioChip Journal
- Vol. 14 (4) , 381-389
Verification of Operating Principle of Nano Field-effect Transistor Biosensor with an Extended Gate Electrode
- 11 September 2020
- Published by Springer Nature in BioChip Journal
- Vol. 14 (3) , 308-316
Sensitivity Improvement in Electrochemical Immunoassays Using Antibody Immobilized Magnetic Nanoparticles with a Clean ITO Working Electrode
- 11 September 2020
- Published by Springer Nature in BioChip Journal
- Vol. 14 (3) , 308-316
Sensitivity Improvement in Electrochemical Immunoassays Using Antibody Immobilized Magnetic Nanoparticles with a Clean ITO Working Electrode
- Open Access
- 18 March 2020
- Published by Springer Nature in Micro and Nano Systems Letters
- Vol. 8 (1) , 1-6
Ion balance detection using nano field-effect transistor with an extended gate electrode
We developed a nano field-effect transistor (nanoFET) sensor for detecting ions in the air. Air ions can be measured using a commercial ion counter; however, it is large and expensive equipment, requires airflow to be through a cylinder type electrode or the plate electrode. NanoFET sensor is suitable for monitoring the ion generator module in home appliances like air purification. A nanoFET sensor can continuously measure the ion balance to monitor the performance of the ion generators which do static electricity elimination in electronics manufacturing lines. In this study, we developed a semiconductor sensor that can measure the ion balance in the air. The sensor is a nanoFET device with an extended gate electrode. The polarity of the ions adsorbed on the extended gate electrode is measured, and consequently, the ion imbalance is quantitatively estimated. The developed device enables reset with a switch connected to the extended gate. The sensor reads out with a current to voltage converting operational amplifier, a reset switch, and a microprocessor. We expect that the developed nanoFET sensor is practically applied to monitor the malfunction of ion generators in the air cleaner and in the static electricity elimination in electronics manufacturing lines.
- 18 March 2020
- Published by Springer Nature in Micro and Nano Systems Letters
- Vol. 8 (1) , 1-6
Open AccessIon balance detection using nano field-effect transistor with an extended gate electrode
We developed a nano field-effect transistor (nanoFET) sensor for detecting ions in the air. Air ions can be measured using a commercial ion counter; however, it is large and expensive equipment, requires airflow to be through a cylinder type electrode or the plate electrode. NanoFET sensor is suitable for monitoring the ion generator module in home appliances like air purification. A nanoFET sensor can continuously measure the ion balance to monitor the performance of the ion generators which do static electricity elimination in electronics manufacturing lines. In this study, we developed a semiconductor sensor that can measure the ion balance in the air. The sensor is a nanoFET device with an extended gate electrode. The polarity of the ions adsorbed on the extended gate electrode is measured, and consequently, the ion imbalance is quantitatively estimated. The developed device enables reset with a switch connected to the extended gate. The sensor reads out with a current to voltage converting operational amplifier, a reset switch, and a microprocessor. We expect that the developed nanoFET sensor is practically applied to monitor the malfunction of ion generators in the air cleaner and in the static electricity elimination in electronics manufacturing lines.
- 17 December 2019
- Published by Springer Nature in BioChip Journal
- Vol. 13 (4) , 387-393
Electrochemical Immunoassay Based on Indium Tin Oxide Activity Toward a Alkaline Phosphatase
- 17 December 2019
- Published by Springer Nature in BioChip Journal
- Vol. 13 (4) , 387-393
Electrochemical Immunoassay Based on Indium Tin Oxide Activity Toward a Alkaline Phosphatase
- 1 May 2019
- Published by Elsevier in Microelectronic Engineering
- Vol. 213, 35-40
I-V hysteresis characteristics of nano-field effect transistor (nanoFET) sensor with a floating metal gate electrode
- 1 May 2019
- Published by Elsevier in Microelectronic Engineering
- Vol. 213, 35-40
I-V hysteresis characteristics of nano-field effect transistor (nanoFET) sensor with a floating metal gate electrode
- Open Access
- 18 October 2017
- Published by MDPI AG in Biosensors
- Vol. 7 (4) , 48
Encapsulation-Stabilized, Europium Containing Nanoparticle as a Probe for Time-Resolved luminescence Detection of Cardiac Troponin I
The use of a robust optical signaling probe with a high signal-to-noise ratio is important in the development of immunoassays. Lanthanide chelates are a promising material for this purpose, which provide time-resolved luminescence (TRL) due to their large Stokes shift and long luminescence lifetime. From this, they have attracted considerable interest in the in vitro diagnostics field. However, the direct use of lanthanide chelates is limited because their luminescent signal can be easily affected by various quenchers. To overcome this drawback, strategies that rely on the entrapment of lanthanide chelates inside nanoparticles, thereby enabling the protection of the lanthanide chelate from water, have been reported. However, the poor stability of the lanthanide-entrapped nanoparticles results in a significant fluctuation in TRL signal intensity, and this still remains a challenging issue. To address this, we have developed a Lanthanide chelate-Encapsulated Silica Nano Particle (LESNP) as a new immunosensing probe. In this approach, the lanthanide chelate is covalently crosslinked within the silane monomer during the silica nanoparticle formation. The resulting LESNP is physically stable and retains TRL properties of the parent lanthanide chelate. Using the probe, a highly sensitive, sandwich-based TRL immunoassay for the cardiac troponin I was conducted, exhibiting a limit of detection of 48 pg/mL. On the basis of the features of the LESNP such as TRL signaling capability, stability, and the ease of biofunctionalization, we expect that the LESNP can be widely applied in the development of TRL-based immunosensing.
- 18 October 2017
- Published by MDPI AG in Biosensors
- Vol. 7 (4) , 48
Open AccessEncapsulation-Stabilized, Europium Containing Nanoparticle as a Probe for Time-Resolved luminescence Detection of Cardiac Troponin I
The use of a robust optical signaling probe with a high signal-to-noise ratio is important in the development of immunoassays. Lanthanide chelates are a promising material for this purpose, which provide time-resolved luminescence (TRL) due to their large Stokes shift and long luminescence lifetime. From this, they have attracted considerable interest in the in vitro diagnostics field. However, the direct use of lanthanide chelates is limited because their luminescent signal can be easily affected by various quenchers. To overcome this drawback, strategies that rely on the entrapment of lanthanide chelates inside nanoparticles, thereby enabling the protection of the lanthanide chelate from water, have been reported. However, the poor stability of the lanthanide-entrapped nanoparticles results in a significant fluctuation in TRL signal intensity, and this still remains a challenging issue. To address this, we have developed a Lanthanide chelate-Encapsulated Silica Nano Particle (LESNP) as a new immunosensing probe. In this approach, the lanthanide chelate is covalently crosslinked within the silane monomer during the silica nanoparticle formation. The resulting LESNP is physically stable and retains TRL properties of the parent lanthanide chelate. Using the probe, a highly sensitive, sandwich-based TRL immunoassay for the cardiac troponin I was conducted, exhibiting a limit of detection of 48 pg/mL. On the basis of the features of the LESNP such as TRL signaling capability, stability, and the ease of biofunctionalization, we expect that the LESNP can be widely applied in the development of TRL-based immunosensing.
- 1 June 2016
- Published by Elsevier in Microelectronic Engineering
- Vol. 158, 75-79
Detecting ions in air using a nanofield-effect transistor (nanoFET)
- 1 June 2016
- Published by Elsevier in Microelectronic Engineering
- Vol. 158, 75-79
Detecting ions in air using a nanofield-effect transistor (nanoFET)
- 18 May 2010
- Published by American Chemical Society (ACS) in Journal of Combinatorial Chemistry
- Vol. 12 (4) , 463-471
Automated Maskless Photolithography System for Peptide Microarray Synthesis on a Chip
Maskless photolithographic peptide synthesis was performed on a glass chip using an automated peptide array synthesizer system. The peptide array synthesizer was built in a closed box, which contained optical and fluidic systems. The conditions for peptide synthesis were fully controlled by a computer program. For the peptide synthesis on a glass chip, 20 NVOC-protected amino acids were synthesized. The coupling efficiencies of two model peptide sequences were examined on ACA/APTS and PEG/CHI/GPTS chips. PEG/CHI/GPTS chip gave higher average stepwise yields of GIYWHHY (94%) and YIYGSFK (98%) than those of ACA/APTS chip. To quantify peptide−protein binding affinity, HPQ- or HPM-containing pentapeptides were synthesized on a PEG/CHI/GPTS chip and the binding event of Cy3 labeled-streptavidin was quantified. The peptide sequence of IQHPQ showed highest binding affinity with Cy3 labeled-streptavidin. The results demonstrated that the photolithographic peptide array synthesis method efficiently quantified the binding activities of protein-peptide interactions and it can be used for additional biological assay applications.
- 18 May 2010
- Published by American Chemical Society (ACS) in Journal of Combinatorial Chemistry
- Vol. 12 (4) , 463-471
Automated Maskless Photolithography System for Peptide Microarray Synthesis on a Chip
Maskless photolithographic peptide synthesis was performed on a glass chip using an automated peptide array synthesizer system. The peptide array synthesizer was built in a closed box, which contained optical and fluidic systems. The conditions for peptide synthesis were fully controlled by a computer program. For the peptide synthesis on a glass chip, 20 NVOC-protected amino acids were synthesized. The coupling efficiencies of two model peptide sequences were examined on ACA/APTS and PEG/CHI/GPTS chips. PEG/CHI/GPTS chip gave higher average stepwise yields of GIYWHHY (94%) and YIYGSFK (98%) than those of ACA/APTS chip. To quantify peptide−protein binding affinity, HPQ- or HPM-containing pentapeptides were synthesized on a PEG/CHI/GPTS chip and the binding event of Cy3 labeled-streptavidin was quantified. The peptide sequence of IQHPQ showed highest binding affinity with Cy3 labeled-streptavidin. The results demonstrated that the photolithographic peptide array synthesis method efficiently quantified the binding activities of protein-peptide interactions and it can be used for additional biological assay applications.